Prefiled testimony
Witness: Eben Perkins
Files4
CES Direct Testimony 10.21.2026.pdf
PDF · 512 KB · 43 pagesText searchable
Download CES Direct Testimony 10.21.2026.pdfRead the text of CES Direct Testimony 10.21.2026.pdf
Exhibit UCONN-1 Perkins Resume.pdf
PDF · 116 KB · 2 pagesText searchable
Download Exhibit UCONN-1 Perkins Resume.pdfRead the text of Exhibit UCONN-1 Perkins Resume.pdf
Exhibit UCONN-2 Existing CPT Rate Options.pdf
PDF · 724 KB · 33 pagesText searchable
Download Exhibit UCONN-2 Existing CPT Rate Options.pdfRead the text of Exhibit UCONN-2 Existing CPT Rate Options.pdf
Exhibit UCONN-3 Eversource NH Rate LG CPT.pdf
PDF · 172 KB · 6 pagesText searchable
Download Exhibit UCONN-3 Eversource NH Rate LG CPT.pdfRead the text of Exhibit UCONN-3 Eversource NH Rate LG CPT.pdf
Page 5 of 43
I currently serve as Chief Strategy Officer on CES’s executive management team. In this 1 2 role I manage CES’s consulting practice, spearhead planning for the company’s continued 3 growth, and oversee the firm’s efforts to expand service offerings to our customers. My resume 4 is included in Exhibit UCONN-1. 5 Q. Have you testified before the Connecticut Public Utilities Regulatory Authority or other regulatory bodies in New England? 6 7 A. I have not previously testified before the Connecticut Public Utilities Regulatory Authority 8 (“PURA”). In Massachusetts, I testified before the Massachusetts Department of Public Utilities 9 (“DPU”) in Docket No. 22-22, Petition of NSTAR Electric Company for Approval of a General 10 Increase in Base Distribution Rates for Electric Service and a Performance-Based Ratemaking 11 Plan. I provided testimony in this proceeding on behalf of the University of Massachusetts System. 12 In Maine, I testified before the Maine Public Utilities Commission in a number of rate 13 cases and rate design proceedings including Docket No. 2021-00325 Commission Initiated 14 Investigation Into Transmission and Utility Rate Design To Promote State Policies; Docket No. 15 2022-00152, Request for Approval of a Rate Change Pertaining to Central Maine Power 16 Company; and Docket No. 2024-00137, Commission Initiated Investigation into Stranded Cost 17 Rate Design. I provided testimony in these proceedings on behalf of CES. 18 In New Hampshire, I testified before the New Hampshire Public Utilities Commission 19 (“NHPUC”) in Docket No. DE 23-039, Liberty Utilities (Granite State Electric) Corp. d/b/a 20 Liberty Request for Change in Distribution Rates, and Docket No. DE 24-070, Public Service 21 Company of New Hampshire d/b/a Eversource Energy Request for Change in Rates. In Docket 22 No. DE 23-039, I provided testimony on behalf of Dartmouth College. In Docket No. DE 24-070, 23 I provided testimony on behalf of a consortium of large customers in New Hampshire including 5Page 6 of 43
1 the University System of New Hampshire, Pike Industries, Inc., and Monadnock Paper Mills, Inc., 2 who intervened in Eversource’s distribution rate case to advocate for rate design modernization 3 for large customer classes. 4 Q. On whose behalf are you submitting testimony in this proceeding? 5 A. I am submitting testimony on behalf of the University of Connecticut and the UConn 6 Health System. 7 Q. Please provide an overview of the University of Connecticut and the UConn Health System. 8 9 A. The University of Connecticut (“UConn”) is a public land-grant research university system 10 that operates five academic campuses across Connecticut, serves more than 34,000 students, and 11 is a critical economic engine and healthcare provider for the state. UConn is dedicated to 12 excellence, and through its focus on teaching and learning, the University helps every student grow 13 intellectually and become a contributing member of the state, national, and world communities. 14 As Connecticut’s flagship public university, UConn promotes the health and well-being of 15 Connecticut’s citizens through enhancing the social, economic, cultural, and natural environments 16 of the state and beyond. 17 UConn’s academic campuses encompass nearly 17 million square feet of facilities across 18 more than 4,200 acres of property. UConn’s flagship campus is in Storrs, and the University 19 operates regional campuses in Avery Point, Hartford, Stamford, and Waterbury. UConn Health in 20 Farmington hosts the Schools of Medicine and Dental Medicine, graduate programs, clinics, and 21 John Dempsey Hospital. UConn Health’s statewide presence recently expanded through the 22 addition of UConn Health Waterbury Hospital to the UConn Health Community Network. This 23 nonprofit network connects community-based healthcare providers with the clinical, academic, 6Page 7 of 43
1 research, and educational capabilities of the state’s public academic medical center, while 2 preserving the hospital’s local identity and community-focused operations. 3 UConn’s facilities management team operates and maintains the University’s and UConn 4 Health’s footprint across the state, with a focus on delivering efficient, cost-effective, and 5 sustainable campus operations. UConn maintains an array of campus energy infrastructure to heat, 6 cool, and power its facilities, including highly efficient combined heat and power, fuel cells, and 7 onsite solar photovoltaics. UConn is constantly evaluating new energy technologies and 8 management strategies to support its core mission and help Connecticut advance its 9 decarbonization goals. 10 Q. Please summarize your testimony. 11 A. My testimony is organized into five sections, as described below: 12 • Section I provides an introduction. 13 • Section II summarizes the concerns that I have with the rate design proposal submitted by 14 Connecticut Light and Power (“Eversource” or the “Company”) in this proceeding and 15 recommends two actions to address these concerns. The Company’s proposal to maintain 16 its status quo transmission rate design and distribution rate design for large customers in 17 the Rate 55, Rate 56, Rate 57, and Rate 58 classes contradicts the analysis and testimony 18 provided by Eversource’s expert rate design witness, Ms. Amparo Nieto. To have 19 Eversource’s rate design for large customers support the major ratemaking objectives and 20 key principles articulated by Ms. Nieto, PURA should require the Company to: 1) introduce 21 a voluntary, opt-in coincident peak transmission (“CPT”) rate option for large customers, 22 which is an established transmission rate design solution that has been implemented by a 7Page 8 of 43
1 number of other electric utilities in New England including Eversource in its service 2 territories outside Connecticut, and 2) direct Eversource to examine time-of-day and 3 seasonal differentiation of distribution demand charges for large customers and propose a 4 tariff supported by class -specific evidence. 5 • Section III explains how Eversource’s transmission rate design for its large customers is 6 outdated, disconnected from the Company’s underlying cost of providing transmission 7 service to its customers, and contradicts principles of efficiency, fairness, and simplicity. 8 Section III details the proposed terms for a voluntary, opt-in CPT rate option that would 9 address these shortcomings and send a price signal that incentivizes large customers to 10 reduce their grid demand during periods of coincident peak demand on Eversource’s 11 transmission system that drives the need for system expansion. 12 • Section IV reviews the various examples of electric utilities in New England that have 13 implemented the recommended CPT rate option for large customers, including Eversource 14 in Massachusetts, National Grid in Massachusetts, Central Maine Power Company in 15 Maine, and Liberty Utilities in New Hampshire. Section IV also provides an overview of 16 the proposal currently being reviewed by the NHPUC which would have Eversource 17 implement a CPT rate option in New Hampshire for a limited number of large customers 18 including the University System of New Hampshire. 19 • Section V describes Eversource’s current distribution rate design for the Company’s large 20 customers and explains why core components of the rate design do not support the major 21 ratemaking objectives and principles articulated by Ms. Nieto. Section V calls for an 22 evidence-based review of Eversource’s distribution demand charges for large customers 8Page 9 of 43
1 that aligns with Ms. Nieto’s findings and would support beneficial electrification measures 2 among Eversource’s large customers in the coming years. 3 Q. Are you sponsoring any exhibits in addition to your testimony? 4 A. Yes, in addition to this testimony, we are sponsoring the following exhibits: 5 • Exhibit UCONN-1, Mr. Perkins’ Resume. 6 • Exhibit UCONN-2, Rate Terms and Conditions of Existing Rate CPT Options in Massachusetts, Maine, and New Hampshire: 7 8 o Eversource Energy Western Massachusetts Extra Large General Service: Rate T-5; 9 o Eversource Energy Cambridge Service Area Large General Service: Rate G-3; 10 o Eversource Energy Eastern Massachusetts Greater Boston Service Area Large General Service: Rate G-3; 11 o Eversource Energy Eastern Massachusetts South Shore, Cape Cod & Martha’s 12 Vineyard Service Area Large General Service: Rate G-3; 13 14 o Eversource Energy Western Massachusetts Large General Service: Rate G-3; 15 o Massachusetts Electric Company General Service Time-of-Use: Rate G-3; 16 o Central Maine Power Company Optional Targeted Service Rate: B-CPT General Service Coincident Peak; 17 o Liberty Utilities Rate G-1 General Service Time-of-Use. 18 19 20 • Exhibit UCONN-3, Eversource Rate LG CPT Proposed Tariff Terms, August 21, 2026, NHPUC Docket No. DE 26-042. 21 9Page 10 of 43
II. PURPOSE OF TESTIMONY: CONCLUSIONS & RECOMMENDATIONS 1 2 Q. What is the purpose of your testimony? 3 A. The purpose of this testimony is two-fold: 1) to explain why Eversource’s proposal to 4 maintain its existing rate design for large customers is unacceptable and ignores key findings of 5 the Company’s expert rate design witness, Ms. Amparo Nieto, and 2) to propose two 6 improvements that would help modernize the Company’s rate design for its large customers in a 7 manner that supports ratemaking principles of efficiency, equity, and simplicity and would help 8 preserve electricity affordability for all Eversource customers as Connecticut works to transition 9 to a decarbonized economy in the coming years. 10 Q. Please explain what you mean by Ms. Amparo Nieto’s key findings. 11 A. In her testimony, Ms. Nieto describes a Marginal Cost of Distribution Service study that 12 she performed and details how rate designs that use marginal cost information and follow marginal 13 cost principles are best suited to support three major ratemaking objectives: 1 1) fostering 14 economically-efficient energy usage decisions, 2) ensuring equitable rates or mitigating intra-class 15 cross-subsidies over time, and 3) preserving customer affordability in the transition to a 16 decarbonized sector. 17 On the first objective, Ms. Nieto argues that customers are able to make more informed 18 decisions that align with the provision of reliable service at the lowest possible cost when the 19 corresponding rates signal the true underlying cost impact from incremental usage. 2 On the second 20 objective, Ms. Nieto argues that marginal-cost based tariffs help prevent increases in inter and 21 intra-class cross subsidies as individual customers change their consumption because these rates 1 2 Exhibit CLP-MCOS-1, page 3, lines 8-9. Exhibit CLP-MCOS-1, page 3, lines 11-14. 10Page 11 of 43
1 generally help track ongoing changes in the incremental cost to serve, particularly when 2 differentiating by season. 3 On the third objective, Ms. Nieto argues that when utility charges are 3 set well above marginal unit costs, customers that add usage will tend to experience 4 disproportionally higher bills that exceed the cost of incremental service. 4 5 Q. Do you agree with Ms. Nieto? 6 A. Yes and no. I agree that these three major ratemaking objectives are critical and should 7 guide Eversource’s rate design for all customer classes. The problem is that these objectives are 8 not sufficiently reflected in the Company’s existing rate design for large customers in Connecticut. 9 In her testimony, Ms. Nieto concludes “I have reviewed the Company’s rate proposals and in my 10 opinion the direction of changes proposed aligns with what the MCOS suggests.” 5 “The proposals 11 recognize that rates should gradually be rebalanced to seek improved economic efficiency and 12 equity.” 6 Here, Ms. Nieto misses the mark. For large customers, there is no gradual rebalancing of 13 rate design. There is simply status quo, which, as we detail in the coming sections, includes blatant 14 examples of contradiction to the three major ratemaking objectives described by Ms. Nieto. 15 Q. How does Eversource’s existing transmission rate design for its large customers not support the three major ratemaking objectives articulated by Ms. Nieto? 16 17 A. Eversource assesses a monthly transmission demand charge to each large customer in a 18 manner that is disconnected from the cost that the Company incurs to provide transmission service 19 to its large customers. ISO New England (“ISO-NE”) allocates regional transmission costs and Exhibit CLP-MCOS-1, page 3, lines 17-20. Exhibit CLP-MCOS-1, page 4, lines 1-4. 5 Exhibit CLP-MCOS-1, page 17, lines 3-4. 6 Exhibit CLP-MCOS-1, page 17, lines 5-7. 3 4 11Page 12 of 43
1 associated reliability costs to Eversource and the other transmission owners throughout the region 2 based on each transmission owner’s monthly coincident peak load. 3 Eversource then recovers and reconciles this wholesale transmission cost through its retail 4 rates. 7 The Company uses a 12 coincident peak (“12CP”) allocation factor to assign transmission 5 revenue requirements to each rate class. According to Eversource, this methodology is designed 6 to reflect the methodology used in the development of the ISO-NE Open Access Transmission 7 Tariff (“OATT”) revenue requirement and the resulting charges billed to the Company for 8 transmission service under the OATT. 8 9 Rather than charging large customers for what they contribute to grid demand during 10 Eversource’s 12CP hours in a year, which determines the transmission cost that ISO-NE allocates 11 to Eversource for these customers, the Company bills each large customer based on its maximum 12 30-minute grid demand measured across nearly 25% of hours in a monthly billing cycle. Contrary 13 to Ms. Nieto’s first major ratemaking objective, the existing rate design does not foster 14 economically efficient energy usage decisions by customers. Rather than incentivizing targeted 15 demand management efforts by customers during periods that could set Eversource’s CP load hour 16 in a month, Eversource’s transmission rate design requires a large customer to manage its grid 17 demand across a broad window on every weekday. 18 In addition to diluting the price signal for large customers to reduce grid demand during 19 Eversource’s 12CP hours, the Company’s existing transmission rate design results in cost shifting 20 within each large customer class. Large customers that have lower grid demand during 21 Eversource’s 12CP hours, compared to their billed kilovolt-ampere (“kVA”) demand that 7 8 Eversource’s most recent RAM filing was made in PURA Docket No. 26-01-03. See Eversource response to UCONN-024. 12Page 13 of 43
1 Eversource captures from a customer’s maximum 30-minute on-peak grid demand, subsidize other 2 large customers by enabling Eversource to lower the effective transmission rate for all customers 3 in the class. This disparity should be examined under Ms. Nieto’s second major ratemaking 4 objective: to ensure equitable rates and mitigate intra-class cross-subsidies over time. 5 If, despite Eversource’s current transmission rate design, a large customer reduces its grid 6 demand during Eversource’s peak load hour in a month through onsite generation, efficiency 7 measures, manual load curtailment, and/or behind-the-meter energy storage (i.e., load shifting), 8 the customer may realize little retail transmission savings unless the reduction coincidentally 9 lowers the customer’s maximum 30-minute grid demand measured across all on-peak hours in the 10 month. Separate distributed energy resource (“DER”) incentives may be used to support 11 investment in these demand management measures, but their costs are recovered through public- 12 benefit charges which impacts total electricity rates. Jumping to a DER incentive offering without 13 first optimizing price signals sent through existing rates is a recipe for inefficiency and higher- 14 than-necessesary public-benefit charges over time. 15 Eversource’s existing transmission rate design has been in place since 2006. 9 The rate 16 design is out of date, especially considering the widespread development of distributed solar 17 generation throughout Connecticut over the last 20 years. The rate design does not support 18 investment by large customers in modern forms of onsite generation and load shifting 19 technologies, nor does it incentivize operational changes that enable large customers to 20 strategically reduce their contribution to peak demand on Eversource’s transmission system. 21 Because Eversource’s transmission rate design does not create the appropriate incentive for large 9 See Eversource’s response to UCONN-001. 13Page 14 of 43
1 customers to help themselves reduce the Company’s coincident peak demand, over time 2 Eversource’s peak demand will be higher than it otherwise should be, driving the need for earlier 3 or more significant transmission system expansion and resulting in higher transmission costs for 4 all ratepayers. This outcome is contrary to Ms. Nieto’s third major ratemaking objective: to 5 preserve customer affordability in the transition to a decarbonized sector. 6 Q. How does Eversource’s distribution rate design for its large customers not support the three major ratemaking objectives articulated by Ms. Nieto? 7 8 A. Eversource assesses a monthly distribution demand charge to each large customer based 9 on a trailing 11-month ratchet formula that lacks time-of-use differentiation and seasonal 10 differentiation. Eversource is proposing to maintain this rate design without modification. 11 Ms. Nieto concludes that time-differentiated distribution rates must keep in mind the 12 system-wide distribution hourly marginal cost patterns. 10 Eversource contends that this finding is 13 irrelevant to distribution rate design for large customers. 11 The lack of time-of-use periods in 14 Eversource’s distribution demand charges to large customers severs the price signal in distribution 15 rates from the true underlying cost impact from incremental usage. 16 Ms. Nieto also concludes that seasonal differentiation is necessary to improve price signals 17 in rate design. 12 She argues that continuing with year-round distribution time-of-use periods would 18 not support efficient adoption of heat pump rates. 13 The lack of seasonality in the design and 19 assessment of distribution demand charges for large customers contradicts cost causation 20 principles and Eversource’s stated goal to support beneficial electrification through rate design. Exhibit CLP-MCOS-1, page 17, lines 10-11. See Eversource response to UCONN-002. 12 Exhibit CLP-MCOS-1, page 18, lines 4-6. 13 Exhibit CLP-MCOS-1, page 18, lines 13-14. 10 11 14
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Eben Perkins [26-05-10]