  1. Page 51 of 107

    1 Figure 22 compares the distribution of annual delivery overpayments under Rate 1 (top) 2 and Rate 6 (bottom), using the same methodology as Figure 13 in Section III. 3 The entire histogram shifts left — confirming that Rate 6 does provide some relief — but the 4 bulk of the distribution remains well above zero. As designed, Rate 6 narrows the overcharge; it 5 does not come close to eliminating it. 6 Q. Does Rate 6’s modest reduction in the overcharge significantly improve bill outcomes 7 for natural gas-heated customers who switch to heat pumps? 8 A. Rate 6 barely moves the needle. Figure 23 compares the bill outcomes for natural gas-heated 9 homes installing heat pumps under three scenarios: Rate 1 (the status quo), Rate 6 (the 10 Company’s proposal), and a fair rate that perfectly eliminates the overcharge for every customer. How bills would change for natural gas heated homes after switching to heat pumps , under different rates LOSE > $1K LOSE $0-1K SAVE $0-1K 14.0% 73.5% 12.6% OSE > $1K LOSE $0-1K SAVE $0-1K 5.1% 78.3% 16.3% LOSE $0-1K SAVE $0-1K SAVE > $1K 14.2% 75.5% 10.3% Rate 1 Rate 6 Fair rate Figure 23: Change in total annual energy bill for natural gas-heated CT Eversource homes switching to a heat pump, under Rate 1 vs. Rate 6 vs. a fair rate that eliminates the overcharge. 11 12 Under Rate 1, only 13% of natural gas-heated customers would see lower total energy bills after switching to a heat pump. 49
  2. Page 52 of 107

    1 Under Rate 6, 17% of natural gas-heated customers would save — only a 4% point 2 improvement over Rate 1, and still leaving the vast majority of customers in the red after 3 switching. Under a rate that fully eliminates the overpayment, 86% of natural gas-heated 4 customers would save by switching — a 73% point improvement over Rate 1, and a complete 5 transformation of heat pump economics. 6 Another way to evaluate Rate 6 is to compare each rate’s average bill change. Under Rate 7 1, the average natural gas-heated customer’s annual bill would increase by $463 after switching; 8 under a fair rate, it would decrease by $402. In other words, if these customers stopped being 9 overcharged, we would expect the average customer’s bill outcome to improve by $865 10 compared to Rate 1. Under Rate 6, the average annual bill would still increase, by $306 — an 11 improvement of just $156 over Rate 1, or less than a fifth of that $865 improvement. 12 Q. What is the impact of Rate 6 for delivered fuel-heated customers who switch to heat 13 pumps? 14 A. The pattern is the same, though the starting point is more favorable because delivered fuels 15 are more expensive than natural gas. Figure 24 shows the same three-way comparison for oil- 16 and propane-heated homes. 50
  3. Page 53 of 107Match

    How bills would change for oil/propane heated homes after switching to heat pumps , under different rates LOSE $0-1K SAVE $0-1K SAVE > $1K 9.8% 69.7% 20.5% OSE $0-1K SAVE $0-1K SAVE > $1K 6.4% 53.1% 40.6% SAVE $0-1K SAVE > $1K 23.7% 76.2% Rate 1 Rate 6 Fair rate Figure 24: Change in total annual energy bill for oil/propane-heated CT Eversource homes switching to a heat pump, under Rate 1 vs. Rate 6 vs. a fair rate that eliminates the overcharge. 1 Under Rate 1, 90% of delivered fuel-heated customers would already see lower total 2 energy bills after switching to a heat pump. Under Rate 6, 94% would save — a 3% point 3 improvement. Under a fair rate, 100% of customers would save. But since most delivered fuel 4 customers already save under Rate 1, the key question about Rate 6 is not whether they save, but 5 by how much they save. 6 To evaluate this, we can compare the average bill change under each of these rates. 7 Under proposed Rate 1, the average delivered fuel customer saves $628 per year after switching; 8 under a fair rate, they would save $1,796. In other words, if these customers stopped being 9 overcharged, we would expect their post-heat-pump savings to increase by $1,169, on average. 10 Under Rate 6, they would save $952 — an improvement of $324 over Rate 1, or roughly a 11 quarter of the $1,169 bill improvement a fair rate would deliver to the average customer in this 51
  4. Page 54 of 107

    1 population. In other words: even for the population where heat pumps already tend to pencil out, 2 Rate 6 leaves nearly three-quarters of the potential savings on the table. 3 Q. Can you walk through how the Company arrived at the rate design for Rate 6? 4 A. Yes. The Company’s derivation is documented in Exhibit CLP-RATES-6, the Rate 6 Rate 5 Design Worksheet. It proceeds in two steps: first, raise the fixed charge; second, set the 6 volumetric rates. 7 Step 1 — Increased customer charge. The Company’s MCOS study found that 8 customer-related costs— service lines, meters, billing, and other costs that can be tied to 9 individual customers — are $28.98 per customer per month. Rate 1’s customer charge of $12.36 10 per month recovers less than half of that amount. The Company set Rate 6’s customer charge at 11 $30.95 per month — $28.98 grossed up by the 6.8% Gross Earnings Tax — in a bid to recover 12 (marginal) customer-related costs entirely through the fixed charge. 13 Step 2 — Lowered volumetric rate. Raising the customer charge from $12.36 to $30.95 14 collects an additional $233 million in fixed-charge revenue across the rate class. That reduces the 15 amount that needs to be collected through the volumetric energy charge from approximately 16 $1.03 billion to $796 million. The Company recalculated the volumetric energy charge at 9.431 17 ¢/kWh — down from Rate 1’s 12.196 ¢/kWh. In effect, the Company’s starting point for Rate 6 18 was to redesign Rate 1 to rely less on volumetric energy charges to recover costs, and more on 19 fixed charges. This rebalancing is designed to be revenue neutral within the residential rate class 20 — if all Rate 1 customers (given their existing heating systems) were charged $30.95 per month 21 (instead of $12.36) and 9.431 c/kWh for all kWh (instead of 12.196 c/kWh), the Company would 22 collect the same amount of total revenue from this rate class. 52
  5. Page 55 of 107

    1 Step 3 — Targeting incremental load with a discounted rate. Steps 1 and 2 redesign 2 the rate structure but do not yet provide a discount for heat pump customers — they simply shift 3 how existing residential revenue is collected. The discount comes from the block rate structure 4 the Company layered on top: in winter months (November through March), the first 700 kWh a 5 heat pump customer consumes during a billing period are billed at the Block 1 rate of 9.431 6 ¢/kWh, and any consumption above 700 kWh — which the Company treats as a proxy for the 7 heat pump’s incremental load — is billed at a lower Block 2 rate of 7.517 ¢/kWh. In non-winter 8 months, all kWh are billed at 9.431 ¢/kWh with no discount. 9 10 11 To arrive at the Block 2 rate, the Company decomposed the 9.431 ¢/kWh distribution energy charge that resulted from Step 2 into two sub-charges: • A local facilities charge (3.894 ¢/kWh), which recovers the cost of “local facilities,” i.e., 12 distribution infrastructure sized to serve a small number of neighboring customers — 13 lateral primary conductors, secondary conductors, and primary-to-secondary 14 transformers. The 3.894 ¢/kWh rate was derived from the MCOS marginal facilities cost 15 of $24.51 per customer per month (Eversource 2026c), spread across all billed kilowatt- 16 hours for all Rate 1 customers. 17 • An upstream distribution charge (5.537 ¢/kWh), which recovers the cost of upstream 18 distribution infrastructure shared by hundreds to thousands of customers — bulk 19 substations, local transmission line, distribution substations, trunkline primary feeders, 20 etc. — whose expansion is driven by growth in each component’s peak load. Table 2: Rate 6 Block 2 distribution charge decomposition (Source: Exhibit CLP-RATES-6) 53
  6. Page 56 of 107

    1 2 The Company did not discount the local facilities charge at all — it remains at 3.894 ¢/kWh in both Block 1 and Block 2. 3 Only the upstream distribution charge was discounted, by 1.914 ¢/kWh. We discuss why 4 this discount is insufficient below. 5 Q. What problems do you see with the design of Rate 6 as proposed? 6 A. I claim that the Company should aim to eliminate overpayments for all customers who choose 7 to switch to heat pumps. From that perspective, I see three problems with the Company’s Rate 6 8 design: 9 1. Rate 6 excludes natural gas-heated customers. 10 2. Rate 6 unduly discriminates against customers who installed heat pumps before 2026. 11 3. The volumetric rate discounts are too low: the discount on upstream distribution rate is 12 too small; volumetric local facilities and transmission rates are not being discounted at 13 all. 14 4. A block rate with a one-size-fits-all threshold is regressive. 15 5. A block rate with a one-size-fits-all threshold is biased against natural gas-heated 16 17 customers. I will address each of these in turn. 54
  7. Page 57 of 107Match

    1 VI. RATE 6 EXCLUDES CUSTOMERS COMING FROM NATURAL GAS OR WHO 2 INSTALL HEAT PUMPS BEFORE 2026 3 Q. Why does the Company exclude natural gas-heated customers from their proposed Rate 4 6? 5 A. When asked by CLF intervenors why the proposed Rate 6 is not available to customers 6 converting from natural gas, the Company responded that it “designed the rate to avoid 7 encouraging conversions that would likely result in higher customer household energy.” 53 The 8 Company explained that “for customers heating with natural gas, conversion to a heat pump 9 typically increases the household’s total energy bill at current prices,” 54 and that therefore “while 10 natural gas conversions may produce emissions benefits, Rate 6 is designed to deliver bill 11 savings, and eligibility was scoped accordingly.” 55 12 Q. Is the Company’s reasoning for excluding natural gas customers sound? 13 A. No. The Company’s reasoning is circular. As I have just shown, the reason natural gas 14 customers’ total energy bills typically increase after switching to a heat pump is the overcharge 15 documented in Section III — the gap between what these customers pay in incremental T&D 16 charges and the incremental T&D costs their heat pumps actually cause. 53 Response to CLF-002(b), Docket No. 26-05-10 (Sept. 3, 2026) (Eversource 2026a). 54 Response to CLF-002(b), Docket No. 26-05-10 (Sept. 3, 2026) (Eversource 2026a). 55 Response to CLF-002(b), Docket No. 26-05-10 (Sept. 3, 2026) (Eversource 2026a). 55
  8. Page 58 of 107

    How bills would change for natural gas heated homes after switching to heat pumps : Rate 1 vs. Fair rate LOSE > $1K LOSE $0-1K SAVE $0-1K 14.0% 73.5% 12.6% LOSE $0-1K SAVE $0-1K SAVE > $1K 14.2% 75.5% 10.3% Rate 1 Fair rate Figure 25: Change in total annual energy bill for natural gas-heated CT Eversource homes switching to a heat pump, under Rate 1 vs. a fair rate that eliminates the overcharge. 1 2 As I showed in Section IV, under a fair rate that eliminates the overcharge, 86% of natural gas-heated customers would save money by switching. 56 3 The Company is aware that heat pump customers are being overcharged — it is the entire 4 basis on which it justifies Rate 6. 57 Yet it uses the consequences of the overcharge — higher bills 5 for natural gas customers who switch — as the reason not to stop overcharging them. In effect, 6 the Company is saying: we cannot stop overcharging these customers, because if we did, it 7 would encourage them to switch to heat pumps, and switching to heat pumps raises their bills — 8 because we overcharge them. 9 In other words: the Company has identified a problem (the gap between Rate 1 and 10 marginal cost) created by status-quo rates, proposed an insufficient fix (Rate 6), and then 11 excluded the customers most harmed by the problem from the fix — on the grounds that the 12 problem harms them. 56 See Figure 25 in Section IV. 57 See Section III, above, “Is the Company aware that overpayments from heat pump customers contribute to a cross-subsidy within the residential customer class which violates intra-class equity?”. 56
  9. Page 59 of 107

    1 If instead the Company followed its own premises to their conclusions — that the 2 discount can legitimately extend to the marginal-cost floor, for both transmission and 3 distribution, without shifting costs to other customers (indeed, by simply unwinding an unfair 4 cost-shift that exists in the other direction) — it could offer offer a rate to heat pump customers 5 that still makes them pay for any additional costs they impose on the system. And it turns out 6 that by making rates fair, the Company could transform heat pumps into a reliable way to cut 7 heating bills for the vast majority of natural gas customers, too. 8 Q. Does Rate 6 exclude other types of heat pump customers? 9 A. Yes. As proposed, Rate 6 is available only to customers who installed heat pumps on or after 10 January 1, 2026 (and who previously heated with delivered fuels). Customers who installed heat 11 pumps before that date — even though they are already being overcharged under Rate 1, by the 12 same amount and for the same reasons as post-2026 adopters — are ineligible. 13 Q. Is there any cost-causation basis for this cutoff? 14 A. No. The date a customer installs a heat pump has no bearing on the costs currently caused by 15 that customer’s yincremental load. A kWh consumed by a heat pump installed in December 2025 16 imposes exactly the same marginal distribution and transmission costs going forward as a kWh 17 consumed by a heat pump installed in January 2026. Both customers add load to the same 18 substations and feeders, and both are served under the same physical conditions. The installation 19 date is entirely irrelevant to cost causation. 20 Q. Does this cutoff constitute undue discrimination? 21 A. Yes. Rate-making principles have long held that charging different rates to customers who 22 receive substantially the same service, under similar conditions, at the same cost of service, 57
  10. Page 60 of 107

    1 constitutes undue discrimination. The standard references on public utility rate design are 2 uniform on this point. 3 Bonbright identifies what he calls “personal discrimination” — “whereby different 4 customers are charged different rates for substantially the same service, rendered under similar 5 conditions” — as the most overt form of rate discrimination, one that public utility statutes forbid 6 “without qualification.” 58 He further observes that there is “general agreement” among 7 economists that “the practice of exacting different charges for different classes of service 8 rendered at the same marginal costs constitutes discrimination.” 59 Rate 6’s eligibility cutoff fails 9 both tests: pre-2026 and post-2026 heat pump customers receive physically identical service at 10 the same marginal cost, yet are charged different rates. 11 The Regulatory Assistance Project’s widely referenced manual on electric cost allocation 12 warns that when regulators adopt differential treatment of new versus existing loads, they 13 “should be careful to ensure adoption of such techniques is not arbitrary or discriminatory and is 14 grounded in solid reasoning.” 60 RAP’s examples of legitimate differential treatment — Seattle 15 City Light’s 1980 cost allocation, the Bonneville Power Administration’s pricing for new large 16 single loads, Chelan County’s bitcoin mining tariff — all involve situations where new loads 17 genuinely impose different costs on the system, typically because they drive the need for 18 expensive new resources. 61 Here, the costs are the same. The cutoff has no grounding in cost-of- 19 service analysis; it is arbitrary. 58 James C. Bonbright, Principles of Public Utility Rates (New York: Columbia University Press, 1961), Ch. XIX (“Discrimination, Due and Undue”). 59 Id. Jim Lazar, Paul Chernick, and William Marcus, Electric Cost Allocation for a New Era: A Manual, Regulatory Assistance Project (January 2020), Ch. 16. 60 61 Id., Ch. 16, §16.2. 58

Text of JPV-1.pdf