Text of UPA-001-SP01 Attachment 11 REDACTED.pdf

Extracted from the file · 24 pages, 4 without text · 36,138 characters

Text of UPA-001-SP01 Attachment 10 REDACTED.pdf

Extracted from the file · 19 pages, 4 without text · 27,484 characters

Text of UPA-001-SP01 Attachment 9 REDACTED.pdf

Extracted from the file · 24 pages, 5 without text · 30,898 characters

Words on different pages
  1. Page 1 of 17

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  2. Page 2 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 2 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 2 of 17 General Facility Description The Barnabas Road Newtown facility consists of two buildings originally constructed in 1991: - ~57,000 SF mixed use main building consisting of offices, conference rooms, operations centers, workrooms, and shop areas ~9,000 SF garage building used for fleet vehicle maintenance The main building has had recent renovations, including replacement of (35) variable air volume (VAV) and fan powered terminal (FPT) boxes and replacement of (2) rooftop units (RTUs). RTUs are cooling and ventilation only, with heating provided by a natural gas fired hot water (HW) boiler and HW reheats in the VAVs. RTUs and VAVs are controlled with an up-to-date Automated Logic Building Management System (BMS), with occupied/unoccupied scheduling, adaptive/optimal start/stop, and demand control ventilation. Additional spot heating and cooling for operations center areas is achieved with split system heat pumps, electric baseboard, and vestibule and maintenance areas with HW cabinet unit heaters (CUHs) and unit heaters (UHs) respectively. Lighting systems are LED with motion/occupancy controls. Lighting controls are reported to be commissioned and work well. The maintenance garage building is heated with direct-fire natural gas units in the garage bays, and a combination of packaged units and a hot water loop from an aged natural gas HW boiler in the remainder of the building. Typical building occupancy is 5 AM – 5 PM, Monday through Friday with limited weekend hours. 24-hour occupancy occurs during emergency and storm events. Occupied building operations are estimated to be 3,700 annual hours. Monthly Billing Analysis Natural gas data was received in the form of a natural gas bill. This information included the most recent natural gas billing rates and quantity of natural gas used, along with the previous 12 months of natural gas use. Electric use is metered but not billed at this site, with annual use provided; monthly use was modeled based on annual use, the site’s footprint, hours of operation, equipment and estimated utilization, and an example monthly load profile from a similar site. $0.1428/kWh was used as an electric rate based upon Eversource Facilities’ third-party electric supply costs for similar type facilities. The most recent 12 months are summarized below:
  3. Page 3 of 17

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  4. Page 4 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 4 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 4 of 17 The EUI metric can be used to baseline existing energy use for future comparison or to compare this building to similar buildings of this type (general office space/fitness center). Energy Star publishes median data by building type for overall comparison. An analysis was carried out with actual natural gas use and heating degree days (HDD), as seen below: The graph indicates a strong visual relationship between natural gas use and HDD, suggesting the majority of natural gas is used for building heating. Summer month natural gas use can likely be attributed to service hot water. The regression further shows a strong, statistically significant relationship to HDD, with an R 2 value of 0.99. Additional modeling of estimated monthly electrical data was conducted to help determine potential load profile as it is assumed by-month building electric load will be impacted by the impact of weather/occupancy on the site based on results of the NG correlation exercise. Below are graphs showing the relationship between modeled monthly use and cooling degree days: The regression suggests that campus monthly electrical use has a statistically significant relationship to CDD, with an R2 value of 0.53, indicating a reasonable model fit. The Department of Energy Superior Energy Performance (SEP) program qualifies that a statistical relationship exists between the two variables with an R 2 value of > 0.5, and a strong relationship with an R2 value of > 0.75.
  5. Page 5 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 5 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 5 of 17 Mechanical System Energy Use Breakdown Electric Use Based on the initial walk-through, the following electric energy use breakdown was developed based on estimates. These results should be considered high level and were sourced from motor nameplates, typical load factors, and estimated operational hours. Actual data logging would be required to confirm these assumptions. Estimated End Use Breakdown - Electricity Electric End Use Energy Use (kWh) HVAC - Fans, Pumps, and Cooling 302,000 Lighting 147,000 Air Compressor 12,000 Plug and Process 96,000 TOTAL 557,000 Natural Gas Use Based on the initial walk-through and provided billing data, the following site natural gas use breakdown was developed. As above, these results should be considered high level and were sourced from equipment nameplates, typical load factors, and estimated operational hours. Actual data logging would be required to confirm these assumptions.
  6. Page 6 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 6 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 6 of 17 Estimated End Use Breakdown - Natural Gas Natural Gas End Use Energy Use (CCF) Comfort Heating 22,000 Service Hot Water 2,000 TOTAL 24,000 Equipment Inventory: During the initial walkthrough, site equipment inventories were created to better understand the current equipment.
  7. Page 7 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 7 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 7 of 17 HVAC Equipment: Tag AHU-1 AHU-2 MAS-1 (4) VF-1 VF-4 VF-5 VF-6 VF-8 VF-10 VF-12 VF-13 VF-14 VF-15 VF-16 VF-17 VF-18 VF-19 VF-20 VF-21 VF-22 VF-23 VF-24 VF-25 VF-26 VF-27 VF-28 VF-29 VF-30 VF-31 VF-32 VF-33 VF-34 VF-35 VF-36 VF-37 VF-38 VF-39 VF-41 EF-2 - Eversource Newtown Service Center HVAC Equipment Inventory Cooling Total Max Type Manufacturer Model MBH Notes Ton Fan HP CFM Air Handling Unit Trane CSAA021 101.38 16.08 Serves main building Air Handling Unit Trane CSAA021 101.38 16.08 Serves main building Make up Air Unit Reznor Not in service Packaged RTU Trane YHC060F4RHA1R 5 104 1.4 Serves garage RTU Reznor Preeva Serves main building Packaged RTU Trane YSC092H3RHA29K 7.5 4.7 Condenser Trane 4TTA7048A4 0.2 Ceiling-Suspended Indoor Unit Mitsubishi PCA-A30KA7 2.5 670 Condenser Mitsubishi PUY-A30NHA7 1940 Ceiling-Suspended Indoor Unit Mitsubishi PKA-A12HA7 1 Condenser Trane PUY-A12NKA7 Variable Air Volume Box Trane VPWF12-SQ04 32.4 0.125 1,120 Variable Air Volume Box Trane VPWF10-SQ03 17.3 0.33 800 Variable Air Volume Box Trane VPWF12-SQ04 1 1,400 Variable Air Volume Box Trane VPWF10-SQ03 20.3 0.33 940 Variable Air Volume Box Trane VPWF06-SQ02 8.6 0.125 400 Variable Air Volume Box Trane VPWF10-SQ03 20 0.33 930 Variable Air Volume Box Trane VPWF12-SQ04 26.8 0.33 1,240 Variable Air Volume Box Trane VPWF06-SQ02 11.7 0.125 435 Variable Air Volume Box Trane VPWF06-SQ02 7.7 0.125 285 Variable Air Volume Box Trane VPWF10-SQ03 23.1 0.33 855 Variable Air Volume Box Trane VPWF06-SQ02 9.7 0.125 360 Variable Air Volume Box Trane VPWF08-SQ03 19.4 0.33 720 Variable Air Volume Box Trane VPWF08-SQ03 11.7 0.33 540 Variable Air Volume Box Trane VPWF08-SQ03 15.6 0.33 720 Variable Air Volume Box Trane VPWF08-SQ03 15.6 0.33 720 Variable Air Volume Box Trane VPWF08-SQ03 17.8 0.33 660 Variable Air Volume Box Trane VPWF08-SQ03 15.3 0.33 570 Variable Air Volume Box Trane VPWF06-SQ02 8.1 0.125 300 Variable Air Volume Box Trane VPWF06-SQ02 9.8 0.125 455 Variable Air Volume Box Trane VPWF06-SQ02 8.7 0.125 405 Variable Air Volume Box Trane VPWF08-SQ03 12.5 0.33 580 Variable Air Volume Box Trane VPWF08-SQ03 17.1 0.33 635 Variable Air Volume Box Trane VPWF08-SQ03 16.6 0.33 615 Variable Air Volume Box Trane VPWF06-SQ02 9.7 0.125 360 Variable Air Volume Box Trane VPWF08-SQ03 17.4 0.33 645 Variable Air Volume Box Trane VPWF10-SQ03 18.7 0.33 865 Variable Air Volume Box Trane VPWF08-SQ03 11.7 0.125 540 Variable Air Volume Box Trane VPWF08-SQ03 13.5 0.125 500 Variable Air Volume Box Trane VPWF08-SQ03 12.4 0.33 575 Variable Air Volume Box Trane VPWF06-SQ02 7.8 0.125 290 Variable Air Volume Box Trane VPWF08-SQ03 14.8 0.33 685 Variable Air Volume Box Trane VPWF08-SQ03 14.8 0.33 685 Variable Air Volume Box Trane VCCF10 1,000 Cooling only Variable Air Volume Box Trane VPEF-6"-02SQ 6.8 0.125 240 Has electric reheat (2 kW) Variable Air Volume Box Trane VPEF-6"-02SQ 8.5 0.125 250 Has electric reheat (2.5 kW) Exhaust Fan Greenheck G-95-D 1,059 Exhaust Fan Greenheck GB-80-4 0.25 Exhaust Fan Greenheck GB-130-4X-QD
  8. Page 8 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 8 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 8 of 17 Eversource Newtown Unit Heaters Location Type Quantity Main Building Fan coil 4 Main Building Cabinet 3 Garage Fan coil 3 Garage Radiative 4 Compressed Air Equipment: Eversource Newtown Compressor Inventory Make Model Estimated Compressor Capacity Control Type (CFM) HP Powerex 2 X 5hp 10 *Annual run hours estimated 45 Recip Cooling Voltage Estimated Annual Run Hours Air Cooled 460 1,000 Eversource Newtown Dryer Inventory Rated Type Make Model CFM Altec Air RAD-007SA-1 75 Non-Cycling Eversource Newtown Air Receivers Location Capacity (Gallon) Integrated with Compressor 150 Chiller Summary: Chiller Summary Manufacturer Model Cooling Ton Trane RTAC 1554 155 Volts 460 Boiler Equipment: Eversource Newtown Boiler Summary Quantity Type 2 1 Hydronic Boiler Hydronic Boiler Make Model Weil McLain P-LGB-6-W Weil McLain GV-5 Max Input (MBH) 650 140 Max Output (MBH) 450 122 Service Point Main Building Garage
  9. Page 9 of 17

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 8 REDACTED Page 9 of 17 Eversource Energy – Newtown, CT Service Center QGM Consulting Scoping Study Febuary 2026, page 9 of 17 Eversource Newtown Boiler Pumps Description Quantity HP Main Building Boiler Supply 2 1.5 Main Building Boiler Return 2 0.25 Service Hot Water Heaters: Eversource Newtown Hot Water Heater Summary Max Max Input Quantity Make Model Output Service Point (MBH) (MBH) 1 AO Smith BTX-300 300 78 Main Building 1 Bradford-White D25T1253N 125 Garage Best Practices The Newtown facility was observed to be following several energy Best Practices: Use of LED lighting in most/all areas with aggressive controls VFD control of HW and CHW Scheduled nighttime/weekend temperature setback in most/all areas Demand Control Ventilation and Adaptive/Optimal Start/Stop HVAC control strategies in place Recent Energy Efficiency Projects Overview The campus has completed several energy efficiency projects in recent years. Listed below are some of the various completed energy projects: Upgrade to LED Lighting and advanced lighting controls Campus-wide DDC control of HVAC systems Upgrades to energy-savings equipment on replacement With the projects described above, QGM Consulting was challenged to find additional energy efficiency measures (EEMs) and sustainability projects. Potential recommendations are outlined below, some of which may require some additional analysis and monitoring. Site Energy Efficiency Measures/Recommendations EEM – 01 – Consider Building Shell Gap Remediation During the walkthrough of the site, gaps and cracks were noted at door and window seals and are suspected at roof/wall transitions. Insulation and air sealing are understood to be original construction and have likely degraded over time. Envelope gaps are thus allowing the infiltration/exfiltration of untempered air and increasing the load on HVAC equipment. It is recommended that the site perform a comprehensive building and
  10. Page 10 of 17

    No text on this page. It may be a picture of a page, such as a scan or a chart.

Text of UPA-001-SP01 Attachment 7 REDACTED.pdf

Extracted from the file · 14 pages, 4 without text · 17,187 characters

Text of UPA-001-SP01 Attachment 6 REDACTED.pdf

Extracted from the file · 13 pages, 3 without text · 14,512 characters

Text of UPA-001-SP01 Attachment 5 REDACTED.pdf

Extracted from the file · 14 pages, 4 without text · 17,555 characters

Text of UPA-001-SP01 Attachment 4 REDACTED.pdf

Extracted from the file · 16 pages, 4 without text · 19,788 characters

Text of UPA-001-SP01 Attachment 3 REDACTED.pdf

Extracted from the file · 12 pages, 4 without text · 11,899 characters

Text of UPA-001-SP01 Attachment 2 REDACTED.pdf

Extracted from the file · 11 pages, 4 without text · 10,526 characters

Text of UPA-001-SP01 Attachment 1 REDACTED.pdf

Extracted from the file · 13 pages, 3 without text · 17,141 characters

As listed on the current system

Question(s) Answered 1 thru 1 (Connecticut Light and Power Company dba Eversource Energy)(Supplemental/Revision) Date Filed: 10/07/2026

This filing on the current system (opens in a new tab)