Page 135 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 133 Table 24. Summary of generation allocation approaches Resource type Legacy Classification and allocation methods Modern Evolving Nuclear Classification: Average and peak Energy allocator: All energy Demand allocator: 12 CP Classification: Equivalent peaker Energy allocator: All energy Demand allocator: Loss-of-energy expectation All hours Baseload coal Classification: Average and peak Energy allocator: All energy Demand allocator: 12 CP Probability of dispatch Hours dispatched Combined cycle Classification: Average and peak Energy allocator: All energy Demand allocator: 12 CP Probability of dispatch Hours dispatched or used for reserve Gas-fired steam Classification: Average and peak Energy allocator: On-peak energy Demand allocator: 4 CP* Probability of dispatch Hours dispatched or used for reserve Peaker Classification: 100% demand Demand allocator: 4 CP or 12 CP Probability of dispatch Hours dispatched or used for reserve Hydro Classification: Average and peak Energy allocator: All energy Demand allocator: 12 CP* Probability of dispatch Hours dispatched or used for reserve Wind Classification: 100% energy Energy allocator: All energy Classification: Equivalent peaker Energy allocator: All energy Demand allocator: Loss-of-energy expectation Hours of output Solar Classification: Average and peak Energy allocator: On-peak energy Demand allocator: 4 CP Classification: Equivalent peaker Energy allocator: All energy Demand allocator: Loss-of-energy expectation Hours of output Storage Classification: Average and peak Energy allocator: All energy Demand allocator: 12 CP Probability of dispatch Hours dispatched, used for reserve or reducing ramp rate Demand response Classification: 100% demand Demand allocator: 3 CP to 12 CP** Classification: 100% demand Hours dispatched or used for reserve Demand allocator: 3 CP to 12 CP** * Depends on use of resource ** Depends on program type and technology approach to the remaining costs. A hybrid approach is only that might be applied to the capital and nondispatch O&M as equitable as the component techniques but may be useful costs for various types of generation resources, whether where particular classification decisions can be made before utility-owned or purchased.129 This summary is, by its very the application of a generic approach to the residual costs. nature, highly simplified, ignoring many of the complexities Table 24 summarizes examples of allocation factors discussed in sections 9.1, 9.2 and 9.3. 129 The probability-of- dispatch and hourly approaches can also be applied to the short-run variable costs of the resources.Page 136 of 276
134 | ELECTRIC COST ALLOCATION FOR A NEW ERA For simplicity, we show an illustration only for generation investment-related costs. REGULATORY ASSISTANCE PROJECT (RAP)® Table 25. Illustrative annual generation data Net generation (MWhs) Annual nonfuel revenue requirement Annual nonfuel cost per MWh Baseload 1,860,000 $74,400,000 $40 Peaker 534,000 $42,720,000 $80 Solar 1,056,000 $31,680,000 $30 where 80% of baseload costs are considered Storage 62,000 $6,200,000 $100 to be energy-related. The illustrative load Total 3,512,000 $155,000,000 $44 Table 25 shows the amount of investment in each category, which we will then divide using multiple allocation methods. Table 26 shows two currently used methods: a legacy 1 CP system measure and a more modern method, equivalent peaker, data and allocation factors are from tables 5 through 7 in Chapter 5. Table 27 shows the calculation of an hourly allocation model, where baseload costs are apportioned to all hours, peaking and intermediate costs to midpeak hours, Disposition of net generation Storage input and delivery losses Sales to customers 412,000 3,100,000 Note: Numbers may not add up to total because of rounding. and storage only to the 2% of usage at the most extreme hours. Table 26. Allocation of generation capacity costs by traditional methods Residential Secondary commercial Primary industrial Street lighting 1 CP (legacy) $51,667,000 $62,000,000 $41,333,000 $0 Equivalent peaker $50,333,000 $52,400,000 $47,750,000 $4,517,000 Total $155,000,000 $155,000,000 Note: Numbers may not add up to total because of rounding. Table 27. Modern hourly allocation of generation capacity costs Residential Secondary commercial Primary industrial Street lighting Baseload (all hours) $24,000,000 $24,000,000 $24,000,000 $2,400,000 $74,400,000 Peaker (midpeak) $14,424,000 $15,735,000 $12,326,000 $236,000 $42,720,000 Solar (daytime) $10,560,000 $12,320,000 $8,800,000 $0 $31,680,000 Storage (critical peak) $2,366,000 $2,366,000 $1,420,000 $47,000 $6,200,000 Total hourly allocation $51,350,000 $54,421,000 $46,545,000 $2,683,000 $155,000,000 33% 35% 30% 2% 100% Composite hourly factor Note: Numbers may not add up to total because of rounding. TotalPage 137 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 135 10. Transmission in Embedded Cost of Service Studies A s discussed in Chapter 3, investments in transmission does not claim authority over (based on voltage, configura- lines and substations are needed and valuable for a tion, direction of power flow and other factors) is regulated wide assortment of purposes, including integrating by the state or consumer-owned utility governing body. inherently remote generation, allowing economic dispatch of If those subfunctions were classified and allocated in generation over large areas and providing backup reliability. the same manner, the division of the facilities by voltages Any particular transmission line and the substations to which would not matter. Unfortunately, some cost of service it is connected may perform multiple functions under varying studies allocate only the EHV facilities to certain customers load and generation conditions. Because the purposes for directly served from these facilities, with customers served constructing transmission and the use of the facilities vary so at subtransmission or distribution voltages being charged for widely, the allocation methods used may need to distinguish both the EHV system and the subtransmission. For example, among several categories of transmission. in 2013, Nova Scotia Power proposed to functionalize The generation-related portions of transmission 23% of transmission costs to subtransmission and excuse equipment — including switching stations, substations and from those costs the largest industrial customers, served transmission lines required to tie generators into the general at 138 kV (Nova Scotia Power, 2013b). Similarly, Manitoba transmission network and reinforcements of the transmis- Hydro functionalizes its 66-kV and 33-kV transmission lines sion system required by remote generation locations and by as subtransmission, which is allocated to all classes except economic dispatch — are often functionalized as generation. for the industrial customers served at voltages above 66 kV In regions with FERC-regulated ISOs or RTOs, state regulators may not have authority to determine the amount (Manitoba Public Utility Board, 2016). This approach is inequitable and fails to reflect of bulk transmission cost a local distribution utility must cost causality. The various voltages of transmission pay. The states may choose to allocate costs among classes in serve complementary functions. In general, customers a manner similar to that FERC uses to allocate costs among and distribution substations that are served from utilities and other parties. States also retain the authority to subtransmission would be more expensive to serve from allocate that cost using a different method than FERC uses EHV transmission. Subtransmission is a lower-cost for wholesale market allocation. alternative to EHV where the higher capacity of the EHV facilities is not required. 10.1 Subfunctionalizing Transmission As noted in Chapter 3, transmission of different voltage levels often serves similar functions. Nonetheless, some utilities have subfunctionalized transmission between extra-high-voltage (EHV) facilities (perhaps over 100 kV) and subtransmission (at lower voltages), sometimes called network transmission as it connects the different substations inside the utility service territory. Subtransmission that FERC For some systems, the subtransmission and EHV systems may seem to be serving different functions since the EHV lines may be more often networked or looped, while the subtransmission lines are often radial. This pattern is due to the higher load-carrying capacity of the EHV lines, which results in their being used in high-load backbone configurations. These lines are usually networked for greater reliability, not due to some inherent difference in the capabilities of the technologies. Higher-voltage linesPage 138 of 276
STANDARD OIL 2 N.N. STANDARD OIL 5 STANDARD OIL 4 STANDARD OIL 3 BARRETT STANDARD OIL 1 136 | ELECTRIC COST 580 ALLOCATION FOR A NEW ERA RICHMOND R VIRGINIA Briones Reservoir San Pablo Reservoir MIRA VISTA PLEASANT HILL REGULATORY ASSISTANCE PROJECT (RAP)® GEARY WALNUT CREEK PP RICHMOND Q EL CERRITO STA. G WALDO can be used in radial applications, and Ridge Berkeley F in some situations. Figure 36 is a section of a California transmission map, showing EHV lines as Russell solid lines (220 to 287 kV) and large dashed Oakland P Maritime 80 Commission, 2014). This excerpt shows some features that are consistent with the BANK OF AMERICA EMBARCADERO (SF Z) MOSCONE MISSION Oakland L Moraga Florence Schnitzer Steel Oakland C & I NCPA Alameda Naval Supply Center proposition that higher-voltage transmission San Francisco Upper San Leandro Reservoir Oakland X Oakland 580 Cartwright is networked while subtransmission is radial: SAN • A large backbone transmission line FRANCI SCO running north-south. Jenny POTRERO Owens Brockway Station J San Francisco Bay BAYSHORE Bancroft Edes HUNTE RS POINT A looped network of 110- to 161-kV lines • Lake Chabot Ward 280 coming off the backbone line into the Cherry San Leandro U Substations Oakland area. C Rossmoor Palo Seco as small dashed lines (California Energy • East Portal Claremont Oakland D lines (110 to 161 kV) and subtransmission BART SARANAP Orinda Grizzly Hillside Berkeley T Stuart SAUSALITO METER LARKIN WALNUT CREEK ARLINGTON Figure 36. SOLANO Transmission east of San Francisco Bay 24 subtransmission can be networked or looped 101 LAKEWOOD SOBRANTE OAK FAIRMONT Domtar #2 MARTIN Radial subtransmission lines that dead- Pacific Gas & Electric end at distribution substations in All other ownership DALY CITY But Figure 36 also illustrates situations 580 Castro Hayward O San Lorenzo Valley Transmission (color indicates utility ownership) Berkeley and parts of Oakland. Parsons Oriole Grant Soto LAWNDALE contradicting these stereotypes: SERRAMONTE • 33 to 92 kV EAST GRANDE – – – – – – 110 to 161 kV Networked subtransmission lines in the UNITED COGEN INC SHAW ROAD 220 to 287 kV San Leandro-San Lorenzo area. Mt. Eden Eastshore SAN FRANCISCO AIRPORT SNEATH LANE • SAN BRUNO Radial 220- to 287-kV lines that dead-end SANTA PAULA 880 (2014). Source: 92California Energy Commission. California Transmission Lines – Substations Enlargement Maps MA at such substations as Rossmoor and SAN ANDREAS Castro Valley. MILLBRAE AIR LIQUIDE CRVOGENICS JARVIS San Andreas BURLINGAME SAN MATEO Thus, the idea that the EHV system is a network and extent to which each class uses the subtransmission system the subtransmission system is a purely radial system served and not be designed simply as a benefit to high-voltage BERESFORD Pilarcitos Lake off the EHV network is a gross simplification. If loads to BAY MEADOWS near San Lorenzo were higher, for example, the local utility HILLSDALE might have upgraded the subtransmission network to higher CRYSTAL SPRINGS Lower Crystal Springs Reservoir voltages. If industrial customers served directly off the EHV system are ORACLE BELMONT RMC LONESTAR RALSTON so should the portion of distribution load served by SHREDDER 280 inappropriate in principle and impractical in application, SAN CARLOS 84 substations that are fed from EHV transmission. Although Upper Crystal leading to the conclusion that all voltages of transmission Reservoir WATERSHED should be allocated consistently as a single function. 35 However, if a state determines that subtransmission costs are to be allocated to the classes that use the subtransmission SAN MATEO system, ignoring the complementary nature of high- and low1 Not all distribution loads are served from subtransmission. excused from being allocated a share of the subtransmission, N.N. As a result, the separation of subtransmission is often HALFMOON BAY DUMBARTON industrial customers. CAROLANDS voltage transmission, the allocator should approximate the BAIR RAVENSWOOD REDWOOD CITY Redwoodfacilities City segregating EHV is typically performed in a manner TYCO ELECTRONICS BELLE HAVEN that benefits a small number of EHV industrial customers, COOLEY LANDING a full subfunctionalization of transmission for all classes EMERALD LAKE LAS PULGAS JEFFERSON GLENWOOD SRI INTL would sometimes reduce the allocation to classes served at COLORADO POWER STATION distribution, at the expense of the classes served directly WOODSIDE MENLO CARDINAL from the subtransmission system. STANFORD S.L.A.C. 82 AMES DISTRIBUTION AMES NASA MOFFET FIELD LOCKHEED 2 LOCKHEED 1 WHISMAN LAW LOS ALTOS ADV MICR MT. VIEW SIGNETICS WESTINGHOUSE BRITTONPage 139 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® A separate subtransmission allocator should approxi- ELECTRIC COST ALLOCATION FOR A NEW ERA | 137 generation (step-up transformers and generation ties for mate the following: many utilities; more extensive facilities for utilities with • An EHV industrial class that takes all its power from the extremely remote generators). Those facilities can either be EHV system would be allocated no subtransmission costs. functionalized as generation-related and classified along with A subtransmission industrial class that takes all its power the generation resource or functionalized as transmission and from the subtransmission system would be allocated classified in the same manner as the investment-related costs subtransmission costs in proportion to its entire load. of the associated generation. Facilities connecting peakers A general transmission class would be allocated should be treated as demand-related, while those connecting subtransmission costs in proportion to the fraction the baseload generation, especially remote generation, should of its load served from subtransmission. be primarily treated as energy-related since the facilities The distribution classes would be allocated subtrans- were built primarily to provide energy benefits. For example, mission costs in proportion to the fraction of their load Manitoba Hydro classifies as entirely energy-related the served from substations on the subtransmission lines. high-voltage direct current system that brings its northern Most large utilities appear to serve a significant fraction hydro generation to the southern load centers and export • • • of distribution load from the EHV system. The utility points, as well as its transmission interties, which allow for FERC Form 1 reports indicate that at least 26% of Southern economic energy exports and for off-peak energy imports to California Edison’s distribution substation capacity (the firm up hydro supplies in drought conditions.131 substations with low-side transformers below 30 kV) is In addition to the substations that step up the generator served from the EHV system; for Northern Indiana Public output to transmission voltages and the lines that connect Service, the portion is at least 49% (Federal Energy Regulatory the generator to the broader transmission network, many Commission, n.d.).130 utilities have transmission facilities that are integrated with 10.2 Classification The classification of transmission costs raises many of the the transmission network but are driven largely by the need to move large amounts of power from remote generators. Those transmission facilities may be identifiable because they same issues as the classification of generation costs and can were originally required to reinforce the transmission system often be dealt with in similar ways. As for generation, some when major baseload (or remote hydro or wind) resources approaches for transmission avoid the need for classification by were added or because they connect areas that have surplus assigning specific transmission facilities to the loads occurring generation to areas with generation shortages. For example, in the hours in which these lines serve customers with a utility may have 60% of its load in a central metropolitan improved reliability, lower variable costs or other benefits. area but 80% of its baseload resources far to the east or Some assets that are carried on the books as transmission may actually be related to interconnecting or integrating 130 Some distribution substation transformers are at substations serving multiple transmission voltages. The FERC Form 1 reports provide only the total transformer capacity at the substation, without differentiating among the EHV-subtransmission, EHV-distribution and EHV-EHV capacity. The percentages of distribution capacity served from the EHV system, listed above, do not include any of this multivoltage capacity. 131 The northern AC gathering system that brings the hydro to the HVDC converters is also classified as energy-related. 132 Examples of this phenomenon include Nova Scotia Power’s concentration of coal in the eastern end of the province; BC Hydro’s, Manitoba Hydro’s and Hydro-Quebec’s northern generation; PacifiCorp’s Rocky north, with multiple major transmission lines connecting the resource-rich east with the load in the center.132 Mountain Power division (with load concentrated around Salt Lake City and generation in Colorado, Wyoming, Arizona and Montana); Arizona Public Service Co. with load in Phoenix and generation in the Four Corners and Palo Verde areas; Puget Sound Energy and the Colstrip transmission system from Montana; the California utilities and the AC and DC interties to the Pacific Northwest and lines to the Southwest; and Texas’ concentration of wind generation in the Panhandle, serving load throughout ERCOT. This pattern is also emerging for California’s imports of solar energy from Nevada and Arizona, Minnesota’s imports of wind power from North Dakota and hydro energy from Manitoba, and the transfers of large amounts of wind power from generation in the western parts of Kansas and Oklahoma to load centers in the eastern parts of those states.Page 140 of 276
138 | ELECTRIC COST ALLOCATION FOR A NEW ERA Utility transmission system design typically lowers energy costs in at least three ways. First, a large portion of REGULATORY ASSISTANCE PROJECT (RAP)® Figure 37. Transmission system with uniformly distributed demand and generation many transmission systems is required to move power from City with 500 MWs peak demand the remote generators to the load centers and for export. If Transmission capacity generation were located nearer the load centers, the long, expensive transmission lines would not be required, and Generation = 6 x 100 MWs transmission losses would be smaller. These transmission 100 MWs Generation = 6 x 100 MWs costs were incurred as part of the trade-off against the higher operating costs of plants that could be located nearer the load centers — in other words, as a trade-off against energyrelated costs. This category includes transmission built to 100 MWs 100 MWs allow the addition of remote wind resources, which are often the least-cost energy resources even where the utility already has sufficient capacity and energy supply. In other Generation = 6 x 100 MWs 100 MWs Generation = 6 x 100 MWs cases, the remote wind resources may be more expensive than conventional resources, new or existing, but less expensive than local renewables (e.g., solar, wind turbines in areas with lower wind speed, higher land costs and more complex siting turbines in a third. Additional transmission corridors and problems) that would otherwise need to be built to comply substations are required to connect remote generation with energy-related renewable energy standards. (wind from one direction and hydro from another), and the Second, transmission systems are more expensive be- transmission lines between the load centers need to be beefed cause they are designed to allow for large transfers of energy up to support backup of the larger units and the economic between neighboring utilities. Third, transmission systems dispatch of the lowest-cost available generation to meet are designed to minimize energy losses and to function over load. In this more complex system, the incremental costs of extended hours of high loading. Were the system designed transmission (compared with the simple system in Figure 37) only to meet peak demands, a less costly system would should be classified as energy-related. suffice; in some cases, entire lines or circuits would not be It may be possible to identify and classify the costs of the required, voltage levels could be lower, and fewer or smaller individual lines or classify total costs in proportion to circuit- substations would be needed. miles of each voltage serving various energy functions. If all Figure 37 shows a simple illustrative system with relatively small units of a single generation resource else fails, a more judgment-based classification method, such as average and peak, may be the best feasible option. co-located with each load center. Since all the generators are PacifiCorp’s Rocky Mountain Power subsidiary in the same, economic dispatch does not require shipping power Utah classifies transmission as 75% demand-related and from one load center to another, so transmission is limited 25% energy-related (Steward, 2014, p. 7). This classification to the amount needed to allow reserve capacity in one center recognizes that, although peak loads are a major driver of to back up multiple outages in another center. In this simple transmission costs, a significant portion of transmission illustration, the transmission costs would truly be demand- costs is incurred to reduce energy costs. Since PacifiCorp related. has a large amount of transmission connecting remote Figure 38 on the next page illustrates a more complex coal plants in Wyoming, Arizona and Colorado to its load system, with baseload coal concentrated in one area, centers and connecting its Northwestern hydro assets to combined cycle generation in another and combustion its load centers, an even higher energy classification may bePage 141 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 139 Figure 38. Transmission system with remote and centralized generation 400 MWs hydro import 400 MWs Ws 0M 0 2 Generation = 3 x 300 MWs combined cycle 350 MWs City with 500 MWs peak demand Generation = 0 MWs 500 MWs Transmission capacity 500 MWs 500 MWs 600 MWs Generation = 8 x 100 MWs combustion turbine 600 MWs Generation = 3 x 400 MWs coal 200 MWs 600 MWs wind appropriate. PacifiCorp’s highest-voltage lines (500 kV, 345 kV should be classified to both energy and demand (Washington and 230 kV) primarily connect its load with remote baseload Utilities and Transportation Commission, 1981, p. 23). generation and would not be needed except to access Appropriate classification percentages will vary among low-cost energy. Those lines account for more than half of utilities and transmission owners. PacifiCorp’s transmission investment. Hence, more than half of PacifiCorp’s transmission revenue requirement is likely to be attributable to energy. Similarly, Nova Scotia Power has much of its generation (coal plants, storage hydro and an HVDC import of 10.3 Allocation Factors Historically, most cost of service studies have computed transmission allocation factors from some combination of monthly peak demands from 1 CP to 12 CP. hydropower from Newfoundland) in the eastern end of the Some utilities have recognized that transmission province, but most of its load is about 250 miles to the west. investments are justified by loads in more than one hour To reflect the large contribution of remote generation to its in a month. For example, Manitoba Hydro has used a transmission cost, the company uses an average-and-peak transmission allocator computed from class contribution to (system load factor) approach that effectively classifies about the highest 50 hours in the winter, Manitoba Hydro’s peak 62% to energy and 38% to demand (Nova Scotia Utility and period, and the highest 50 hours in the summer, the period Review Board, 2014, pp. 22-23). of Manitoba Hydro’s maximum exports, which also drive Washington state has explicitly rejected a single hour of peak as a determinant and ruled that transmission costs intraprovincial transmission construction (Manitoba Hydro, 2015, Appendix 3.1, p. 9).Page 142 of 276
140 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® The hours of maximum transmission loads may be (6) A transmission planning region may choose to different from the hours of maximum generation stress. For use a different cost allocation method for different types example, the power lines from remote baseload units to the of transmission facilities in the regional plan, such as load centers may be most heavily loaded at moderate demand transmission facilities needed for reliability, congestion levels. At high load levels, more of the low-cost remote relief or to achieve public policy requirements established generation may be used by load closer to the generator, while by state or federal laws or regulations (Federal Energy higher-cost generation in and near the load centers increases, Regulatory Commission, 2011, ¶ 586). reducing the long-distance transmission line loading. In addition, generator maintenance does not necessarily smooth The FERC guidance clearly anticipates differential out transmission reliability risk across months in the same treatment of transmission facilities built for different way that it spreads generation shortage risk. If transmission purposes. Aligning costs with benefits may require allocation loads peak in winter, when carrying capacity is higher, then of transmission costs to most or all hours in which a transmission peaks may not match even the maximum transmission facility provides service.133 transmission stress period. Demand-related transmission costs may be allocated In its Order 1000, establishing regional transmission to hours in proportion to the usage of the lines or to the planning and cost allocation principles, FERC includes the high-load hours in which transmission capacity may be following cost allocation principles, which recognize that tight following a contingency (the failure of some part of transmission is justified by multiple drivers and that different the system) or two. The high-load hours may be chosen as allocation approaches may be justified for different types of a more or less arbitrary number of the highest hours, as in transmission facilities: Manitoba, or as the hours in which loads on a particular line (1) The cost of transmission facilities must be or substation are high enough that the worst-case planning allocated to those … that benefit from those facilities in contingency (such as the loss of two lines) would leave the a manner that is at least roughly commensurate with transmission system with no more reserve than it has on the estimated benefits. In determining the beneficiaries of system peak with no contingencies.134 transmission facilities, a regional transmission planning process may consider benefits including, but not limited to, the extent to which transmission facilities, individually or in the aggregate, provide for maintaining reliability and sharing reserves, production cost savings and congestion relief, and/or meeting public policy requirements established by state or federal laws or regulations that may drive transmission needs. … (5) The cost allocation method and data requirements for determining benefits and identifying beneficiaries for a transmission facility must be transparent with adequate documentation to allow a stakeholder to determine how they were applied to a proposed transmission facility. 133 Attributing transmission to hours is more complicated than assigning generation costs by hours, because of the flow of electricity in a network. Once a transmission line is in service, power will flow over it any time there is a voltage differential between the ends of the line, whether or not the line was in any way needed to meet load in that hour. 10.4 Summary of Transmission Allocation Methods and Illustrative Examples The discussion above has indicated why transmission investments must be carefully scrutinized in the cost allocation process. Different transmission facilities provide different services and are thus appropriately allocated by different allocation methods. Table 28 on the next page lists some types of transmission facilities and identifies appropriate methods for each. Transmission is a very difficult challenge for the cost analyst because each transmission segment may have a 134 The latter definition would require load flow modeling for each transmission line or a representative sample; the practicality of this approach will depend on the extent of transmission modeling undertaken for system planning.Page 143 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 141 Table 28. Summary of transmission classification and allocation approaches Element Example methods Comments Hourly allocation Typically above 150 kV Mostly bidirectional Operates in all hours Allocate in proportion to usage or hours needed Bulk transmission Classification: To energy* — costs to allow centralized generation and economic dispatch; cost due to heating Energy allocator: All energy Demand allocator: Highest 100 hours • • • Integration of remote generation Classification: To energy* — costs to connect remote energy resources Energy allocator: All energy Demand allocator: Highest 100 hours Treat same as connected remote resources Allocate in same manner as remote resources Economy interconnections Classification: Energy and demand Depends on purpose and use of connection • Local network Classification: To energy* — cost due to heating Energy allocator: On-peak energy Demand allocator: 4 CP to 12 CP • • Allocate in proportion to usage or hours needed Transmission substations As lines** May also have distribution functions Typically below 150 kV Mostly radial • Allocate reliability value as equivalent peaker Allocate energy value in proportion to use As lines** * “To energy” = portion classified as energy-related ** “As lines” = in proportion to the classification or allocation of the lines served by each substation different history and purpose and that purpose may have particular types of transmission costs, including purchased changed over time. For example, a line originally built transmission service from another utility, a transmission- to connect a baseload generating unit that has since owning entity or an ISO. The illustrative data for the 1 CP been retired is repurposed to facilitate economic energy and equivalent peaker methods are from tables 5 through 7 interchange with nearby utilities. In Table 29, we use in Chapter 5, and the hourly allocation factor is derived in only three methods, which may or may not be relevant to Table 27 in Chapter 9. Table 29. Illustrative allocation of transmission costs by different methods Residential Secondary commercial Primary industrial 1 CP (legacy) $16,667,000 $20,000,000 $13,333,000 $0 $50,000,000 Equivalent peaker $16,237,000 $16,903,000 $15,403,000 $1,457,000 $50,000,000 Hourly $16,565,000 $17,555,000 $15,015,000 $866,000 $50,000,000 Note: Numbers may not add up to total because of rounding. Street lighting TotalPage 144 of 276
142 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® 11. Distribution in Embedded Cost of Service Studies D istribution costs are all incurred to deliver energy system (a primary line, a line transformer or a to customers and are primarily investment-related secondary line or network). costs that do not vary in response to load in the • Meters, which measure each customer’s energy short term. Different rate analysts approach these costs in use by month, TOU period or hour and sometimes very different ways. These costs are often divided into two by maximum demand in the month.135 Advanced categories. meters can also provide other capabilities, including 1. Shared distribution, which typically includes at least: measurement of voltage, remote sensing of outages, • and remote connection and disconnection.136 Distribution substations, both those that step power down from transmission voltages to distribution can be directly assigned to the corresponding rate distribution voltage (such as 25 kV) to a lower voltage classes. to other substations and to customer premises, serving only one customer. monitoring equipment. • 2. In some systems with low customer spatial density, a significant portion of primary lines and transformers underground conduit) and various control and • • Primary feeders, which run from the substations including the conductors, supports (poles and • Street lighting and signal equipment, which usually voltages and those that step it down from a higher (such as 12 kV). • • 11.1 Subfunctionalizing Distribution Costs Most line transformers, which step the primary One important issue in cost allocation is the deter- voltage down to secondary voltages (under 600 V, mination of the portion of distribution cost that is related and mostly in the 120 V and 240 V ranges) for use by to primary service (the costs of which are allocated to all customers. customers, except those served at transmission voltage) as A large portion of the secondary distribution lines, opposed to secondary service (the costs of which are borne which run from the line transformers to customer solely by the secondary voltage customers — residential, service lines or drops. some C&I customers, street lighting, etc.). The supervisory control and data acquisition Some plant accounts and associated expenses are equipment that monitors the system operation and easily subfunctionalized. Substations (which are all primary records system data. This is a network of sensors, equipment) have their own FERC accounts (plant accounts communication devices, computers, software and 360 to 362, expense accounts 582 and 592). In addition, typically a central control center. distribution substations take power from transmission lines Customer-specific costs, which include: and feed it into the distribution system at primary voltage. • Service drops connecting a customer (or multiple All distribution substations deliver only primary power and customers in a building) to the common distribution therefore should be subfunctionalized as 100% primary. 135 The Uniform System of Accounts treats meters as distribution plant and the costs of keeping the meters operable as distribution expenses, even though all other metering and billing costs are treated as customer accounts or A&G plant or expenses. Traditional meters that tally only customer usage are not really necessary for the operation of the distribution system, only for the billing function. As a result, references to meters in this chapter are quite limited, and the costs of meters are discussed with meter reading and billing in the next chapter. 136 These capabilities require additional supporting technology, some of which is also required to provide remote meter reading. These costs should be spread among a variety of functions, including distribution and retail services, as discussed in Section 11.5.
As listed on the current system