Prefiled testimony
Witness: Juan-Pablo Velez
Files5
Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
PDF · 5.8 MB · 107 pagesText searchable
Download Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdfRead the text of Direct Testimony of Juan-Pablo Velez - Docket No. 26-05-10.pdf
Search terms highlighted
Eversource rate increase is on 13 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
Page 70 of 107
1 1. Discount leakage: when a customer’s base load is below the threshold, some of their 2 incremental heat pump electricity lands in Block 1 at the full rate, and they receive less 3 discount than intended. 4 2. Windfall discount: when a customer’s base load is above the threshold, some of their 5 pre-existing consumption — unrelated to the heat pump — gets the Block 2 discount as 6 an unintended windfall. 7 These misallocations are not specific to the 700 kWh threshold — they are inherent to 8 9 any block design with a fixed cutoff applied to a heterogeneous population. And as I will show, these misallocations produce two concrete harms: 1. the block 10 design is regressive, because lower-income customers have lower base loads; and 2. it is 11 systematically biased against natural gas customers, who also have lower base loads. (The 12 seasonal rate I propose in Section X avoids these two harms entirely, and ultimately does a better 13 job of delivering a discount that is proportional to each customer’s incremental heat pump load.) 14 I will address each of these harms in turn, after providing examples of the misallocations. 15 Q. Can you provide examples to illustrate discount leakage and windfall discount, the two 16 types of discount misallocations introduced above? 17 A. Consider two delivered fuel homes, both of which switch to a heat pump and add the same 18 500 kWh per month of incremental winter electricity. 19 Discount leakage. Home A uses 400 kWh per month before the heat pump — well 20 below the threshold. After the retrofit, it uses 900 kWh. Under Rate 6, the first 700 kWh is billed 21 at the Block 1 rate (13.6 ¢/kWh) and only the last 200 kWh gets the Block 2 rate (11.7 ¢/kWh). 22 Of the home’s 500 kWh of heat pump load, only 200 kWh — 40% — lands in Block 2. The 68Page 71 of 107
1 other 300 kWh is billed at the full Block 1 rate. The discount leaks — it fails to reach most of the 2 incremental heat pump load it was designed for. 3 Windfall discount. Home B uses 900 kWh before the heat pump — well above the 4 threshold. After the retrofit, it uses 1,400 kWh. Under Rate 6, the first 700 kWh is again Block 1, 5 and the remaining 700 kWh gets Block 2. All 500 kWh of heat pump load lands in Block 2, but 6 Home B also gets the Block 2 discount on 200 kWh of its pre-existing base load. That is a 7 windfall — a discount on electricity that has nothing to do with the heat pump. 8 The threshold treats both homes the same, but the economic outcomes are very different: 9 Home A receives 1.9 ¢/kWh of discount on only 40% of its heat pump load, while Home B 10 receives that discount on 100% of its heat pump load plus an additional windfall on existing 11 consumption. 12 Q. How well does the 700 kWh assumption hold for delivered fuel customers? 13 A. Poorly. I examined the distribution of average monthly pre-heat-pump electricity use during 14 winter across the full ResStock sample of delivered fuel-heated customers. Figure 29 ranks every 15 delivered fuel customer from lowest to highest base load, and plots this base load against Rate 16 6’s 700 kWh threshold. 69Page 72 of 107
Figure 29: Pre-heat-pump winter electricity use for delivered fuel homes, ranked by consumption. Dashed line at 700 kWh marks Rate 6’s block threshold. 1 2 The average monthly winter base load for these customers is 671 kWh per month, which matches the 700 kWh threshold well. 3 For the threshold to work well, however, most customers’ base load would need to cluster 4 near 700 kWh. They do not. (The lines in the chart would need to be largely parallel.) Only 22% 5 of delivered fuel homes have a base load between 600 and 800 kWh. (The gray line in 6 Figure 29.) The middle 80% of homes range from 179 to 1,173 kWh — a sixfold spread. With so 7 much variation in customer base load, no single threshold can accurately separate base load from 8 heat pump load for most people. 9 Q. Given this wide variation in base load among delivered fuel-heated customers, how 10 much discount leakage and windfall actually occurs under the 700 kWh threshold? 11 A. Figure 30 adds post-heat-pump consumption to the previous chart. The chart visualizes which 12 homes experience discount misallocations: blue is incremental load correctly in Block 2, orange 70Page 73 of 107
1 is incremental load trapped in Block 1 (discount leakage), and yellow is base load spilling into 2 Block 2 (windfall). Figure 30: How Rate 6’s 700 kWh threshold classifies each delivered fuel home’s load. Blue: HP load correctly in Block 2. Orange: HP load trapped in Block 1. Yellow: base load getting Block 2 windfall. 3 Both misallocation problems are prevalent. 4 Discount leakage (orange) affects 67% of delivered fuel homes — their base load is 5 below 700 kWh, so some of their incremental heat pump load is trapped in Block 1 at the full 6 rate. Among those homes, the median amount of leaked HP load is 169 kWh per month. 7 Windfall discount (yellow) affects 49% — their base load is above 700 kWh, so some of 8 their pre-existing consumption gets the Block 2 discount. Among those homes, the median 9 windfall is 167 kWh per month. 10 Q. Is discount misclassification correlated with income? 11 A. Yes. Among delivered fuel homes, base load and income are positively correlated (weighted 12 Pearson r = 0.44). Higher-income homes tend to be larger, have more appliances, and generally 71Page 74 of 107
1 consume more electricity before installing a heat pump. And this has direct consequences for the 2 discount misallocation. Figure 31 shows the same chart for each income tercile of delivered fuel 3 homes. Figure 31: Rate 6 threshold classification for delivered fuel homes, by income tercile. Lowincome homes (left) bear more orange (trapped HP load); high-income homes (right) receive more yellow (windfall discount). 4 Among low-income delivered fuel homes, 88% experience discount leakage — their base 5 load is below 700 kWh, so much of their HP load is trapped in Block 1 at the full rate. Only 23% 6 receive a windfall. Among high-income homes, the picture reverses: only 50% experience 7 discount leakage (and the leakage is smaller, as a share of their incremental load) while 68% 8 receive a windfall on pre-existing base load. 9 Rate 6’s Block 2 discount is designed to reduce every customer’s incremental heat pump 10 bill by 14.1%, because it lowers the price charged for each of those kWh by 14.1% — from 11 13.570 ¢/kWh to 11.656 ¢/kWh. Because of discount leakage, low-income delivered fuel homes 12 see their incremental HP bills reduced by only 8.0% on average (even after including the 23% of 13 low-income homes that receive a windfall.) High-income homes see a 15.9% reduction in their 72Page 75 of 107
1 incremental HP bills, on average — more than intended, because most get the full discount on 2 their heat pump load, plus an additional windfall on pre-existing base load. 3 Q. Does Rate 6’s block design have a regressive impact? 4 A. Yes. A rate design feature is regressive when it delivers a larger benefit to higher-income 5 customers than to lower-income customers. In this case, the benefit is a proportional bill 6 discount: Rate 6 aims to give all delivered fuel customers a 14.1% discount on their heat pump 7 bill, because it lowers the all-in Block 2 rate by 14.1%. But Rate 6 does not deliver proportional 8 bill discounts to all customers. Instead, the percent reduction in incremental heat pump bills 9 increases with income — 8.0% for the lowest-income third of delivered fuel homes, 13.8% for 10 the middle third, and 15.9% for the highest-income third — against a design target of 14.1% for 11 all. 12 Ultimately, the reason Rate 6’s block design is regressive is straightforward: higher- 13 income homes have higher base loads, which places them above the 700 kWh threshold; lower- 14 income homes have lower base loads, which keeps them below it. The threshold converts the 15 correlation between income and base load into a correlation between income and savings. 16 Q. Could Rate 6’s regressive impact be avoided by choosing a different threshold? 17 A. No. Regressivity is an inherent problem of any block rate with a one-size-fits-all threshold, 18 not just 700 kWh. 19 Moving the threshold lower would reduce leakage but increase windfall; moving it higher 20 would do the reverse. In fact, 700 kWh is close to the threshold that minimizes total 21 misallocation. 68 68 This is because 700 kWh is near the mean base load of delivered fuel homes, and at that point leakage and windfall are roughly equal. 73Page 76 of 107
1 But even when misallocations are minimized, they are far from eliminated, because base 2 loads vary so widely across homes. And the fact that this variation in base load is correlated with 3 income ensures that lower-income people will tend to get discount leaks, and higher-income 4 people will tend to get windfalls — even if the “best” threshold is chosen. 5 Q. In Section VII, you showed that Rate 6’s discount is far smaller than it could be. If the 6 discount were set at the marginal cost floor (as in modified Rate 6), would the regressive 7 impact of the block design go away — since all customers would be getting a much larger 8 benefit? 9 A. No — it gets worse. As I showed above, the threshold systematically gives low-income 10 homes only 57% of their intended savings, while high-income homes get 112%. 69 These 11 percentages arise from the threshold, and do not change with the discount size. However, a 12 bigger discount applied through the same percentages produces a bigger gap in what customers 13 actually receive. 70 14 Under Rate 6 as proposed, the Block 2 discount is 1.9 ¢/kWh, or 14% of the Block 1 rate. 15 As I showed above, low-income homes see an effective bill reduction of only 8%, while high- 16 income homes see 16% — a 8 percentage-point gap, driven entirely by the threshold’s inability 17 to consistently separate base load from heat pump load. A customer’s “intended savings” is what they would receive if the threshold perfectly separated their base load from their heat pump load — that is, if every kWh of incremental HP consumption landed in Block 2 and none of their base load did. The ratio shown (e.g. 57% for low-income homes) is each customers’ actual savings divided by their intended savings, averaged across the customers in an income group. A home with mostly leakage might capture only 20%; a home with a large windfall might capture 150%. The group average tells you whether the threshold delivers the right amount of savings to that population on balance — and for low-income homes, even after including homes that receive windfalls, the answer is barely more than half. 69 The arithmetic: low-income homes capture 57% of their intended savings, so their effective bill reduction is 57% × 72% = 41%. High-income homes capture 112%, so theirs is 112% × 72% = 81%. The same ratios that produced an 8 percentage-point gap under a 14% discount produce a 40 percentage-point gap under a 72% discount. 70 74Page 77 of 107
1 Under the modified Rate 6 I presented in Section VII — with Block 2 rates for upstream 2 distribution, local distribution, and transmission all set at marginal cost — the discount grows to 3 13.4 ¢/kWh, or 72% of the Block 1 rate. If the threshold worked perfectly, every customer’s 4 incremental heat pump bill would fall by 72%. But the same threshold imprecision applies: low- 5 income homes would see only a 41% reduction, while high-income homes would see 81% — a 6 40 percentage-point gap. 71 7 In other words, fixing Problem 1 (the discount being too small) without fixing Problem 2 8 (the block structure misallocating the discount) actually makes the regressivity five times worse 9 in absolute terms. 10 IX. RATE 6’S BLOCK STRUCTURE DISADVANTAGES NATURAL GAS 11 CUSTOMERS 12 Q. If Rate 6 were applied to natural gas customers, how would its 700 kWh threshold 13 impact them? 14 A. The 700 kWh threshold systematically disadvantages natural gas-heated customers who 15 install heat pumps. This is a distinct problem from regressivity: the threshold is set at a level that 16 largely excludes natural gas homes from the discount. 17 Q. Why does the threshold disadvantage natural gas customers? 18 A. Because natural gas-heated homes use much less electricity before installing a heat pump than 19 delivered fuel-heated homes. The average pre-HP winter base load for natural gas homes is 441 20 kWh per month — nearly 230 kWh below the 700 kWh threshold. By contrast, delivered fuel 21 homes average 671 kWh, close to the threshold itself. The arithmetic: low-income homes capture 57% of their intended savings, so their effective bill reduction is 57% × 72% = 41%. High-income homes capture 112%, so theirs is 112% × 72% = 81%. The same ratios that produced an 8 percentage-point gap under a 14% discount produce a 40 percentage-point gap under a 72% discount. 71 75Page 78 of 107
1 This is likely by design, as the Company intends Rate 6 to only be available to delivered 2 fuel customers. As explained in Section VI, their justification for not reducing the overpayments 3 experienced by natural gas-heated customers who install heat pumps — their total energy bills 4 might go up — ignores the fact that the main reason bills go up is that these customers are being 5 overcharged. 6 I advocate for the Company’s heat pump rate to be available to all customers installing 7 heat pumps, including those who currently heat with natural gas. So let’s examine how the 8 current 700 kWh threshold would affect these customers, and whether it can be improved. 9 Figure 32 compares how Rate 6’s 700 kWh threshold classifies load for the two fuel groups side 10 by side. Figure 32: How Rate 6’s 700 kWh threshold classifies load for delivered fuel homes (left) vs. natural gas homes (right). Blue: HP load in Block 2 (discounted). Orange: HP load trapped in Block 1 (full rate). Yellow: base load getting Block 2 windfall. 11 12 The key question is: of a home’s incremental heat pump load, what share actually lands in Block 2 and receives the discount? If the threshold worked perfectly, the answer would be 76Page 79 of 107
1 100% for every home — all incremental load would be blue. For the median delivered fuel 2 home, it is 94%. In other words, the threshold largely works for over half of these customers. (It 3 does not work for everyone: roughly a third of delivered fuel homes lose a fifth or more of their 4 intended discount, and as the income analysis above established, these are disproportionately 5 lower-income homes.) 6 For the median natural gas home, however, only 55% of incremental HP load receives the 7 discount — the threshold fails. And 23% of natural gas homes — nearly 1 in 4 — would receive 8 essentially no discount at all, because their post-HP consumption never reaches 700 kWh. 9 Among delivered fuel homes, only 7% fare that poorly. 10 Q. What does this mean in practice for a natural gas customer who installs a heat pump 11 under Rate 6? 12 A. Rate 6’s Block 2 discount is designed to reduce every customer’s incremental heat pump bill 13 by 14.1%. For customers that used to heat with natural gas, the 700 kWh threshold traps so much 14 heat pump load in Block 1, that these customers would see their incremental heat pump bill 15 reduced by only 7.7%, on average — roughly half of the intended discount. The typical 16 delivered fuel home, by contrast, would see a 13.3% reduction, on average, much closer to the 17 intended 14.1% bill reduction. 18 This is the underlying reason why Rate 6 doesn’t significantly move the needle for post- 19 heat pump bill outcomes. Even with Block 2 rates set at the marginal cost floor, natural gas 20 customers receive roughly half the intended discount — and that is why more than half of them 21 would still face higher total energy bills after switching to a heat pump. 22 Q. Could the Company lower the threshold so it works better for natural gas customers? 77
Text of JPV-1.pdf
Extracted from the file · 2 pages · 2,718 characters
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Juan-Pablo Velez [26-05-10]