Interrogatory responses
Answers to questions 1 thru 1
Files14
UPA-001-SP01_Final.pdf
PDF · 109 KB · 1 pageText searchable
Download UPA-001-SP01_Final.pdfRead the text of UPA-001-SP01_Final.pdf
UPA-001-SP01 Attachment 13 REDACTED.pdf
PDF · 4.6 MB · 14 pagesText searchable
Download UPA-001-SP01 Attachment 13 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 13 REDACTED.pdf
UPA-001-SP01 Attachment 12 REDACTED.pdf
PDF · 3.3 MB · 15 pagesText searchable
Download UPA-001-SP01 Attachment 12 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 12 REDACTED.pdf
UPA-001-SP01 Attachment 11 REDACTED.pdf
PDF · 3.9 MB · 24 pagesText searchable
Download UPA-001-SP01 Attachment 11 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 11 REDACTED.pdf
UPA-001-SP01 Attachment 10 REDACTED.pdf
PDF · 3.7 MB · 19 pagesText searchable
Download UPA-001-SP01 Attachment 10 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 10 REDACTED.pdf
UPA-001-SP01 Attachment 9 REDACTED.pdf
PDF · 3.9 MB · 24 pagesText searchable
Download UPA-001-SP01 Attachment 9 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 9 REDACTED.pdf
UPA-001-SP01 Attachment 8 REDACTED.pdf
PDF · 4.0 MB · 17 pagesText searchable
Download UPA-001-SP01 Attachment 8 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 8 REDACTED.pdf
UPA-001-SP01 Attachment 7 REDACTED.pdf
PDF · 3.7 MB · 14 pagesText searchable
Download UPA-001-SP01 Attachment 7 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 7 REDACTED.pdf
UPA-001-SP01 Attachment 6 REDACTED.pdf
PDF · 3.3 MB · 13 pagesText searchable
Download UPA-001-SP01 Attachment 6 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 6 REDACTED.pdf
UPA-001-SP01 Attachment 5 REDACTED.pdf
PDF · 3.6 MB · 14 pagesText searchable
Download UPA-001-SP01 Attachment 5 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 5 REDACTED.pdf
UPA-001-SP01 Attachment 4 REDACTED.pdf
PDF · 3.6 MB · 16 pagesText searchable
Download UPA-001-SP01 Attachment 4 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 4 REDACTED.pdf
UPA-001-SP01 Attachment 3 REDACTED.pdf
PDF · 3.7 MB · 12 pagesText searchable
Download UPA-001-SP01 Attachment 3 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 3 REDACTED.pdf
UPA-001-SP01 Attachment 2 REDACTED.pdf
PDF · 3.7 MB · 11 pagesText searchable
Download UPA-001-SP01 Attachment 2 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 2 REDACTED.pdf
UPA-001-SP01 Attachment 1 REDACTED.pdf
PDF · 2.8 MB · 13 pagesText searchable
Download UPA-001-SP01 Attachment 1 REDACTED.pdfRead the text of UPA-001-SP01 Attachment 1 REDACTED.pdf
Text of UPA-001-SP01 Attachment 11 REDACTED.pdf
Extracted from the file · 24 pages, 4 without text · 36,138 characters
Text of UPA-001-SP01 Attachment 10 REDACTED.pdf
Extracted from the file · 19 pages, 4 without text · 27,484 characters
Text of UPA-001-SP01 Attachment 9 REDACTED.pdf
Extracted from the file · 24 pages, 5 without text · 30,898 characters
Text of UPA-001-SP01 Attachment 8 REDACTED.pdf
Extracted from the file · 17 pages, 5 without text · 22,701 characters
Text of UPA-001-SP01 Attachment 7 REDACTED.pdf
Extracted from the file · 14 pages, 4 without text · 17,187 characters
Text of UPA-001-SP01 Attachment 6 REDACTED.pdf
Extracted from the file · 13 pages, 3 without text · 14,512 characters
Text of UPA-001-SP01 Attachment 5 REDACTED.pdf
Extracted from the file · 14 pages, 4 without text · 17,555 characters
Page 5 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 5 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 5 of 16 Estimated End Use Breakdown - Electricity Electric End Use Energy Use (kWh) HVAC - Fans, Pumps, and Cooling 289,000 Lighting 118,000 Air Compressor 9,000 Plug and Process 86,000 TOTAL 502,000 Natural Gas Use Based on the initial walk-through, the following site natural gas use breakdown was developed. As above, these results should be considered high level and were sourced from equipment nameplates, typical load factors, and estimated operational hours. Actual data logging is required to confirm these assumptions.Page 6 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 6 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 6 of 16 Estimated End Use Breakdown - Natural Gas Natural Gas End Use Energy Use (CCF) Comfort Heating 15,000 Service Hot Water 1,200 TOTAL 16,200 Equipment Inventory: Site equipment was surveyed and inventories were created to better understand the current equipment, as shown below. HVAC Equipment:Page 7 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 7 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 7 of 16 Eversource Stamford Service Center HVAC Equipment Inventory Tag Type Manufacturer Model AHU 1 AHU 2 AHU 3 AHU 6A RTU RTU-2 RTU-3 RTU-4 RTU-5 RTU-6 Air Handling Unit Air Handling Unit Air Handling Unit Air Handling Unit Packaged Roof Top Unit- Natural Gas Packaged Roof Top Unit- Natural Gas Packaged Roof Top Unit- Natural Gas Packaged Roof Top Unit- Natural Gas Packaged Roof Top Unit- Natural Gas Packaged Roof Top Unit- Natural Gas Wall Unit Condenser Condenser Condenser Condenser Condenser Exhaust Fan Exhaust Fan Exhaust Fan Exhaust Fan HW Boiler HW Boiler Trane Trane Trane Trane Trane Trane Trane Trane Trane Trane Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi Greenheck Greenheck CSAA006UAL00 CSAA010UAL00 CSAA030UAL00 CCDBG3ABOC YSC090A4EHA001 YHC048E4RZA2F YHC074F4RHA27H YHC060F4RHA2EC OABD030A4-C1B100AB YHC074F4RHA27H PKA-A30KA7 PUZ-A30NHA7 PUY-A30NHA7 SUZ-KA12NAHZ PUZ-HA24NHA1 PUY-A12NKA7 EXH-4 EXH-5 B-1 B-2 Cooling Ton MBH 7.5 4 6 5 2.5 6 134 96 122 104 60 122 Total Fan HP 2 3 10 0.75 3.1 0.75 3.5 1.4 6 3.5 Rated Notes CFM 3,000 Serves the offices 5,000 Serves locker rooms 15,000 1,500 2,475 1,200 1,860 2,000 1,100 1,860 0.1 CUE-090-E-1-19-X 0.1 903 850 850 Eversource Stamford Service Center Unit Heaters Location Type Quantity Service Garage Fan Coil 2 Service Garage Electric 2 Warehouse Fan Coil 3 Locker Room Fan Coil 2 Compressed Air Equipment: Eversource Stamford Compressor Inventory Estimated Compressor Estimated Make Model HP Capacity Control Cooling Voltage Annual Run (CFM) Type Hours Quincy QTH-15-120AM 15 51 Recip Air Cooled 460 1,000 *Annual run hours estimated Eversource Stamford Dryer Inventory Rated Make Model Type CFM Quincy QRHT-50 50 Non-CyclingPage 8 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 8 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 8 of 16 Eversource Stamford Air Receivers Location Capacity (Gallon) Integrated with Compressor 150 Chiller Summary: Eversource Stamford Chiller Summary Manufacturer Model Cooling Ton Volts Trane CGAM 080F 80 460 Best Practices The Stamford Service Center facility was observed during the assessment walkthrough to be following several energy Best Practices: Use of LED lighting in most/all areas with aggressive controls Variable Frequency Drive (VFD) control of HW and CHW Pumps VFD control of some AHU fans Scheduled nighttime/weekend temperature setback in most/all areas Demand Control Ventilation and Adaptive/Optimal Startup HVAC control strategies in place Recent Energy Efficiency Projects Overview The campus has completed several energy efficiency projects in recent years. Listed below are some of the various completed energy projects: New Chiller New HW and CHW pumps with VFDs With the projects described above, QGM Consulting was challenged to find additional energy efficiency measures (EEMs) and sustainability projects. Potential recommendations are outlined below, some of which may require some additional analysis and monitoring. Site Energy Efficiency Measures/Recommendations EEM – 01 – Consider Building Shell Gap Remediation Gaps and cracks were noted at door and window seals and are suspected at roof/wall transitions in multiple areas throughout the facility. Insulation and air sealing are understood to be original construction and have likely degraded over time. Envelope gaps are thus allowing the infiltration/exfiltration of untempered air and increasing the load on HVAC equipment.Page 9 of 16
No text on this page. It may be a picture of a page, such as a scan or a chart.Page 10 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 10 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 10 of 16 Estimated Implementation Costs: $10,000 Next Steps: - Spot readings are recommended to confirm equipment loading assumptions and schedules. - The site is encouraged to discuss potential control upgrades with a reputable mechanical/controls vendor. EEM – 03 – Control Main Conference Room Heating and Cooling via Occupancy An innovative control strategy noted in use at other Eversource sites is the control of auditorium and conference room HVAC equipment based on an occupancy schedule. These spaces see highly variable occupancy, particularly post-COVID. Setting these large and intermittently occupied spaces to unoccupied setpoints for significant periods of non-use (much as many sites do with lighting) reduces the associated energy expenditure, while still allowing a quick recovery for occupancy. An area of potential opportunity at the Stamford facility is the executive conference room and office suite. The example below summarizes a potential before and after schedule – assuming average consistent use in the 10 AM – 2 PM period of weekdays: HVAC Schedule - Existing and Proposed with Occupancy Control Sunday 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Occ Hrs UnOcc Hrs Existing Schedule Tuesday Wednesday Thursday Monday X X X X X X X X X X X X X X 0 24 X X X X X X X X X X X X X X 14 10 X X X X X X X X X X X X X X 14 10 Friday X X X X X X X X X X X X X X 14 10 Saturday X X X X X X X X X X X X X X 14 10 14 10 Proposed Schedule - Estimated Reduced Hours Monday Tuesday Wednesday Thursday Sunday 0 24 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Occ Hrs UnOcc Hrs X X X X X 0 24 X X X X X 5 19 X X X X X 5 19 Friday X X X X X 5 19 Saturday X X X X X 5 19 5 19 Implementation of this strategy may be possible via programming within the existing controls or require the installation of new thermostats or local controls and occupancy sensors. The table below shows estimated costs and savings from the implementation of this type of control. Note that the AHU serving this space utilizes electric heat. Estimated Annual Energy Savings: 10,200 kWh Estimated Annual Cost Savings: $1,500 Estimated Implementation Costs: $1,000 Next Steps: 0 24Page 11 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 11 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study - Febuary 2026, page 11 of 16 Review of BMS is recommended to confirm equipment loading assumptions and schedules. The site is encouraged to discuss potential control upgrades with an ALC representative or internal resources. EEM – 04 – Consider HVAC Balancing Discussion with facility personnel regarding similar sites highlights the need for HVAC equipment air balancing. The balancing process consists of surveying airflows against design capacities, checking/exercising dampers, and tuning fans and airflows to optimize delivery of tempered air. Energy savings were estimated based as an overall 2% reduction in estimated annual HVAC energy use. Savings are modest for this measure but compliment an existing operational need for air balancing. Costs assume use of inhouse personnel to effect changes. Estimated Annual Energy Savings: 4,000 kWh and 200 CCF Estimated Annual Cost Savings: $800 Estimated Implementation Costs: $5,000 Next Steps: - Equipment spot reads are recommended to confirm equipment loading assumptions and schedules. - The site is encouraged to discuss potential testing and balancing with a reputable local vendor. EEM – 05 – Replace Current Hydronic Boilers with High Efficiency Hydronic Boilers Currently (2) hydronic boilers are utilized on site to provide hot water heating. The current boilers are slightly aged and are standard efficiency models. It is highly recommended that the site consider installing high efficiency hydronic boilers to utilize less natural gas to heat the site. Savings estimate a current boiler efficiency of 80%, while the proposed average boiler efficiency is 94% based on manufacturer’s data and experience with these types of systems. Estimated Annual Energy Savings: 2,000 CCF Estimated Annual Cost Savings: $2,700 Estimated Implementation Costs: $70,000 Next Steps: - Facility staff should review equipment selection with a mechanical vendor or local supplier if planning to self-install. EEM – 06 – Replace Packaged Terminal Air Conditioner with Air Source Heat Pump A total of (4) aged package terminal air conditioner (PTAC) units were observed while on site. Below are photos of a few of the PTAC units:Page 12 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 12 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study PTAC mounted on exterior wall Febuary 2026, page 12 of 16 Example of aged PTAC unit PTACs are utilized in multiple perimeter areas. It is recommended to consider replacement of these PTAC units with high-efficiency Air Source Heat Pumps (ASHPs) to replace the aged, low-efficiency equipment and any electric resistance heating associated with these units. On review, several of these units were determined to not be in use. It is recommended that these units be removed or disabled if possible to prevent unneeded use. Savings are estimated assuming replacement of existing average equipment efficiencies: - 1.5 kW/ton cooling (COP of 2.3) 99% efficiency heating (COP of 0.99) With new higher efficiency equipment: - 1.2 kW/ton cooling (COP of 2.9) Heat pump heating COP of 3.0 Estimated savings are shown below: Estimated Annual Energy Savings: 10,000 kWh Estimated Annual Cost Savings: $1,400 Estimated Implementation Costs: $4,000 Next Steps: - Facility staff should review equipment selection with a mechanical vendor or local supplier if planning to install.Page 13 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 13 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 13 of 16 Sustainability Considerations Background Site and portfolio sustainability is best guided by the framework and methodology set forth in ASHRAE Standard 228-2023 Standard Method of Evaluating Zero Net Energy and Zero Net Carbon Building Performance (available for purchase here: https://www.ashrae.org/technical-resources/bookstore/ansi-ashrae-standard-228-standardmethod-of-evaluating-zero-net-energy-and-zero-net-carbon-building-performance). The site is not known to have a present net-zero strategy; however, the ASHRAE standard presents a strong method to: - Assess current building energy use and carbon emissions Establish a baseline Develop milestones Develop a plan to reach milestones The data and information shown below are intended to help develop an understanding of where current portfolio sustainability goal aligns with current position. Emissions Scopes Emissions reporting is generally addressed across three Emissions Scopes, as seen below: An important aspect of developing a sustainability plan is the determination of which emissions scopes will be targeted for reduction. The majority of sustainability planning at the time of this report is focused on Scopes 1Page 14 of 16
The Connecticut Light and Power Company d/b/a Eversource Energy REDACTED Docket No. 26-05-10 Date Issued August 07, 2026 UPA-001-SP01 Attachment 4 REDACTED Page 14 of 16 Eversource Energy – Stamford, CT Service Center QGM Scoping Study Febuary 2026, page 14 of 16 and 2, although large corporations with significant supply and delivery chains have begun to address Scope 3 as well. The focus of the sustainability plan in this report is on Scope 1 and 2 emissions. ASHRAE Standard 228-2023 Standard Method of Evaluating Zero Net Energy and Zero Net Carbon Building Performance ASHRAE 228-2023 includes the following diagram illustrating energy flows into, from, and out of a site: The difference between energy flow into a site, and energy flow out, is site net energy. The primary goal of sustainability is to reduce this net energy, and therefore, net carbon emissions associated with the site and its operation. Sustainability Plan With a carbon baseline established and a goal and timeframe put in place, the next step is to develop a sustainability plan to reduce site net energy and carbon. A four-step plan, as outlined in an article from CBRE (Decarbonizing Commercial Real Estate | CBRE) and shown in the chart below, is recommended:
Text of UPA-001-SP01 Attachment 3 REDACTED.pdf
Extracted from the file · 12 pages, 4 without text · 11,899 characters
Text of UPA-001-SP01 Attachment 2 REDACTED.pdf
Extracted from the file · 11 pages, 4 without text · 10,526 characters
Text of UPA-001-SP01 Attachment 1 REDACTED.pdf
Extracted from the file · 13 pages, 3 without text · 17,141 characters
As listed on the current system
Question(s) Answered 1 thru 1 (Connecticut Light and Power Company dba Eversource Energy)(Supplemental/Revision) Date Filed: 10/07/2026