Page 171 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® that are disproportionately benefiting other classes or, ELECTRIC COST ALLOCATION FOR A NEW ERA | 169 Some investments provide not only demand response conversely, paying for energy efficiency for other classes and but also load shifting or energy efficiency. Examples include receiving little of the benefit. controls for water heaters, space cooling and space heating 14.2 Demand Response Program and Equipment Costs and swimming pool pumps. These programs can reduce energy costs, including increasing load in periods with excess renewables that would otherwise be curtailed. Allocation of Demand response programs may avoid generation, these costs should reflect the mix of benefits, including peak transmission and distribution investments depending on reductions, reduced reserve costs and reduced energy costs. the specifics of the program and may avoid high purchased For programs that are operated only infrequently under power and transmission costs incurred for peak periods or conditions of bulk generation shortage (e.g., industrial contingencies. The costs of marketing the programs, and interruptible load), the loads that were curtailed should be even payments to participants, may appear in a customer added back to the relevant class loads, and the costs of the service account, such as Account 908. Despite their location programs — both outreach and incentive payments — should in this account, the costs are not customer-related. They are be treated as purchased power and allocated either to genera- resource costs that benefit all customers. tion demand or to the specific hours when the program could Utility demand response programs are designed to avoid be called.183 Some utilities remove interruptible demand from capacity and energy costs and line losses for short-duration the associated class load before allocating costs and allocate loads during times of system stress. The program costs the costs of the program back to the participating class; that may include investments and expenses at utility offices approach can be reasonable, as long as the interruptibility (computers, software and labor), installations on the distri- provides benefits equivalent to the utility functions for which bution system (sensors and communication equipment) and the class allocation is reduced.184 In no case should a cost installations on customer premises (controls). These costs are of service study both reduce the participant class loads for incurred to avoid peak capacity (and sometimes associated demand response and allocate the costs to all classes; that energy) costs on the generation system and sometimes on the would double count the benefit to the participating class. transmission and distribution systems as well. Other programs with more frequent operations or wider The demand response costs should be functionalized benefits than emergency bulk generation should be assigned across all affected functions and allocated based on metrics more broadly to generation, transmission and distribution of peak usage that relate to the period for which they are based on program design. For example, if a demand response incurred — the hours contributing to highest stress. Where or storage program is developed simultaneously to improve demand response provides benefits outside the highest-stress the reliability and efficiency of the distribution system (i.e., hours, such as by providing operating reserves (which reduce a targeted nonwires alternative investment program) and the need to run uneconomic fossil-fueled generation), to provide bulk power benefits, the costs could be assigned a portion of the demand response costs should be allocated to the hours when demand response provides those benefits. 183 It is generally inappropriate to pay customers to participate in a demand response program, subtract demand response capacity from the loads used for deriving allocation factors and also allocate the costs of the program to nonparticipating classes. Paying the participants and reducing their class loads pays twice for the same resource. The participants should be paid, of course, but all load should pay for the service that the program provides. 184 Many legacy interruptible rates require long lead times, allow only a limited number of annual interruptions, limit the length of each partly to each function as discussed above.185 In certain cases, utilities may directly own demand interruption and allow customers to ride through an interruption for a modest penalty. These rates may reduce the cost of serving the interruptible customers but do not fully replace equivalent amounts of generation and transmission. 185 Although a program theoretically could be designed only to have targeted distribution benefits without bulk power benefits, that may not be the most cost-effective program design.Page 172 of 276
170 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® response or load management equipment at customer prem- and what they actually pay under discounted low-income ises to enable utility or consumer control of space condition- tariffs.187 Where those subsidies exist, the cost of service study ing, water heating, irrigation pumping and other loads. This must address how to recover the subsidies through adding to type of investment’s primary purpose is to enable peak load the revenue responsibility of other customers. The decision management, but it may also provide ancillary services and as to whether the subsidy should be recovered from the class shifting of energy between periods. Although located within whose members receive the discount or from all customers is the distribution system, it is functionally different from most a matter of public policy, which is sometimes settled by the other distribution system plant in that it directly offsets the legislature188 and other times left to the regulator’s judgment. need for generation and transmission expenditures. For this If the subsidy is recovered within the discounted class, the reason, these costs should be classified and allocated differ- discount does not affect cost allocation to the class because ently from other distribution plant. the costs remain within the class and the subsidy shows up in 14.3 Treatment of Discounts and Subsidies The decision to reduce the revenue responsibility of some customers increases the revenue responsibility of other the form of reduced revenues (and may thus result in higher rates for the remainder of the residential class). But if the subsidy is to be redistributed to other classes, it is appropriate for inclusion in the cost of service study as a cost or revenue adjustment to be apportioned across classes.189 customers. There are a variety of reasons for legislatures As a practical matter, recovering a subsidy from the and regulators to provide discounts. Some are cost-based nondiscounted customers in the class receiving the discount (such as for off-peak or interruptible service), in which case may just push more of those customers into distress. Hence, other customers are not truly providing a subsidy. Other the most reasonable manner of recovering a subsidy will discounts are truly subsidies, most commonly for low-income vary: If the residential class is mostly affluent, with small residential customers (unless justified by a substantially pockets of poverty, dealing with a low-income discount different load profile) and for financially distressed businesses entirely through rate design in the residential class may be — especially agricultural irrigation186 and businesses that are appropriate. But if most of the residential class is in a tenuous major employers. financial condition, but the commercial and industrial classes A common example is the difference between the in the territory are thriving, spreading the subsidy costs over revenues that low-income consumers would have paid under all classes may be most appropriate, with a net credit to the the standard residential tariff (or a tariff designed to recover residential class and charges to other classes, perhaps on an the costs appropriately allocated to a low-income class) energy basis. 186 For example, Nevada has a requirement that certain irrigators receive low rates: “IS-2 is a subsidized rate that NV Energy charges eligible agricultural customers who agree to interruptible irrigation pump service during certain situations. This service is applicable to electricity used solely to pump water to irrigate land for agricultural purposes. Agricultural purposes include growing crops, raising livestock or for other agricultural uses which involve production for sale, and which do not change the form of the agricultural product pursuant to NRS 587.290” (NV Energy, n.d.). 187 Low-income subsidies may be motivated by a combination of social concerns (such as reducing the burdens on needy customers and avoiding health-related problems of customers unable to heat or cool their homes), utility practicality (reducing bad debt and collection expenses) and cost causation. Low-income consumers are typically low-use customers and may tend to have less temperature-sensitive load that drives utility system peaks. Depending on the composition of the lowincome population, they may also be at home in a different pattern than higher-income customers. A time-differentiated cost study may illuminate these differences. 188 For example, California Public Utilities Code § 327(a)(7) requires that the low-income electric rate for its IOUs be allocated by equal cents per kWh to all customers except recipients of the low-income rate and street lighting customers. 189 For example, a pro forma adjustment to revenue for each class (positive to the residential class; negative to other classes) would spread the subsidy across all the classes that the regulator concludes should contribute to this service.Page 173 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 171 15. Revenues and Offsets in Embedded Cost of Service Studies 15.1 Off-System Sales Revenues S ome retail cost of service studies treat wholesale sales as a separate class and allocate costs to the off-system customers. The cost of service study does not neces- sarily lead to any change in the off-system customers’ charges (which are typically set by contracts, markets or FERC) but does help the regulator determine what share of the revenue the revenue from off-system sales should reflect classes’ contribution to the availability of capacity to make the sales.191 15.2 Customer Advances and Contributions in Aid of Construction requirement not recovered by FERC-regulated sales should be As discussed in Section 11.2, most utilities charge new borne by each retail class. Alternatively, many utilities allocate customers or new major loads for expansion of the delivery all their costs to the retail classes and credit the export system, at least in some circumstances. Utilities frequently revenues back to the retail classes.190 require customer advances for construction costs when they In the latter approach, utilities sometimes allocate are asked to build a facility to accommodate subsequent wholesale revenues to classes in proportion to their allocation load growth (e.g., to connect a subdivision or commercial of generation costs. Under this type of allocator, the greater development before some or perhaps any of the units are the rate class’s demand and usage, the greater its share of the built and sold). The utility requires the advance to transfer to off-system sales revenue. The problem with this approach is the developer the risk that the load will never materialize, or that some classes (e.g., industrials) use most of the generation that load will grow more slowly than expected. As the load capacity allocated to them throughout the year, while other materializes, the advances are refunded to the developer. classes typically pay for capacity they use in their peak season Those advances provide capital to the utility and generally are but which is available for sale in other seasons. Off-system treated as a reduction of rate base; that cost reduction should sales revenues depend not only on the retail customers’ be directly assigned to the customer classes for whom the financial support of the resources (including generating advances were made. capacity) from which off-system sales are made but also on Contributions in aid of construction are similar to the extent to which class load shapes leave resources available customer advances but are applied in situations in which the to make those sales. utility does not expect the incremental net revenues from the A more appropriate allocator would reward a class for load to cover the entire cost of the expansion. The contribu- having lower demand and usage, perhaps on a monthly tions are thus a permanent payment to the utility, offsetting basis, thereby leaving generation (and transmission) capacity part of the capital cost. Contributions in aid of construction available to support the off-system sales. In other words, should be treated similarly to customer advances, allocated as 190 The same approach is possible with retail customers whose rates are fixed under multiyear contracts. Off-system sales revenues may vary considerably, based on market conditions, and are therefore often included in a fuel adjustment clause or similar rider between rate cases, while the base allocation is typically established in a general rate case. 191 MidAmerican Energy in Iowa proposed an hourly cost allocation method for capacity and energy in a recent case but also argued that if the Iowa Utilities Board were to use its traditional “average and excess demand” method instead, off-system sales margins should be allocated by excess demand, not by energy. “MidAmerican believes it is more appropriate to allocate wholesale margins (revenues less fuel costs) based on the excess demand component of the [average and excess] allocator, as it is from excess generation capacity that wholesale sales can be made” (Rea, 2013, p. 19).Page 174 of 276
172 | ELECTRIC COST ALLOCATION FOR A NEW ERA rate base reductions for the class for which the contributions REGULATORY ASSISTANCE PROJECT (RAP)® accounts expenses and customer deposits. were made. Where that is not possible, they should be applied Auxiliary tariffed service revenues result from directly as realistically as possible to offset the rate base for the types charging customers for certain actions that customers take. of facilities for which the contributions were collected. The large majority of tariffed revenues result from items such As noted in Section 12.2, customer deposits that offset as service establishment charges, charges for reconnection rate base should be allocated consistently with uncollectible after disconnection, field collection charges and returned accounts expenses and late payment revenues. check charges. These revenues should not be allocated 15.3 Other Revenues and Miscellaneous Offsets The treatment of other operating revenues affects broadly because the revenues are predominantly paid by residential customers and the costs that these revenues reimburse are predominantly in customer-related accounts that are largely assigned to residential customers (accounts customer class allocation. Some cost of service studies allocate 586, 587, 901 to 903 and 905). These revenues should be all these revenues proportionally to a broad-based factor such directly assigned to the customer class that pays them or as base rate revenue. Others do a more granular analysis. The (if that is not possible) allocated in proportion to customer granular analysis is preferable analytically because it is closer accounts expenses excluding uncollectibles. to the basis for the revenues.192 There are several types of Tariffed service charges for costs associated with opting other operating revenue. Three of the largest are: out of AMI should be allocated in the same way as the costs of • Late payment revenues. AMI opt-outs (as discussed in Section 12.1). • Revenues for auxiliary tariffed services. Rents should be allocated to the function causing the • Rents and pole attachment revenues. rents (distribution lines, office buildings, etc.). In particular, As discussed in Section 12.2 earlier, late payment pole attachment revenues from cable and telecommunica- revenues need to be treated consistently with uncollectible tions companies should be allocated in proportion to poles. 192 For example, assigning revenues from service establishment charges based on total base rate revenue would result in large customers, who rarely move, receiving revenue as if they had moved many times in a single year.Page 175 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 173 16. Differential Treatment of New Resources and New Loads I n some situations, regulators have treated new resources higher than near-term incremental costs; for example, or new loads using considerations that do not fit neatly in determining how to apportion the cost burden into the embedded cost of service study framework. In of economic development programs or low-income particular, equity may sometimes be improved by reflecting the history and projections of class loads. However, there assistance programs. • Developing desired end uses that may require prefer- are risks in adopting such an approach, particularly within ential rates in the short term (e.g., electric vehicles or customer classes. Regulators should be careful to ensure docked ships that would otherwise be burning oil) to adoption of such techniques is not arbitrary or discriminatory provide a societal benefit or stimulate a desirable market. and is grounded in solid reasoning. In most cases, the differential treatment is intended to These differential treatment techniques are sometimes protect customers in the other classes from higher costs of referred to as incremental cost of service studies193 and can new resources or from bearing a larger share of legacy costs. be conceptualized as either applying two different embedded cost techniques or combining an embedded cost technique with a marginal cost technique. In either case, the defining characteristic of these methods is the recognition that the costs associated with load growth in the recent past or the relatively near future, which typically might be several years, are being driven by a specific class or subclass of customers. Incremental cost considerations are sometimes used to address a special circumstance that justifies differential treatment for particular classes or subclasses of customers within the context of an embedded cost study. Examples include: • Allocating legacy low-cost generation resources to classes in proportion to their contribution to loads in a past year (perhaps the last year in which those resources were adequate to serve load), with the higher incremental costs of newer generation allocated to classes in proportion to their load growth since that base year. • Setting the revenue requirements for selected classes or subclasses at levels below the general cost allocation but 193 The term “incremental cost of service study” in this case is not used in the same sense as a marginal cost of service study, where the marginal impact of load patterns is measured. 194 In principle, there could be similar differences in the costs of some customer service elements, such as between an existing billing system that would be adequate indefinitely for the existing accounts and an expensive new system that would be required if the utility adds accounts. 16.1 Identifying a Role for Differential Treatment A study with differential treatment typically looks at the costs the system will incur within a relatively short time horizon to serve new load or retain existing load. The costs that may differ between the legacy loads and resources and incremental loads and resources include the variable costs of existing generation resources and the costs of new supply resources, transmission projects and distribution upgrades.194 In each case, inequities or inefficiencies arise because costs do not scale proportionally to the drivers, such as load. If the utility has committed generation resources, with low variable costs, in excess of its requirements and has overbuilt most of its transmission and distribution circuits, incremental costs will tend to be below average costs.195 In contrast, in a period of tight supply, the near-term costs of running expensive generation and adding generation, transmission and distribution resources may be higher than embedded costs. 195 Surplus capacity does not always imply that incremental costs are below average costs. If the utility can save money by selling surplus generation resources or shutting them down, the incremental cost of retaining or increasing load may be as high as the embedded costs or nearly so.Page 176 of 276
174 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Figure 43. US load growth by customer class since 1990 Class sales as percentage of 1990 190% 170% Residential Commercial Industrial 150% 130% 110% 90% 1990 1995 2000 2005 2010 2015 Data source: U.S. Energy Information Administration. Form EIA-861M Sales and Revenue: 1990-Current In some cases, growth has profound impacts on system • The particular needs of the growing loads, such as higher costs, and special consideration of differential growth rates reliability or power quality, or three-phase service in may be important to the regulator. Load growth at certain areas with mostly single-phase service. hours may be beneficial, while load growth at other hours Most traditional embedded and marginal cost studies may be problematic, requiring new resources. Those facilities do not take differential growth into account. U.S. residential may be more expensive than the existing equivalents due to loads grew about 50% from 1990 to the 2008 recession and any of the following: not at all since; commercial loads grew about 80% up to the • Inflation: Equipment built 20 years ago will usually be recession and slightly since; and total industrial electricity less expensive than the same equipment installed today; consumption grew slowly to about 2000 and has declined buying new sites for generation or substations may be slowly since, as shown in Figure 43 (U.S. Energy Information many times the embedded costs of sites purchased in the Administration, n.d.-b). Load growth patterns for individual 1950s. utilities may be much more disparate, both among customer Location: Existing generation may be located near load classes and between clearly distinguishable subclasses (such centers, while new generation may be required to locate as urban and rural, small markets and big-box stores, or farms much farther away; the existing distribution system may and mines). • be relatively dense, while the new loads require long line • • Where incremental costs are much higher than embed- extensions. ded costs, the difference may be assigned to classes in propor- Regulatory standards: The utility may be required to tion to their growth. If it is a subset of a class that is growing locate new lines underground;196 environmental standards quickly, there may be a rationale for adopting separate tariffs for routing, construction and emissions are often more or riders for new customers within that class or for an identi- restrictive for new resources than existing ones. fiable subgroup contributing to higher costs (e.g., large vaca- Exhaustion of favorable opportunities: A utility may tion homes or data centers). The correct answer in some cases have relied historically on low-cost hydro, while its new is the creation of a new customer class with separate load and resources may be much more expensive; ideal sites for cost characteristics. Beyond cost allocation, the incremental wind power tend to be the first ones developed, while less costs may be reflected in rate design and connection fees. For favorable sites are generally developed later. 196 Undergrounding may also be required by the difficulty in finding room for overhead transmission through built-up areas.Page 177 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 175 Figure 44. Estimated revenue and cost from serving additional electric vehicle load Present value per vehicle (2014 dollars) $20,000 $9,295 $18,000 $16,000 $14,000 Net revenue Carbon cost Rate base Capacity cost Renewable portfolio standard cost Energy cost $4,474 $12,000 $3,574 $2,591 $10,000 $8,000 $6,000 $4,000 $2,000 $0 Cost Revenue (utility bills) Cost Revenue (utility bills) Tiered rate Flat rate Revenue (utility bills) Cost Mixed flat and time-of-use rate Revenue (utility bills) Cost Time-of-use rate Source: Energy and Environmental Economics. (2014). California Transportation Electrification Assessment — Phase 2: Grid Impacts example, higher costs may also be allocated to the entire class but collected through a rate element (e.g., consumption over twice the monthly average) that aligns well with the customers causing the additional costs. In some situations, load growth can reduce system average costs, at least temporarily, by spreading embedded costs over more units of sales. Regulators sometimes reduce rates to a special class or particular customers who will demonstrably generate more revenue with the lower rates, such as with economic development and load retention rates. At the present time, this may apply to beneficial electrification of transportation. Figure 44 shows a calculation of how additional electric vehicle load would generate additional net revenue, thus creating opportunity to benefit new EV users and existing consumers (Energy and Environmental Economics, 2014). Some generation resources, such as federal hydropower entitlements, are made available to utilities by statute to serve particular loads, such as residential customers. Many regulators allocate those benefits to the classes whose entitlement to the power makes it available to the utility.197 16.2 Illustrative and Actual Examples of Differential Treatment Table 37 on the next page shows an illustrative incremental cost study. In this simplified example, costs are rising; many are directly related to growth, but some are not. Costs relating to growth are assigned to the classes in proportion to their growth. Costs not related to growth are assigned based on each class share of current usage. The result, where both classes start at the same usage level but one grows four times as quickly as the other, is that the growth-related costs are assigned to the growing class, increasing its revenue responsibility if its costs are greater than current rates or decreasing its responsibility if its costs are lower than current rates. In this illustration, both classes had equal rates in the previous rate proceeding. But costs have risen for both nongrowth categories (inflation) and growth categories (new resources and new distribution capacity). After application of an incremental cost study, the slow-growing class is assigned a rate averaging 197 Those benefits are often reflected in rate design by development of a lower first energy block to ensure that each eligible customer gets an appropriate share of the benefit.Page 178 of 276
176 | ELECTRIC COST ALLOCATION FOR A NEW ERA 14 cents per kWh, while the fast-growing class is assigned an REGULATORY ASSISTANCE PROJECT (RAP)® Table 37. Illustrative cost study with differential treatment of new resources Total Residential Commercial and industrial $200,000,000 $100,000,000 $100,000,000 Previous usage (MWhs) 2,000,000 1,000,000 1,000,000 Current rates per kWh $0.10 $0.10 $0.10 Usage In current rate period (MWhs) 2,250,000 1,050,000 1,200,000 Growth from previous (MWhs) 250,000 50,000 200,000 Class share of growth 20% 80% Class share of current 46.7% 53.3% average of 17 cents per kWh. In the opposite situation, where incremental costs are lower than average costs, the growing class might be assigned lower costs. 16.2.1 Real-World Examples This section describes specific applications of differential treatment in cost allocation to illustrate the range of concepts. Seattle City Light 1980 Cost Allocation In 1980, Seattle City Light, a municipal utility, was experi- Revenues at previous usage Growth-related costs $100,000,000 $20,000,000 $80,000,000 Nongrowth costs $50,000,000 $23,335,000 $26,667,000 All increased costs $150,000,000 $43,335,000 $106,667,000 Total revenue requirement $350,000,000 $143,335,000 $206,667,000 Usage in current rate period (MWhs) 1,050,000 1,200,000 New rates per kWh $0.14 $0.17 Note: Numbers may not add up to total because of rounding. encing rapid growth in commercial loads with stagnant to declining industrial loads. It This approach resulted in an average increase in resi- recognized that continued growth would require it to commit dential rates, an above-average rate increase to commercial to new nuclear or coal plants with incremental power costs customers and a below-average rate increase to industrial much higher than the embedded hydro resources. Average customers. It achieved the stated equity goal of charging rates were about 2 cents per kWh, while just the expected cost more to the fastest-growing customer class — that is, the of new generation resources was about five times that level. class that was driving the lion’s share of the incremental costs. Even without the new resources, Seattle City Light required a rate increase and developed an interclass cost allocation method along the following lines:198 • • • Vermont Hydro Allocation The state of Vermont receives an allocation of low-cost Starting with historical-year sales by class and prior year power from the Niagara and St. Lawrence hydroelectric revenues by class. facilities owned by the New York Power Authority, pursuant Assigning the costs related to growth in proportion to to a requirement in statute that allowed construction of the sales to each class, using forecast sales and expected the plants, to provide power to Vermont.199 The Burlington long-term resource acquisition costs. Electric Department allocates this power to the residential Apportioning the residual revenue requirement increase customer class.200 Other classes do not benefit from this on a uniform basis to all customer classes. resource. This is a method of ensuring that limited low-cost 198 One of the authors of this manual, Jim Lazar, participated in this proceeding on behalf of an intervenor. 199 “In order to assure that at least 50 per centum of the project power shall be available for sale and distribution primarily for the benefit of the people as consumers, particularly domestic and rural consumers, to whom such power shall be made available at the lowest rates reasonably possible” (Niagara Redevelopment Act, Pub. L. No.85-159, 16 U.S.C. § 836[b][1]). NYPA was required to provide a portion of the power to public bodies and co-ops in neighboring states (16 U.S.C. § 836[b][1]). Thus, the resources were made available to the Burlington Electric Department for the purpose of benefiting residential customers. 200 The Burlington Electric Department also uses that allocation to create an inclining block rate design consisting of a customer charge to cover billing, collection and other customer-specific costs; an initial block priced at the New York Power Authority cost plus average T&D costs; and a tail block that pays for other generation resources plus average T&D costs. See Burlington Electric Department (2019).Page 179 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | the New York Power Authority provides the power and that Nova Scotia Power Load Retention and Economic Development Rates all customers share the cost of incremental resources needed In 2011, falling global demand for paper resulted in the resources are equitably allocated to the customers for whom to serve demand in excess of incremental usage.201 177 bankruptcy and shutdown of two paper mills that were Nova Scotia Power’s largest customers, which accounted for about Northwest Power Act — New Large Single Loads 20% of its sales and 12% of its revenues. The mills had been The Pacific Northwest Electric Power Planning and major employers, both directly and as purchasers of wood Conservation Act of 1980 provided, among other things, for harvested from forests in the province. A buyer emerged for division of the economic benefits of the federal Columbia the larger of those facilities, contingent on a variety of sup- River power system among various customer groups and rate portive policies from the provincial and federal governments, pools (Pub. L. No. 96-501; 16 U.S.C. § 839 et seq.). The act set including favorable tax treatment and rates. forth a specific mechanism for the Bonneville Power Admin- Nova Scotia Power proposed and the Nova Scotia Utility istration to charge a price based on new resources to “new and Review Board approved (with modifications) a load reten- large single loads” (discrete load increments of 10 average tion rate that would charge the mill hourly marginal fuel and MWs or 87,600 MWhs per year, such as might be experienced purchased power costs (including opportunity costs from lost if a new oil refinery were built). This provision was intended exports), plus administrative charges and mill rates to cover to protect existing consumers from rate increases that could variable O&M, variable capital expenditures and a contribu- result from new very large loads attracted by the low average tion to capital investments and long-term O&M. The load generation costs in the region, in a period in which new would be entirely interruptible, and the utility committed to resources were very expensive. Table 38 shows average rates excluding the mill’s load from its planning and commitment for Bonneville Power Administration by category for recent decisions (Nova Scotia Utility and Review Board, 2012). years, including a higher rate for new resources (Bonneville The determination of Nova Scotia Power’s hourly Power Administration, n.d.).202 marginal costs proved to be more difficult than expected.203 Nonetheless, the rate design succeeded in attracting the Table 38. Bonneville Power Administration rate summary, October 2017 to September 2019 Rate category Average rates per MWh Priority firm public utility average $36.96 Priority firm public utility Tier 1 $35.57 Priority firm – IOU residential load $61.86 Industrial power $43.51 New resources $78.95 Source: Bonneville Power Administration. Current Power Rates 201 This same concept has been the foundation of inclining block rates in Washington state and Indonesia. 202 The average rates subsume a variety of fixed and variable charges. 203 Nova Scotia Power was not part of an energy market and had limited connections to its only neighboring utility (NB Power, which is also not part of an energy market), and its marginal generation resources are coal investment necessary to restart and retain the mill as an employer while producing some contribution to Nova Scotia Power’s embedded costs. The load retention tariff expires in 2020, at which time the mill may switch to a firm rate or negotiate a new load retention tariff.204 Chelan County Public Utility District Bitcoin Rate The creation of bitcoin cryptocurrency units requires energy-intensive mathematical computations called mining. To limit the cost of their operations, bitcoin “miners” have sought locations with low-priced electricity. Those operations plants with long commitment horizons (Rudkevich, Hornby and Luckow, 2014). 204 The Nova Scotia Power system will operate differently after 2020, when it is expected to have access to large amounts of Newfoundland hydro energy and operate under stricter carbon emissions standards. Any new load retention tariff would need to reflect those changes.Page 180 of 276
178 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® typically require very large amounts of power but have few declared a moratorium on new connections and developed on-site employees and little local economic benefit. One of a tariff designed to ensure that any growth of this type of these locations is Chelan County in Washington state, where load would not adversely affect other consumers or the local the local public utility district owns two very large dams on economy (Chelan County Public Utility District, 2018). This the Columbia River and has industrial rates about one-fourth tariff is geographically differentiated, to recognize areas of the national average.205 where transmission and distribution capacity are available, Chelan County Public Utility District’s existing low-cost resource is fully obligated to a combination of local retail use and includes: • and long-term contract sales. The contract sales prices are above the average retail rates, bringing significant revenue to Payment in a one-time charge of transmission and distribution system costs to serve large new loads. • A price for electricity, tied to (generally higher) regional fund public infrastructure in the county, including a world- wholesale market prices, not Chelan County Public class parks network. When the district received applications Utility District system costs. for service from bitcoin miners, it decided that this high- • Severe penalties for excess usage that could threaten density load growth would not be in the public interest, system reliability. 205 The Chelan County Public Utility District rate for primary industrial customers up to 5 MWs with an 80% load factor is 1.91 cents per kWh (Chelan County Public Utility District, n.d.). The average U.S. industrial price was 6.88 cents per kWh in 2017 (U.S. Energy Information Administration, 2018, Table 5.c).
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Melissa Whited [26-05-10]