Prefiled testimony
Witness: Juan-Pablo Velez
Files5
Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
PDF · 5.8 MB · 107 pagesText searchable
Download Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdfRead the text of Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
Search terms highlighted
Eversource rate increase is on 13 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Page 7 of 107
1 • 2 3 Section XII describes how customers would be enrolled in Rate HP through automatic enrollment. • Section XIII discusses alternative rate designs and explains why I recommend a seasonal 4 volumetric reduction over redesigning the default rate, raising the fixed charge, or 5 layering on time-of-use price signals. 6 • Section XIV concludes my testimony. 7 • Section XV is a list of references. 8 II. SUMMARY AND RECOMMENDATIONS 9 Q. Please summarize your findings to the Authority. 10 A. I demonstrate that the volumetric rates associated with the Company’s default residential 11 tariff (Rate 1) are overcharging heat pump customers relative to costs they cause when adopting 12 a heat pump. This creates a substantial cross-subsidy within the residential customer class, which 13 flows from electric customers that heat with heat pumps to those that heat with fossil fuels. 14 To establish this, I provide evidence that CL&P’s electric customers with heat pumps are 15 overcharged by an average of $1,040 per year on distribution and transmission — far in excess 16 of any marginal infrastructure costs their heat pumps actually cause. 17 Charging heat pump customers far in excess of their cost-causation has two serious 18 consequences: first, it violates intra-class equity, one of the key principles of cost-of-service 19 ratemaking. Second, it undermines the state’s ambitious building policy goals: as a direct result 20 of being overcharged, only 57% of CL&P’s electricity customers that heat with fossil fuels can 21 currently lower their energy bills by switching to heat pumps. 22 23 To stop overcharging heat pump customers, I propose that the Company create a new rate schedule for heat pump customers, Rate HP, with lower volumetric rates for distribution and 5Page 8 of 107
1 transmission during the winter months. The purpose of lowering these rates is to decrease the 2 total revenue collected from heat pump customers for distribution and transmission, in order to 3 bring the incremental revenue collected from customers installing heat pumps in line with the 4 incremental marginal costs they cause. 5 By better aligning rates for heat pump customers with their actual cost-causation, this 6 proposal would eliminate the significant cross-subsidy that exists between heat pump and fossil- 7 heating electric residential customers, thus making the Company’s rates more fair. As our 8 analysis shows, this proposal would also make it cheaper to heat with heat pumps than fossil 9 fuels for 83% of Connecticut households, thus eliminating a key obstacle to the state’s building 10 electrification goals. 11 Q. Please summarize your recommendations to the Authority. 12 A. I recommend that the Authority: 13 14 15 1. Create a new residential rate schedule, Rate HP, for Company electric customers who use a heat pump for heating. 2. Set a lower Distribution Energy Charge for Rate HP during the winter months 16 (November through March), compared with Rate 1. The rate should be set at a level that 17 reflects the distribution cost-of-service of heat pump customers, and ends cost over- 18 recovery from these customers. At present, we estimate that the winter Distribution 19 Energy Charge should be 71% lower than Rate 1’s Distribution Energy Charge. 20 3. Set a lower Transmission Service Rate under the Transmission Adjustment Clause for 21 Rate HP during the winter months, compared with Rate 1. The rate should be set at a 22 level that reflects the bulk transmission cost-of-service of heat pump customers, and ends 23 cost over-recovery from these customers. At present, we estimate that the winter 6Page 9 of 107
1 Transmission Service Rate should be 75% lower than Rate 1’s Transmission Service 2 Rate. 3 4. Auto-enroll all electric customers newly installing heat pumps into schedule Rate HP, at 4 the time of installation. Customers would be identified through any existing or new 5 programs that track heat pump adoption, while also offering an attestation and 6 certification option for installation that may happen outside of these programs. 7 5. Auto-enroll all known electric customers that have previously installed heat pumps into 8 schedule Rate HP. 9 6. Recalibrate the delivery service and transmission rates associated with Rate HP in 10 subsequent rate cases or relevant proceedings, to reflect the evolving marginal 11 distribution and transmission costs associated with heat pump customers as adoption 12 grows and grid conditions change. 13 Q. Have you prepared exhibits to accompany your testimony? 14 A. Yes. I have prepared Exhibits JPV-1 through JPV-4: 15 • JPV-1: Curriculum Vitae of Juan-Pablo Velez 16 • JPV-2: Data Sources and Methodology 17 • JPV-3: Representative Home Load Profile 18 • JPV-4: HP Rate Derivation 19 III. HOW THE COMPANY IS OVERCHARGING HEAT PUMP CUSTOMERS 20 Q. How much electricity do the Company’s residential customers that heat with fossil fuels 21 consume over the course of the year? 7Page 10 of 107
1 A. Residential customers that heat with fossil fuels consume an average of 7,211 kWh of 2 electricity per year. 1 Figure 1 shows this consumption broken down by month. Figure 1: Average monthly electricity consumption for simulated Eversource CT residential electric customers who heat with natural gas, heating oil, or propane. 3 On average, residential customers that heat with fossil fuels use slightly more electricity 4 in the summer — primarily for air conditioning. 5 Q. How much do the Company’s residential customers that heat with fossil fuels pay for 6 this electricity per year? 7 Figure 2 shows the average annual bill for residential customers on Rate 1 that heat with fossil 8 fuels, broken down by charge type. 2 Average monthly consumption was calculated from a sample of 3,539 residential buildings from NREL’s 2024 ResStock residential building energy simulations (NREL 2024b), which model each home’s heating fuel and equipment. I relied on ResStock because the Company does not have this information for its own customers. Asked in discovery for hourly residential load profiles broken out by heating fuel, the Company stated that it “does not track heating sources.” Response to CLF-SC-009, Docket No. 26-05-10 (Sept. 18, 2026) (Eversource, Parsons, and Davis 2026). Asked separately for hourly usage of heat-pump customers, the Company stated that it “does not employ AMI meters and does not have the data requested.” Response to CLF-SC-008, Docket No. 26-05-10 (Sept. 18, 2026) (Eversource, Davis, and Parsons 2026). While the Company was able to provide calculated hourly loads by rate class, my analysis requires residential load profiles broken out by heating fuel and equipment, which are mixed within rate classes. The ResStock sample is statistically representative of Connecticut’s building stock, geographically filtered to Eversource’s service territory. 1 Electricity bills computed by applying Eversource’s proposed Rate 1 tariff to a representative sample of residential load profiles from ResStock 2024. See Exhibit JPV-2, Section 2. 2 8Page 11 of 107
Figure 2: Annual electric bill breakdown by component for fossil fuel-heated homes in Eversource CT’s territory, before heat pump installation. 1 On average, they pay a total of $2,078 per year, broken down as follows: 2 • $148 in fixed monthly customer charges, 3 • $814 for distribution, collected by the Distribution Service Rate and its associated riders (ESI, RDM, SBC, etc.) in Rate 1, 3 4 5 • 6 $364 for transmission, collected by the Transmission Charge under the Transmission Adjustment Clause in Rate 1, and 7 • $752 for generation, collected by the Generation Service Charge in Rate 1. 8 Q. When residential customers that heat with fossil fuels install heat pumps, how does their 9 electricity consumption change? Beyond the distribution energy charge and transmission, Rate 1’s volumetric delivery rate carries several passthrough riders: the Competitive Transition Assessment (CTA) and the Public Benefits charges — Systems Benefits Charge (SBC), Conservation Adjustment Mechanism (CAM), Renewable Energy, and the non-bypassable FMCC Delivery Charge. Each adjusts through its own reconciliation clause rather than this rate case; at their filed values (Exhibit CLP-RATES-3, Docket No. 26-05-10) (Eversource 2026f) they total -0.911 ¢/kWh. 3 9Page 12 of 107
1 A. When these customers install heat pumps, they shift their primary heating fuel from fossil 2 fuels to electricity, leading to a significant change in their monthly load shape. Figure 3 shows 3 the result. 4 Figure 3: Average monthly electricity consumption for simulated Eversource residential electric customers, before (dark yellow: non-electric heating) and after (light yellow: electric heating) heat pump installation. 4 On average, their electricity usage grows by 6,432 kWh per year (89%) after replacing 5 their fossil heating system with a heat pump, from 7,211 to 13,643 kWh per year. 97% of this 6 incremental usage occurs between October and April, due to the electrification of their heating 7 load. 8 The smaller increase between May and September reflects the fact that not all of these 9 homes currently have full air conditioning. Installing a heat pump provides cooling capacity to Same data sources as Figure 1: ResStock 2024.2 modeled load profiles for Eversource’s service territory. “Before” is the baseline (pre-retrofit) population; “after” is the same buildings retrofitted with high-efficiency cold-climate air-source heat pumps with electric resistance backup — variable speed, 90% capacity retention at 5°F, SEER2 19 / HSPF2 9.4 (ducted) or SEER2 20 / HSPF2 9.9 (ductless) (Upgrade 2 in the ResStock 2024.2 release). See Exhibit JPV-2, Section 2. 4 10Page 13 of 107
1 100% of the home, so homes that previously had partial or no air conditioning see a modest 2 increase in summer electricity use. 5 3 The bottom line: on average, when homes in the Company’s territory that heat with fossil 4 fuels install heat pumps, they experience a very minor increase in summer electricity usage, from 5 additional cooling, and a major increase in winter electricity usage, from the full electrification 6 of their heating. 7 Q. How do these customers’ electricity bills change after installing heat pumps? 8 A. Because the Company recovers most costs through volumetric per-kWh charges, the increase 9 in electricity consumption leads to higher annual bills across every line item. Figure 4 shows the 10 result. 6 Because only 34% of the Company’s fossil-fuel-heated customers currently have full cooling coverage, the chart above shows the average change in summer usage, post-heat pump installation, across a representative sample of homes that already had full AC, homes that had partial coverage (e.g., window units in some rooms), and homes that had no cooling at all — each of which sees a different summer increase. This cooling-coverage figure is derived from NREL’s ResStock 2024.2 building stock dataset (NREL 2024b), which assigns cooling equipment characteristics to each simulated dwelling based on probability distributions drawn from the EIA’s 2020 Residential Energy Consumption Survey (RECS) and other federal surveys; the sample is geographically filtered to Eversource CT’s service territory. 5 Same data sources as Figure 2: monthly kWh from ResStock 2024.2 applied to Eversource’s proposed Rate 1 delivery rates (Exhibit CLP-RATES-3, Schedule E-1.1, Docket No. 26-05-10) (Eversource 2026f). See Exhibit JPV2, Section 2. 6 11Page 14 of 107
Figure 4: Annual electric bill breakdown by component for all Eversource fossil fuel-heated homes, before and after heat pump installation. 1 After customers that heat with fossil fuels install a heat pump, their average annual 2 electricity bill rises by $1,736 (84%), from $2,078 to a total of $3,815 per year. The increases 3 break down as follows: 4 • 5 The Customer Charge stays at $148 per year — it is a fixed monthly charge that does not vary with usage 6 • Distribution increases by $726 (89%) per year, from $814 to $1,540 7 • Transmission increases by $325 (89%) per year, from $364 to $689 8 • Generation increases by $686 (91%) per year, from $752 to $1,438 9 The question my testimony addresses is whether all of these bill increases are consistent 10 with cost-causation. 11 Q. What is the principle of cost causation? 12 A. Cost causation is a foundational principle of sound rate design: a utility’s costs should be 13 borne by the customers on whose behalf the costs are incurred. 7 In other words, if a customer’s 14 usage causes a cost, that customer should be charged for it — and if it does not, they should not 15 be charged as though it does. 16 Q. Is the bill increase that customers pay for generation after installing heat pumps 17 consistent with the cost-causation principle? 18 A. Yes. When fossil fuel-heated residential customers install heat pumps, their annual electricity 19 consumption increases by an average of 6,432 kWh. Every one of those new kWh requires the The cost-causation principle originates in the sixth of the eight Bonbright principles of a sound rate structure: “Fairness of the specific rates in the apportionment of total costs of service among the different consumers.” (Bonbright 1961). 7 12Page 15 of 107
1 Company to procure additional electricity supply on the customer’s behalf. In other words, the 2 incremental usage resulting from heat pump adoption directly causes new generation costs: if the 3 customer had not consumed that extra electricity, the Company would not have had to incur the 4 cost of procuring it. Therefore, to satisfy the cost-causation principle, these customers should 5 indeed be charged an additional $686 per year, on average, to cover these incremental generation 6 costs. 7 Q. Is the bill increase that customers pay for distribution and transmission after installing 8 heat pumps consistent with the cost-causation principle? 9 A. No. The Company is currently overcharging heat pump customers for distribution and 10 transmission costs. I will demonstrate this in the following questions. 11 Q. You testified that every kWh of electricity consumption causes generation costs. Does 12 every kWh also cause transmission and distribution (T&D) costs? 13 A. No. 14 For generation, every kWh a customer consumes causes a generation cost: someone has 15 to generate the electricity that customer is consuming, and the Company has to pay for it. This is 16 true at every hour of the year — a kWh consumed at 3 a.m. in February costs money to generate, 17 as does a kWh consumed at 5 p.m. in August. 18 In terms of cost causation, transmission and distribution are fundamentally different from 19 generation: very few of the kWh a customer consumes causes a new (or marginal) T&D cost. 20 Distribution and transmission are networks of existing infrastructure that deliver electricity to 21 customers. When a customer uses electricity, it flows over this existing infrastructure. The vast 22 majority of the time, this flow causes no costs: the infrastructure is already there, and it has the 23 capacity to deliver the load, without the need for capacity upgrades. (And while this existing 13Page 16 of 107
1 infrastructure does need to be paid for, those are sunk costs tied to old investments, not marginal 2 costs, or costs caused by customer usage in the present.) 3 So when does customer usage actually cause new distribution and transmission costs? 4 When the grid is constrained: during the small number of peak hours that a customer’s demand 5 pushes their local distribution feeder/substation, or the upstream bulk transmission system, near 6 its capacity limits. This triggers the need for capacity upgrades — larger transformers, 7 reconductored feeders, etc. — whose costs, according to the cost-causation principle, should be 8 borne by the customers who caused them. 9 Bottom line: unlike generation, only usage during peak hours causes marginal T&D 10 costs to be incurred by the Company. Usage outside of peak hours simply flows over existing 11 infrastructure, without triggering any new investment. 12 Q. You testified that customer usage only causes new T&D costs when it occurs during 13 peak hours. When do the Company’s distribution peak hours occur? 14 A. To answer this, I used the hourly marginal distribution costs the Company provided in its 15 response to OCC-863. Those costs start from the Company’s system-wide marginal upstream 16 distribution cost of $20.17/kW-year, grossed up for secondary losses to $21.22/kW-year. This 17 annualized cost is then allocated using a probability-of-peak analysis prepared by the Company 18 to each combination of month, hour, and day type (weekday vs. weekend.). I placed these 19 $/kWh-year values on the 2025 calendar and scaled them so the year totals $21.22/kW-year 20 (“Docket 26-05-10: Response to OCC-863” 2026). The full methodology is described in Exhibit 21 JPV-2, Section 3. 8 Figure 5 shows the results. As part of this rate case, the Company filed an MCOS study (Eversource 2026c, 2026d) that quantifies three categories of marginal distribution cost: (1) individual customer-related costs ($28.98/month for Rate 1), covering meters, service drops, billing, and customer accounts; (2) local distribution facilities costs ($24.51/customer-month for Rate 1), covering lateral primary conductors, transformers, and secondary conductors sized to the design demand 8 14
Text of JPV-1.pdf
Extracted from the file · 2 pages · 2,718 characters
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Juan-Pablo Velez [26-05-10]