Prefiled testimony
Witness: Dr. William Taylor
Files10
Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdf
PDF · 493 KB · 48 pagesText searchable
Download Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdfRead the text of Will Taylor PFT Docket No. 26-05-10 (Acadia Center).pdf
Ex. WOT-1_Resume.pdf
PDF · 207 KB · 6 pagesText searchable
Download Ex. WOT-1_Resume.pdfRead the text of Ex. WOT-1_Resume.pdf
Ex. WOT-2_Outlier_calculation_notebook.pdf
PDF · 350 KB · 2 pagesNo text in this file
Ex. WOT-3_Ratepayer impact calculations.pdf
PDF · 3.9 MB · 18 pagesNo text in this file
Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdf
PDF · 498 KB · 56 pagesText searchable
Download Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdfRead the text of Ex. WOT-4_Acadia Center FERC Docket No ER26-2389-000 Initial Paper Hearing Brief.pdf
Ex. WOT-5_BLS total factor productivity by major sectors.xlsx
Excel · 180 KBText searchable
Download Ex. WOT-5_BLS total factor productivity by major sectors.xlsxRead the text of Ex. WOT-5_BLS total factor productivity by major sectors.xlsx
Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Excel · 9.3 MBText searchable
Download Ex. WOT-6_BLS total factor productivity by major industries.xlsxRead the text of Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
PDF · 422 KB · 49 pagesText searchable
Download Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdfRead the text of Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdf
PDF · 609 KB · 26 pagesText searchable
Download Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdfRead the text of Ex. WOT-8_Pacific Northwest National Laboratory TFP Best Practices Presentation.pdf
Ex. WOT-9 BLS productivity calculations.pdf
PDF · 27 KB · 1 pageText searchable
Download Ex. WOT-9 BLS productivity calculations.pdfRead the text of Ex. WOT-9 BLS productivity calculations.pdf
Text of Ex. WOT-5_BLS total factor productivity by major sectors.xlsx
Sheet names, column headings and text cells; numbers left out
Text of Ex. WOT-6_BLS total factor productivity by major industries.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of Ex. WOT-7_Acadia Center FERC Docket No ER26-2389-000 Response Brief.pdf
Extracted from the file · 49 pages · 84,190 characters
Page 7 of 26
Key Challenges for TFP Measurement in the Electricity Sector Measurement of output Key challenges in TFP measurement Measurement of input— especially the concept of capital Missing or inappropriate data Weights used for indexes 7Page 8 of 26
Output Measurement Methodology Outputs can be measured from the perspective of demand or supply: Demand Approach: Output is determined by the amount and value of energy (throughput) provided by distributors to their consumers A distributor’s volume of sales may represent energy throughput and total revenue represents its value Supply Approach: Output is determined by the availability of infrastructure and the condition of that infrastructure Distributors must also provide and maintain infrastructure for delivering electricity to consumers (and this is not costless) Reliability and quality of electricity supplied as well as coverage and capacity of the system 8Page 9 of 26
Output Measurement in Practice Output is typically measured as a combination of demand- and supply-side factors, although experts vary in their choice of which measures to include. With a price cap a company’s revenues are directly affected by how much energy is sold, and a volumetric measure of output such as volume or peak demand is common With a revenue cap or a revenue-percustomer cap, the number of customers may be more important drivers for a company’s revenues 9Page 10 of 26
Output Measurement Bias, Recommendations, Key Questions to Ask Biases created by different output measures (such as sales volume or customer count) depend on the trend captured by the output measure Recommend using a mix of output measures that reflect both customer and sales density measures (number of customers, line miles, peak usage, etc.) to address these and other changing output trends in the electricity industry If volumetric charges are high, volume growth can increase revenues more than costs, creating a positive bias A key question regulators need to understand is the sensitivity of TFP to changes in various output measures, which can be uncovered by requesting sensitivity analyses Alternatively, volume growth can be slowed by energy efficiency and demand response programs, creating a negative bias 10Page 11 of 26
Input Measurement Input indexes are used to capture growth in input quantities and growth in input prices, as both components make up the growth in company costs • Input indexes are typically comprised of multiple inputs, with distribution systems typically including two broad categories: operations and maintenance expenditure and capital expenditure • In North America, operations and maintenance is often separated into labor, materials, and services • The weights of input indexes are determined by the relative cost share of each input to the total cost of all inputs, with capital subindexes typically being allocated the heaviest weights as distribution systems are capital intensive 11Page 12 of 26
Labor, Materials and Services Quantity can be measured directly when data permits. Quantity can be measured indirectly by deflating the value of relevant costs. For example, labor quantity can be measured with the number of full-time employees, although labor input data is increasingly difficult to obtain due to contracted labor services For example, labor costs (measured by salary and wage expenses) can be deflated by relevant labor price indexes (measured by a salary and wage price index) to obtain implicit quantity measures. 12Page 13 of 26
Labor, Materials and Services Bias, Recommendations, Key Questions to Ask Potential Biases Recommendations Key Questions Bias concerns in labor measurement are driven by the accurate measurement of labor quantity (such as number of full-time employees, which may be difficult to ascertain with contracted labor) or selection of relevant price indexes Recommend that methods be transparent and replicable Regulators can ask for sensitivity analyses of TFP to various measurement or deflation methods Bias concerns in materials and services measurement are driven by which expense categories are included, how joint expenses are allocated, and selection of relevant price indexes Recommend that methods be transparent and replicable Regulators can ask for sensitivity analyses of TFP to various methods or inclusion/exclusion of expense categories 13Page 14 of 26
Capital Measurement Approaches The capital quantity index measures the flow of services from the acquired capital assets • Capital quantity can be measured directly. • For example, with a measure of line length or transformer capacity. • Capital quantity can be measured indirectly with the deflated asset value method. • For example, capital quantity index is constructed by deflating data on the value of assets—a utility plant value is deflated using a construction cost index The capital price index measures the prices that would be earned in a competitive market for the rental of capital services Capital price is often inferred as most capital is owned by the distribution company 14Page 15 of 26
Key Points for Capital Measurement Capital Measurement Total capital stock needs to be inferred from current and past additions One method for adding up current and past additions is the perpetual inventory method A specific model of depreciation is chosen to reflect that assets may lose productivity over time: One Hoss Shay Geometric Decay Straight Line Annual capital costs can be measured directly by applying a constant percentage reflecting depreciation, the opportunity cost of capital and the rate of capital gains to the value of assets (Or indirectly as revenues minus operating costs) 15Page 16 of 26
Capital Measurement Bias, Recommendations, Key Questions to Ask Key Questions Potential Biases Recommendations The choice of benchmark year affects the starting capital cost and quantity and can create positive or negative bias in TFP estimates. Recommend a benchmark year that allows for many years of plant additions to minimize measurement error Does the benchmark year allow for many years of plant additions? Sensitivity analyses to different benchmark years can be requested Does TFP change significantly if a different benchmark year is chosen? Using net plant value (when gross plant value is appropriate) creates downward bias in TFP if net plant value underestimates capital quantity. In the literature, gross plant value is appropriate for one-hoss-shay, and net plant value for geometric decay, in practice either net or gross plant value are used with either depreciation assumption Is gross plant value overstating or net plant value understating capital quantity? Recommend requesting sensitivity analyses if it is believed the choice of gross or net plant value is overstating or understating capital quantity Does TFP change significantly if gross plant value is used instead of net plant value, or vice versa? Different depreciation assumptions can result in different capital quantity and price valuations Recommend regulators determine if the depreciation assumption reflects the underlying depreciation profile of the asset Recommend capital price and quantity indexes have the same depreciation assumption Does the depreciation assumption reflect the underlying depreciation profile of the asset? Sensitivity analyses can be requested to understand the impact of different depreciation assumptions Does TFP change significantly if different depreciation assumptions are used? Do capital price and quantity indexes have the same depreciation assumption? 16
Text of Ex. WOT-9 BLS productivity calculations.pdf
Extracted from the file · 1 page · 900 characters
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Dr. William Taylor [26-05-10]