Prefiled testimony
Witness: Melissa Whited
Files3
Synapse - Eversource COS and Rate Design Testimony Final.pdf
PDF · 829 KB · 48 pagesText searchable
Download Synapse - Eversource COS and Rate Design Testimony Final.pdfRead the text of Synapse - Eversource COS and Rate Design Testimony Final.pdf
MW-2- Synapse Attachment.pdf
PDF · 4.6 MB · 276 pagesText searchable
Download MW-2- Synapse Attachment.pdfRead the text of MW-2- Synapse Attachment.pdf
MW-1 - Synapse Attachment.pdf
PDF · 734 KB · 13 pagesText searchable
Download MW-1 - Synapse Attachment.pdfRead the text of MW-1 - Synapse Attachment.pdf
Page 62 of 276
60 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Table 4. Cost drivers for distribution Type Purpose Investmentrelated costs Maintenance costs Substations Power at all hours; capacity for high-load hours High Low Primary circuits Power at all hours; capacity for high-load hours High Low Line transformers Power at all hours; capacity for localized high-load hours Medium Low Secondary service lines Power at all hours; capacity for localized high-load hours Medium Low Meters: Traditional Measuring usage Low Low Meters: Advanced Multiple functions Medium Low average embedded cost of service, a circumstance that results different types of equipment. Most of the distinctions among in benefits to the utility and other ratepayers. types of equipment represent alternative or complementary The final components in the distribution system are methods for providing the same service. For example, meters, typically installed for all residential and general various primary distribution feeders operate at 4 kV, 13 kV service customers but not for very predictable loads like or 25 kV and may be overhead or underground construction, traffic signals or streetlights. How to classify the cost is a depending on load density, age of the equipment, local matter of debate. On one hand, a meter is needed because governmental requirements and other considerations. usage levels vary from customer to customer and month to Although the power flowing from generation to a customer month, a theoretically usage-related cost. But on the other served at 25 kV may not flow over any 4-kV feeder, the 4-kV hand, one meter is needed for every metered customer, and feeders serve the same function as the 25-kV feeders and (in meter costs do not typically vary from customer to customer places in which they are adequate) at lower cost.33 Serving within a class. In addition, smart meters entail both higher some customers at 4 kV and spreading the feeder costs among direct investment costs and back office investments but all distribution customers does not increase costs allocated provide generation, transmission and distribution system to the customers served directly from the 25-kV feeders; benefits by allowing more precise measurement and converting the 4-kV feeders to a higher voltage would likely control of local loads and more accurate assignment of increase costs to all distribution customers, including those peaking capacity requirements. Lastly, the cost of current now served at 25 kV. In this situation, all the feeders should be transformers and potential transformers necessary to meter treated as serving a single function, and all their costs should large customers should be included as part of their metering be allocated in the same manner. costs — an issue common between embedded and marginal Similarly, most customers served by single-phase primary cost methods.32 Table 4 summarizes cost drivers in the distribution are served with that configuration because it is distribution system. cheaper than extending three-phase primary distribution, 5.1.4 Incremental and Complementary Investments which they do not require because of the nature of their loads. Good economic analysis should distinguish properly between complementary or alternative investments, which substitute for one another, and incremental investments, which add costs to the system. Customers receive service at different voltages and with 32 Current transformers reduce the amperage so a meter can read it. Potential transformers reduce the voltage for meter reading (Flex-Core, n.d.). 33 Conversely, the 4-kV supply to some customers is from transformers fed directly from transmission without using the 25-kV system.Page 63 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® On the other hand, some distinctions in voltage level ELECTRIC COST ALLOCATION FOR A NEW ERA | 61 to the total load that needs to be served by the line or the represent incremental investment: happenstance that the subtransmission line is already in • Most customers served at distribution voltages cannot take place. If it is less expensive to serve customers with the lower service directly from the transmission system. Even if a voltage, it would be inequitable to charge them more for transmission line runs right past a supermarket or housing being served at that voltage. • development, the utility must run a feeder from a distri- Similarly, distribution poles carrying only secondary bution substation to serve those customers. Distribution lines are less expensive than poles carrying primary lines. If in its broadest sense is thus principally an incremental a customer served by a secondary-only pole had to be served service, rather than an alternative to transmission, needed at primary voltage instead, the primary pole would be more by and provided to some customers but not all.34 expensive, and that higher cost would almost certainly be al- Similarly, most customers who take service at secondary located to all distribution customers. Secondary poles (unlike voltage have a primary line running by or to their prem- line transformers and most secondary lines) are lower-cost ises yet cannot take service directly at primary voltage.35 alternatives to some primary poles.37 The line transformers are incremental equipment that would not be necessary if the customers could take service at primary voltage.36 These incremental costs should be functionalized so that 5.2 Determining Customer Classes In addition to administrative simplicity, the purpose of they are allocated to the loads that cause them to be incurred, separating customers into broad classes flows from the idea while each group of complementary costs (such as various that different types of customers are responsible for different distribution voltages) generally should be treated as a single types of costs, and thus it is fairer and more efficient to charge function and recovered from all customers who use any of the them separate rates. One set of rates for each customer class, alternative facilities. based on separate cost characteristics, is the key feature of In other situations, distinguishing between incremental postage stamp pricing for electric utilities. As a result, it is and complementary costs can be more complicated. Exam- very important to determine appropriate customer classes ples include the treatment of transmission equipment at with different cost characteristics at the outset of a cost of different voltages and the treatment of secondary poles. Many service study. The number of classes will vary from utility to embedded cost of service studies treat subtransmission as utility and may vary depending on the costing methodology an incremental cost separate from transmission and charge being used. In addition to equitable cost allocation, different more for delivery to customer classes served directly from rate structures are often used for different rate classes. For the subtransmission system or from substations fed by the example, residential customer classes generally do not have subtransmission system. For the most part, utilities use lower demand charges today, but most large industrial classes do. transmission voltage where it is less expensive than higher This means that decisions regarding the number and type voltages, either due to the lower cost of construction relative of customer classes can also have rate design implications, 34 In some cases, a distribution substation and feeder can bring service to customers that would otherwise be served by an extension of the transmission system at higher cost. Identifying and accounting for that limited complementary service is probably not warranted in most embedded cost of service study applications. 36 Although most networked secondary conductors parallel primary lines and are incremental to the primary system, a limited number of secondary conductors extending beyond the primary lines are complementary, because they avoid the need to extend primary lines. 35 Another way of looking at this relationship is that secondary customers are those for whom providing service at secondary has a lower total cost than providing service at primary. Sharing utility-owned transformer capacity is less expensive than having each customer build its own transformer. See Chapter 11 for a discussion of primary and secondary distribution and their allocation. 37 Similarly, a portion of the secondary lines replaces primary lines. If the customers that can be served with secondary poles required primary service, the utility would need to extend the primary lines rather than secondary lines. Hence, a portion of the secondary lines is also complementary to the primary system, rather than additive.Page 64 of 276
62 | ELECTRIC COST ALLOCATION FOR A NEW ERA although this is not necessarily permanent. REGULATORY ASSISTANCE PROJECT (RAP)® A word of caution is appropriate here. With respect to Most utilities distinguish among residential customers, technology-driven class characteristics such as electric space small commercial customers, large commercial customers, heat, water heat, vehicles or solar installations, singling out industrial customers and street lighting customers. The customers based on technology adoption has serious practical commercial and industrial classes often are collectively termed and theoretical downsides. Furthermore, addressing one general service rate classes. In many cases, general service cus- minor cost distinction is likely not fair or efficient if several tomers are categorized by voltage levels. Customers served at other major cost distinctions, such as those listed above, are primary distribution voltage generally do not use, and should not addressed. It is wiser to consider multiple customer and not be allocated, costs of secondary distribution facilities, and service characteristics simultaneously to create technology- customers served at transmission voltage generally do not use, neutral subclasses for both cost allocation and rate design and should not be allocated, costs of distribution facilities. purposes. Many utilities also separate general service classes with even greater granularity than using simple voltage criteria. One area where utility practices can vary significantly is To begin, electric space heating customers are likely to have different load characteristics from the nonheating customers, with significantly more usage and a different whether there is more than one residential class or, alterna- daily load shape in the winter. For a winter-peaking system, tively, multiple residential subclasses. Some utilities separate this could mean that electric heating customers should out residential customers based on a measure of size, such be allocated proportionately more costs. Conversely, in a as peak demand or energy use. This can be significant in summer-peaking system, electric heating customers should be jurisdictions that categorize farms or large master-metered allocated proportionately fewer overall costs. However, this multifamily buildings as residential in a formal sense. Some issue, which is essentially a question of a potential intraclass jurisdictions also create separate classes based on the usage of cross-subsidy between types of residential customers, can specific technologies like electric resistance heating. In some also be addressed through changes to rate design. Seasonally jurisdictions, low-income discount customers are treated as a differentiated rates, if based appropriately on cost causation, separate rate class. can achieve the same distributional impact as separate rate The creation of multiple residential classes or subclasses classes for heating and nonheating customers while bringing is typically justified on cost grounds. There are inarguably additional benefits from the improved efficiency of pricing. many cost distinctions among different types of residential The creation of an electric heating rate class can have customers, and simple postage stamp cost allocation and other implications. In regions where electric heating custom- rate structures may not capture many of those distinctions. ers are disproportionately low-income, this decision also has Regulators and utilities have long analyzed the causes of such significant equity implications. There can also be environ- differences, which vary widely across the country. Some of mental repercussions to this choice. Concerns would arise, the distinctions are based on technology (or, more accurately, for example, if electric heating rates promote use of gas and as a proxy for the load impacts of certain technologies), such coal in power plants to replace direct burning of gas on-site as electric space heating, electric water heating, solar or other for heating, which historically was often more efficient on a distributed generation and even electric vehicles. Other total energy basis. Recent developments in efficient electric distinctions are based on the characteristics of service. Those heating, particularly air and ground source heat pumps, may with relatively large impacts on cost allocation include: have switched the valence of these questions. In certain areas, • Single family versus multifamily. higher-income customers may be disproportionately adopt- • Urban (multiple customers per transformer) versus rural ing efficient electric heating. And the new electric technolo- (one customer per transformer). gies may now be significantly cleaner and more efficient than Overhead service versus underground service. on-site combustion of natural gas, particularly if powered by •Page 65 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | zero emissions electric resources. A seasonal and time-varying for single-family and multifamily residential customers. cost study and time-varying rates may enable appropriate cost There are many reasons to believe that the cost of serving recovery without need for a separate class. multifamily buildings is substantially lower than serving Several states have considered creating a separate rate 63 single-family homes on average: class for customers with solar PV systems. Because solar • Shared service drops. customers may have different usage patterns than other • Increased diversity of load for line transformers and sec- customers, this is reasonable to investigate. However, it is not clear that there is a significant cross-subsidy to address, ondary distribution lines, enabling more efficient sizing. • Reduced cost of distribution per customer, since no particularly at low levels of PV adoption. Current rate design distribution lines are required between customers in the practices for solar customers in many jurisdictions — such building.38 as net metering using flat volumetric rates, monthly netting • Reduced coincidence with both summer and winter peak and crediting at the retail rate — are fairly simple. These loads because common walls reduce space conditioning rate design practices could be improved significantly over use relative to single-family units of the same square time and integrated with broader rate design reforms. For footage, and because lighting and baseload appliances such example, a time-varying cost study would allow the creation as refrigerators and water heaters (if electric) are a larger of more granular time-varying rates so that solar customers percentage of loads for units with fewer square feet. pay an appropriate price for power received during nonsolar • Reduced need for secondary distribution lines in cases hours and are credited with an appropriate price for power where the multifamily building can be served directly delivered to the distribution system during solar hours. This from the transformer. would include changes to netting periods, which would reveal • Reduced summer peak coincidence if space cooling is more information about how a solar customer actually uses provided through a separate commercial account for the the electric system. building, rather than as part of the individual residential accounts. In terms of rate classes for specific technologies, some utilities separate out customers with electric water heating as • Reduced costs of manual meter reading, where still a proxy for a flat load shape and the potential for load control. applicable. In the future, some utilities may seek to make electric vehicle There may be countervailing considerations in some adoption a separate rate class as a substantially controllable service territories, such as if multifamily buildings are served load with distinct usage characteristics. However, these by more expensive underground service and single-family technologies may not need consideration as a separate rate buildings are served with cheaper overhead lines. A similar class, particularly given efforts to improve the cost causation set of considerations may cause some utilities to disaggregate basis of rate design more generally. Again, time-varying rates customers by geography, such as those residing inside and will appropriately charge customers with peak-oriented loads outside city limits.39 Customers in deeply rural areas tend and appropriately benefit customers with loads concentrated to be more expensive to serve, since they typically are too in low-cost hours or controlled into those hours. far from their neighbors to share transformers, require a Some utilities have implemented separate rate classes 38 This distinction is important where some distribution costs are classified as customer-related. In those situations, each multifamily building (rather than each meter) should be treated as one customer, as would a single commercial customer of the same size and load. 39 For example, Seattle City Light, a municipal utility, has two rate schedules for most commercial and industrial classes within the city: one for the highly networked higher-cost underground system in the urban core, long run of primary line along the public way, and generally and another for the balance of the city, plus separate higher rates for the adjacent cities and towns where it provides service. Compare Schedules MDC, MDD, MDS and MDT at Seattle City Light (n.d.). The city of Austin, Texas, also applies different rates to customers outside the city limits (Austin Energy, 2017). In many places, cities impose franchise fees or municipal taxes that make customer bills inside cities higher than those outside cities, even though the cost data may suggest the opposite is more equitable.Page 66 of 276
64 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® have higher unit costs related to lower load per mile of cross-subsidies within customer classes in a relatively distribution line.40 straightforward manner that also provides additional effi- Analysts may want to employ a simple standard for ciency benefits. In principle, perfectly designed time- and deciding when to divide a subclass for analytical purposes, location-varying pricing for all electric system components based on whether the groups are large enough and distinct and externalities, applied identically to all customers, could enough to form a separate class or subclass. One such eliminate the need for customer classes and cost allocation guideline might be that, if more than 5% of customers or entirely while providing perfectly efficient price signals. This 5% of sales within a class have distinct cost characteristics, is unlikely to be the case for the foreseeable future but illus- differentiation is worth considering. If fewer than that, trates the conceptual point that an efficient improvement to although the per-customer cost shifts may be significant, the rate design may be a strictly preferred option compared with overall impact on other customers will likely be immaterial. the creation of a new rate class. For example, certain types of If 2% of the load in a class is paying 20% too much or too customers could be put on technology-neutral time-varying little, for example, other customers’ bills will change only rates on an opt-out or mandatory basis, such as customers 0.4%. But if 15% of the load is 20% more or less expensive, with storage, electric vehicles or distributed generation. the impact on other users rises to 3%. The trajectory of these impacts over time can also be relevant. Although improved distributional equity from additional rate classes is a laudable goal, and indeed advances the prima- 5.3 Load Research and Data Collection Any cost of service study, as well as rate design, load ry goal of cost allocation, there are countervailing consider- forecasting, system planning and other utility functions, ations that may dictate keeping the number of rate classes on depends heavily on load research data. Cost allocation, in the smaller side. First, there are administrative and substan- particular, requires reasonably accurate estimates for each tive concerns around adding rate classes, both in litigation at class or group distinguished in the analysis, the number state regulatory commissions and in real-world implementa- of customers, their energy usage (annual, monthly and tion. Some potential distinctions among customers may be sometimes more granular time periods), their kW demand at difficult to implement because they involve subjective and various times and under various conditions, and sometimes potentially controversial determinations by on-the-ground more technical measures such as power factor. The key utility personnel. In creating new distinctions, regulators, principle is that there is diversity among customers in each utilities and stakeholders must all have confidence that there class, meaning the consumption characteristics for the are true cost differentials between the customer types and group are less erratic than those of any individual customer. that there will be little controversy in the application of the Load research is the process of estimating that diversity. differentials. Some analysts object to customer classes based At the very least, these data must be available by class on adoption of particular end uses, although this may serve as across the entire system. For some applications, these data a proxy for significantly different usage profiles. Furthermore, are useful and even essential at a more granular level, such as some utilities and parties in a rate case may propose rate for each substation, feeder or even customer. Ideally, the cost classes that effectively allow undue discrimination. If the of service study would be able to draw on information about proper data aren’t available to scrutinize such claims, either the hourly energy usage by class, as well as the contribution publicly or for parties in a rate case, then this may allow an of each class to the sum of the customer contributions to end-run around one of the significant motivations for postage the maximum loads across the line transformers serving the stamp pricing: preventing price discrimination. Lastly, as described above for electric heating and solar PV customers, rate design changes can also address certain 40 These factors may be offset by the utility’s policy for charging new customers for extending the distribution system, as discussed in Section 11.2Page 67 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 65 class, the feeders serving the class, the substations serving are usually publicly available for regulated utilities. Neither the class and so on. Modern AMI and advanced distribution sampled load nor proxy load will provide the precision of monitoring systems, if properly configured, can provide those comprehensive interval metering, but they can provide data. Some utilities now routinely collect interval load data at reasonable estimates of the contribution of the group to each level of the system, while others are starting to acquire demand at each hour, enabling development of cutting-edge those capabilities. techniques such as time-specific allocation methods. The data needed for different cost allocation frameworks Different elements of load research data are relevant in and methods can vary greatly, and it is difficult to generalize the creation of allocation factors for different parts of the because of this. But at a high level, embedded cost techniques system. For example: rely on one year of data or the equivalent forecast for one • Most residential customers may be served through a year. For many inputs, marginal cost techniques often rely transformer shared with other residential, commercial on multiple years of data in order to estimate how costs are and street lighting customers, so the allocation of changing with respect to different factors over time. Different transformer costs to each class should ideally be derived data may be needed for each step of the process, starting from their contribution to the high-load periods of each from the functionalization of costs down to the creation such transformer. of allocation factors, or allocators, to split up the costs to • customer classes. Some residential customers are served from feeders that peak in the morning and others from feeders that peak in Where the utility’s metering and data collection do not midday or the evening; some of those feeders may reach directly provide comprehensive load data for all customers their maximum load or stress in the summer and others and system components, two options are available. The first in the winter. The sum of the class contribution to the and generally preferable option is sampling. Most investor- various peak hours of the various feeders determines the owned and larger consumer-owned utilities install interval share of peak-related costs allocated to the class for this meters specifically for load research purposes on a sample portion of the distribution system. of customers in each class that does not have widespread • At the bulk power level, all customers share the gener- interval metering.41 The number and distribution of those ation and transmission system, and the diversity of all meters should be determined to provide a representative usage should be reflected, whether at the highest system mix of customer loads within the class (or other subgroups hour of the year (a method known as 1 CP, for coincident of interest) and to produce estimates of critical values (such peak), the highest hour of each month (12 CP) or the as contribution to the monthly system peak load) that reach highest 200 hours of the year (200 CP), all on-peak target levels of statistical significance.42 These samples are hours, midpeak hours and off-peak hours, or any other typically a few hundred per class in order to meet the PURPA criteria relevant for allocation. standard. Second, some smaller utilities borrow “proxy data” Table 5 on the next page shows illustrative load research from a nearby utility with similar customer characteristics data for four customer classes. For the purposes of clear and more robust load research capabilities. Class load data examples throughout the manual, we adopt the convention 41 Utilities usually have interval meters on customers over some consumption threshold for billing purposes. Smaller customers may have meters that record only total energy consumption over the billing period (typically a month), or both monthly energy and maximum hourly (or 15-minute) demand, neither of which provides any useful data for allocating timedependent costs. 42 In 1979, FERC issued regulations to implement PURPA § 133 (16 U.S.C. § 2643), which requires the gathering of information on the cost of service. C.F.R. Title 18, Chapter 1, Subchapter K, Part 290.403(b) established the requirement, since repealed, that “the sampling method and procedures for collecting, processing, and analyzing the sample loads, taken together, shall be designed so as to provide reasonably accurate data consistent with available technology and equipment. An accuracy of plus or minus 10 percent at the 90 percent confidence level shall be used as a target for the measurement of group loads at the time of system and customer group peaks.” See Federal Energy Regulatory Commission Order 48 (1979).Page 68 of 276
66 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Table 5. Illustrative load research data Residential Secondary commercial Primary industrial Street lighting Total 1,000,000 1,000,000 1,000,000 100,000 3,100,000 1,000,000 1,000,000 N/A 100,000 2,100,000 Summer 600,000 650,000 500,000 30,000 1,780,000 Winter 400,000 350,000 500,000 70,000 1,320,000 Daytime 600,000 700,000 500,000 0 1,800,000 Off-peak 400,000 350,000 500,000 90,000 1,340,000 Midpeak 550,000 600,000 470,000 9,000 1,629,000 Critical peak 50,000 50,000 30,000 1,000 131,000 Line transformers used 20,000 10,000 N/A 20,000 50,000 Transformers, services Customers 100,000 20,000 2,000 50,000 172,000 Billing 2,000 1,000 N/A 100 3,100 Input to line transformers Class NCP: circuit 400 400 250 100 1,150 Primary distribution Class NCP: substation 300 300 225 100 925 Substations System 1 CP 250 300 200 0 750 System monthly 12 CP 225 250 175 10 660 System 200 CP 200 240 150 10 600 Used for Energy metrics (MWhs) Total Total secondary Energy by time period All energy-related costs, including generation, transmission, primary distribution Customer metrics Demand metrics (MWs) Sum of customer NCP Transmission, generation of a commercial customer class of all general service voltage (primary industrial) have no utility-provided line customers served at secondary voltage, labeled as “Secondary transformers, and the first level at which their demand is commercial,” and an industrial customer class of all general typically relevant is the circuit level. service customers served at primary voltage, labeled as “Primary industrial.” The street lighting class is important to note with respect to the volatility of results. Because this class has In this illustration, the sum of individual customer zero daytime usage and a very different (typically completely noncoincident peak demands is 3,100 MWs, excluding the stable overnight) load profile than other classes, it is highly primary industrial class that is not shown in the table.43 affected by the choice between noncoincident methods and However, the coincident peak demand served by the either coincident or hourly methods. In addition, because utility becomes more diverse as we move up the system, a streetlights represent many points of delivery but are typically phenomenon described in more detail in Section 5.1. As a located only in places where other customers are nearby, this result, the observed coincident peak demands are lower at class almost never “causes” the installation of a transformer more broadly shared portions of the system. At the highest or the creation of a secondary delivery point but also does level, this illustrative system has a 750-MW coincident peak account for a huge number of the individual points of use demand for the highest single hour, labeled as “System 1 CP.” In between, the sum of the class NCPs at the circuit level, labeled as “Class NCP: circuit,” is 1,150 MWs, and the sum of the class NCPs at the substation level, labeled as “Class NCP: substation,” is 925 MWs. Customers served at primary 43 In Table 5, the sum of customer NCPs for the primary industrial class is shown as “N/A” because these customers do not use line transformers and thus this demand metric is not generally relevant to this class. For more general purposes, we are assuming that the sum of customer NCPs for the primary industrial class in this illustration is 300 MWs, bringing the overall total to 3,400 MWs.Page 69 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 67 Table 6. Simple allocation factors derived from illustrative load research data Residential Secondary commercial Primary industrial Street lighting Used for Energy metrics (MWhs) Total 32% 32% 32% 3% 48% 48% N/A 5% Summer 34% 37% 28% 2% Winter 30% 27% 38% 5% Daytime 33% 39% 28% 0% Off-peak 30% 26% 37% 7% Midpeak 34% 37% 29% 1% 38% 38% 23% 1% Line transformers used 40% 20% N/A 40% Transformers, services Customers 79% 17% 3% 1% Billing 65% 32% N/A 3% Input to line transformers Total secondary Energy by time period Critical peak All energy-related costs, including generation, transmission, distribution Customer metrics Demand metrics (MWs) Sum of customer NCP Class NCP: circuit 35% 35% 22% 9% Primary distribution (legacy) Class NCP: substation 32% 32% 24% 11% Substations System 1 CP 33% 40% 27% 0% System monthly 12 CP 34% 38% 27% 2% System 200 CP 33% 40% 25% 2% Transmission, generation Note: Class percentages may not add up to 100 because of rounding. on the system. Put another way, we all like streetlights near system total, then converting to percentages. For embedded our homes and businesses, but nearly all of them go in as a cost of service studies, this manual recommends the use of secondary effect of residential or commercial development; a class hourly energy use as a common allocation factor for all few are along major highways without a nearby residence or shared system components in generation, transmission and business, but these are rare. distribution where the system is made up of components The next step is generating allocation factors to be used in essential for service at any hour, but sized for maximum the allocation phase of the cost study. For embedded cost stud- levels of usage, and where the class contribution to that ies, these are applied to the total investment and expense by usage varies. The only one of these factors that is not self- FERC account, while in marginal cost studies they are applied explanatory is the midpeak factor, which takes both on-peak to the calculated unit costs for each type of system component. and critical peak usage into account, reflecting class usage Table 6 shows the data above converted to allocation in all higher-cost hours. This is illustrative of the probability- factors. The only implicit assumption is that the circuit-level of-dispatch method, in which the likelihood of any resource peak demand for the residential class is one-fourth of the being dispatched at specified hours is measured. There is no customer NCP demand due to load diversity and that for diversity of street lighting usage in this example, but little the commercial class it is one-half, reflecting lower diversity or no demand imposed at the system peak hours. Customer of commercial customer usage across the day compared weighting factors are typically based on the relative cost of with residential load. The raw factors are computed simply meters and billing services for different types of customers, by dividing each class contribution to each category by the based on complexity.Page 70 of 276
68 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Table 7. Composite allocation factors derived from illustrative load research data Method Equivalent peaker Components 20% system 200 CP/ 80% energy Residential Secondary commercial Primary industrial Street lighting Used for 32% 34% 31% 3% Generation, transmission On-peak 50% midpeak/ 50% critical peak 36% 38% 26% 1% Peaking generation Average and peak 50% class NCP/ 50% energy 34% 34% 27% 6% Primary distribution Minimum system 50% customer/ 50% class NCP: circuit 57% 26% 12% 5% Equivalent peaker for transformers 20% delivery points/ 80% customer NCP 60% 30% 0% 11% Circuits (legacy) Line transformers and secondary service lines Note: Class percentages may not add up to 100 because of rounding. In Table 6, we have calculated allocation factors shown as Given the wide diversity of utilities and their load a class percentage of each usage metric. In Part II, we discuss patterns, readers should be careful about overgeneralizing in what circumstances each of these will be appropriate for from these illustrative examples. However, some patterns embedded cost of service studies. In many cases, weighted will hold true across the board. For example, the minimum combinations of these are appropriate. Several commonly system method will always allocate more costs to classes with used composite allocation factors are shown in Table 7, large numbers of customers, at least compared with the basic computed by weighting values in Table 6. customer method.Page 71 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 69 6. Basic Frameworks for Cost Allocation W e group cost allocation studies into two primary Generally speaking, in the traditional model displayed in families. Embedded cost studies look at existing Figure 18 on the next page, functionalization identifies the costs making up the existing revenue require- purpose served by each cost (or the underlying equipment or ment. Marginal cost studies look at changes in cost that activity), classification identifies the general category of fac- will be driven by changes in customer requirements over a tors that drive the need for the cost, and allocation selects the reasonable planning period of perhaps five to 20 years. In the parameter to be used in allocating the cost among classes.44 same family as marginal cost studies, total service long-run Although they are convenient parts of organizing a incremental cost (TSLRIC) studies look at the cost of creating cost of service study, functionalization and classification a new system to provide today’s needs using today’s technol- decisions are not necessarily critical to the final class cost ogies, optimized to today’s needs. Each has a relevant role in allocations. The cost of service study can get to the same final determining the optimal allocation of costs, and regulators allocation in several ways. For example, consider the reality may want to consider more than one type of study when that a portion of transmission costs is driven by the need making allocation decisions for major utilities that affect to interconnect remote generation to avoid fuel costs. This millions of consumers. can be reflected by functionalizing a portion of transmission 6.1 Embedded Cost of Service Studies cost as generation, or by classifying a portion of transmission in the same manner as the remote generation, or it can be recognized by using a systemwide transmission allocator with Embedded cost of service studies may be the most some energy component. In either case, a portion of costs is common form of utility cost allocation study, often termed allocated based on energy throughput, not solely on design “fully allocated cost of service studies.” Most state regulators capacity or actual capacity utilization. require them, and nearly all self-regulated utilities rely on embedded cost of service studies. The distinctive feature 6.1.1 Functionalization In this first step, cost of service studies divide the utility’s of these studies is that they are focused on the cost of service and usage patterns in a test year, typically either accounting costs into a handful of top-level functions that immediately before the filing of the rate case or the future mirror the elements of the electric system. At a minimum, year that begins when new rates are scheduled to take effect. this includes three functions:45 This means there is very little that accounts for changes • Generation:46 the power plants and supporting equip- over time, so it is primarily a static snapshot approach. ment, such as fuel supply and interconnections, Embedded cost of service studies are also closely linked to the as well as purchased power. revenue requirement approved in a rate case, which can be administratively convenient. 44 The third step is usually called allocation, which is the same as the name of the entire process. This step involves the selection or development of allocation factors. Some analysts refer to this third step as factor allocation to prevent confusion. 45 Some of the costs, such as for energy efficiency programs and advanced • Transmission: high-voltage lines (which may range from 50 kV to over 300 kV) and the substations connecting meters, may serve multiple functions and must be assigned among those functions or treated as special functional categories. 46 Some sources use the term “production” instead. This manual uses the term “generation” and generally includes exports from storage facilities under this category.
As listed on the current system
Prefiled testimony: 10/21/2026 - Sponsor: TBD / Witness: Melissa Whited [26-05-10]