Prefiled testimony
Witness: Dr. William Taylor
Files10
Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdf
PDF · 493 KB · 48 pagesText searchable
Download Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdfRead the text of Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdf
Ex. WOT-1_Resume.pdf
PDF · 207 KB · 6 pagesText searchable
Download Ex. WOT-1_Resume.pdfRead the text of Ex. WOT-1_Resume.pdf
Ex. WOT-2_Outlier_calculation_notebook.pdf
PDF · 350 KB · 2 pagesNo text in this file
Ex. WOT-3_Ratepayer impact calculations.pdf
PDF · 3.9 MB · 18 pagesNo text in this file
Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdf
PDF · 498 KB · 56 pagesText searchable
Download Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdfRead the text of Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdf
Ex. WOT-5_BLS total factor productivity by major sectors.xlsx
Excel · 180 KBText searchable
Download Ex. WOT-5_BLS total factor productivity by major sectors.xlsxRead the text of Ex. WOT-5_BLS total factor productivity by major sectors.xlsx
Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Excel · 9.3 MBText searchable
Download Ex. WOT-6_BLS total factor productivity by major industries.xlsxRead the text of Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
PDF · 422 KB · 49 pagesText searchable
Download Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdfRead the text of Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdf
PDF · 609 KB · 26 pagesText searchable
Download Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdfRead the text of Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdf
Ex. WOT-9 BLS productivity calculations.pdf
PDF · 27 KB · 1 pageText searchable
Download Ex. WOT-9 BLS productivity calculations.pdfRead the text of Ex. WOT-9 BLS productivity calculations.pdf
Page 39 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 37 of 46 1 decade by 2.3-2.6%. 45 If the goals of performance-based regulation include 2 achieving enhanced business operation efficiency and providing affordable service, 3 then revenue cap increase allowances should not be greater than what have been 4 provided to the Company over the past decade. Consequently, I recommend that 5 the Authority consider using the 62nd percentile performance in capital 6 productivity, in line with their historical 11.7-13.5% outperformance of peers – 7 rather than the average – in calculation of a capital PFP and a TFP (where 99th 8 percentile is the most efficient capital performance). 9 If the sensitivity or other analyses demonstrate a just and reasonable TFP value that 10 leads to more affordable rates for ratepayers than a value of 0.457%, I recommend 11 that TFP from that analysis be applied. 12 Secondary recommendations: If the Authority declines to set a TFP of 0.457% or 13 a TFP derived from the additional analyses described in the primary 14 recommendations, I recommend that the Authority do not set the TFP below 0. 15 Notably, LEI shows an average TFP over the study period of 2005-2024 that is 16 negative. However, as discussed earlier in testimony, changes in assumptions can 17 substantially alter the outputs of a model – in this case, the average TFP. Further, 18 changes in metrics can potentially have similarly large impacts on the TFP results 19 – an idea which is partially reinforced by the large observed gap between the TFP 20 presented by LEI and that calculated for utilities by BLS. With the potential for 45 Exhibit CLP-PBR-3, p. 11. 37Page 40 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 38 of 46 1 drastically different model outputs dependent on metrics and assumptions, paired 2 with the lack of robust sensitivity analysis demonstrating that a negative TFP is just 3 and reasonable, and noting that affordability is in the interest of ratepayers, I do not 4 believe that a negative TFP in the instant proceeding is justified. 5 However, if the Authority declines to set the TFP at 0.457%, to set the TFP based 6 on analysis outlined in the primary recommendations, and declines to set a non- 7 negative TFP, I then recommend using as a floor a TFP value of -1.04%, equivalent 8 to the average TFP values as presented in Figure 2 of Exhibit CLP-PBR-2, 9 excluding the statistical outlier year of 2019-2020. 10 General recommendation: Regardless of TFP selected by the Authority, I 11 recommend that the Authority strongly consider in setting the TFP that utilities 12 under traditional cost-of-service regulation have historically had financial incentive 13 to enlarge the rate base, which, using the formulas presented in the TFP study 14 submitted as part of the Company’s rate application, would lead to lower (more 15 negative) capital and total productivity values. I would recommend that the 16 Authority keep this in mind while also considering the goals of performance-based 17 regulation to achieve affordable service and business operation and investment 18 efficiency; and also consider that past utility success in growing the rate base – and 19 thus growing the opportunity for profit – is directly reflected in the TFP values 20 presented in Exhibit CLP-PBR-2. Further, I would recommend that any TFP value 21 be set with consideration of what good and expected utility performance is, not 38Page 41 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 39 of 46 1 necessarily a historical average under a framework that strongly financially 2 incentivizes decreasing capital (and total) productivity. 3 VI. METHODOLOGICAL 4 RECOMMENDATIONS 5 Q: AND GENERAL ARE THERE ALTERNATIVE METHODOLOGIES FOR CALCULATING PRODUCTIVITY VALUES (TFP AND PFP)? 6 7 ALTERNATIVES A. There are multiple methods that can be used to estimate productivity trends for a 8 given industry. One alternative method to indexing is using stochastic frontier 9 analysis. A frontier analysis identifies a best practice productivity value and then 10 assesses the company’s gap to optimal performance. It also allows for separating 11 noise from actual efficiency. 12 Q. CAN A FRONTIER ANALYSIS BE MORE INFORMATIVE AS TO HOW 13 TO SET A REVENUE CAP IN LINE WITH THE GOALS OF 14 AFFORDABILITY AND PERFORMANCE-BASED REGULATION? 15 A. Yes. The stated goals of performance-based regulation in Connecticut include 16 investment and business operations efficiency, as well as affordable service, as 17 priority outcomes. A frontier analysis identifies best practices and measures how 18 far utilities are from those best practices. It should be noted that a frontier analysis 19 may still fall short of true operational efficiency of utilities because utilities have 20 broadly been operating under cost-of-service frameworks that, as mentioned 21 elsewhere in my testimony, encourage utilities to reduce productivity (insofar as it 39Page 42 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 40 of 46 1 is defined as a ratio between customers served and capital expenditures). Therefore, 2 as an industry, existing best practices may not go so far as to optimize business 3 efficiency. 4 However, having an understanding of what the existing frontier of best practices 5 operationally is, and understanding that frontier may be able to be pushed even 6 further provided different incentive structures, the Authority would have an even 7 greater body of evidence to support selection of productivity factors that represent 8 good utility performance – mitigating the need to use the historical average when 9 financial incentives for utilities have been directly at odds with productivity. 10 Q. AUTHORITY REGARDING PRODUCTIVITY FACTORS, AND WHY? 11 12 DO YOU HAVE ANY OTHER RECOMMENDATIONS FOR THE A. Yes, the Authority should, in this or another appropriate docketed proceeding – 13 perhaps the Docket No. 21-05-15 reopeners – hire a consultant to perform a frontier 14 analysis of utility performance. Doing so will give the Authority deeper insight into 15 existing best practices and how far the Company is from that standard. PURA 16 would then have the option to set the productivity factor in future rate cases 17 somewhere between individual or average historical utility performance and the 18 frontier of real-world utility performance – a frontier which likely has some room 19 for growth in a future where financial incentives for utilities are better aligned with 20 more efficient performance and improved productivity. Having an improved 21 understanding of what the productivity of a frontier or “best-practice” utility looks 40Page 43 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 41 of 46 1 like is beneficial, as it provides additional context when setting targets and 2 allowances that should correspond with good utility performance. Such an 3 evaluation may consider sensitivity analysis to the reference year, different 4 weightings of utility data (instead of strictly an average), using different percentiles 5 of data as opposed to the mean, as well as various considerations of inputs and 6 outputs to calculate productivity metrics. For example, there is some research 7 demonstrating how the incorporation of variables can impact productivity. In an 8 analysis of Great Britain electric productivity, when incentives to the utilities for 9 achieving customer minutes lost – a reliability metric – were considered as part of 10 operating expenses, productivity measures went from -0.5% in the most recent 11 period to 5.8%. 46 Ultimately, as is possible, metrics should be considered that 12 reflect productivity and better incorporate the goals of utilities, particularly any that 13 tie to statutes, potentially including improved reliability and decarbonization. 14 I also recommend that in future rate cases robust sensitivity analysis be required, 15 potentially including direction to ensure fair ranges of values are assessed for key 16 assumptions. Such analysis may also require sensitivity to productivity input and 17 output metrics. I further recommend that the party performing the analysis be hired 18 by the Authority, if possible. If not possible, I recommend that the Authority retain 19 a consultant to assess the analysis submitted into the docketed proceeding since 46 V. Ajayi, K. Anaya, M. Pollitt (2021) Incentive regulation, productivity growth and environmental effects: the case of electricity networks in Great Britain. Working Paper No. 012, The Productivity Institute. 41Page 44 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 42 of 46 1 assumptions and metrics can have such substantial impact on model outputs, 2 potentially resulting in over a hundred million dollars difference in ratepayer 3 impacts over the course of a multi-year rate plan. 4 VII. CONCLUSIONS 5 Q. PLEASE SUMMARIZE YOUR RECOMMENDATIONS. 6 A. I have several recommendations. 7 The following recommendations, as split between whether an X-Factor be applied 8 to only OM&A costs, or both capital and OM&A costs, carry equal weight and are 9 dependent on the Authority’s decision on how to apply an X-Factor. 10 If the Authority elects to implement an X-Factor that applies across capital and 11 OM&A costs, my primary recommendations are as follows: 12 I recommend that the Authority consider setting the total factor productivity (TFP) 13 value at 0.457%, equivalent with the average TFP value from 2005-2024 for 14 utilities, as calculated using U.S. Bureau of Labor Statistics data. 47,48 I make this 15 recommendation – as outlined earlier in the testimony in more detail – because the 16 BLS productivity value is considerably more favorable to ratepayers than what is 17 proposed by the Company, and without robust sensitivity analysis to key 47 48 Calculated using BLS data and calculated as described in Section V.C. of this testimony. Exhibit WOT-6; Exhibit WOT-9. 42Page 45 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 43 of 46 1 assumptions it is my opinion that the Company has not demonstrated that the 2 proposed TFP is just and reasonable. 3 Additionally, I recommend that the Authority conduct or have conducted, ideally 4 by a third party hired by the Authority, 49 robust sensitivity analysis of key 5 assumptions and metrics used in LEI’s TFP calculations. In the event the Authority 6 cannot produce or acquire results to such an analysis through a hired third party on 7 the required timeline for the instant case, I recommend that the Authority direct the 8 Company to perform and submit results of such a sensitivity analysis. 9 In addition to, or as part of the sensitivity analysis, I recommend that the Authority 10 explore an alternative weighting schema to the data provided by LEI as part of the 11 TFP study conducted and submitted in the Company’s rate application – 12 specifically, that the Authority consider using the 62nd percentile performance in 13 capital productivity, in line with their historical 11.7-13.5% outperformance of 14 peers – rather than the average – in calculation of a capital PFP and a TFP (where 15 99th percentile is the most efficient capital performance). 16 I recommend that if the sensitivity or other analyses demonstrate a just and 17 reasonable TFP value exists that leads to more affordable rates than a value of 18 0.457%, then the TFP from that analysis be applied. 49 As noted by the Authority in the RE01 PFD, “PURA may retain a consultant pursuant to General Statutes § 16-8a to, for example, critically analyze and run alternative specifications on the TFP model.” RE01 PFD Appendix A, p. vi. 43Page 46 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 44 of 46 1 Secondary recommendations: If the Authority declines to set a TFP of 0.457% or 2 a TFP derived from the additional analyses described in the primary 3 recommendations, I recommend that the Authority do not set the TFP below 0. 4 With the variance in productivity factors derived from BLS versus that proposed in 5 the instant proceeding, paired with the knowledge that assumptions and metrics can 6 substantially influence model outputs, I do not believe it has been demonstrated 7 that a TFP value below 0 is just and reasonable. 8 However, if the Authority declines to set the TFP at 0.457%, to set the TFP based 9 on analysis outlined in the primary recommendations, and declines to set a non- 10 negative TFP, I then recommend using as a floor a TFP value of -1.04%, equivalent 11 to the average TFP values as presented in Figure 2 of Exhibit CLP-PBR-2, 12 excluding the statistical outlier year of 2019-2020. 13 Regardless of TFP selected by the Authority, I recommend that the Authority 14 strongly consider in setting the TFP that utilities under traditional cost-of-service 15 regulation have historically had financial incentive to enlarge the rate base, which, 16 using the formulas presented in the TFP study submitted as part of the Company’s 17 rate application, would lead to lower (more negative) capital and total productivity 18 values. 19 If the Authority elects to implement an X-Factor that applies across only OM&A 20 costs as Eversource proposes, I recommend that the Authority consider as a floor 21 an X-Factor of 0.675%, which is the average OM&A Partial Productivity Factor 44Page 47 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 45 of 46 1 (PFP) from the LEI study after discarding the statistical outlier year of 2019-2020. 2 Further, I recommend that the Authority consider a higher X-Factor, 1) because the 3 frontier of existing utility productivity based on existing best practices may not 4 extend to its potential limit as utility business models do not financially incentivize 5 productivity optimization like the private sector; 2) to align with the ideals of 6 performance-based regulation of excellent operational performance including 7 efficiency in business operations and investment, and affordable service, the X- 8 Factor should be set at a fair value that represents good utility performance – which 9 is not necessarily represented by historical averages that are estimated by a study 10 where confidence in study results is limited due to the lack of robust sensitivity 11 analysis. 12 Secondly, because assumptions and metrics can so substantially impact model 13 outputs – in this case measured productivity – I recommend that the Authority 14 conduct or have conducted, ideally by a third party hired by the Authority, 50 robust 15 sensitivity analysis of key assumptions used in LEI’s OM&A PFP calculations. I 16 recommend that if the sensitivity or other analyses demonstrate a just and 17 reasonable productivity value exists that leads to more affordable rates than a value 18 of 0.675%, then that productivity value should be applied. 50 As noted by the Authority in the RE01 PFD, “PURA may retain a consultant pursuant to General Statutes § 16-8a to, for example, critically analyze and run alternative specifications on the TFP model.” RE01 PFD Appendix A, p. vi. 45Page 48 of 48
Docket No. 26-05-10 Direct Testimony of Dr. William O. Taylor October 21, 2026 Page 46 of 46 1 Regardless of how the X-Factor is applied, I also conclude that the Authority 2 should consider hiring a consultant to perform a frontier analysis of utility 3 productivity to provide the Authority with a greater information base with which to 4 select appropriate productivity factors in future rate cases. 5 I also recommend that in future rate cases robust sensitivity analysis be required, 6 potentially including direction to ensure fair ranges of values are assessed for key 7 assumptions. Such analysis may also require sensitivity to productivity input and 8 output metrics. I further recommend that the party performing the analysis be hired 9 by the Authority, if possible. If not possible, I recommend that the Authority retain 10 a consultant to assess the analysis submitted into the docketed proceeding since 11 assumptions and metrics can have such substantial impact on model outputs, 12 potentially resulting in over a hundred million dollars difference in ratepayer 13 impacts over the course of a multi-year rate plan. 14 Q. DOES THIS CONCLUDE YOUR TESTIMONY? 15 A. Yes. 46
Text of Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
Extracted from the file · 49 pages · 84,190 characters
Text of Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdf
Extracted from the file · 26 pages · 16,707 characters
Text of Ex. WOT-9 BLS productivity calculations.pdf
Extracted from the file · 1 page · 900 characters
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Dr. William Taylor [26-05-10]