    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 If the Authority chooses to approve the use of the minimum system method for 2 this case or future cases, it should require the Company to adjust each class’s non- 3 coincident peak demand by the minimum system’s load carrying capacity per customer. 4 Failure to do so would result in double counting because the minimum system already 5 serves a large portion of the residential class’s demand, and a portion of other classes’ 6 demands. The demand served by the minimum system should not be used again to 7 allocate costs to customers through the use of unadjusted NCP allocators. 8 Q 9 10 What is the impact of using the basic customer method in which FERC Accounts 364-368 are classified as 100 percent demand-related? A The Company indicates that the basic customer method would result in an increase in the 11 rate of return under current rates of 0.85 percent for Schedules 1 and 7, as well as an 12 increase in the rate of return for the unmetered and street lighting classes. Other classes 13 would see a reduction in their rate of return. These impacts are shown in the table below. 19
  2. Page 22 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 Table 3. Impact of adopting the basic customer method Rate Codes Minimum Dist. System Basic Customer Method Current Rates Rate of Class to Return Total Current Rates Rate of Class to Return Total Change Rate 1 & 7 0.4% 0.3 1.2% 1.1 0.85% Rate 5 -0.2% -0.2 -0.3% -0.3 -0.05% Rate 18 -12.1% -11.5 -12.4% -11.8 -0.26% Rate 27, 27A, 30, 30A & EV-S 5.0% 4.8 3.8% 3.6 -1.20% Rate 29 -4.9% -4.6 -5.6% -5.3 -0.71% Rate 35, 37 & EV-M 2.9% 2.7 0.9% 0.8 -1.95% Rate 39 -3.5% -3.3 -4.4% -4.2 -0.95% Rate 40 5.2% 5.0 3.7% 3.5 -1.53% Rate 41 4.2% 4.0 1.9% 1.8 -2.26% Rate 55 0.4% 0.4 -1.2% -1.1 -1.59% Rate 56 & EV-L 1.7% 1.7 -0.1% -0.1 -1.84% Rate 57 -0.8% -0.8 -2.2% -2.1 -1.37% Rate 58 0.5% 0.5 -1.1% -1.0 -1.64% Rate 115 -0.7% -0.7 0.4% 0.4 1.12% Rate 116 & 117 -5.8% -5.5 -5.6% -5.3 0.16% Rate 119 162.3% 154.2 145.0% 137.8 -17.32% Total 1.05% 1.0 1.05% 1.0 2 3 C. The Company’s allocation method for distribution plant costs is outdated 4 Q How does the Company allocate demand-related distribution costs? 5 A The Company allocates demand-related distribution costs using the relative class noncoincident peaks.33 6 7 Q 8 9 Is it considered best practice to use traditional NCP allocators for distribution plant in today’s landscape of cost of service methods? A 10 No. The Company asserts that it relies on “best ACOS practice methods”34 but traditional NCP allocators fail to account for variations in when class peaks occur and when 33 34 Exh. CLP-ACOS-1, at 6:4-7. Exh. CLP-ACOS-1, at 1:9-11. 20
  3. Page 23 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 individual feeder and substation peaks occur. A more granular approach is needed, which 2 adoption of AMI will facilitate. 3 Q How can AMI data better align cost allocation with cost causation? 4 A Understanding localized cost causation addresses the variance in customer class 5 compositions at different feeders. One circuit may be utilized mostly by the residential 6 class, while another on the same substation is used predominantly by the industrial class. 7 AMI interval data can map directly onto specific substations and feeders, allowing the 8 Company to calculate the exact coincidence factor of each customer class at that specific 9 grid asset. That way, the classes driving local capacity investments bear the appropriate 10 share of each asset’s cost. 11 Q 12 13 What do you recommend regarding updates to distribution allocation practices in the Company’s cost of service studies? A I recommend the Authority direct Eversource to develop more sophisticated allocation 14 practices by using AMI data to measure class contributions to individual distribution 15 feeder and substation peak loads. By shifting from average-coincident assumptions to 16 localized data, the Company can better assign costs in line with causal contribution. AMI 17 data can also delineate minimum system requirements from peak capacity requirements, 18 so that the Company can classify infrastructure costs into customer-, energy- and 19 demand-related components accordingly. 20 Specifically, I recommend that the Authority direct the Company to design its 21 AMI data systems so that, by its next rate case, it can allocate distribution plant more 22 accurately. Specifically, substations (FERC Account 362) would be allocated based on 23 class contribution to substation peaks; primary lines (Accounts 364-367) would be 21
  4. Page 24 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 allocated based on class contribution to feeder peaks; and line transformers (Account 2 368) would be allocated on class contribution to transformer peaks. Each allocator would 3 be weighted by the installed cost of the equipment involved. This ties cost responsibility 4 to the loads that drive equipment sizing decisions, rather than to a class-wide statistic that 5 may never coincide with any local distribution system constraint. 6 Thus, I recommend that the Authority direct the Company to (1) retain hourly 7 interval data from AMI meters in a form suitable for equipment-level aggregation, and 8 (2) in its next base rate case, file an equipment-level allocation study alongside its 9 conventional class cost of service study, so the Authority can compare the results before 10 adopting a new method. 11 V. RESIDENTIAL HEAT PUMP RATE (RATE 6) PROPOSAL 12 Q Please summarize the Company’s proposal for Rate 6. 13 A Rate 6 is a whole-house rate that would provide a discounted rate for incremental winter 14 load associated with new air source heat pumps. According to the Company, the purpose 15 of the proposed rate is to drive heat pump adoption, which would improve system 16 utilization in winter months,35 and to support affordability for customers who currently 17 heat with delivered fuels.36 18 Table 4 compares the proposed Rate 6 to the standard residential Rate 1 as each 19 has been proposed by the Company in this proceeding. 35 36 Exh. CLP-RATES-1, at 34. Response to CLF-003a. 22
  5. Page 25 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 Table 4. Comparison of Eversource proposed Rate 1 and Rate 6 Charges Distribution Rate Component Customer Charge ($/month) Rate 1 (Standard) Rate 6 (Heat Pump) Energy Charge ($/kWh) Block 1 - All non-winter usage and winter usage ≤ 700 kWh Block 2 - Winter usage > 700 kWh $12.36 $30.95 $0.12196 $0.09431 $0.12196 $0.07517 2 3 Q Do you support offering lower winter rates to heat pump load? 4 A Yes. The Company’s system is summer-peaking, meaning that system costs are primarily 5 driven by summer peak demand, while incremental winter load does not contribute as 6 much to the need for new distribution infrastructure. Heat pump load, which is 7 concentrated in winter months, can help improve system efficiency by spreading the 8 fixed costs of the system across greater volumes of sales, thereby putting downward 9 pressure on rates for all customers. Lower rates during winter months can help 10 incentivize heat pump adoption and accelerate the addition of heat pump load. 11 Q Do you have any concerns with the design of the Company’s proposed Rate 6? 12 A Yes. I have two main concerns with the design of Rate 6 as proposed. First, the rate is not 13 revenue neutral and will result in cost shifts to other customers. Second, the proposed 14 eligibility requirements will undermine the objectives of the rate. 15 A. Eversource’s proposed Rate 6 will result in cost shifting 16 Q Please describe the three distribution rate components of Rate 6. 17 A Rate 6 has three distribution rate components: a fixed monthly customer charge; a Block 18 1 volumetric energy charge, which applies to all non-winter usage and to the first 700 19 kWh of usage per month in the winter; and a new Winter Block 2 volumetric energy 23
  6. Page 26 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 charge, which is the discounted rate applied to usage above 700 kWh/month during the 2 November through March heating season.37 3 The customer charge is designed to recover the Company’s estimated marginal 4 customer costs and is set at $30.95 per month. This high customer charge lowers the 5 amount of costs recovered through volumetric charges,38 resulting in the Rate 6 Block 1 6 charge ($0.09431/kWh) being approximately 23 percent lower than the Rate 1 energy 7 charge ($0.12196/kWh). The Company explains that the higher customer charge is meant 8 to recover the share of the class revenue requirement associated with load that existed 9 prior to any incremental heat pump load, so that the resulting volumetric rate provides a 10 basis for designing rates for the incremental heat pump load.39 11 Q 12 13 How did the Company determine the appropriate threshold for discounted Block 2 charges? A The 700 kWh threshold for the Winter Block 2 charge is based on the average annual 14 usage of the median Rate 1 customer.40 The Company states that it did not design the 15 Block 2 price as a discount from the Block 1 rate; instead, the Company built the price up 16 from marginal costs: it added the marginal cost of serving load (a subtotal of marginal 17 facilities cost plus marginal energy cost, totaling $0.04152/kWh) to a “reduced 18 reconciliation adjustment” of $0.03365/kWh to arrive at a Winter Block 2 rate of 19 $0.07517/kWh.41 Specifically, the reconciliation adjustment is scaled down by a “System 37 Exh. CLP-RATES-1, at 31. Exh. CLP-RATES-6. 39 Response to OCC-477. 40 Exhibit CLP-RATES-1, at 34, lines 5-7. 41 Exhibit CLP-RATES-6. 38 24
  7. Page 27 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 Peak Coincidence Factor” of 63.7%, which is the ratio of the coincidence factor with 2 space heating (25.6%) and the coincidence factor without space heating (40.1%).42 3 Q Is the proposed Rate 6 revenue neutral and cost-reflective? 4 A The Company’s proposed Rate 6 is not revenue neutral with Rate 1. Under the 5 Company’s rate design approach, Rate 6’s increased monthly customer charge enables a 6 lower Block 1 rate.43 However, the Block 2 discount is not counterbalanced with 7 increases in other rate components. While the lower Block 2 rate may reflect the lower 8 marginal cost of winter usage, the summer rates are not adjusted upwards to similarly 9 reflect the higher marginal cost of summer usage. This approach results in a rate that is 10 not revenue neutral. Additionally, the revenue impact of the Block 2 rate also depends on 11 whether the Company’s assumptions about the load billed at the Block 2 rate prove 12 correct. The design of the discount assumes that space heating has a low system peak 13 coincidence factor of 25.6%.44 However, this metric is based on load research on 14 customers under Rate 5, which is a legacy rate more likely to reflect resistance heating 15 load than heat pump load. Heat pumps have different load characteristics than resistance 16 heating. A different system peak coincidence factor could undermine the cost reflectivity 17 of Rate 6. 18 Q Why is it important for Rate 6 to be revenue neutral? 19 A In theory, as long as a rate is set to recover at least the marginal cost associated with new 20 load, additional load on the system will not result in higher costs for existing load. 21 However, Rate 6 has not been designed in a way that reliably distinguishes new heat 42 Exhibit CLP-RATES-6. Figures as listed are rounded and derived from the Company’s MCOS study. Exh. CLP-RATES-6. 44 Exh. CLP-RATES-6. 43 25
  8. Page 28 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 pump load from existing load on the system. Instead, under Eversource’s proposal, all 2 winter-month consumption above 700 kWh would be billed only at the discounted Winter 3 Block 2 rate, regardless of whether that consumption comes from a heat pump. 4 Despite claiming that the average usage for customers without heat pumps is 5 approximately 700 kWh, the Company explains that it cannot differentiate which 6 customers have or do not have heat pumps or isolate heat pump load from a customer’s 7 other usage.45 This means that the 700 kWh threshold is not based on any analysis of 8 customer load with or without heat pumps, and the Company has not provided sufficient 9 evidence that the 700 kWh threshold is a reasonable demarcation between heat pump and 10 non-heat pump load. As a result, any Rate 6 customer whose winter usage exceeds 700 11 kWh will receive the discount on that usage, even if heat pump load accounts for only a 12 portion of it. 13 Q Does the design of Rate 6 risk cost shifting to other customers? 14 A Yes. A Rate 6 customer using 900 kWh/month in the winter would pay only the 15 discounted Winter Block 2 rate on the 200 kWh above the threshold, agnostic of which 16 end use drives that consumption. To the extent that this usage has a higher coincidence 17 factor than what the Company assumed in designing the rate, Rate 6 will under-recover 18 the costs those customers impose on the system, shifting the recovery of these costs to all 19 customers. Further, the higher-usage customers who would benefit most from this design 45 Response to CLF-001. 26
  9. Page 29 of 48

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 tend to have higher incomes (e.g., customers with larger homes or EVs), meaning that the 2 cost shift also has negative equity implications.46 3 Q Does Rate 6 effectively incentivize shifting electricity usage to off-peak periods? 4 A No. Rate 6 is designed to make heat pump ownership more affordable when heat pump 5 electricity usage is highest. However, a heat pump owner who also charges an EV and 6 enrolls in Rate 6 would have no price incentive to shift that charging to off-peak periods. 7 The Company states that the time-of-day Rate 7 “would be expected” to incentivize EV 8 charging during off-peak periods but it has not evaluated how Rate 6 participation would 9 interact with this expectation.47 The Company also states that it considered two-block and 10 three-block TOU variants but rejected them on complexity or cost basis grounds,48 and 11 that it did not evaluate adding seasonality to its existing TOU rate due to complexity 12 concerns.49 13 14 B. Eversource’s proposed eligibility requirements for Rate 6 undermine the rate’s objectives 15 Q Which customers would be eligible for Rate 6? 16 A Rate 6 would be available to residential customers who switch from delivered fuel to an 17 air-source heat pump on or after January 1, 2026.50 Customers with electric resistance 18 heating would not be eligible because they already have a strong financial incentive to 19 switch to heat pumps.51 Customers switching from natural gas service would also be 46 High-income and EV ownership: Wang, Jiacheng, Harper, D., Hendrickson, C. 2026. Changing US electric vehicle ownership socioeconomic characteristics. Transportation Research Interdisciplinary Perspectives, Vol. 35. https://www.sciencedirect.com/science/article/pii/S2590198225004671. 47 Response to OCC-476b. 48 Response to OCC-478. 49 Response to OCC-476b. 50 Exh. CLP-RATES-1, at 31-32. 51 Exh. CLP-RATES-1, at 36-37. 27
  10. Page 30 of 48Match

    Docket No. 26-05-10 Prefiled Direct Testimony of Melissa Whited 1 ineligible: the Company asserts that conversion from gas heating would increase the 2 household’s total energy costs at current prices, which would defeat the core purpose of 3 Rate 6 as an affordability measure.52 4 Q 5 6 Why do Rate 6’s eligibility requirements undermine its own goal of improving winter system utilization? A The Company’s eligibility requirements would exclude customers who convert from gas 7 heating to heat pumps from Rate 6. The Company justifies this exclusion by stating that 8 “the rate is targeted at conversions that reduce the customer’s total household energy 9 costs” and a conversion from gas to a heat pump “typically increases the household’s 10 total energy bill at current prices.”53 However, a heat pump rate designed to lower winter 11 electric heating costs such as Rate 6 would help reduce energy costs for customers who 12 are converting from gas heating to a heat pump, and thus would not necessarily mean that 13 the conversion would increase a household’s total energy costs. Notably, the Company’s 14 Massachusetts affiliate, NSTAR Electric, estimated that a gas heating customer switching 15 to a heat pump would reduce total energy costs by approximately four percent under its 16 seasonal heat pump rate.54 17 The Company’s ultimate goal of making heat pump ownership more affordable to 18 improve winter system utilization and reduce overall system costs does not depend on 19 which fuel a customer heated with before converting. By barring gas customers who 20 convert to heat pumps from Rate 6, the Company would forgo additional load from these 52 Response to CLF-002. Response to CLF-002. 54 Petition of NSTAR Electric Company d/b/a Eversource Energy for Approval of Residential Seasonal Heat Pump Rates, D.P.U. 25-55, Order at 6 (July 29, 2025), available at: https://www.mass.gov/doc/25-55-order/download 53 28
Words on different pages
1 page match

As listed on the current system

Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Melissa Whited [26-05-10]