Prefiled testimony
Witness: Juan-Pablo Velez
Files5
Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
PDF · 5.8 MB · 107 pagesText searchable
Download Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdfRead the text of Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
Search terms highlighted
Eversource rate increase is on 13 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Page 18 of 107
1 response to OCC-733 (Eversource and Nieto 09-11-26), applied to New England system load for 2 2022 through 2025 (ISO-NE n.d.). The full methodology is described in Exhibit JPV-2, Section 3 3. Figure 6 shows the result. Figure 6: Hourly marginal bulk transmission capacity costs, CT Eversource, 2025. 4 Distribution and transmission marginal costs display the same seasonal pattern: they are 5 concentrated entirely in the summer. 6 Q. How many new T&D costs does the average fossil fuel-heated home cause per year, 7 before installing a heat pump? 8 A. I’ve established that customer usage only causes new T&D costs during peak hours. Every 9 residential customer that consumes electricity during those hours causes new T&D costs – not 10 just heat pump customers. 11 So, to calculate how many new T&D costs the average fossil fuel-heated home causes per 12 year, I first identified how many kWh such a home consumes during peak hours every year. 13 Figure 7 revisits the monthly electricity consumption of these customers, with the portion 14 consumed during peak hours highlighted in red. 9 Average hourly load from CAIRO’s ResStock building-stock simulation of CL&P residential customers. An hour is classified as “peak” when it carries a marginal distribution or bulk transmission capacity cost exceeding 9 16Page 19 of 107
Figure 7: Average monthly electricity for simulated Eversource fossil fuel-heated homes before heat pump installation, with peak-hour usage highlighted. Peak hours are defined as hours where marginal T&D capacity cost exceeds 0.5¢/kWh, capturing 99% of total annual marginal cost. 1 In total, these customers consume an average of 1,599 kWh during peak hours — just 2 22% of their total annual usage. As Figure 7 shows, 100% of this peak hour usage occurs during 3 the summer. 4 Next, I identified the marginal T&D cost caused by each of those peak-hour kWh. On 5 average, each peak-hour kWh causes approximately 2.1¢ of new distribution costs and 5.3¢ of 6 new transmission costs. 10 7 We now have both ingredients: the number of peak-hour kWh each fossil fuel-heated 8 customer consumes, on average, and the marginal T&D cost of each one. Multiplying them 9 together — hour by hour, across the full year — gives us the total marginal T&D costs that the 0.5¢/kWh. This de minimis threshold excludes hours with trace probability-of-peak allocations that collectively account for less than 1% of total annual marginal capacity cost. See Exhibit JPV-2, Sections 2 and 3. The per-kWh cost varies by hour: distribution ranges from 0.6¢ to 6.3¢, and transmission from 0.5¢ to 19.6¢. Marginal costs are higher during the most constrained hours. The full methodology for how I derived these hourly costs is described in Exhibit JPV-2, Section 3. 10 17Page 20 of 107
1 average fossil fuel-heated home causes per year. Figure 8 shows the result, broken down by 2 season. 11 Figure 8: Seasonal delivery marginal cost for all Eversource fossil fuel-heated homes before heat pump installation. 3 The 1,599 kWh consumed during peak hours by the average fossil fuel-heated customer 4 cause a total of $28 in new distribution costs and $95 in new transmission costs, per year. As 5 Figure 8 shows, this combined marginal T&D cost of $123 is caused entirely by peak hour usage 6 during the summer. 7 This is the status quo of T&D cost causation for fossil fuel-heated homes. The key 8 question is: after these homes install heat pumps, do they start causing more than $123 in new 9 T&D costs per year? If so, under the cost-causation principle, their T&D bills should increase by 10 that increment — their incremental marginal T&D cost — and no more. 12 11 Q. What additional new transmission and distribution costs does the average fossil fuel- 12 heated customer cause per year after installing a heat pump? Weighted-average hourly load from CAIRO’s ResStock simulation multiplied by the hourly marginal-cost schedule derived in Exhibit JPV-2, Section 3, summed by season. See Exhibit JPV-2, Section 4. 11 By “incremental marginal T&D cost,” I mean the increase in a customer’s annual marginal T&D costs that results from installing a heat pump — not the total marginal T&D cost. Every residential customer already causes some marginal T&D cost from summer peak-hour usage. The question is how much more a heat pump adds. 12 18Page 21 of 107
1 A. As previously established, only usage during peak hours causes new T&D costs. Before 2 installing a heat pump, the average fossil fuel-heated customer consumed 1,599 kWh during 3 summer peak hours every year, causing a total of $123 in T&D costs per year. 4 After installing the heat pump, these customers add thousands of kWh in winter — but as 5 I showed in the preceding questions, winter kWh carry near zero marginal T&D cost. Virtually 6 all incremental peak-hour usage comes from a modest increase in summer cooling, as some 7 homes gain full air conditioning for the first time. That amounts to just 114 additional peak-hour 8 kWh per year, on average. Figure 9: Average monthly electricity for all simulated Eversource fossil fuel-heated homes, before and after heat pump installation, with peak-hour usage highlighted. The darker red at the top of each bar is the new peak-hour demand added by the heat pump; the lighter red below it is peak-hour demand the home already had before the heat pump. Peak hours are defined as hours where marginal T&D capacity cost exceeds 0.5¢/kWh, capturing 99% of total annual marginal cost. 9 Figure 9 makes this visible. When fossil fuel-heated customers install heat pumps, 97% 10 of their incremental load falls between October and April — when there are no peak hours and 19Page 22 of 107
1 therefore zero marginal T&D cost. Of the thousands of new kWh these customers add each year, 2 only 114 coincide with peak hours (shown in red) — less than 1.8% of the total. 3 4 So what do those 114 additional kWh of peak-hour usage do to these customers’ marginal T&D costs? Figure 10 shows the answer. 13 Figure 10: Seasonal delivery marginal cost for all Eversource fossil fuel-heated homes, before and after heat pump installation. 5 Before adopting heat pumps, fossil fuel-heated customers caused virtually zero new T&D 6 costs in winter, and that remains the case after they electrify their heating. In summer, their 7 marginal T&D costs barely move: $133, up from $123. Their incremental marginal T&D cost 8 is therefore just $10 per year, on average. 9 Q. Why is it the case that fossil fuel-heated customers cause nearly zero new T&D costs in 10 winter? 11 A. The Company’s own Marginal Cost of Service (MCOS) study assigns near-zero marginal 12 distribution costs to winter hours. 13 Same data sources as Figure 8, showing both the fossil-heated and heat pump profiles. 20Page 23 of 107
1 That result reflects a basic physical reality on the Company’s distribution system: there is 2 massive spare capacity in the feeders that deliver electricity to customers. Figure 11 ranks every 3 feeder on Eversource’s distribution system by how close its peak demand comes to its rated 4 capacity, from most to least utilized: 14 Eversource's feeders have massive headroom— only 0% exceed capacity at peak 160% 140% 0.2% exceed rated capaci ty Peak load (% of rated capacity) 120% 100% 80% 60% Median utilization: 49% 40% 20% 0% 0 250 500 750 Feeders (ranked by peak load as % of capacity) Figure 11: Peak demand as a percentage of rated capacity for every feeder on Eversource CT’s distribution system, ranked from most to least utilized. The gray line marks 100% of rated capacity. Source: Eversource response to System Data Requirement No. 2. Of the 918 feeders with loading data, only 2 feeders — 0.2% — have peak demand that 5 6 exceeds their rated capacity. Those feeders serve just 4,903 customers, or 0.4% of the 7 Company’s 1,218,177 customers on feeders with data. The median feeder operates at just 49% of 8 capacity, meaning the typical feeder has 51% headroom even at its annual peak. Data from the Company’s response to System Data Requirement No. 2, OCC-365, Attachment 28, Docket No. 26-05-10. Peak demand is the most recent available annual maximum loading (2025 where reported, otherwise 2024). Capacity is the feeder’s rated capacity in KVA. 14 21Page 24 of 107
1 The Company has not yet provided data identifying whether each feeder’s peak occurs in 2 summer or winter. 15 Until that data is produced, I have conservatively assumed that the peaks 3 shown in Figure 11 are summer peaks. 16 Under that assumption, the chart depicts the distribution 4 system at its most stressed — and even then, the vast majority of feeders have substantial spare 5 capacity. 6 In winter, the headroom is certainly even greater. Connecticut is a summer-peaking 7 system: virtually every home and business has air conditioning, which drives the summer peak. 8 By contrast, fewer than 18% of Connecticut households heat with electricity — the vast majority 9 heat with natural gas and fuel oil, loads that the electric grid does not carry at all. 17 The winter 10 electric peak is therefore almost certainly well below the summer peak across the Company’s 11 distribution system, which means the headroom shown in Figure 11 — already substantial — 12 would be even larger in winter. This is consistent with the MCOS study assigning near-zero 13 marginal distribution costs to winter hours: there is simply no capacity pressure on the 14 distribution grid during the heating season. 15 Q. Is the bill increase that customers pay for distribution and transmission after installing 16 heat pumps under Rate 1 justified by the additional T&D costs they cause after making 17 this transition? We requested summer and winter peaks through discovery but the Company has not yet provided it. What was provided is each feeder’s annual maximum and minimum demand across the past five years, without identifying the date, hour, or season at which the peak occurred. 15 The Company reported each feeder’s annual maximum demand but did not identify the season. Connecticut is a summer-peaking system, so most feeders’ annual peaks almost certainly occur in summer. Even if some turn out to be winter peaks, this makes our headroom estimate more conservative, not less: the annual maximum is by definition higher than the winter peak alone, so the true winter headroom on those feeders would be even greater than what Figure 11 shows. 16 U.S. Census Bureau, American Community Survey 1-Year Estimates (2023), Table B25040, “House Heating Fuel.” In Connecticut, 34% of occupied housing units heat with utility gas, 32% with fuel oil, and 18% with electricity (including both heat pumps and electric resistance). 17 22Page 25 of 107
1 A. No, these customers are being overcharged. 2 Under the cost-causation principle, these customers should pay for that additional $10 in 3 new T&D costs they cause, on average — but no more. Yet under proposed Rate 1, their 4 distribution and transmission charges increase by $1,051 per year — roughly 102 times the new 5 T&D costs they actually cause. 6 Figure 12 shows the gap between the incremental T&D charges that the average fossil 7 fuel-heated customer pays after installing heat pumps, and the incremental marginal T&D costs 8 they cause. 18 Figure 12: Change in annual T&D costs caused vs. T&D charges paid when a fossil fuelheated home installs a heat pump under proposed Rate 1. 9 At present, fossil fuel-heated customers that install heat pumps overpay by an average of 10 $1,040 a year — an amount equal to 44% of their entire post-heat-pump T&D bill. 19 This is a 11 gratuitous surcharge that penalizes customers who electrify their heating, in order to lower the Charges computed by applying Eversource’s proposed Rate 1 tariff to the same representative sample of residential load profiles. Costs from the hourly marginal-cost schedule described in Exhibit JPV-2, Section 3. See Exhibit JPV-2, Section 4 for the full methodology. 18 19 $1,040 overcharge ÷ $2,377 total post-heat-pump T&D bill = 44%. 23Page 26 of 107
1 bills of customers who continue to heat with fossil fuels. (See next question for an explanation of 2 how this transfer occurs.) 3 Q. You’ve shown that fossil fuel-heated customers are overpaying for T&D by $1,040 a 4 year — on average. Does the overpayment vary by customer? 5 A. Yes, it varies significantly. Figure 13 shows the entire distribution of annual T&D 6 overpayments across all fossil fuel-heated customers in the Company’s territory after switching 7 to heat pumps, under the proposed Rate 1 tariff. 20 8 Overpayments are defined as each customer’s incremental T&D charges (from Rate 1 9 being applied to their heat pump’s incremental load), minus their incremental T&D marginal cost 10 (the additional new T&D costs caused by that incremental load during peak hours). Figure 13: Annual delivery overpayment for all fossil fuel-heated CT Eversource homes switching to heat pumps, under proposed Rate 1. 11 The overpayment here is calculated as their total delivery bill after they install heat 12 pumps, minus the sum of the incremental marginal costs caused by the installation and their total Per-building overpayment = incremental delivery revenue − incremental delivery marginal cost. Positive values indicate the customer is being overcharged; negative values indicate the customer is being undercharged. See Exhibit JPV-2, Section 4. 20 24Page 27 of 107
1 delivery bill before the installation. Positive values indicate overpayment — that customer is 2 being charged above their incremental marginal cost; negative values indicate underpayment. 0 3 indicates a customer whose post-heat pump bill only increases by the costs they cause due to the 4 heat pump, their incremental marginal costs. Under a perfectly fair rate (from a cost-causation 5 perspective), all customers would be at 0. 6 Figure 13 confirms that overcharging is the norm, not the exception: virtually all fossil 7 fuel-heated homes that switch to heat pumps are being overcharged for transmission and 8 distribution, with most overpaying between several hundred and well over a thousand dollars per 9 year. 10 The overpayment distribution is right-skewed — some homes overpay far more than the 11 average — because homes with larger heating loads add more incremental kWh, and each of 12 those kWh is charged at the full volumetric rate regardless of whether it causes new 13 infrastructure costs. 14 Q. Why do fossil fuel-heated customers who install heat pumps end up being overcharged 15 for T&D under Rate 1? 16 A. Under the cost-causation principle, if a customer’s usage does not cause new costs, they 17 should not be charged as though it does. Rate 1 does exactly that: it charges the same volumetric 18 rate for every kWh — whether that kWh flows over the grid at 2 a.m. in January, when the 19 system has abundant spare capacity, or at 5 p.m. on the hottest day of the year, when the system 20 is strained. 21 22 When a customer installs a heat pump and adds 6,432 kWh per year, the tariff treats every one of those kWh as though it triggers new infrastructure investment. But 97% of those 25