Prefiled testimony
Witness: Melissa Whited
Files3
Synapse - Eversource COS and Rate Design Testimony Final.pdf
PDF · 829 KB · 48 pagesText searchable
Download Synapse - Eversource COS and Rate Design Testimony Final.pdfRead the text of Synapse - Eversource COS and Rate Design Testimony Final.pdf
MW-2- Synapse Attachment.pdf
PDF · 4.6 MB · 276 pagesText searchable
Download MW-2- Synapse Attachment.pdfRead the text of MW-2- Synapse Attachment.pdf
MW-1 - Synapse Attachment.pdf
PDF · 734 KB · 13 pagesText searchable
Download MW-1 - Synapse Attachment.pdfRead the text of MW-1 - Synapse Attachment.pdf
Page 17 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 correlation between the area (or mileage) of a distribution system and the number of 2 customers is “very weak,” because “it makes no allowance for the density factor 3 (customers per linear mile or per square mile),” and that “an increase in number of 4 customers does not necessarily betoken any increase whatever in the costs of a minimum- 5 sized distribution system.”24 6 In other words, using customer counts as the allocator for the minimum system 7 does not capture the higher cost of serving sprawling or remote populations relative to 8 dense urban centers. For example, if the Company adds a new residential customer with a 9 negligible level of demand in a populated area, the additional distribution costs to serve 10 that customer—aside from dedicated customer infrastructure—would generally also be 11 negligible, because the system has already been constructed to serve customers in that 12 area. In contrast, a new customer located in a rural area may require investments in 13 additional distribution system poles and wires to extend service to the customer’s 14 residence. These hypotheticals illustrate that distribution system costs associated with 15 connecting a new customer to the grid tend to vary more with geographic density than the 16 number of customers. 17 Q 18 19 How did Professor Bonbright recommend minimum distribution system costs be classified? A 20 Professor Bonbright argued that the costs of the minimum system should be excluded from demand-related costs, but also that classifying them as customer-related is “clearly 24 Id., at 348. 15Page 18 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 indefensible.”25 Instead, in Bonbright’s opinion, these costs “should be recognized as a 2 strictly unallocable portion of total costs.”26 3 Q 4 5 Are there any alternative methods that would better account for customer density in cost of service models? A Yes. The Ontario Energy Board approved the use of a density factor, calculated as 6 customers per kilometer of line,27 to inform categorization of customer-related and 7 demand-related costs. The Ontario Energy Board’s examination identified low, medium, 8 and high customer density “bins” to establish the percentage of customer-related costs. 9 Transformers were part of the cost pool subjected to the minimum plant categorization 10 based on customer density.28 This method could also be applied to Eversource’s system 11 in the future. 12 Q Do you have any other concerns regarding the minimum system method? 13 A Yes. The minimum system includes poles, conductors, and transformers that are capable 14 of serving some amount of demand. In some cases, the “minimum system” as defined by 15 the utility may even be capable of serving most or all of a typical residential customer’s 16 peak demand. This infrastructure is classified as customer-related, while the remaining 17 demand-related costs are allocated using each class’s full non-coincident peak demand, 18 including the portion the minimum system already serves. Unless each class’s demand 19 allocator is reduced to account for the load-carrying capability of the minimum system, 20 classes with many small customers will be charged twice for the same capacity: once 21 through the customer classification and again through the demand allocator. The 25 Ibid. Ibid. 27 Ontario Energy Board, EB-2007-0667, Board Staff Discussion Paper, p. 12. 28 Ibid. 26 16Page 19 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 residential class bears most of this double counting, because it has the most customers 2 and the lowest demand per customer. 3 This issue was identified by the Staff of the Ontario Energy Board, who wrote 4 that “[a] Minimum System has a certain load carrying capability which can be viewed as 5 being demand-related. As a result, the customer-related costs will have a demand 6 component in them. If no adjustment is made, some customers (e.g., small users) may be 7 allocated a disproportionate share of demand-related costs. If the Minimum System 8 Method is preferred for categorization, Staff would recommend that distributors be 9 required to also adjust for the [Peak Load Carrying Capacity] of the assumed Minimum 10 System.”29 11 Q 12 13 Has the Authority previously approved a load carrying adjustment for the minimum system? A Yes. In Docket No. 24-10-04, the Authority determined that “it is appropriate to use the 14 Company’s load-carrying capacity adjustment values for poles and conductors,” as well 15 as conductors and line transformers.30 16 Q Did Eversource implement such an adjustment? 17 A No. When asked whether the Company “considered the minimum system’s load carrying 18 capacity when allocating demand-related costs,” the Company responded that it did not 19 “revise the demand classification percentage based on the minimum system carrying 29 Ontario Energy Board. Cost Allocation Review: Staff Discussion Paper. September 2005. At 21-22. Available at https://www.oeb.ca/documents/cases/EB-2005-0317/staffdiscussionpaper_160905.pdf. 30 Final Order in Docket 24-10-04, October 28, 2025, pp. 198-199. 17Page 20 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 capacity,” and that the ACOS study relied on the “traditionally applied MDS approach as 2 applied in prior rate cases and as per the NARUC Manual.”31 3 Q 4 5 Do you agree that the Company applied the minimum system method in a manner consistent with the NARUC manual? A No. The NARUC Manual states that “[w]hen using this distribution method, the analyst 6 must be aware that the minimum-size distribution equipment has a certain load-carrying 7 capability, which can be viewed as a demand-related cost.”32 8 Q What are your recommendations for the minimum system method? 9 A I recommend that the Authority reject the minimum system method. Instead, my primary 10 recommendation for this proceeding is that the Authority adopt the basic customer 11 method, under which the costs that are directly classified as being customer-related are 12 the costs of metering (including the service drop), meter reading, and billing. In some 13 cases, the cost of the secondary line transformer is also included. This method limits 14 customer-related costs to those clearly related to the cost associated with serving a new 15 customer. All other costs should be classified as demand-related until the Company 16 completes a study that appropriately allocates “minimum system” costs according to 17 customer density. To accomplish this, I recommend that the Authority direct Eversource 18 to develop a geographic dispersion allocator, similar to that approved for Ontario’s 19 Minimum System Studies, where the Company applies density bins (e.g., urban, rural, 20 and mixed) measured in customers per mile to differentiate customer-related cost 21 percentages. 31 32 OCC-738(a). NARUC (1992) Electric Cost Allocation Manual, at 95. 18Page 21 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 If the Authority chooses to approve the use of the minimum system method for 2 this case or future cases, it should require the Company to adjust each class’s non- 3 coincident peak demand by the minimum system’s load carrying capacity per customer. 4 Failure to do so would result in double counting because the minimum system already 5 serves a large portion of the residential class’s demand, and a portion of other classes’ 6 demands. The demand served by the minimum system should not be used again to 7 allocate costs to customers through the use of unadjusted NCP allocators. 8 Q 9 10 What is the impact of using the basic customer method in which FERC Accounts 364-368 are classified as 100 percent demand-related? A The Company indicates that the basic customer method would result in an increase in the 11 rate of return under current rates of 0.85 percent for Schedules 1 and 7, as well as an 12 increase in the rate of return for the unmetered and street lighting classes. Other classes 13 would see a reduction in their rate of return. These impacts are shown in the table below. 19Page 22 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 Table 3. Impact of adopting the basic customer method Rate Codes Minimum Dist. System Basic Customer Method Current Rates Rate of Class to Return Total Current Rates Rate of Class to Return Total Change Rate 1 & 7 0.4% 0.3 1.2% 1.1 0.85% Rate 5 -0.2% -0.2 -0.3% -0.3 -0.05% Rate 18 -12.1% -11.5 -12.4% -11.8 -0.26% Rate 27, 27A, 30, 30A & EV-S 5.0% 4.8 3.8% 3.6 -1.20% Rate 29 -4.9% -4.6 -5.6% -5.3 -0.71% Rate 35, 37 & EV-M 2.9% 2.7 0.9% 0.8 -1.95% Rate 39 -3.5% -3.3 -4.4% -4.2 -0.95% Rate 40 5.2% 5.0 3.7% 3.5 -1.53% Rate 41 4.2% 4.0 1.9% 1.8 -2.26% Rate 55 0.4% 0.4 -1.2% -1.1 -1.59% Rate 56 & EV-L 1.7% 1.7 -0.1% -0.1 -1.84% Rate 57 -0.8% -0.8 -2.2% -2.1 -1.37% Rate 58 0.5% 0.5 -1.1% -1.0 -1.64% Rate 115 -0.7% -0.7 0.4% 0.4 1.12% Rate 116 & 117 -5.8% -5.5 -5.6% -5.3 0.16% Rate 119 162.3% 154.2 145.0% 137.8 -17.32% Total 1.05% 1.0 1.05% 1.0 2 3 C. The Company’s allocation method for distribution plant costs is outdated 4 Q How does the Company allocate demand-related distribution costs? 5 A The Company allocates demand-related distribution costs using the relative class noncoincident peaks.33 6 7 Q 8 9 Is it considered best practice to use traditional NCP allocators for distribution plant in today’s landscape of cost of service methods? A 10 No. The Company asserts that it relies on “best ACOS practice methods”34 but traditional NCP allocators fail to account for variations in when class peaks occur and when 33 34 Exh. CLP-ACOS-1, at 6:4-7. Exh. CLP-ACOS-1, at 1:9-11. 20Page 23 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 individual feeder and substation peaks occur. A more granular approach is needed, which 2 adoption of AMI will facilitate. 3 Q How can AMI data better align cost allocation with cost causation? 4 A Understanding localized cost causation addresses the variance in customer class 5 compositions at different feeders. One circuit may be utilized mostly by the residential 6 class, while another on the same substation is used predominantly by the industrial class. 7 AMI interval data can map directly onto specific substations and feeders, allowing the 8 Company to calculate the exact coincidence factor of each customer class at that specific 9 grid asset. That way, the classes driving local capacity investments bear the appropriate 10 share of each asset’s cost. 11 Q 12 13 What do you recommend regarding updates to distribution allocation practices in the Company’s cost of service studies? A I recommend the Authority direct Eversource to develop more sophisticated allocation 14 practices by using AMI data to measure class contributions to individual distribution 15 feeder and substation peak loads. By shifting from average-coincident assumptions to 16 localized data, the Company can better assign costs in line with causal contribution. AMI 17 data can also delineate minimum system requirements from peak capacity requirements, 18 so that the Company can classify infrastructure costs into customer-, energy- and 19 demand-related components accordingly. 20 Specifically, I recommend that the Authority direct the Company to design its 21 AMI data systems so that, by its next rate case, it can allocate distribution plant more 22 accurately. Specifically, substations (FERC Account 362) would be allocated based on 23 class contribution to substation peaks; primary lines (Accounts 364-367) would be 21Page 24 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 allocated based on class contribution to feeder peaks; and line transformers (Account 2 368) would be allocated on class contribution to transformer peaks. Each allocator would 3 be weighted by the installed cost of the equipment involved. This ties cost responsibility 4 to the loads that drive equipment sizing decisions, rather than to a class-wide statistic that 5 may never coincide with any local distribution system constraint. 6 Thus, I recommend that the Authority direct the Company to (1) retain hourly 7 interval data from AMI meters in a form suitable for equipment-level aggregation, and 8 (2) in its next base rate case, file an equipment-level allocation study alongside its 9 conventional class cost of service study, so the Authority can compare the results before 10 adopting a new method. 11 V. RESIDENTIAL HEAT PUMP RATE (RATE 6) PROPOSAL 12 Q Please summarize the Company’s proposal for Rate 6. 13 A Rate 6 is a whole-house rate that would provide a discounted rate for incremental winter 14 load associated with new air source heat pumps. According to the Company, the purpose 15 of the proposed rate is to drive heat pump adoption, which would improve system 16 utilization in winter months,35 and to support affordability for customers who currently 17 heat with delivered fuels.36 18 Table 4 compares the proposed Rate 6 to the standard residential Rate 1 as each 19 has been proposed by the Company in this proceeding. 35 36 Exh. CLP-RATES-1, at 34. Response to CLF-003a. 22Page 25 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 Table 4. Comparison of Eversource proposed Rate 1 and Rate 6 Charges Distribution Rate Component Customer Charge ($/month) Rate 1 (Standard) Rate 6 (Heat Pump) Energy Charge ($/kWh) Block 1 - All non-winter usage and winter usage ≤ 700 kWh Block 2 - Winter usage > 700 kWh $12.36 $30.95 $0.12196 $0.09431 $0.12196 $0.07517 2 3 Q Do you support offering lower winter rates to heat pump load? 4 A Yes. The Company’s system is summer-peaking, meaning that system costs are primarily 5 driven by summer peak demand, while incremental winter load does not contribute as 6 much to the need for new distribution infrastructure. Heat pump load, which is 7 concentrated in winter months, can help improve system efficiency by spreading the 8 fixed costs of the system across greater volumes of sales, thereby putting downward 9 pressure on rates for all customers. Lower rates during winter months can help 10 incentivize heat pump adoption and accelerate the addition of heat pump load. 11 Q Do you have any concerns with the design of the Company’s proposed Rate 6? 12 A Yes. I have two main concerns with the design of Rate 6 as proposed. First, the rate is not 13 revenue neutral and will result in cost shifts to other customers. Second, the proposed 14 eligibility requirements will undermine the objectives of the rate. 15 A. Eversource’s proposed Rate 6 will result in cost shifting 16 Q Please describe the three distribution rate components of Rate 6. 17 A Rate 6 has three distribution rate components: a fixed monthly customer charge; a Block 18 1 volumetric energy charge, which applies to all non-winter usage and to the first 700 19 kWh of usage per month in the winter; and a new Winter Block 2 volumetric energy 23Page 26 of 48
Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 charge, which is the discounted rate applied to usage above 700 kWh/month during the 2 November through March heating season.37 3 The customer charge is designed to recover the Company’s estimated marginal 4 customer costs and is set at $30.95 per month. This high customer charge lowers the 5 amount of costs recovered through volumetric charges,38 resulting in the Rate 6 Block 1 6 charge ($0.09431/kWh) being approximately 23 percent lower than the Rate 1 energy 7 charge ($0.12196/kWh). The Company explains that the higher customer charge is meant 8 to recover the share of the class revenue requirement associated with load that existed 9 prior to any incremental heat pump load, so that the resulting volumetric rate provides a 10 basis for designing rates for the incremental heat pump load.39 11 Q 12 13 How did the Company determine the appropriate threshold for discounted Block 2 charges? A The 700 kWh threshold for the Winter Block 2 charge is based on the average annual 14 usage of the median Rate 1 customer.40 The Company states that it did not design the 15 Block 2 price as a discount from the Block 1 rate; instead, the Company built the price up 16 from marginal costs: it added the marginal cost of serving load (a subtotal of marginal 17 facilities cost plus marginal energy cost, totaling $0.04152/kWh) to a “reduced 18 reconciliation adjustment” of $0.03365/kWh to arrive at a Winter Block 2 rate of 19 $0.07517/kWh.41 Specifically, the reconciliation adjustment is scaled down by a “System 37 Exh. CLP-RATES-1, at 31. Exh. CLP-RATES-6. 39 Response to OCC-477. 40 Exhibit CLP-RATES-1, at 34, lines 5-7. 41 Exhibit CLP-RATES-6. 38 24
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Melissa Whited [26-05-10]