    1 In short: in order to achieve a block rate with per-customer thresholds that heat pump 2 customers could be auto-enrolled into, the Company would either need to commit to a software- 3 based solution, or to EnergizeCT contractors installing circuit-level energy monitors whenever 4 they install heat pumps. 5 However, a simpler alternative to per-customer thresholds exists that achieves largely the 6 same result: a seasonal rate design that lowers volumetric charges for heat pump customers in 7 winter, without relying on a block threshold at all. I present exactly such a rate in the next 8 section. 9 X. PROPOSED RATE DESIGN: RATE HP 10 Q. What do you propose to address the overcharging of heat pump customers? 11 A. I recommend that the Company create a new rate schedule, Rate HP, for residential customers 12 with heat pumps. Rather than using a block design, Rate HP would lower the volumetric rates for 13 distribution and transmission during the winter months (November through March), when the 14 incremental heat pump load occurs. Rate 1’s summer rates, generation rates, and the fixed 15 customer charge would be unchanged. All customers with heat pumps would be eligible to 16 enroll in Rate HP, regardless of whatever heating system they had before. 17 Q. How is Rate HP intended to affect revenue collection from heat pump customers? 18 A. The purpose of lowering winter rates is to bring the incremental revenue the Company 19 collects from customers installing heat pumps in line with the incremental marginal costs those 20 heat pumps actually cause (while preserving the revenue previously collected from their base 21 load). As I showed in Section III, heat pump customers are overcharged because volumetric rates 22 charge far more per incremental kWh than the incremental marginal T&D cost those kWh cause. 23 Rate HP corrects this by reducing volumetric delivery rates in winter, the season when 81
  2. Page 84 of 107

    1 incremental heat pump load is concentrated, in order to achieve bills consistent with cost- 2 causation: that is, bills that get as close possible to each customer’s pre-heat pump T&D bill, plus 3 their incremental marginal T&D cost caused by the heat pump. 4 Q. What is the ultimate objective of Rate HP? 5 A. By removing the overcharge for heat pump customers (on average), the ultimate objective of 6 Rate HP is to fix the intra-class equity and building electrification policy problems that Rate 1 7 creates (as documented in Section III and IV), and which Rate 6 fails to satisfactorily address (as 8 documented in Sections V through IX). 9 Q. What would the Company’s volumetric rates be under the proposed Rate HP? 10 A. Rate HP would reduce distribution and transmission rates during the winter months only. 11 Summer rates remain at proposed Rate 1 levels. The following table compares the Company’s 12 proposed Rate 1 rates with my proposed Rate HP rates. Table 4: Rate HP winter rates compared to Rate 1 82
  3. Page 85 of 107

    1 Generation rates, the monthly customer charge, and all distribution riders remain the 2 same as under Rate 1, as would summer distribution and transmission rates in the summer. 74 3 Q. Rate HP proposes a lower Transmission Service Rate in the winter. Can the Authority 4 set a different transmission rate for a specific rate schedule? 5 A. Yes. The Transmission Service Rate on residential bills is a retail rate set by the Authority 6 through the Company’s Transmission Adjustment Clause (“TAC”). The Company’s own tariff 7 states: “Transmission rate adjusts per the Company’s Transmission Adjustment Clause.” The 8 TAC is a state-regulated retail mechanism, not a FERC-jurisdictional wholesale rate. 75 Setting a 9 different Transmission Service Rate for Rate HP in the winter months is mechanically identical 10 to how the Authority already administers the TAC across rate schedules today. 11 Q. Does the Company already vary the Transmission Service Rate across residential rate 12 schedules? 13 A. Yes. Rate 5 (Residential Electric Heating Service) has a Transmission Service Rate of 4.901 14 ¢/kWh, while Rate 1 and Rate 6 both have a Transmission Service Rate of 5.050 ¢/kWh. The 15 Company chose not to adjust the Transmission Service Rate for Rate 6, but that was a design 16 choice — not a hard constraint. The Authority has the same power to set a seasonal Transmission Beyond the distribution energy charge and transmission, Rate 1’s volumetric delivery rate carries several passthrough riders: the Competitive Transition Assessment (CTA) and the Public Benefits charges — Systems Benefits Charge (SBC), Conservation Adjustment Mechanism (CAM), Renewable Energy, and the non-bypassable FMCC Delivery Charge. Each adjusts through its own reconciliation clause rather than this rate case; at their filed values (Exhibit CLP-RATES-3, Docket No. 26-05-10) (Eversource 2026f) they total -0.911 ¢/kWh, and I hold them unchanged under Rate HP. The total delivery rate shown in the table includes these riders. Generation reflects Eversource’s standard-service supply rates over the rate case’s test year (calendar year 2025). Because those rates vary seasonally, the single figure shown is the kWh-weighted average across the average post-heat-pump load profile, and it is identical under Rate 1 and Rate HP. 74 The Transmission Service Rate recovers the Company’s wholesale transmission costs from retail customers on a volumetric basis through the TAC. The Authority controls how those costs are allocated across rate schedules and billing periods. Redesigning the retail transmission charge for a specific schedule — e.g., lowering it in winter and raising it in summer to remain revenue-neutral — does not alter the Company’s wholesale transmission obligations or any FERC-jurisdictional rate. 75 83
  4. Page 86 of 107

    1 Service Rate for Rate HP that it used to set a different year-round Transmission Service Rate for 2 Rate 5. 3 Q. Has any other state commission directed utilities to include transmission rate reductions 4 in heat pump rates? 5 A. Yes. On June 1, 2026, the Massachusetts Department of Public Utilities (“DPU”) issued an 6 order in Docket D.P.U. 25-08-A directing National Grid and Unitil — two of the three electric 7 distribution companies in Massachusetts — to file proposals to incorporate winter transmission 8 charges into their respective heat pump rates for the 2026–2027 heating season (DPU 2026). 9 NSTAR Electric, Eversource’s Massachusetts subsidiary, was already offering a heat pump rate 10 with a winter transmission reduction, which the DPU had approved in Docket D.P.U. 25-55 in 11 2025. 76 The DPU’s June 2026 order extended the same approach to National Grid and Unitil for 12 statewide consistency. 13 Q. Why are the rate reductions concentrated in winter? 14 A. Because the incremental electricity consumption from heat pumps is concentrated in winter. 15 Heat pumps replace fossil fuel furnaces and boilers, which run primarily during the heating 16 season. In summer, heat pumps provide air conditioning — a service most homes already have to 17 some extent — so summer electricity consumption changes little after installation. 18 By concentrating the rate reduction in the months when incremental HP load occurs, Rate 19 HP avoids giving a discount to base load. This is more precisely targeted than a year-round flat 20 reduction, but it means the total annual revenue reduction needed to eliminate the overcharge is 21 achieved with a deeper winter rate reduction rather than a shallow year-round rate reduction. The DPU directed National Grid and Unitil to calculate winter transmission charges “using the same method used to derive their winter base distribution charges, including the use of the same forecasted summer and winter annual usage and seasonal adjustment factors applied to calculate the winter base distribution rates, and apply these factors to transmission charges to recover the winter transmission revenue requirement over the adjusted winter sales” (DPU 2026). 76 84
  5. Page 87 of 107

    1 Q. How did you determine the winter rate reductions for each component? 2 A. For each component — distribution and transmission — I asked: what reduction in the winter 3 volumetric rate would make the annual overpayment of the average fossil fuel-heated customer 4 who installs a heat pump equal to zero? In other words, I found the single winter ¢/kWh rate that, 5 applied to a sample of post-heat-pump load profiles, produces a population-average T&D bill 6 equal to the customer’s pre-heat-pump T&D bill plus the incremental marginal T&D cost of 7 serving the new electrified heating load. 8 Because this is a single rate applied to all customers, it zeroes out overpayment on 9 average — individual customers with different load shapes will still have residual over- or 10 underpayments. I address this issue below. 11 Q. A 71% winter reduction seems large. Why does the winter rate have to fall so steeply in 12 order to eliminate the overpayment? 13 A. When one of the Company’s fossil-heated customers installs a heat pump, they cause only 14 $10 in incremental marginal T&D cost per year, 77 on average, even though their winter 15 consumption roughly quadruples, which causes their winter T&D bill to roughly quadruple as 16 well. To satisfy cost-causation, the customer’s post-heat-pump winter T&D bill should 17 approximately equal their pre-heat-pump-winter T&D bill, plus $10. To achieve this, the winter 18 rate has to drop by roughly the same factor that winter load goes up. Four times the kWh at a 19 only slightly higher total bill means roughly one-quarter the rate per kWh — a ~75% reduction. 20 Q. You said Rate HP makes the average overpayment zero, but does not guarantee that 21 every individual customer’s overpayment is zero. How close does it get? 22 A. As close as possible without per-customer block rates. 77 A shown in Section III, Figure 10. 85
  6. Page 88 of 107

    1 Under a perfectly fair rate, each customer’s post-installation delivery bill would equal 2 their base-load bill plus only the incremental marginal T&D costs their heat pump actually 3 causes — eliminating every individual overpayment entirely. That would require implementing 4 per-customer thresholds, and charging incremental loads at marginal cost. 5 Rate HP uses a single winter rate for all customers, which is simple, practical, and 6 performs better than the Company’s one-size-fits-all block rate — though it does mean some 7 customers will still overpay, and others will underpay, even if the two wash out on average. 8 Figure 34 shows the overpayment distribution across four scenarios. Under Rate 1 (top panel), 9 virtually every heat pump customer overpays. Under Rate 6 as proposed (second panel), the 10 distribution remains wide, shifts modestly leftward, but the average overpayment remains $787 11 per year. Under the modified Rate 6 with Block 2 rates set at marginal cost (third panel), the shift 12 is larger — mean overpayment falls to $195, but delivered fuel and higher-income customers end 13 up underpaying. Under Rate HP (bottom panel), the distribution is centered on zero: the mean 14 overpayment is $-1. 86
  7. Page 89 of 107

    87
  8. Page 90 of 107

    Figure 34: Annual delivery overpayment for all fossil fuel-heated CT Eversource homes switching to heat pumps: Rate 1 vs. Rate 6 vs. Rate 6 (Block 2 at MC) vs. Rate HP. 1 Individual customers still have residual over- or underpayments — an inherent limitation 2 of any single-rate schedule. However, 61% of fossil fuel customers are within $200 of zero. 3 And unlike either Rate 6, nearly all of the systematic bias is removed: natural gas customers are 4 almost as likely to be underpaying as overpaying (53% overpay, vs. 47% of oil/propane 5 customers), and LMI customers see a similar balance (52% overpay, vs. 49% of non-LMI 6 customers). 7 In short, Rate HP does what a practical rate design can do: unlike even the version of 8 Rate 6 with discounts set to marginal cost, Rate HP eliminates the overcharge that Rate 1 9 imposes on heat pump customers on average, while leaving a over/underpayment spread that is 10 modest and that doesn’t systematically disadvantage natural gas-heated and low income 11 customers. 12 XI. IMPACT OF RATE HP ON HEAT PUMP OPERATING COSTS 13 Q. Under the proposed Rate HP, what would happen to the average natural gas-heated 14 household’s total annual energy bills when they switch to a heat pump, compared with 15 Rate 1? 16 A. After getting heat pumps, the average natural gas-heated household’s total annual energy bill 17 under Rate HP would be $865 (23%) less than if they switched to a heat pump under Rate 1. 78 Electric and natural gas consumption from NREL ResStock 2024.2 simulation (CL&P-territory natural gas-heated buildings), bills calculated using CAIRO model with proposed Rate 1 rates (bars 1–2) and proposed Rate HP rates (bar 3; see Exhibit JPV-2, Section 5). See Exhibit JPV-2, Section 1. 78 88
  9. Page 91 of 107

    Figure 35: Average annual energy bills for simulated Eversource-territory natural gas-heated homes: before heat pumps, after heat pumps under Rate 1, and after heat pumps with incremental load charged at marginal cost. 1 As Figure 35 shows, under Rate HP, the winter distribution and transmission components 2 of the post-heat-pump electricity bill would shrink compared to Rate 1, reflecting the lower, cost- 3 causation-based winter T&D rates described above. 4 And this T&D bill reduction makes a decisive difference in terms of fuel switching 5 economics: with access to fair rates, the average natural gas-heated household in the Company’s 6 territory could save $377 (12%) per year by switching their gas heating system to a heat pump, 7 instead of losing $488 per year as they do today. 8 Q. Under the proposed Rate HP, what would happen to the average delivered fuel-heated 9 household’s total annual energy bills when they switch to a heat pump, compared with 10 Rate 1? 89
  10. Page 92 of 107

    1 A. Delivered fuel-heated households who switch to a heat pump would see greater post-heat- 2 pump savings. Figure 36 shows that the average oil- or propane-heated home’s total annual 3 energy bill after switching to a heat pump under Rate HP would be $1,169 (25%) less than if 4 they switched to a heat pump under Rate 1. 79 Figure 36: Average annual energy bills for simulated Eversource-territory delivered fuelheated homes: before heat pumps, after heat pumps under Rate 1, and after heat pumps with incremental load charged at marginal cost. 5 6 Once they stop being overcharged, the average delivered fuel-heated customer could save $1,786 (34%) per year by switching from an oil or propane heating system to a heat pump. 79 Same methodology as Figure 35; delivered fuel consumption from NREL ResStock, bills calculated using CAIRO model with EIA oil/propane prices. 90