Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Files5

Search terms highlighted
Eversource rate increase is on 13 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
12 pages match
  1. Page 88 of 107

    1 Under a perfectly fair rate, each customer’s post-installation delivery bill would equal 2 their base-load bill plus only the incremental marginal T&D costs their heat pump actually 3 causes — eliminating every individual overpayment entirely. That would require implementing 4 per-customer thresholds, and charging incremental loads at marginal cost. 5 Rate HP uses a single winter rate for all customers, which is simple, practical, and 6 performs better than the Company’s one-size-fits-all block rate — though it does mean some 7 customers will still overpay, and others will underpay, even if the two wash out on average. 8 Figure 34 shows the overpayment distribution across four scenarios. Under Rate 1 (top panel), 9 virtually every heat pump customer overpays. Under Rate 6 as proposed (second panel), the 10 distribution remains wide, shifts modestly leftward, but the average overpayment remains $787 11 per year. Under the modified Rate 6 with Block 2 rates set at marginal cost (third panel), the shift 12 is larger — mean overpayment falls to $195, but delivered fuel and higher-income customers end 13 up underpaying. Under Rate HP (bottom panel), the distribution is centered on zero: the mean 14 overpayment is $-1. 86
  2. Page 89 of 107

    87
  3. Page 90 of 107

    Figure 34: Annual delivery overpayment for all fossil fuel-heated CT Eversource homes switching to heat pumps: Rate 1 vs. Rate 6 vs. Rate 6 (Block 2 at MC) vs. Rate HP. 1 Individual customers still have residual over- or underpayments — an inherent limitation 2 of any single-rate schedule. However, 61% of fossil fuel customers are within $200 of zero. 3 And unlike either Rate 6, nearly all of the systematic bias is removed: natural gas customers are 4 almost as likely to be underpaying as overpaying (53% overpay, vs. 47% of oil/propane 5 customers), and LMI customers see a similar balance (52% overpay, vs. 49% of non-LMI 6 customers). 7 In short, Rate HP does what a practical rate design can do: unlike even the version of 8 Rate 6 with discounts set to marginal cost, Rate HP eliminates the overcharge that Rate 1 9 imposes on heat pump customers on average, while leaving a over/underpayment spread that is 10 modest and that doesn’t systematically disadvantage natural gas-heated and low income 11 customers. 12 XI. IMPACT OF RATE HP ON HEAT PUMP OPERATING COSTS 13 Q. Under the proposed Rate HP, what would happen to the average natural gas-heated 14 household’s total annual energy bills when they switch to a heat pump, compared with 15 Rate 1? 16 A. After getting heat pumps, the average natural gas-heated household’s total annual energy bill 17 under Rate HP would be $865 (23%) less than if they switched to a heat pump under Rate 1. 78 Electric and natural gas consumption from NREL ResStock 2024.2 simulation (CL&P-territory natural gas-heated buildings), bills calculated using CAIRO model with proposed Rate 1 rates (bars 1–2) and proposed Rate HP rates (bar 3; see Exhibit JPV-2, Section 5). See Exhibit JPV-2, Section 1. 78 88
  4. Page 91 of 107

    Figure 35: Average annual energy bills for simulated Eversource-territory natural gas-heated homes: before heat pumps, after heat pumps under Rate 1, and after heat pumps with incremental load charged at marginal cost. 1 As Figure 35 shows, under Rate HP, the winter distribution and transmission components 2 of the post-heat-pump electricity bill would shrink compared to Rate 1, reflecting the lower, cost- 3 causation-based winter T&D rates described above. 4 And this T&D bill reduction makes a decisive difference in terms of fuel switching 5 economics: with access to fair rates, the average natural gas-heated household in the Company’s 6 territory could save $377 (12%) per year by switching their gas heating system to a heat pump, 7 instead of losing $488 per year as they do today. 8 Q. Under the proposed Rate HP, what would happen to the average delivered fuel-heated 9 household’s total annual energy bills when they switch to a heat pump, compared with 10 Rate 1? 89
  5. Page 92 of 107

    1 A. Delivered fuel-heated households who switch to a heat pump would see greater post-heat- 2 pump savings. Figure 36 shows that the average oil- or propane-heated home’s total annual 3 energy bill after switching to a heat pump under Rate HP would be $1,169 (25%) less than if 4 they switched to a heat pump under Rate 1. 79 Figure 36: Average annual energy bills for simulated Eversource-territory delivered fuelheated homes: before heat pumps, after heat pumps under Rate 1, and after heat pumps with incremental load charged at marginal cost. 5 6 Once they stop being overcharged, the average delivered fuel-heated customer could save $1,786 (34%) per year by switching from an oil or propane heating system to a heat pump. 79 Same methodology as Figure 35; delivered fuel consumption from NREL ResStock, bills calculated using CAIRO model with EIA oil/propane prices. 90
  6. Page 93 of 107Match

    1 Q. Under the proposed Rate HP, how would post-heat-pump bill impacts vary across the 2 full population of the Company’s residential customers that currently heat with natural 3 gas? 4 A. Figure 37 compares the bill outcomes for natural gas-heated homes switching to a heat pump 5 under Rate 1 versus Rate HP. 80 Figure 37: Change in total annual energy bill for natural gas-heated CT Eversource homes switching to a heat pump, under Rate 1 vs. Rate HP. 6 Under current Rate 1, only 13% of natural gas-heated households could lower their total 7 annual energy bills by switching to a heat pump. 8 Under Rate HP, 83% would save by switching, and those that still see a bill increase would lose 9 only $144 on average. 10 In other words, allowing heat pump customers to stop overpaying would transform the 11 economics of electrification for the 34% of the Company’s customers that heat with natural gas. 12 Under Rate 1, installing a heat pump is a losing proposition: most natural gas-heated households NREL ResStock 2024.2 and CAIRO rate simulation, using the Company’s proposed Rate 1 and proposed Rate HP rates. Gas tariffs: the filed residential gas rates of the gas utility serving each home (CT Natural Gas, Southern CT Gas, Yankee Gas, or Norwich Public Utilities). See Exhibit JPV-2, Section 5 for rate derivation. 80 91
  7. Page 94 of 107

    1 would pay more. Under Rate HP, 83% would save — and the median saver would cut $275 per 2 year from their energy bills. 3 Q. Under the proposed Rate HP, how would post-heat-pump bill impacts vary across the 4 full population of the Company’s residential customers that currently heat with delivered 5 fuels? 6 A. Figure 38 shows the same comparison for delivered fuel-heated homes. 81 Figure 38: Change in total annual energy bill for delivered fuel-heated CT Eversource homes switching to a heat pump, under Rate 1 vs. Rate HP. 7 Delivered fuel households already benefit significantly from switching even under 8 current rates: 90% would save, with median annual savings of $512. Under Rate HP, 99% would 9 save — and their average savings grow by an additional $1,169 per year. For households heating 10 with oil or propane, a heat pump under Rate HP is not just a climate measure; it is the single 11 largest thing they could do to cut their energy bills. 12 XII. ENROLLMENT: HOW CUSTOMERS GET ON TO RATE HP 13 Q. How would customers be enrolled in the proposed Rate HP? 14 A. I recommend two enrollment channels, both automatic. 81 Same methodology as Figure 37; delivered fuel bills use EIA residential heating oil and propane prices. 92
  8. Page 95 of 107

    Every new customer that installs a heat pump should be auto-enrolled in Rate HP at 1 2 the time of installation. To achieve this, every customer receiving a heat pump incentive through 3 Energize CT or the New England Heat Pump Accelerator should be placed on Rate HP 4 automatically. For installations that happen outside of Energize CT — for example, self-funded 5 purchases — the Company should provide an attestation and certification pathway: a simple 6 form the installer or customer submits to confirm a qualifying heat pump was installed. For existing heat pump customers, the Company should auto-enroll all known electric 7 8 customers who have previously installed heat pumps. These customers are being overcharged 9 right now. Since the day they installed their heat pump, they have been paying far more than the 10 T&D costs caused by their new load. And a portion of these customers are readily identifiable by 11 the Company, those that previously received a heat pump incentive through EnergizeCT or any 12 other relevant state or utility program. There is no reason to delay correcting this. 13 After a customer is auto-enrolled, Rate HP would be opt-out: the customer could return to Rate 1 14 (or any other optional rate) if they choose. 15 Q. Why do you recommend automatic enrollment rather than an opt-in rate? 16 A. Because opt-in rates fail. They require customers to know the rate exists, understand that it 17 would save them money, and take affirmative action to enroll. Most customers never do. 18 This is not a theoretical concern. Maine’s Central Maine Power offered a seasonal heat pump 19 rate on an opt-in basis. Enrollment never exceeded 2% of eligible customers. 82 20 York’s experience is even more striking. Con Edison has facilitated more than 43,000 21 heat pump installations through its Clean Heat program, yet as of December 2025, only about Shah, Wagner & Teener, “Designing Better Rates for Heat Pump Customers,” RMI (June 17, 2026) (Shah, Wagner, and Teener 2026). CMP’s seasonal heat pump rate launched January 2023 with a 5,000 customer enrollment cap. Maine had approximately 143,000 heat pumps installed statewide by the end of 2024. Even with active marketing, only about 2,100 enrolled. 82 93
  9. Page 96 of 107

    1 500 households — barely 1% — had enrolled in the utility’s opt-in Steady Use Rate, which is 2 designed to save a typical heat pump customer roughly $500 per year. 83 That is $131 million in 3 cumulative bill savings left on the table over the rate period, simply because customers did not 4 know the rate existed or found the enrollment process confusing. 5 The goal of offering heat pump rates by creating Rate HP is to eliminate the existing 6 cross-subsidy between heat pump customers and fossil-heating customers, and to prevent 7 customers newly installing heat pumps from overpaying in the first place. But creating a new 8 rate schedule does not automatically solve the problem — the rate needs to be adopted at 9 scale. And if a heat pump rate isn’t paired with auto-enrollment, it won’t be. 10 Massachusetts avoided the opt-in trap entirely by building auto-enrollment into its heat 11 pump rate from the start. In DPU 25-08, the Massachusetts Department of Public Utilities 12 approved a lower heat pump rate for the state’s three investor-owned electric utilities — 13 Eversource, Unitil, and National Grid. 84 Customers who install heat pumps through Mass Save 14 — the state’s ratepayer-funded efficiency program — are automatically enrolled at the time of 15 installation. For customers who installed heat pumps before the program existed, Massachusetts 16 uses an attestation process. 17 We know that opt-in rates get low enrollment; the Company can and must design a better 18 enrollment mechanism: automatic enrollment through Energize CT and the New England Heat 19 Pump Accelerator. Every heat pump customer who is not enrolled continues to be overcharged 20 by the full amount every year. 83 Environmental Defense Fund, Rewiring America & Alliance for a Green Economy, “Con Edison Heat Pump Customers Missing Out on $131 Million in Bill Savings” (July 9, 2025) (Environmental Defense Fund, Rewiring America, and Alliance for a Green Economy 2025). Enrollment figure of ~500 as of December 2025 reported in Mona Zhang, “How NY heat pump users got stuck with higher bills,” E&E News (March 3, 2026) (Zhang 2026). 84 The Massachusetts DPU maintains an overview of the seasonal heat pump rates and enrollment procedures for all three IOUs at DPU (2025). 94
  10. Page 97 of 107

    1 Q. Could automatic enrollment cause some heat pump customers to see higher bills? 2 A. No, because Rate HP is specifically designed so that every heat pump customer pays less than 3 they would under Rate 1. By lowering Rate 1’s existing winter rates, no heat pump customer 4 would be made worse off by being placed on Rate HP. 5 This is the key link between rate design and enrollment. A rate that only lowers charges 6 can be safely applied to all heat pump customers without risk of adverse bill impacts. If the rate 7 raised some charges and lowered others — for example, a higher fixed charge paired with a 8 lower volumetric rate — some customers could see higher bills in certain months. The seasonal 9 winter reduction avoids this entirely: summer rates are unchanged, and winter rates are only 10 lower. There are no structural losers. 11 A rate design that only lowers charges unlocks auto-enrollment, but it necessarily 12 constrains eligibility: it must be a tech-specific rate, rather than one available to all residential 13 customers. A lower rate is justified for heat pump customers. As covered in section III, they are 14 structural “high-usage” customers who would otherwise overpay. A lower rate available to all 15 customers would simply lower the bills of anyone who enrolled, which would create a revenue 16 shortfall under heavy enrollment. 17 I believe this is the right trade-off. A rate that can be safely auto-enrolled to every eligible 18 customer, even if restricted to a defined population, will reach far more people and thus have a 19 fundamentally bigger impact than an optional rate with a revenue-neutral design (like a high 20 fixed charge) that is available to all customers but which will achieve negligible enrollment, 21 because it requires customers to discover it, evaluate it, and opt in. 22 Q. Why is it important to auto-enroll existing heat pump customers, not just new ones? 95

Text of JPV-1.pdf