Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Files3

Search terms highlighted
Eversource rate increase is on 6 pages across 2 files of the text below, highlighted. Go to the first matchClear highlighting
5 pages match
Words on different pages
  1. Page 6 of 276

    4 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® 10. Transmission in Embedded Cost of Service Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 10.1 Subfunctionalizing Transmission. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 10.2 Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 10.3 Allocation Factors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 10.4 Summary of Transmission Allocation Methods and Illustrative Examples . . . . . . . . . . . . . . . . . . . . . 140 11. Distribution in Embedded Cost of Service Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 11.1 Subfunctionalizing Distribution Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 11.2 Distribution Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 11.3 Distribution Demand Allocators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 11.3.1 Primary Distribution Allocators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 11.3.2 Relationship Between Line Losses and Conductor Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . 153 11.3.3 Secondary Distribution Allocators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 11.3.4 Distribution Operations and Maintenance Allocators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 11.3.5 Multifamily Housing and Distribution Allocation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 11.3.6 Direct Assignment of Distribution Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 11.4 Allocation Factors for Service Drops. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 11.5 Classification and Allocation for Advanced Metering and Smart Grid Costs . . . . . . . . . . . . . . . . . . . 156 11.6 Summary of Distribution Classification and Allocation Methods and Illustrative Examples. . . . . . 158 11.6.1 Illustrative Methods and Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 12. Billing and Customer Service in Embedded Cost of Service Studies. . . . . . . . . . . . . . . 162 12.1 Billing and Meter Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 12.2 Uncollectible Accounts Expenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 12.3 Customer Service and Assistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 12.4 Sales and Marketing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 13. Administrative and General Costs in Embedded Cost of Service Studies. . . . . . . . . . . 165 13.1 Operations and Maintenance Costs in Overhead Accounts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 13.2 Labor-Related Overhead Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
  2. Page 7 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA 13.3 Plant-Related Overhead. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 13.4 Regulatory Commission Expenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 13.5 Administrative and Executive Overhead. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 13.6 Advertising and Donations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 14. Other Resources and Public Policy Programs in Embedded Cost of Service Studies. . . 167 14.1 Energy Efficiency Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 14.2 Demand Response Program and Equipment Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 14.3 Treatment of Discounts and Subsidies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 15. Revenues and Offsets in Embedded Cost of Service Studies. . . . . . . . . . . . . . . . . . . . . . . 171 15.1 Off-System Sales Revenues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 15.2 Customer Advances and Contributions in Aid of Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 15.3 Other Revenues and Miscellaneous Offsets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 16. Differential Treatment of New Resources and New Loads . . . . . . . . . . . . . . . . . . . . . . . . 173 16.1 Identifying a Role for Differential Treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 16.2 Illustrative and Actual Examples of Differential Treatment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 16.2.1 Real-World Examples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 17. Future of Embedded Cost Allocation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 Works Cited in Part III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Part IV: Marginal Cost of Service Studies 18. Theory of Marginal Cost Allocation and Pricing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 18.1 Development of Marginal Cost of Service Studies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 18.2 Marginal Costs in an Oversized System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 18.3 Impact of New Technology on Marginal Cost Analysis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 18.3.1 Renewable Energy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 18.3.2 Other New Technologies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 18.4 Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 | 5
  3. Page 8 of 276

    6 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® 19. Generation in Marginal Cost of Service Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 19.1 Long-Run Marginal Cost of Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 19.2 Short-Run Marginal Energy Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 19.3 Short-Run Marginal Generation Capacity Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 20. Transmission and Shared Distribution in Marginal Cost of Service Studies. . . . . . . . . 202 20.1 Marginal Transmission Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 20.2 Marginal Shared Distribution Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 21. Customer Connection and Service in Marginal Cost of Service Studies. . . . . . . . . . . . 207 21.1 Traditional Computation Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 21.2 Smart Meter Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 21.3 Operations and Maintenance Expenses for Customer Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . 209 21.4 Billing and Customer Service Expenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 21.5 Illustrative Marginal Customer Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 22. Administrative and General Costs in Marginal Cost of Service Studies. . . . . . . . . . . . . 214 23. Public Policy Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 24. Reconciling Marginal Costs to Embedded Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 25. Cutting-Edge Marginal Cost Approaches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 25.1 Total Service Long-Run Incremental Cost. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 25.1.1 Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 25.1.2 Transmission. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 25.1.3 Shared Distribution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 25.1.4 Customer Connection, Billing and Service Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 25.2 Hourly Marginal Cost Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 25.2.1 Energy and Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 25.2.2 Transmission and Shared Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
  4. Page 9 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA 26. Summary of Recommendations for Marginal Cost of Service Studies . . . . . . . . . . . . . 224 26.1 Improving Marginal Cost Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 26.2 Moving Toward Broader Reform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 Works Cited in Part IV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 Part V: After the Cost of Service Study 27. Using Study Results to Allocate the Revenue Requirement. . . . . . . . . . . . . . . . . . . . . . . 230 27.1 Role of the Regulator Versus Role of the Analyst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 27.2 Presenting Embedded Cost of Service Study Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 27.3 Presenting Marginal Cost of Service Study Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 27.4 Gradualism and Non-Cost Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 28. Relationship Between Cost Allocation and Rate Design . . . . . . . . . . . . . . . . . . . . . . . . . . 240 28.1 Class Impacts Versus Individual Customer Impacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 28.2 Incorporation of Cost Allocation Information in Rate Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 28.3 Other Considerations in Rate Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 Works Cited in Part V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 Appendix A: FERC Uniform System of Accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 Appendix B: Combustion Turbine Costs Using a Real Economic Carrying Charge Rate. . . . 250 Appendix C: Inconsistent Calculation of Kilowatts in Marginal Cost Studies. . . . . . . . . . . . 252 Appendix D: Transmission and Distribution Replacement Costs as Marginal Costs. . . . . . 253 Appendix E: Undervaluation of Long-Run Avoided Generation Costs in the NERA Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 | 7
  5. Page 10 of 276

    8 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Acknowledgments Editorial assistance was provided by Ruth Hare, Camille Kadoch, Donna Brutkoski and Tim Simard. The authors wish to express their appreciation to the following people — many of whom are former state utility commissioners — for providing helpful insights into early drafts of this manual: Ron Binz, Public Policy Consulting John Colgan, Colgan Consulting Mike Florio, Gridworks Jeff Goltz, Cascadia Law Group Renz Jennings Douglas Jester, 5 Lakes Energy Carl Linvill, RAP David Littell, RAP Karl Rábago, Pace Energy and Climate Center Rich Sedano, RAP John Shenot, RAP Frederick Weston, RAP Melissa Whited, Synapse Energy Economics Tim Woolf, Synapse Energy Economics The authors also thank Jonathan Wallach of Resource Insight Inc. for his contribution to this effort. In preparing this manual, the authors drew inspiration from the work and ideas of many others in addition to those discussed within. They include: Peter Bradford Eugene Coyle Phil Jones Sharon Nelson Tom Power George Sterzinger John Stutz That said, responsibility for the information and views set out in this work lies entirely with the authors.
  6. Page 11 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA About the Authors Jim Lazar, senior advisor with the Regulatory Assistance Project, is an economist who studied economics and energy at Western Washington University and the University of Washington. He has maintained a consulting practice in utility regulation and pricing and has made more than 100 appearances as an expert witness in rate proceedings in many different jurisdictions. His first utility rate proceeding was in 1974. As a RAP senior advisor, he has advised utility regulators across the United States and in Europe, India, Asia, Africa and South America. He is a former member of the U.S. Department of Energy Electricity Advisory Committee. Mr. Lazar has published more than 20 reference handbooks and topical papers on utility regulation and planning. Paul Chernick, president of Resource Insight Inc., studied technology and policy at the Massachusetts Institute of Technology. He has advised clients on a wide range of issues, including restructuring policy; estimation of stranded costs; market price forecasts; market valuation of generation resources and divestiture of generation assets; planning and rate-making for central supply, energy efficiency, renewable and distributed resources, and least-cost compliance with environmental regulations; cost allocation and rate design; transmission and distribution planning; and valuation of environmental externalities. Mr. Chernick has testified in more than 300 regulatory and judicial proceedings. He began his career in 1977 with the Massachusetts attorney general’s office. William Marcus, principal of MCPM Economics — a successor company to JBS Energy Inc., where he worked for 32 years — studied economics at Harvard University and the University of Toronto. He began his energy career with the California Energy Commission in 1978. Mr. Marcus has more than 40 years of experience analyzing utility resource plans, costs and rates. He has prepared cost and rate studies for numerous clients and has testified as an expert witness in more than 40 jurisdictions. Taken together, the three authors have more than 120 years of experience in cost allocation and rate design issues. They have been qualified and testified as expert witnesses before 43 state utility regulatory agencies, eight Canadian provinces and many other local, state and federal regulatory bodies. About the Editor Mark LeBel, associate at the Regulatory Assistance Project, has more than a decade of experience working on the overlapping economics and law of energy and environmental policy in the United States. As a member of RAP’s U.S. team, he focuses on rate design and regulatory reform, including compensation for distributed energy resources, the evolution of the electricity system and beneficial electrification. | 9
  7. Page 12 of 276

    10 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Figures Figure 1. Simplified rate-making process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Figure 2. Traditional embedded cost of service study flowchart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Figure 3. Increase in US wind and solar generation from 2008 to 2018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Figure 4. Modern embedded cost of service study flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 5. Sankey diagram for traditional embedded cost of service study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 6. Sankey diagram for modern embedded cost of service study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 7. Illustrative traditional electric system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Figure 8. Illustrative modern electric system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Figure 9. Underground distribution circuit with radial secondary lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 10. Detail of underground distribution circuit with networked secondary lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 11. Secondary distribution pole layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 12. Electric delivery system line losses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 13. Pearl Street Station, first commercial power plant in the United States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Figure 14. Investor-owned electric utility service territories in Texas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Figure 15. US average retail residential electricity prices through 2018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Figure 16. Permissible overload for varying periods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Figure 17. Summer peak day load from 10 residential customers on one line transformer. . . . . . . . . . . . . . . . . . . . . . . . . 59 Figure 18. Traditional embedded cost of service study flowchart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Figure 19. Modern embedded cost of service study flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Figure 20. Sankey diagram for legacy embedded cost of service study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Figure 21. Sankey diagram for modern embedded cost of service study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Figure 22. Customer behavior in Sacramento Municipal Utility District pricing pilot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Figure 23. Evolution of system load in Hawaii on typical June weekday . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Figure 24. Illustrative Texas wind and solar resource compared with load shape. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Figure 25. Forecasts of electric vehicle share of sales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Figure 26. Estimated grid integration costs for electric vehicles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Figure 27. US solar photovoltaic installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Figure 28. Substation backfeeding during high solar hours. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Figure 29. Projections for US coal generating capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
  8. Page 13 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 11 Figure 30. ERCOT load and real-time prices in 2017. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Figure 31. Capacity revenue percentage in relation to capacity factor in PJM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Figure 32. Cost of combustion turbine plant in service in 2011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Figure 33. Simplified generation dispatch duration illustrative example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Figure 34. Illustrative customer class load in each hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Figure 35. Illustration of decomposition approach to allocating resource mix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Figure 36. Transmission east of San Francisco Bay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Figure 37. Transmission system with uniformly distributed demand and generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Figure 38. Transmission system with remote and centralized generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Figure 39. Stub pole used to guy a primary pole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Figure 40. San Diego Gas & Electric circuit peaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Figure 41. Month and hour of Delmarva Power & Light substation peaks in 2014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Figure 42. Typical utility estimates of diversity in residential loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Figure 43. US load growth by customer class since 1990. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Figure 44. Estimated revenue and cost from serving additional electric vehicle load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Figure 45. Daily dispatch for illustrative hourly allocation example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 Figure 46. Class loads for illustrative hourly allocation example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Figure 47. Comparison of temporal distributions for combustion turbine cost recovery . . . . . . . . . . . . . . . . . . . . . . . . . . 251
  9. Page 14 of 276

    12 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Tables Table 1. Types of meters and percentage of customers with each in 2017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table 2. Cost drivers for power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Table 3. Cost drivers for transmission. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Table 4. Cost drivers for distribution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Table 5. Illustrative load research data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Table 6. Simple allocation factors derived from illustrative load research data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Table 7. Composite allocation factors derived from illustrative load research data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Table 8. 1992 NARUC cost allocation manual classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Table 9. Results of two illustrative embedded cost of service study approaches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Table 10. Illustrative allocation factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Table 11. Illustrative marginal cost results by element. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Table 12. Cost components of conventional generation, 2018 midpoint estimates. . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Table 13. Energy portion of 2017 net revenue for New York ISO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Table 14. Equivalent peaker method analysis using replacement cost estimates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Table 15. Equivalent peaker method analysis using 2017 gross plant in service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Table 16. Equivalent peaker method classification of nonfuel operations and maintenance costs . . . . . . . . . . . . . . . 117 Table 17. Class share of each generation type under probability-of-dispatch allocation. . . . . . . . . . . . . . . . . . . . . . . . 120 Table 18. Allocation of 400 MWs excess capacity to reflect load risk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Table 19. Attributes of generation classification options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Table 20. Illustrative example of energy-classified cost per MWh by time of use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Table 21. Illustrative example of time-of-use allocation of energy-classified costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Table 22. Attributes of generation demand allocation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Table 23. Summary of conceptual generation classification by technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Table 24. Summary of generation allocation approaches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Table 25. Illustrative annual generation data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Table 26. Allocation of generation capacity costs by traditional methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Table 27. Modern hourly allocation of generation capacity costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Table 28. Summary of transmission classification and allocation approaches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Table 29. Illustrative allocation of transmission costs by different methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
  10. Page 15 of 276

    REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 13 Table 30. Residential shared transformer example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Table 31. Smart grid cost classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Table 32. Summary of distribution allocation approaches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 Table 33. Illustrative allocation of distribution substation costs by different methods . . . . . . . . . . . . . . . . . . . . . . . . . 159 Table 34. Illustrative allocation of primary distribution circuit costs by different methods. . . . . . . . . . . . . . . . . . . . . . 160 Table 35. Illustrative allocation of distribution line transformer costs by different methods . . . . . . . . . . . . . . . . . . . . 160 Table 36. Illustrative allocation of customer-related costs by different methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Table 37. Illustrative cost study with differential treatment of new resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 Table 38. Bonneville Power Administration rate summary, October 2017 to September 2019. . . . . . . . . . . . . . . . . . . 177 Table 39. Hourly class load share and resource output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 Table 40. Class shares of resource cost responsibilities and load. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 Table 41. Illustrative example of allocating marginal distribution demand costs by two methods. . . . . . . . . . . . . . . . 192 Table 42. Illustrative example of new-customer-only method for marginal customer costs. . . . . . . . . . . . . . . . . . . . . 212 Table 43. Illustrative example of rental method for marginal customer costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 Table 44. Illustrative comparison of rental versus new-customer-only method for overall distribution costs. . . . . . 213 Table 45. Computing class rate of return in an embedded cost study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 Table 46. Illustrative marginal cost results by element. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 Table 47. Illustrative load research data for marginal cost of service study . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 Table 48. Illustrative marginal cost revenue requirement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 Table 49. EPMC adjustment where revenue requirement less than marginal cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 Table 50. EPMC adjustment where revenue requirement more than marginal cost. . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 Table 51. Illustrative functionalized equal percentage of marginal cost results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 Table 52. Total EPMC results with lower marginal generation costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 Table 53. Functionalized EPMC example with lower marginal generation costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 Table 54. Residential embedded cost responsibility across four scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 Table 55. Use of inverse elasticity rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 Table 56. Consideration of multiple cost of service studies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
1 page match

As listed on the current system

Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Melissa Whited [26-05-10]

This filing on the current system (opens in a new tab)