    36 | ELECTRIC COST ALLOCATION FOR A NEW ERA distribution level. The distribution system receives power REGULATORY ASSISTANCE PROJECT (RAP)® In urban and suburban settings, a typical transformer will primarily from the transmission system through distribution serve several residential customers or small businesses, either substations, which convert power from higher transmis- in one building or several buildings that are relatively close to sion-level voltages down to distribution-level voltages. Some one another. Typically, an apartment building is served by a power may be delivered to the distribution system directly larger transformer than would serve single-family dwellings, from small generators, such as small hydro plants and distrib- but the transformer or multitransformer installation could uted generation. Distribution substations are smaller versions serve dozens or even hundreds of customers. A single large of transmission substations.13 These are often connected by secondary customer is usually served by one or more ded- subtransmission lines, which may be functionalized as either icated transformers, and in exurban and rural areas even a transmission or distribution in cost studies. Collectively, the relatively small customer may be so far away from neighbors transmission and distribution systems are referred to as T&D as to require a dedicated transformer. or as the delivery system. From each substation, one or more distribution feeders Some secondary voltage customers will be served directly by a service line from the transformer to their buildings. Other operating between 2 kV and 34 kV, known as primary voltage customers farther up the road will be fed from a secondary lines, run as far as a few miles, typically along roadways. distribution line from a nearby transformer that is attached to These are mostly on wooden utility poles shared with the same poles as the primary feeder but lower down. Second- telephone and cable services or in underground conduit. ary voltage lines in older neighborhoods served with overhead A single pole or underground route may carry multiple wires are often networked among several transformers. For circuits. Each feeder may branch off to serve customers many utilities, underground secondary lines in modern neigh- on side streets. Although distribution feeders leaving the borhoods generally are not networked. Underground service substations are usually three-phase, like the transmission is generally more expensive than overhead service but often lines, branches that do not carry much load may be built as required by local regulations for aesthetics or reliability reasons. single-phase lines with just two wires. Some customers take power directly at primary voltage Figure 9 on the next page illustrates one relatively common arrangement. In this example, each transformer serves (usually 2 kV to 34 kV) and transform it down within their two houses directly with service lines, and feeds secondary premises to a secondary voltage (600 volts or less) or use it lines from which service lines run to two or three other hous- directly in high-voltage equipment. All residential and most es on the same side of the street and four or five houses across commercial customers take service at secondary voltages, the street. The illustration is for an underground system. The which typically range from 120 V to 480 V. For that purpose, basic layout of an overhead system would be similar. Howev- the utility must provide line transformers, which are the er, since it is easier to string overhead service lines across the large cylinders on some utility poles for overhead distribution street than to dig lines under the street, service lines might and the ground-mounted metal boxes near buildings for run directly from an overhead transformer to one or two underground distribution. There is a frequently used houses across the street, and the secondary might just run on shorthand in which customers served at primary voltage are the transformers’ side of the street, with service lines crossing referred to as primary customers and any customer classes the street to additional customers. The key factor here for distinguished on this basis are described as primary — for cost allocation purposes is that even secondary voltage lines example, primary general service or primary commercial. are often shared among multiple customers and are not a Similarly, customers served at secondary voltage can be direct cost responsibility of any one of them individually. described as secondary customers, and customer classes distinguished on that basis are referred to as secondary — for example, secondary general service or secondary commercial. 13 In some cases, a higher-voltage distribution line (e.g., 13 kV) may power a lower-voltage line (e.g., 4 kV) through a substation.
  2. Page 39 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 37 Riser poles Open point Figure 9. Underground distribution circuit with radial secondary lines Pad-mounted transformer Primary distribution line Secondary distribution line Service line Note: Overhead primary lines run down the riser poles and go underground. Figure 10 shows a portion of a similar distribution circuit Figure 11 on the next page illustrates a typical overhead but highlights the difference that in this case the secondary distribution pole, showing the primary lines, a transformer, lines are networked, meaning power can flow to the relevant an electric service to one home and secondary lines running customers over both transformers simultaneously. This in both directions to serve multiple homes. allows each transformer to serve as backup for the others The final step in the delivery of power from the utility to in that network and allows for more flexible operation to the customer is the service line, or drop,14 from the common minimize losses and prevent overloads. distribution facilities in the public right of way to the Figure 10. Detail of underground distribution circuit with networked secondary lines customer’s meter. That line may be overhead or underground. Even where the distribution service is overhead, customers may be served by an underground service drop out of concerns for aesthetics or reliability, since underground lines are not vulnerable to damage from wind or trees. For primary voltage customers, the service drop is a line at the primary voltage, attached to one or more phases of primary feeder. For secondary customers, the service drop may run from the transformer to the customer or from a convenient point along the secondary lines. Pad-mounted transformer Primary distribution line Secondary distribution line Service line 14 Since overhead service lines often slope down from their connection on the utility pole to the attachment point on the customer’s building, they tend to literally “drop” the service down to the customer.
  3. Page 40 of 276

    38 | ELECTRIC COST ALLOCATION FOR A NEW ERA Figure 11. Secondary distribution pole layout REGULATORY ASSISTANCE PROJECT (RAP)® Figure 12. Electric delivery system line losses Generator Primary lines (up to 13.2 kV) Losses in step-up transformers Transformer reduces primary voltage to secondary voltage Losses in transmission lines and substations Service line (up to 240 V) Secondary lines (up to 240 V) Losses in distribution substation Transmission customers Losses in primary feeders 3.1.4 Line Losses For most purposes in a cost allocation study, line losses Losses in line transformers are not broken out as a separate category of costs. However, Primary voltage customers the physics of energy flowing over transmission and distribution lines can lead to nontrivial costs. A line loss study is an important input into a cost of service study because it helps determine the differential cost allocations to customers Customers served from transformer Losses in secondary lines served at different voltages. A small percentage of power is lost in the form of heat as it flows through each component of the delivery system, as discussed at length in Lazar and Baldwin (2011). The losses in Other customers on secondary Losses in service line conductors, including transmission and distribution lines, are known as resistive loss. Resistive loss varies with the square of the quantity of power flowing through the wire. Because of Secondary customer this exponential relationship between load and losses, a 1% reduction in load reduces resistive losses by about 2%. are around 7%, but marginal losses can be much higher, more The levels of conductor losses from the generators to than 20% during peak periods (Lazar and Baldwin, 2011, p. 1). a customer at secondary voltage (such as a residential Reducing a customer’s load (or serving that load with an customer) are illustrated in Figure 12. Transformers have on-site generation or storage resource) reduces the losses in more complex loss formulae because a certain amount of the service drop from the street to the customer, the second- energy is expended to energize the transformer (core losses) ary line (if any) serving that customer, the line transformers, and then all energy flowing through the transformer is the distribution feeder, the distribution substation, and subject to resistive losses. Average annual line losses typically transmission lines and transmission substations. Lower loads,
  4. Page 41 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 39 on-site generation and storage also reduce the generation expected bills in order to keep the utilities whole. Bills may go capacity and reserve requirements, meaning that a 1-kW unpaid because of customer financial difficulties, departure reduction in load at the customer’s premises can avoid nearly from the service territory or any number of other factors. In 1.5 kWs of generating capacity at a central source (Lazar and some jurisdictions, deposits are required to protect utilities Baldwin, 2011, p. 7). from unpaid bills. Utilities often use their ability to shut off electric service to a customer to ensure bill payment, and 3.1.5 Billing and Customer Service Traditionally, metering is considered a customer-specific expense for the purpose of billing. Advanced metering infrastructure is used for a much wider array of purposes, many jurisdictions implement shutoff protections to ensure that customers are not denied access to necessary or lifepreserving services. Customer service spans a whole range of services, from however, such as energy management and system planning. answering simple questions about billing to addressing This indicates that broader cost allocation techniques should complex interconnection issues for distributed generation. be used. Historically, meter reading was a substantial labor These expenses may vary greatly by the type of customer. expense, with meter readers visiting each meter every billing Many utilities have “key accounts” specialists who are highly cycle to determine usage. However, utilities with either AMI trained to meet the needs of very large customers. Large or AMR technology have either eliminated or greatly reduced customers typically have more complex billing arrangements, the labor expenses involved. Customers that opt out of AMI such as campus billing, interruptible rates and other often incur special meter reading costs, if meter readers are elements that require more time from engineering, legal and needed for a small number of customers. rate staff, as well as higher management. Some utilities lump Most utilities bill customers either monthly or bimonthly these customer services together. The better practice is to for a variety of related practical reasons. If customers were keep them separate based on how each rate class incurs costs billed less frequently, the bills for some customers would be and benefits from the expenses. very large and unmanageable without substantial planning. If Some utilities also characterize various public policy billed more frequently, the billing costs would be significantly programs, such as energy efficiency programs, as customer higher. Billing closer to the time of consumption provides service, but this is typically a mistake because these costs are customers with a better understanding of their usage pat- not related to the number of customers. Instead, they relate terns from month to month, which may help them increase to the power supply and delivery system capacity and energy efficiency and respond to price signals. There are exceptions, benefits the programs provide. since many water utilities, sewer utilities and even a few Some states allow utilities to include general marketing electric utilities serving seasonal properties may render bills and advertising efforts in rates, but others require share- only once or twice a year.15 holders to fund any such efforts. More narrowly targeted Related to billing and metering, there are a range of in- energy conservation and safety advertising expenses are often vestments and expenses needed to store billing data and issue recovered from ratepayers as a part of public policy programs. bills. Historically, billing data was quite simple, and the cost of issuing bills was primarily printing and mailing costs. With AMI, billing data has grown substantially more complex, and additional system and cybersecurity requirements are needed. 3.1.6 Public Policy Program Expenditures States have mandated that utilities make expenditures for Conversely, online billing can lower certain costs and provide various public policy purposes. One of the largest is energy easier access to customer data. efficiency, but others include pollution control, low-income The expenses of unpaid bills are known as uncollectibles and typically are included as an adjustment in the determination of the revenue requirement as a percentage of 15 This is also the case for California customers who opt out of AMI (California Public Utilities Commission, 2014).
  5. Page 42 of 276

    40 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® customer assistance, renewable resources, storage and the members and customers, IOUs include a return on hardening of the system to resist storm damage. Each of these investment, specifically a return on equity for shareholders, in cost centers has a place in the cost allocation study, and each the calculation of the revenue requirement. This is typically must be treated based on the purpose for which the cost is calculated as the net rate base (gross plant net of accumulated incurred. depreciation) multiplied by the weighted average rate of return, which is composed of the interest rate on debt and the 3.1.7 Administrative and General Costs Utilities also have a wide variety of overhead costs, typically called administrative and general costs. They include allowed return on equity. In many states, utility commissions regulate only IOUs. Publicly owned utilities — including municipal utilities, necessary capital investments, known as general plant, and or munis, and public power districts — serve about 15% of ongoing expenses, typically called A&G expenses. General American homes and have about 7% of electric distribution plant includes office buildings, vehicles and computer circuit miles (National Rural Electric Cooperative Association, systems. A&G expenses include executive salaries, pensions 2017). Many of the areas served are urban, and municipal for retired employees and the expenses due to regulatory utilities often provide other services as well, such as water, proceedings. The common thread is that these costs support sewer and natural gas. These utilities evolved for a variety of all of a utility’s functions. reasons but typically are not subject to state or federal income 3.2 Types of Utilities Utilities differ in terms of ownership structure and the tax (but typically pay many other types of taxes) and do not include a return on equity in rates. For this reason, their rates tend to be lower than those of most IOUs. The state or local types of assets they own. The many types of electric utility governmental entity that sets up this type of utility also deter- organizations have different characteristics that may lead to mines the governing structure for the utility, which could be different cost allocation issues and solutions. Nationwide, an elected or appointed board. Typically this board will hire a publicly owned utilities typically have lower rates. In 2016, professional manager to oversee the utility. Many municipal the average residential customer served by public power paid utilities also determine their annual revenue requirement on 11.55 cents per kWh, compared with 11.62 cents for co-ops and a cash flow basis, which can lead to greater annual variability. 13.09 cents for customers served by investor-owned utilities, In most cases, state public utility commissions have little or reflecting a mix of service territory characteristics and dif- no authority over munis and public power districts. fering sources of electricity, costs of capital and tax burdens Electric cooperatives are nonprofit membership corpora- (Zummo, 2018). Some utilities are also vertically integrated, tions or special purpose districts that provide service to about owning generation, transmission and distribution assets 12% of Americans and own about 42% of electric distribution simultaneously, while others own just distribution assets. circuit miles (National Rural Electric Cooperative Association, 2017). They also serve more than half of the land area in the 3.2.1 Ownership Structures Investor-owned utilities serve about 73% of American U.S. They mostly serve areas that IOUs originally declined to serve because expected sales did not justify the cost, given homes and businesses and own about 50% of electric their shareholders’ expectations for rates of return and the distribution circuit miles (National Rural Electric Cooperative required investment. Some cooperatives still serve thinly Association, 2017). The regulated utilities that directly serve populated rural areas with few large loads. Others have seen customers may be part of larger holding companies that their service territories transformed to booming suburbs or include other corporate assets, such as regulated utilities industrial hubs. These entities are also exempt from federal in other states, natural gas assets or totally unrelated and state income tax and do not need to include a return enterprises. Unlike utilities owned by governments or by on equity in the revenue requirement. Unlike municipal
  6. Page 43 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 41 utilities, however, cooperatives cannot issue tax-exempt debt. choose a non-utility retail electricity supplier. However, these Cooperatives do have flexibility to offer other services to their costs should be kept out of the cost of service study and cost customers, such as broadband internet, appliance sales and allocation process and recovered within default power supply repair, and contract billing and collection. Many cooperatives charges or as fees to retail electricity providers. In some operate in areas with limited alternatives, and they tend to restructured states, the regulated utilities still own certain have good relationships with their member customers. An in- types of transmission as a part of the regulated entity, which creasing number of electric cooperatives are building on these is subject to the traditional cost allocation process. In other assets by entering the solar installation and maintenance states, transmission assets have been completely spun off into field. In most states, cooperatives are entirely self-regulated, other entities. In many cases, the regulated utility is allowed with a board being elected by the members. About 16 states to include these transmission costs as an allowed operating regulate cooperatives, often less rigorously than they regulate expense in determining the revenue requirement. IOUs (Deller, Hoyt, Hueth and Sundaram-Stukel, 2009, p. 48). Depending on the mix of assets the regulated utility This is because any “profits” remain with the member-owned owns and the assets and operations of the larger holding cooperative and members can affect decision-making through company, which could span multiple states and even multiple board elections. countries, more complex jurisdictional allocation work may be necessary. The principles for jurisdictional allocation of 3.2.2 Vertically Integrated Versus Restructured Vertically integrated utilities have very different cost generation and transmission, as well as billing and customer service, general plant and A&G expenses, are similar to those used for class cost allocation but do not have to be the same. structures than utilities in states where the electricity Distribution investment costs generally are assigned to the industry has been restructured. Vertically integrated utilities jurisdiction where the facilities are located. Jurisdictional al- provide complete service to customers, including generation, location is typically done as a part of the revenue requirement transmission and distribution service, and their mix of re- process and does not flow into the cost allocation process. sources and cost elements can be extensive. Generation costs may include utility-owned resources, long-term contract 3.2.3 Range of Typical Utility Structures resources, short-term contract resources, storage resources, Between the different ownership models and the mix and spot market purchases and sales. Transmission costs may of assets owned, there are dozens of different utility struc- include resources that are utility-owned; jointly owned with tures across the country. However, certain models are more other utilities; owned by transmission companies purchased common in particular areas: on a short-term or long-term basis; or purchased through • Nearly all IOUs outside of the restructured states are long-term arrangements with an independent system vertically integrated, owning and operating generation, operator (ISO), regional transmission organization (RTO), transmission and distribution systems and billing federal power marketing agency (e.g., the Bonneville Power customers for all of these services. Some municipal and Administration in the Northwest and the Tennessee Valley public power entities are also vertically integrated, as well Authority in the Southeast) or other transmission entity. as a handful of large cooperative utilities. For regulated utilities in restructured states, some • Generation and transmission (G&T) utilities own and of these cost elements will be missing. In most cases, the operate power plants and often transmission lines, selling regulated utility will not own any generation assets. The their services to other utilities (especially distribution regulated entity may serve certain functions with respect to utilities) and sometimes a few large industrial customers. power supply, such as the procurement of default service A large portion of cooperative utilities are served by G&T (also called standard service offer) for customers who do not cooperatives, typically owned by the distribution co-ops.
  7. Page 44 of 276

    42 | ELECTRIC COST ALLOCATION FOR A NEW ERA • Several states have municipal power joint action agencies services from one or more G&T cooperatives, federal that build, buy into or purchase from power plants and agencies, municipal power agencies, merchant generators may own or co-own transmission facilities. Many IOUs or vertically integrated utilities or through an organized provide these services to municipal and cooperative util- market operated by an ISO/RTO. Outside of restructured ities but are predominantly vertically integrated utilities states, most distribution-only utilities are municipals or serving retail customers. cooperatives. The cost allocation issues for these utilities Flow-through restructured utilities operate distribution are similar to those for vertically integrated utilities, systems but do not provide generation services, leaving with the complication that the loads driving the G&T customers to procure those from competitive providers. costs may be different from the loads used in setting the Since generation prices are either set by a retail supplier charges to the distribution utility. in an agreement with a specific customer or determined • REGULATORY ASSISTANCE PROJECT (RAP)® • Some transmission companies solely own and operate by class from the bids of the winning suppliers in util- transmission systems, generally under the rules set by an ity procurements for default service, generation cost RTO. Their charges may be incorporated into the retail allocation is not normally a cost of service study issue for rates of distribution and flow-through utilities. In many these utilities. cases, these transmission companies are subsidiaries Distribution utilities own and operate their distribution of larger holding companies that own other electricity systems but purchase generation and transmission assets.
  8. Page 45 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 43 4. Past, Present and Future of the U.S. Electric System C hapter 3 described the basic elements of the electric system in the United States today, but these Figure 13. Pearl Street Station, first commercial power plant in the United States elements developed out of a 130-year history of twists and turns based on technology, fuels, regulations and even international relations. Understanding the basics of these developments and how and why today’s system was formed is relevant to several important cost allocation issues discussed later in this manual. With respect to cost allocation, four primary results of these changes are worth noting: • A shift from fuel and labor costs to capital costs. • The transition of new generation to non-utility ownership. • Significant levels of behind-the-meter distributed energy resources (DERs), including rooftop solar. • Significant increases in the availability, quality and granularity of electric system data. 4.1 Early Developments Electricity generation and delivery started in the late 19th century with three essentially parallel processes: • Privately owned companies built power plants and delivery systems in cities and near natural generator locations, starting with small areas close to the plants. • Industrial plants built their own generation and connected other customers to use excess capacity. • Source: Wikipedia. Pearl Street Station Municipalities set up their own systems, sometimes starting with the purchase of a small private or industrial over and under city streets. Multiple utilities emerged in facility, to serve the population of the city or town. some cities and competed against one another, which led to Initially, these utilities operated without regulation and the building of duplicative networks of wires in many areas. competed with other fuels, such as peat, coal and wood, These duplicative networks were aesthetically displeasing and which were locally supplied. Municipalities had internal considered by many to be economically wasteful. Relatively processes to set prices, but private utilities were able to charge quickly, however, the natural monopoly characteristics led whatever prices they wished. In this initial period, some cities to the bankruptcy of many utilities or acquisition by a single did impose “franchise” terms on them, charging fees and dominant firm in each city. establishing rules allowing them to run their wires and pipes
  9. Page 46 of 276

    44 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® In New York City, the winning utility, founded by corporate entity — or by municipal entities or cooperatives. Thomas Edison, eventually became the aptly named The boundaries of service between different utilities became Consolidated Edison, or ConEd. Figure 13 depicts Edison’s roughly stable in this time period and reveal the unique first generating station. New York established the first state trends in each utility’s development. economic regulation of electric utilities in 1900, and it Many investor-owned utilities, especially in the Midwest spread widely from there. In New Orleans, the city remains and West, developed service territories that look like octo- the regulator of the IOU; its regulatory activity predated puses, with major urban areas and industrial loads connected the creation of the state commission that regulates all IOUs by tentacles following the paths of transmission lines.17 operating outside of New Orleans. These utilities made business decisions to extend service to 4.2 Rural Electrification and the Federal Power Act In the early period, regulatory authority over electric particular geographic areas where they believed the potential sales revenues would justify the cost of investment in transmission or distribution and still cover the additional costs of generation and customer service necessary to serve the load.18 utilities was primarily exercised by states. In 1935, Congress In each case, the utility expected that the sale of electricity passed the Federal Power Act, which vastly expanded the would generate enough revenue to justify this expenditure. jurisdiction of the Federal Power Commission (now FERC) to Figure 14 on the next page shows the service territories cover interstate electricity transmission and wholesale sales of the Texas investor-owned utilities, illustrating these of electricity. However, most economic regulation remained patterns (Association of Electric Companies of Texas Inc., under the jurisdiction of state utility commissions, including 2019). Similar patterns are evident in the service territory authority over retail prices. maps of Minnesota, Delaware, Ohio, Oregon, Washington By the 1930s, most urban and suburban areas had access and Virginia. IOUs and municipal utilities generally serve to electric service, but most rural areas did not. The Rural densely populated areas, while cooperatives and public power Electrification Act passed Congress in 1936, creating the districts, typically created and incentivized under the Rural Rural Electrification Administration to finance and assist the Electrification Act, serve less dense areas. extension of service to rural areas through electric coopera- In some states, IOUs do serve some sparsely populated tives, the Tennessee Valley Authority, various forms of public areas. This is often the result of a franchise grant by a munic- power districts and some state-sponsored utilities. The initial ipality or a state mandate for service throughout an identified financing included significant federal support in the form area to avoid islands where service is unavailable. The cost of of grants, technical assistance and very low-interest loans. this rural service is, to the utility, a price it must pay for access A handful of states, including New York, North Carolina to the more densely populated area for a viable business, and Oklahoma, set up their own state power authorities to although ratepayers typically bear the higher costs of service. develop hydro facilities16 and provide low-cost energy for economic development and other local priorities. 4.3 Vertically Integrated Utilities Dominate By 1950, 90% of rural America was electrified, and access to electric service became nearly universal across the United States. Nearly all electric service was provided by vertically integrated utilities — which owned or contracted for power plants, transmission and distribution within the same 16 Some of these state entities eventually assumed ownership of other types of generation. 17 In some states, such as Massachusetts, most of Maryland, Rhode Island and New Jersey, the IOUs serve large contiguous areas, regardless of density, due to historical and legal conditions in each state. In essence, the utilities incurred an obligation to serve less-developed areas as a price of obtaining authority to serve more densely populated areas. 18 In some cases, the IOU picked up dispersed service territory during the process of acquiring the assets of other power producers or to obtain state or local licenses for generation or transmission facilities.
  10. Page 47 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 45 Figure 14. Investor-owned electric utility service territories in Texas AEP Texas Central Co. AEP Texas North Co. CenterPoint Energy El Paso Electric Co. Entergy Texas Oncor Southwestern Electric Power Co. Texas-New Mexico Power Co. Xcel Energy Source: Association of Electric Companies of Texas Inc. (2019). Electricity 101 A cost analyst may need to examine these costs carefully to which was later repealed. In addition, generation of electricity avoid shifting them to specific customer classes and to spread with natural gas was to be prohibited at existing plants by 1990, these costs systemwide. with an exception for certain combined heat and power (CHP) 4.4 From the Oil Crisis to Restructuring facilities (Gordon, 1979). This law accelerated a trend toward the construction of large capital-intensive nuclear and coal power plants across the country in order to get away from the From the 1950s to the early 1970s, electric sales skyrock- use of oil and natural gas for electricity. The confluence of all eted due to a wide range of new electric end uses, and prices these trends, including high oil prices and expensive capital- were relatively stable. However, the cost structure of the intensive plants entering the rate base, led to major increases utility industry changed drastically after the 1974 oil crisis. in electricity prices, as depicted in Figure 15 on the next page Demand fell rapidly, particularly in locations where oil was using U.S. Energy Information Administration data (2019). used to generate electricity, in response to large price increases Congress also passed PURPA in 1978, which included and fuel shortages. Natural gas prices, which had been partly provisions intended to open up competition in the provision regulated, were gradually deregulated over the next decade, of electricity and to reform state rate-making practices. On but natural gas was thought to be in short supply and available the competition side, PURPA required electric utilities to only for certain uses. No new baseload power plants running purchase power from independent producers at long-term more than 1,500 hours a year could be run on oil or natural prices based on avoided costs. With regard to state rate- gas under the Powerplant and Industrial Fuel Use Act of 1978, making practices, PURPA also required state commissions