Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Interrogatory responses

Answers to questions 1 thru 1

ResponseFiled by Connecticut Light and Power Company dba Eversource Energy14 files
Part of docket 26-05-10Open
  • Electric
Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

Files14

Search terms highlighted
Eversource rate increase is on 1 page of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of UPA-001-SP01 Attachment 11 REDACTED.pdf

Extracted from the file · 24 pages, 4 without text · 36,138 characters

Text of UPA-001-SP01 Attachment 10 REDACTED.pdf

Extracted from the file · 19 pages, 4 without text · 27,484 characters

Text of UPA-001-SP01 Attachment 9 REDACTED.pdf

Extracted from the file · 24 pages, 5 without text · 30,898 characters

Text of UPA-001-SP01 Attachment 8 REDACTED.pdf

Extracted from the file · 17 pages, 5 without text · 22,701 characters

Text of UPA-001-SP01 Attachment 7 REDACTED.pdf

Extracted from the file · 14 pages, 4 without text · 17,187 characters

1 page match
  1. Page 1 of 13

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  2. Page 2 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 2 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study - May 2026, page 2 of 13 The main building consists of offices, conference rooms, workrooms, and a warehouse The garage building used for fleet vehicle maintenance An aerial view of the campus is shown below: Maintenance Garage Main Building Total facility footprint is ~35,000 SF across both buildings. Typical occupancy is 7:00 AM – 4:00 PM Monday through Friday, with equipment scheduled for occupancy 5:00 AM – 5:00 PM. Total site operating hours are estimated to be ~3,300 annually. HVAC is provided through a mix of packaged rooftop units (RTUs) and split systems. HVAC equipment is controlled with a modern Building Management System (BMS) from Automated Logic.
  3. Page 3 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 3 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study May 2026, page 3 of 13 Lighting systems are modern LED with integrated controls and were observed to be functioning well. Monthly Billing Analysis Electric energy is metered but not billed at this site, with annual use provided. Monthly use was modeled based on annual use, the site’s footprint, hours of operation, equipment power density and estimated utilization, and example monthly load profiles from similar sites. $0.1428/kWh was used as an electric rate based upon Eversource Facilities’ third-party electric supply costs for similar type facilities. The most recent 12 months are summarized below: Energy Usage Costs and Costs $ Electric (kWh) $ 79,000 Annual Site Summary Energy kWh mmBTU 722,790 2,466 MT CO2 Unit Costs Emitted 210.3 $0.14 A monthly summary of estimated electric and thermal use is shown below: Monthly Utility Bill Summary Estimated Monthly Electric Month Electrical Estimated Use (kWh) Cost ($) Jan-25 87,434 Feb-25 69,947 Mar-25 52,461 Apr-25 34,974 May-25 29,145 Jun-25 64,118 Jul-25 81,605 Aug-25 69,947 Sep-25 58,290 Oct-25 29,145 Nov-25 64,118 Dec-25 81,605 TOTAL 722,790 $9,618 $7,694 $5,771 $3,847 $3,206 $7,053 $8,977 $7,694 $6,412 $3,206 $7,053 $8,977 $80,000 Estimated Blended Rate ($/kWh) $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 $0.11 The energy use intensity (EUI) shown below is an indicator of building performance in terms of energy use (kbtu) per building square foot:
  4. Page 4 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 4 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study May 2026, page 4 of 13 Building Energy Use Intensity (EUI) Utility Site EUI Source EUI Unit Electricity 69 194 kbtu/sf Source-site ratio per national average, source: https://portfoliomanager.energystar.gov/pdf/reference/Source%20Energy.pdf The EUI metric can be used to baseline existing energy use for future comparison or to compare this building to similar buildings of this type (general office space/fitness center). Energy Star publishes median data by building type for overall comparison. For electrical consumption, weather data for the site was utilized to help generate a monthly site profile. Below are graphs for the estimated monthly site electrical use and cooling degree days: The regression above along with provided annual use was developed to help determine building monthly electrical use. While electric peaks visually coincide with CDD, electric use also peaks with HDD due to the presence of electric heating. The first pass regression does not show a statistically significant relationship to CDD, with an R 2 value of 0.089. The Department of Energy Superior Energy Performance (SEP) program qualifies that a statistical relationship exists with an R2 value of 0.75. Additionally, monthly electric use was compared to HDD to address site electric heating operations in the developed profile, with similar results to the cooling analysis:
  5. Page 5 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 5 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study May 2026, page 5 of 13 As above for CDD, visual electrical use peaks to coincide with increases in HDD; however, the regression indicates no statistical relationship. The combination of two correlations makes initial regression difficult. As an additional aid to modeling electric use, CDD and HDD were next used with only the relevant months: summer and shoulder months for CDD and winter and shoulder months for HDD, with the resulting graphs shown below: R2 values of 0.96 for separated cooling electric use and 0.95 for separated heating electric use indicate good model fits for the estimated monthly electric use at this site. Mechanical System Energy Use Breakdown Electric Use Based on the initial walk-through, the following electric energy use breakdown was developed. These results should be considered high level and were sourced from motor nameplates, typical load factors, and estimated operational hours. Actual data logging is required to confirm these assumptions.
  6. Page 6 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 6 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study May 2026, page 6 of 13 Estimated End Use Breakdown - Electricity Electric End Use Energy Use (kWh) Plug & Process 103,000 HVAC - Heating & Cooling 455,000 Lighting 160,000 CAIR 7,000 TOTAL 725,000 Lighting Equipment The entire site was recently retrofitted with LED lighting that appears to be in good working order. Lighting systems include integrated controls in office and common areas that are reported to be functioning well. Equipment Inventory: Site equipment inventories were created to catalog the current equipment. Shown below are tables for HVAC and CAIR equipment on site.
  7. Page 7 of 13Match

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 7 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study Tag RTU-1 RTU-4 RTU-5 EXH-5 EXH-8 EXH-9 EXH-10 Booster 1 Booster 2 Type Air Handling Unit Roof Top Unit Packaged Heat Pump Package Heat Pump Roof Top Unit Roof Top Unit Cooling Tower Split System Outdoor Unit Exhaust Fan Exhaust Fan Exhaust Fan Exhaust Fan Exhaust Fan Exhaust Fan Circulation Pump Circulation Pump Circulation Pump Water Heater May 2026, page 7 of 13 Eversource East Hampton HVAC Equipment Inventory Cooling Manufacturer Model Serial # MBH Fan HP CFM Notes Ton Trane UCCAD08C0G0DV032 H23K95024 5 Trane THD180G4RND16HGE 211710932D 15 123 5 Trane WSC120H4RPA1FDN 183910335L 10 184 2.75 Trane WSC072H4RNA008G 183814126L 6 123 1 Trane THC048F4RGA66AC 234310253L 4 61.416 1 High Efficiency Unit Carrier TED360B4CY2B3E C20K06337 36 246 15 Trane TTA09044DAA02BS 23404121YA 9.5 Mitsubishi MUZ-FH12NA 1 Dayton 2RB60 26141665 785 Greenheck GB0-141-LNDX 15608439 Centri Master P10D4 320083 Centri Master PR13D8-23 KX10235 Centri Master PR14D2-2S Centri Master PR14D8-2S KX10233 0.5 3 3 Rheem ES120-36-G A252003009 4 kW electric water heater Eversource East Hampton Compressor Inventory Estimated Estimated Compressor Make Model HP Capacity Cooling Voltage Annual Control Type (CFM) Run Hours Quincy QT-10 10 19 Constant Speed Air Cooled 230 1,000 *Annual run hours estimated Eversource East Hampton Dryer Inventory Rated Make Model Type CFM Quincy QPNC 64 Non-Cycling Eversource East Hampton Air Receivers Location Capacity (Gallon) Integrated Storage Tank GTV 80 Site Energy Efficiency Measures/Recommendations EEM – 01 – Consider Building Shell Gap Remediation Gaps and cracks were noted at doors and windows and are likely to be present at the roof/wall building plane intersection. Insulation and air sealing are understood to be original construction and have likely degraded over time. Envelope gaps are thus allowing the infiltration/exfiltration of untempered air and increasing the load on HVAC equipment. It is recommended that the site perform a comprehensive building and thermal shell survey and remediate any identified gaps. Pictures below detail some of the observed building shell gaps:
  8. Page 8 of 13

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  9. Page 9 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 9 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study Existing transformer T-1 May 2026, page 9 of 13 Nameplate of same. Equipment vintage is not shown but font/labeling and wear suggest original construction Replacement with new transformers will improve efficiency and result in some minor electrical savings along with this operational improvement. Savings are based on an estimated current efficiency of 95% with an average load of 10%, operating 8,760 hours annually. Proposed transformer efficiency is 98.7%. Estimated Annual Energy Savings: 11,000 kWh Estimated Annual Cost Savings: $2,000 Estimated Implementation Costs: $60,000 Next Steps: - The site is encouraged to discuss potential electrical service upgrades with a trusted local vendor. EEM – 03 – Consider HVAC Balancing Discussion with facility staff included overcooling complaints in the main conference room. The issue is believed to lie in a controls/equipment gap and may be addressed in part by air balancing. The balancing process consists of surveying airflows against design capacities, checking/exercising dampers, and tuning fans and airflows to optimize delivery of tempered air. Energy savings were estimated based at an overall 2% reduction in estimated annual HVAC energy use (assuming the entire main building would be rebalanced). Savings are modest for this measure but compliment an existing operational need for air balancing.
  10. Page 10 of 13

    The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 6 REDACTED Page 10 of 13 Eversource Energy – East Hampton, CT QGM Scoping Study May 2026, page 10 of 13 Estimated Annual Energy Savings: 7,000 kWh Estimated Annual Cost Savings: $1,000 Estimated Implementation Costs: $20,000 Next Steps: - Site staff are encouraged to discuss testing and balancing with a trusted local vendor. EEM – 04 – Consider Automated Powered Window Blinds for Sun Facing Office Areas Discussion with facility staff noted sun complaints for high sun-facing windowed office areas at certain times of day. High solar gains can lead to overheating concerns as well as occupant complaints. Powered window blinds can be installed with autonomous controls, allowing raising or lowering based on solar intensity or a schedule, reducing both overheating and its associated cooling load as well as occupant discomfort. Energy savings were estimated based at an overall 5% reduction in estimated annual cooling energy use. Savings are modest for this measure but complement an existing operational need. Costs are high-level estimates based on internet research and assume (1) wall. Estimated Annual Energy Savings: 3,000 kWh Estimated Annual Cost Savings: $1,000 Estimated Implementation Costs: $7,500 Next Steps: - Site staff are encouraged to investigate powered energy blind product solutions and installers. Sustainability Considerations Background Site and portfolio sustainability is best guided by the framework and methodology set forth in ASHRAE Standard 228-2023 Standard Method of Evaluating Zero Net Energy and Zero Net Carbon Building Performance (available for purchase here: https://www.ashrae.org/technical-resources/bookstore/ansi-ashrae-standard-228-standardmethod-of-evaluating-zero-net-energy-and-zero-net-carbon-building-performance). The site is not known to have a present net-zero strategy; however, the ASHRAE standard presents a strong method to: - Assess current building energy use and carbon emissions Establish a baseline Develop milestones Develop a plan to reach milestones The data and information shown below are intended to help develop an understanding of where current portfolio sustainability goal aligns with current position.

Text of UPA-001-SP01 Attachment 5 REDACTED.pdf

Extracted from the file · 14 pages, 4 without text · 17,555 characters

Text of UPA-001-SP01 Attachment 4 REDACTED.pdf

Extracted from the file · 16 pages, 4 without text · 19,788 characters

Text of UPA-001-SP01 Attachment 3 REDACTED.pdf

Extracted from the file · 12 pages, 4 without text · 11,899 characters

Text of UPA-001-SP01 Attachment 2 REDACTED.pdf

Extracted from the file · 11 pages, 4 without text · 10,526 characters

Text of UPA-001-SP01 Attachment 1 REDACTED.pdf

Extracted from the file · 13 pages, 3 without text · 17,141 characters

As listed on the current system

Question(s) Answered 1 thru 1 (Connecticut Light and Power Company dba Eversource Energy)(Supplemental/Revision) Date Filed: 10/07/2026

This filing on the current system (opens in a new tab)