Page 3 of 107
1 I. INTRODUCTION 2 Q. Please state your name, business address, and occupation. 3 A. My name is Juan-Pablo Velez, and my business address is 461 W 126th St #5W, New York, 4 NY 10027. I am the Founder and Executive Director of Switchbox. 5 Q. Please describe Switchbox. 6 A. Switchbox is a research non-profit that produces quantitative evidence on the impact of state 7 clean energy policies, with expertise in economics, energy modeling, and regulatory issues. Our 8 clients have included Environmental Defense Fund, Natural Resources Defense Council, 9 Earthjustice, Acadia Center, Green Energy Consumers Alliance, Rewiring America, and others. 10 Our reports have been covered by numerous national and local press outlets. 11 Q. Please summarize your education and professional experience. 12 A. I have a BA in Sociology from the University of Chicago. I took post-graduate math courses 13 in probability theory, mathematical statistics, and vector calculus at Columbia University and 14 NYU. 15 Before founding Switchbox, I was a staff machine learning engineer at Spotify, where I 16 helped build some of the company’s large-scale AI systems. Before that, I worked as a data 17 scientist for a boutique data science consultancy called Polynumeral. 18 I founded and have led Switchbox for the past four years, where I have authored reports 19 covering heat pump rates, building electrification and weatherization incentive programs, green 20 hydrogen blending, non-pipeline alternatives, the economics and grid impacts of all-electric new 21 construction mandates, and other topics. Our reports are based on quantitative economics and 22 engineering models, implemented in software. 1Page 4 of 107
1 I have presented our work on heat pump rate design at Northeast Energy Efficiency 2 Partnership’s annual Heating Electrification Workshop and before the Illinois Commerce 3 Commission. 4 Q. Have you previously testified before the Connecticut Public Utilities Regulatory 5 Authority? 6 A. No. 7 Q. Have you previously testified in regulatory proceedings before other state Public 8 Utilities Commissions? 9 A. Yes. I submitted expert testimony to the Maryland Public Service Commission (MDPSC) on 10 heat pump rates in September 2026 (Case 9888), the Rhode Island Public Utilities Commission 11 (RIPUC) on heat pump rates in March 2026 (Case 25-45-GE), and to the Illinois Commerce 12 Commission (ICC) on Non-Pipeline Alternatives in May 2026 (Case 26-0065). 13 14 15 In addition, Switchbox’s reports have been submitted as evidence by intervenors in regulatory proceedings across multiple states, including: • 16 17 Case No. 24-E-0165 before the New York State Public Service Commission (NYPSC), on heat pump rates • 18 Case No. 25-08 before the Massachusetts Department of Public Utilities (DPU), on heat pump rates 19 • Case No. 24-15 before the DPU, on tiered low-and-moderate income (LMI) discounts 20 • Case No. 24-194 before the DPU, on National Grid’s targeted electrification pilot 21 22 23 proposal • Case No. GR23030102 before the New Jersey Board of Public Utilities, on green hydrogen blending in gas distribution 2Page 5 of 107
1 • 2 3 Case No. 24-0158 before the Illinois Commerce Commission (ICC), the state’s Future of Gas proceeding • 4 The People’s Gas Non-Pipeline Alternatives workshop resulting from the ICC’s order in Case No. 24-0081 5 • Case No. 18-M-0084 before the NYPSC, on the state’s energy efficiency programs 6 • Case No. 25-M-0149 before the NYPSC, on the state’s implementation of the All- 7 Electric Building Act 8 Q. On whose behalf are you testifying in this proceeding? 9 A. I am testifying on behalf of Conservation Law Foundation and Sierra Club. 10 Q. What is the purpose of your testimony? 11 A. To demonstrate that the Company’s R1 residential rates are overcharging heat pump 12 customers in violation of cost causation principles and the state’s policy goals; to critique the 13 Company’s proposed rate for heat pump customers, R6; and to propose an alternative rate design 14 for heat pump customers, Rate HP, that eliminates the overcharge by lowering volumetric rates 15 for distribution and transmission. 16 Q. How is your testimony organized? 17 A. My testimony is organized into the following sections: 18 • Section I introduces my qualifications and the scope of my testimony. 19 • Section II summarizes my findings and recommendations to the Authority. 20 • Section III documents how CL&P’s current residential rates overcharge heat pump 21 customers relative to their cost-causation, creating a cross-subsidy within the residential 22 class. I show that generation charges track costs fairly, but distribution and transmission 23 charges do not. 3Page 6 of 107
1 • Section IV shows how this overcharge undermines Connecticut’s building electrification 2 goals. Under current rates, the average natural gas-heated household — the largest group 3 of fossil fuel-heated customers — would see its total energy bills increase after switching 4 to a heat pump, turning what should be a savings opportunity into an operating cost 5 penalty. 6 • 7 8 its overall impact on overpayments and customer bills. • 9 10 Section V introduces the Company’s proposed Rate 6 heat pump rate, its structure, and Section VI shows that Rate 6 unduly discriminates against customers who heat with natural gas and customers who installed heat pumps before 2026. • Section VII shows that Rate 6’s discount is far too low to eliminate the overcharge, and 11 that the Company has not justified setting the discount so close to the ceiling rather than 12 the marginal cost floor. 13 • Section VIII demonstrates that Rate 6’s block rate design is regressive — directing more 14 of the discount to higher-income households — because lower-income customers have 15 lower base loads and therefore capture less of the Block 2 discount. 16 • Section IX shows that Rate 6’s block structure is systematically biased against natural 17 gas-heated customers, who also have lower base loads, and that no single threshold can 18 fix these problems. 19 • Section X presents my proposed remedy: Rate HP, a new residential rate schedule for 20 heat pump customers that eliminates the overcharge by lowering winter volumetric rates 21 for distribution and transmission. 22 • Section XI shows the impact of Rate HP on heat pump customers’ energy bills. 4Page 7 of 107
1 • 2 3 Section XII describes how customers would be enrolled in Rate HP through automatic enrollment. • Section XIII discusses alternative rate designs and explains why I recommend a seasonal 4 volumetric reduction over redesigning the default rate, raising the fixed charge, or 5 layering on time-of-use price signals. 6 • Section XIV concludes my testimony. 7 • Section XV is a list of references. 8 II. SUMMARY AND RECOMMENDATIONS 9 Q. Please summarize your findings to the Authority. 10 A. I demonstrate that the volumetric rates associated with the Company’s default residential 11 tariff (Rate 1) are overcharging heat pump customers relative to costs they cause when adopting 12 a heat pump. This creates a substantial cross-subsidy within the residential customer class, which 13 flows from electric customers that heat with heat pumps to those that heat with fossil fuels. 14 To establish this, I provide evidence that CL&P’s electric customers with heat pumps are 15 overcharged by an average of $1,040 per year on distribution and transmission — far in excess 16 of any marginal infrastructure costs their heat pumps actually cause. 17 Charging heat pump customers far in excess of their cost-causation has two serious 18 consequences: first, it violates intra-class equity, one of the key principles of cost-of-service 19 ratemaking. Second, it undermines the state’s ambitious building policy goals: as a direct result 20 of being overcharged, only 57% of CL&P’s electricity customers that heat with fossil fuels can 21 currently lower their energy bills by switching to heat pumps. 22 23 To stop overcharging heat pump customers, I propose that the Company create a new rate schedule for heat pump customers, Rate HP, with lower volumetric rates for distribution and 5Page 8 of 107
1 transmission during the winter months. The purpose of lowering these rates is to decrease the 2 total revenue collected from heat pump customers for distribution and transmission, in order to 3 bring the incremental revenue collected from customers installing heat pumps in line with the 4 incremental marginal costs they cause. 5 By better aligning rates for heat pump customers with their actual cost-causation, this 6 proposal would eliminate the significant cross-subsidy that exists between heat pump and fossil- 7 heating electric residential customers, thus making the Company’s rates more fair. As our 8 analysis shows, this proposal would also make it cheaper to heat with heat pumps than fossil 9 fuels for 83% of Connecticut households, thus eliminating a key obstacle to the state’s building 10 electrification goals. 11 Q. Please summarize your recommendations to the Authority. 12 A. I recommend that the Authority: 13 14 15 1. Create a new residential rate schedule, Rate HP, for Company electric customers who use a heat pump for heating. 2. Set a lower Distribution Energy Charge for Rate HP during the winter months 16 (November through March), compared with Rate 1. The rate should be set at a level that 17 reflects the distribution cost-of-service of heat pump customers, and ends cost over- 18 recovery from these customers. At present, we estimate that the winter Distribution 19 Energy Charge should be 71% lower than Rate 1’s Distribution Energy Charge. 20 3. Set a lower Transmission Service Rate under the Transmission Adjustment Clause for 21 Rate HP during the winter months, compared with Rate 1. The rate should be set at a 22 level that reflects the bulk transmission cost-of-service of heat pump customers, and ends 23 cost over-recovery from these customers. At present, we estimate that the winter 6Page 9 of 107
1 Transmission Service Rate should be 75% lower than Rate 1’s Transmission Service 2 Rate. 3 4. Auto-enroll all electric customers newly installing heat pumps into schedule Rate HP, at 4 the time of installation. Customers would be identified through any existing or new 5 programs that track heat pump adoption, while also offering an attestation and 6 certification option for installation that may happen outside of these programs. 7 5. Auto-enroll all known electric customers that have previously installed heat pumps into 8 schedule Rate HP. 9 6. Recalibrate the delivery service and transmission rates associated with Rate HP in 10 subsequent rate cases or relevant proceedings, to reflect the evolving marginal 11 distribution and transmission costs associated with heat pump customers as adoption 12 grows and grid conditions change. 13 Q. Have you prepared exhibits to accompany your testimony? 14 A. Yes. I have prepared Exhibits JPV-1 through JPV-4: 15 • JPV-1: Curriculum Vitae of Juan-Pablo Velez 16 • JPV-2: Data Sources and Methodology 17 • JPV-3: Representative Home Load Profile 18 • JPV-4: HP Rate Derivation 19 III. HOW THE COMPANY IS OVERCHARGING HEAT PUMP CUSTOMERS 20 Q. How much electricity do the Company’s residential customers that heat with fossil fuels 21 consume over the course of the year? 7Page 10 of 107
1 A. Residential customers that heat with fossil fuels consume an average of 7,211 kWh of 2 electricity per year. 1 Figure 1 shows this consumption broken down by month. Figure 1: Average monthly electricity consumption for simulated Eversource CT residential electric customers who heat with natural gas, heating oil, or propane. 3 On average, residential customers that heat with fossil fuels use slightly more electricity 4 in the summer — primarily for air conditioning. 5 Q. How much do the Company’s residential customers that heat with fossil fuels pay for 6 this electricity per year? 7 Figure 2 shows the average annual bill for residential customers on Rate 1 that heat with fossil 8 fuels, broken down by charge type. 2 Average monthly consumption was calculated from a sample of 3,539 residential buildings from NREL’s 2024 ResStock residential building energy simulations (NREL 2024b), which model each home’s heating fuel and equipment. I relied on ResStock because the Company does not have this information for its own customers. Asked in discovery for hourly residential load profiles broken out by heating fuel, the Company stated that it “does not track heating sources.” Response to CLF-SC-009, Docket No. 26-05-10 (Sept. 18, 2026) (Eversource, Parsons, and Davis 2026). Asked separately for hourly usage of heat-pump customers, the Company stated that it “does not employ AMI meters and does not have the data requested.” Response to CLF-SC-008, Docket No. 26-05-10 (Sept. 18, 2026) (Eversource, Davis, and Parsons 2026). While the Company was able to provide calculated hourly loads by rate class, my analysis requires residential load profiles broken out by heating fuel and equipment, which are mixed within rate classes. The ResStock sample is statistically representative of Connecticut’s building stock, geographically filtered to Eversource’s service territory. 1 Electricity bills computed by applying Eversource’s proposed Rate 1 tariff to a representative sample of residential load profiles from ResStock 2024. See Exhibit JPV-2, Section 2. 2 8Page 11 of 107
Figure 2: Annual electric bill breakdown by component for fossil fuel-heated homes in Eversource CT’s territory, before heat pump installation. 1 On average, they pay a total of $2,078 per year, broken down as follows: 2 • $148 in fixed monthly customer charges, 3 • $814 for distribution, collected by the Distribution Service Rate and its associated riders (ESI, RDM, SBC, etc.) in Rate 1, 3 4 5 • 6 $364 for transmission, collected by the Transmission Charge under the Transmission Adjustment Clause in Rate 1, and 7 • $752 for generation, collected by the Generation Service Charge in Rate 1. 8 Q. When residential customers that heat with fossil fuels install heat pumps, how does their 9 electricity consumption change? Beyond the distribution energy charge and transmission, Rate 1’s volumetric delivery rate carries several passthrough riders: the Competitive Transition Assessment (CTA) and the Public Benefits charges — Systems Benefits Charge (SBC), Conservation Adjustment Mechanism (CAM), Renewable Energy, and the non-bypassable FMCC Delivery Charge. Each adjusts through its own reconciliation clause rather than this rate case; at their filed values (Exhibit CLP-RATES-3, Docket No. 26-05-10) (Eversource 2026f) they total -0.911 ¢/kWh. 3 9Page 12 of 107
1 A. When these customers install heat pumps, they shift their primary heating fuel from fossil 2 fuels to electricity, leading to a significant change in their monthly load shape. Figure 3 shows 3 the result. 4 Figure 3: Average monthly electricity consumption for simulated Eversource residential electric customers, before (dark yellow: non-electric heating) and after (light yellow: electric heating) heat pump installation. 4 On average, their electricity usage grows by 6,432 kWh per year (89%) after replacing 5 their fossil heating system with a heat pump, from 7,211 to 13,643 kWh per year. 97% of this 6 incremental usage occurs between October and April, due to the electrification of their heating 7 load. 8 The smaller increase between May and September reflects the fact that not all of these 9 homes currently have full air conditioning. Installing a heat pump provides cooling capacity to Same data sources as Figure 1: ResStock 2024.2 modeled load profiles for Eversource’s service territory. “Before” is the baseline (pre-retrofit) population; “after” is the same buildings retrofitted with high-efficiency cold-climate air-source heat pumps with electric resistance backup — variable speed, 90% capacity retention at 5°F, SEER2 19 / HSPF2 9.4 (ducted) or SEER2 20 / HSPF2 9.9 (ductless) (Upgrade 2 in the ResStock 2024.2 release). See Exhibit JPV-2, Section 2. 4 10
Text of JPV-1.pdf
Extracted from the file · 2 pages · 2,718 characters
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Juan-Pablo Velez [26-05-10]