Page 84 of 276
82 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® One advantage of a TSLRIC study over a NERA-style method to set rates for new customers or incremental usage. study is that no class is advantaged or disadvantaged by a Some jurisdictions have applied this technique for rate design current surplus or deficiency of power supply or distribution within classes — as the foundation for most “economic network capacity, since costs for all classes would be based development” rate discounts where marginal costs are lower on an optimal mix of resources to serve today’s needs. This is than embedded costs, as well as for inclining block rates one of the most common critiques of the NERA methodology where marginal costs are higher than embedded costs. In — that it favors any class that is served dominantly by the addition, some jurisdictions have applied this technique elements of a system that are in surplus. across rate classes, allocating new incremental resources to 6.3 Combining Frameworks Several jurisdictions require both an embedded and specific rate classes. Depending on the trajectory of costs, this can have two different intended purposes: • To provide a foundation upon which to impose on a marginal cost of service study to support cost allocation fast-growing classes the high costs of growth and to and rate design. As a result, utilities and other parties shelter slower-growing classes from these new costs. may file several studies in the course of a rate proceeding. • To provide a foundation to give the benefit of low-cost A regulator may reasonably use multiple cost studies in new resources to the growing class. reaching decisions, using multiple results to define a range This approach to differential treatment of incremental of reasonableness. Within that range, the regulator can resources may be applicable to situations where costs are apply judgment and all of the relevant non-cost concerns to being driven by disparate growth among customer classes. determine the allocation of the revenue requirements among In the 1980s, for example, commercial loads in the U.S. grew classes. Furthermore, the different types of studies provide much faster than residential loads, and this technique could different information that can be used at other stages in the be used to assign the cost of expensive new resources to the rate-making process. classes causing those new costs to be incurred. One approach is to use embedded cost methods to determine the allocation of the revenue requirement among customer classes and then a forward-looking cost method of some kind to design rates within classes. This applies the 6.4 Using Cost of Service Study Results Quantitative cost of service study results should serve focus of embedded cost studies on equitably sharing the only as a guide to the allocation of revenue responsibility costs among classes while maximizing the efficiency of price among classes, not as the sole determinant. Even the best signals in the actual rates that individual customers face in cost of service study reflects many judgments, assumptions making consumption decisions that will affect future costs. and inputs. Other reasonable judgments, assumptions and The appropriate form of price signals can also be influenced inputs would result in different cost allocations. Additionally, by externalities that are not part of the embedded costs for a loads may be unstable, significantly changing class revenue regulated utility. For example, many regulatory agencies that responsibility between cost studies, particularly for traditional allocate costs among classes on embedded costs have reflect- studies that base costs on single peak hours in one or several ed higher long-run marginal costs in adopting inclining block months. More globally, concepts of equity extend beyond the or time-of-use rates for customers with high levels of usage cost of service study’s assignment of responsibility for causing (either because large customers are better able to respond costs or using the services provided by those costs to include to price signals or because the larger customers have more relative ability to pay, gradualism in rate changes, differential expensive load shapes, such as for space conditioning). risks by function and class and other policy considerations. In some situations, regulators will use one costing method to set rates for existing load while using a different Chapter 27 addresses the many ways in which the results of cost of service studies can be used to guide regulators.Page 85 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 83 7. Key Issues for 21st Century Cost Allocation M any important cost allocation issues for the These changes both enable and require new approaches current era are fundamentally different from in order to efficiently and equitably allocate costs across those that existed when NARUC published its customer classes. 1992 Electric Utility Cost Allocation Manual. This chapter sets forth the changes the industry has experienced and describes the approaches that may be needed to address those changes 7.1.1 Distribution System Monitoring and Advanced Metering Infrastructure in cost allocation studies. Inevitably, additional costing issues will emerge and In the past, customer meters were used solely to measure usage and render bills. Today, so-called smart meters are require recognition in future cost of service studies. The part of a complex web of assets that enable energy efficiency, fundamental considerations are why the costs were incurred peak load management and improved system reliability, in and who currently benefits from the costs. Costs are often addition to the traditional measuring of usage and rendering categorized using engineering and accounting perspectives of bills. that are useful for many applications but must not be More recently, a number of utilities have used advanced allowed to obscure the fundamental questions of causation meters to support demand response and other programs. and benefits. Sacramento Municipal Utility District, for example, ran a pilot 7.1 Changes to Technology and the Electric System Technological change has affected every element of the electric system since the studies and decisions that informed program to test the impacts of dynamic pricing and smart technology on peak load shaving and energy conservation. Figure 22 on the next page shows how customers in the program took steps to lower their electricity usage during highload, higher-cost hours (Potter, George and Jimenez, 2014). Smart meters (along with supporting data acquisition the 1992 NARUC cost allocation manual. These changes include: and data management hardware and software) can provide a • number of services that improve reliability and reduce costs • • Improved distribution system monitoring and advanced metering infrastructure, leading to new comprehensive of generation, transmission and distribution.56 Analysts have data on the system and customers. identified a wide range of expected and potential benefits. Evolution of resource options to include significant These include: amounts of variable renewables, new types of storage, • Reduced line losses. energy efficiency and demand response. • Voltage control. Significant commitments to DERs behind customer • Improved system planning and transformer sizing. meters, including rooftop solar and storage. • The ability to implement rate designs that encourage energy efficiency. • Beneficial electrification of transportation. • Changes in fuel prices and the resource supply mix that • Reduced peak loads. have dramatically changed the operating pattern of • Integration of EVs and renewables. various generation resources (addressed in more detail in Section 7.2). 56 The broader concept of “smart grid” includes distribution (and sometimes transmission) automation devices such as automatic reclosers, voltage controls, switchable capacitors and sensors.Page 86 of 276
84 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Figure 22. Customer behavior in Sacramento Municipal Utility District pricing pilot Default critical peak pricing Percentage of customers 100% Default time-of-use and critical peak pricing 90% Default time-of-use pricing 80% Opt-in critical peak pricing Opt-in time-of-use pricing 70% 60% 50% 40% 30% 20% 10% 0% Did laundry off-peak Turned off lights Did dishes off-peak Turned off air conditioner Increased temperature on thermostat Source: Potter, J., George, S., and Jimenez, L. (2014). SmartPricing Options Final Evaluation Operating savings from, among other things, reduced demand that had been roughly constant for decades. Due to labor needs and improved outage management. significant solar capacity in some regions, such as California Lastly, smart meters, distribution sensors and modern and Hawaii, costs (e.g., extra spinning reserves, out-of-merit computing power provide utilities with large amounts of data dispatch or quick-start generation) may also be incurred to that can be used to determine the usage patterns of distribu- rapidly ramp up other generation as solar output falls in the tion and transmission equipment in great detail and support late afternoon, particularly if customer load does not drop direct hourly allocation of costs. dramatically from afternoon to evening.58 Excess solar gener- • ation may create ramping costs, while storage resources may 7.1.2 Variable Renewables, Storage, Energy Efficiency and Demand Response New variable renewable resources, such as wind and reduce ramping costs by both raising load at the beginning of the ramp period and trimming the peak toward the end of the ramp period. solar, are highly capital-intensive, and their contribution In Hawaii, June load shapes changed as increased levels to system reliability varies greatly from region to region of distributed solar were added to the system. Figure 23 on the depending on when their generation occurs relative to peak next page illustrates this, using data from the Federal Energy demand.57 The emergence of demand response as a service Regulatory Commission (n.d.). In 2006, the system peak provides an opportunity to meet narrow periods of peak demand was approximately 1,200 MWs at 1 to 3 p.m. By 2017, demand with relatively little capital investment by rewarding with extensive deployment of customer-sited solar, the peak customers who curtail usage on request. demand was 1,068 MWs at 9 p.m. A cost allocation scheme Investments in renewable resources, driven by policy and economic trends, can greatly change patterns in supply and 57 Growth in solar resources, whether central or distributed, gradually reduces the reliability value of incremental solar capacity in many respects; the same is true for wind resources with respect to the reliability value of incremental wind and the equivalent for (if they become economically must be adaptable enough to be relevant as significant changes in the shape and character of utility-served load take place. competitive) tidal and wave energy. In contrast, these different resources may be complementary to one another in certain respects. 58 The resulting load shape, first identified by Denholm, Margolis and Milford in 2008, is commonly known as a duck curve. See also Lazar (2016).Page 87 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA Figure 23. Evolution of system load in Hawaii on typical June weekday | 85 well to the shape of the summer diurnal load (Slusarewicz and Cohan, 2018; Electric Reliability Council of Texas, 2019). The costs of these resources can be assigned to the 1,200 hours in which they generate energy, as discussed in Chapter 17. Determining the hours that variable resources June 13, 2006 provide energy (on either a historical or normalized forecast basis) is generally straightforward. System demand in megawatts June 5, 2012 Distributed storage presents other issues and 1,000 opportunities, as it is a capital-intensive peaking resource with no direct fuel costs, dependent on charging from other resources, and provides a variety of energy, capacity, transmission, distribution and ancillary services to the system and sometimes backup supply to host customers. Storage may June 20, 2017 800 displace T&D investments, reduce fuel consumption, enable renewable energy integration and provide emergency service at customer sites. Each of these functions has a different place in a modern cost allocation study. A portfolio of energy efficiency measures reduces energy 600 0 2 4 6 8 10 12 14 16 18 20 22 24 Hour of day Data source: Federal Energy Regulatory Commission. Form No. 714 — Annual Balancing Authority Area and Planning Area Report The capacity role and treatment of variable renewable requirements, generation capacity requirements and stress on T&D equipment, as well as reduces customer billing determinants. As discussed in Section 14.1, energy efficiency expenditures can be classified and allocated in proportion to the benefits they produce. The plans and evaluation resources, such as wind and solar, vary among jurisdictions reports of the program administrator (the utility or a third and RTOs. The cost of service study should reflect the role of party authorized to provide those services) generally provide these resources in supply planning, by classifying part of the sufficient data on the load shape and class distribution of load renewable costs as demand-related and allocating those costs reductions. Since energy efficiency costs are recovered through in proportion to class consumption in the hours contributing a variety of mechanisms (rate based or expensed, through base to capacity requirements. This should recognize that different rates or a discrete conservation surcharge or rider), the cost types of variable renewable resources can be complementary allocation should reflect the cost recovery method. in many respects as long as the temporal patterns, either The costs of demand response programs — direct load daily or seasonal, are different. Even solar in slightly different control, customer load automation (e.g., setback thermostats) regions can be complementary since they may not be affected and price-responsive load (e.g., critical peak pricing) — in an identical way by cloud cover. For example, as shown should similarly be apportioned to reflect their benefits, so in Figure 24 on the next page, a mix of wind resources from that cost-effective demand response is a net benefit to both West and South Texas plus solar production combine to pro- participants and nonparticipants.59 An hourly assignment duce an overall resource shape that corresponds moderately method, where the costs of demand response are apportioned 59 Under conventional rate designs, participants (and their classes) generally retain a smaller share of the benefits of demand response (other than incentives for program participation, which may include peak-time rebates) than of energy efficiency programs. Depending on the program design, the incentives for the participants may be reflected in cost allocation and rate design through (1) reduced allocation of costs to the participating customers and classes to reflect improved load shape, (2) payment of incentives (including peak-time rebates) and allocation of those and other utility expenditures as costs, or (3) a combination of the two, as long as the benefits are not double-counted. Dynamic peak pricing may encourage demand response without explicit incentives, with the cost allocation to the participants’ class reflecting the improved load shape.Page 88 of 276
86 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Figure 24. Illustrative Texas wind and solar resource compared with load shape 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hour of day Combined generation Wind in West Texas Solar Wind in South Texas July average load Sources: Adapted from Slusarewicz, J., and Cohan, D. (2018). Assessing Solar and Wind Complementarity in Texas [Licensed under http://creativecommons.org/licenses/by/4.0]. Load data from Electric Reliability Council of Texas. (2019). 2018 ERCOT Hourly Load Data to the hours when it is called upon (to reduce load or provide decades. However, the precise rate of expansion is uncertain. operating reserves), may help match costs to benefits across Figure 25 shows three alternative projections for sales of classes. electric vehicles (Rissman, 2017). For cost allocation purposes, there are two interrelated 7.1.3 Beneficial Electrification of Transportation issues: how to treat existing customers who adopt EVs as well as new dedicated EV charging accounts, and how to allocate Electric vehicles currently use less than 1% of the nation’s electricity, but that is expected to rise sharply in the next two the costs of new utility EV programs, both for demand management and investments in charging stations. Figure 25. Forecasts of electric vehicle share of sales Percentage of new light-duty vehicle sales 70% Bloomberg NEF 60% Energy Policy Simulator 50% 40% 30% 20% US Energy Information Administration 10% 0% 2015 2020 2025 2030 2035 2040 2045 2050 Note: Projections of U.S. market share of EVs are from the Energy Policy Simulator 1.3.1 BAU case, the Energy Information Administration Annual Energy Outlook 2017 “No Clean Power Plan” side case, and the Bloomberg NEF Electric Vehicle Outlook 2017. Source: Rissman, J. (2017). The Future of Electric Vehicles in the U.S.Page 89 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 87 Figure 26. Estimated grid integration costs for electric vehicles Average marginal cost per plug-in EV $250 $200 $150 No time-of-use pricing 12 a.m. time-of-use pricing $100 $50 $0 2012 Smart charging* 2014 2016 2018 2020 2022 2024 *Not including costs to implement smart charging technology Source: Sacramento Municipal Utility District, personal communication, July 8, 2019 EVs are first being adopted in light-duty vehicle and whether EV adoption is high enough within the rate class market segments, which primarily equates to residential to have an impact on the other customers. However, assuming adoption. These EVs are charged predominantly at home; for the sake of argument that these thresholds are crossed, there is a general consensus that home charging comprises there are alternative ways to address the issue. It is not a over 80% on average (U.S. Department of Energy, n.d.). given that EV charging will increase system peak or otherwise This home EV charging represents a substantial, but not negatively impact other customers. Time-of-use rates and totally unprecedented, amount of new consumption for a other demand management programs can significantly lessen residential customer. The annual consumption for an EV these impacts. Figure 26 shows estimated grid integration represents slightly less than the consumption required for costs for uncontrolled EV charging and two alternative a typical electric water heater (U.S. Department of Energy, methods for managing EV load (Sacramento Municipal Utility n.d.). If uncontrolled, however, this additional consumption District, personal communication, July 8, 2019). could change the load profile significantly for this subset of Many jurisdictions are moving toward widespread TOU customers, potentially leading to additional system costs. rates for residential customers. If these rates are mandatory For example, if EVs begin to charge at home right after the for residential customers or even just the default for residen- workday ends and the sun is setting, then this could increase tial customers with EVs, then that would likely eliminate any system peak and exacerbate ramping issues. cross-subsidy issues between residential customers with and Between rate classes, changes in load profiles can be easily without EVs. Similarly, EVs can be easily integrated into other accounted for in future rate cases as long as there is sufficient demand management programs, or programs specific to EVs load research data on the issue. However, there could also be can be examined. significant changes in customer load profiles within each rate At some point, similar issues may arise for workplace class. As a result, some analysts have suggested that residential charging for light-duty vehicles, and it will be desirable to customers with EVs should be a separate rate class. As a concentrate charging into the hours when generation and threshold matter as discussed in Section 5.2, it is an empirical delivery system capacity is available and unused. For example, question whether customers with EVs have distinct cost it may be desirable to concentrate workplace EV charging characteristics from other customers in the same rate class during periods when solar generation is prevalent.Page 90 of 276
88 | ELECTRIC COST ALLOCATION FOR A NEW ERA As of this writing, many different heavy-duty EVs are REGULATORY ASSISTANCE PROJECT (RAP)® outright discounts or alternative rate structures. To date, beginning to be adopted. Many jurisdictions have started to there are significant tensions in all of the proposed solutions adopt electric buses, and a wide range of electric trucks are for these DC fast charging accounts. Given the significant under development, from postal and parcel urban delivery site infrastructure needed to connect the uncontrolled power vehicles to long-haul semitrailers. Fleets of these vehicles will draw from DC fast chargers, the customer NCP demand for have charging requirements measured in MWs, not kWs, and these accounts could be a relevant cost driver. RAP’s preferred it may be desirable to locate these charging facilities where C&I rate design accounts for this by requiring modest they can be directly served from the transmission network, customer NCP demand charges for site infrastructure avoiding the primary distribution network altogether. In this ($1 to $2 per kW) with other elements of the rates established case, these sites will be more like large industrial high-volt- on a time-varying per-kWh basis. Such a rate would provide age customers for cost analysis purposes. Making potential the right blend of incentives to manage usage for DC fast customers aware of this option, to access lower-cost power by chargers through storage or other techniques. As a result, locating adjacent to transmission capacity, may help guide the reforming rate design for C&I customers could be the optimal evolution of this market segment on an economical pathway. solution to this issue, instead of establishing separate rate Lastly, the development of public DC fast charging, classes for DC fast charging or providing arbitrary discounts thought by many to be a prerequisite to scale up EV adoption under existing C&I rate designs. dramatically, is posing a range of new public policy issues. Several states have also begun to implement utility EV DC fast chargers allow for significantly faster recharging than programs, and many more states are considering policies other charging methods, which may be necessary for a variety in this area. Expenditures by regulated utilities to support of EV use cases, including long-distance travel and adoption electric vehicles are justified on a wide array of grounds: in areas where residents cannot charge at home. The power • rating of DC fast chargers is typically over 50 kWs per charging port and could increase significantly (Nicholas and Societal benefits: public health and climate benefits, energy independence and reduced noise. • Electric system benefits to all ratepayers: new load Hall, 2018). These characteristics mean that DC fast chargers at beneficial off-peak hours and flexible new loads to typically cannot be installed for single-family residential optimize ramping. customers. However, DC fast chargers can be installed at • Benefits to participating customers and EV drivers: many commercial and industrial locations with a sufficient increased convenience, lower total driving costs and the service capacity (e.g., a mall) or connected directly as a stand- potential to attract new customers to retail businesses. alone C&I customer with a separate account. One category of utility EV programs is quite similar Many jurisdictions have been wrestling with the proper to other energy and demand management programs. In rate class and rate design for stand-alone DC fast charger the aggregate, uncontrolled EV load could be a significant accounts. This is because these accounts have a load profile addition to peak load that drives many system costs. These without an obvious correspondence to other C&I rate classes. utility EV programs encourage, or in some cases ensure, These accounts have typically been placed in rate classes with that EV charging will take place during off-peak hours to significant demand charges. However, given the high kW minimize system stress and long-run electric system costs. power rating and low utilization rates at this early stage of EV The justifications for these programs and the principles adoption, high demand charges lead to extraordinarily high for allocating the costs are not very different from other bills for these fast charging accounts, at least on an average energy management and demand response programs, with cost per kWh basis. Given the broader public policy need for functionalization, classification and allocation according public DC fast charging, a number of jurisdictions have begun to the benefits of the program or alternatively to classes in to take steps to lower bills for these accounts, either through proportion to customer participation.Page 91 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® In contrast, another major category of utility EV ELECTRIC COST ALLOCATION FOR A NEW ERA | 89 with efforts to jump-start an infant industry. EV charging programs does raise new questions. Utility expenditures and station program cost responsibility could be more directly investments in support of charging infrastructure are taking a concentrated toward EV drivers over time. This could mean wide variety of forms, including rebates, additional allowances specialized ongoing cost recovery mechanisms, including for interconnection costs, and direct utility ownership and direct assignment of identifiable EV-related costs. However, operation of end-use charging stations. In most of these a jurisdiction that is seeking to accelerate EV adoption would programs, participants are expected to bear some of the costs certainly be free to apply short-run marginal cost-based eco- of the charging station, either upfront or ongoing, although nomic development rates to EV charging development while a few programs may include full utility ownership and simultaneously socializing EV program costs to all ratepayers. responsibility for all ongoing costs. Drivers of EVs are certainly the most direct beneficiaries of these programs, but there are 7.1.4 Distributed Energy Resources a wide range of potential benefits for other ratepayers and Over the last decade, DERs, particularly rooftop solar, society at large. Depending on the perspective, this could have gained significant traction in many jurisdictions. Many justify a wide range of cost allocation techniques, including: states adopted net metering rules for rooftop solar and other • Direct assignment to the customer classes receiving free eligible technologies in the 2000s.62 The federal government or subsidized equipment.60 also established the investment tax credit for commercial and Allocation to all classes in proportion to class revenues residential solar systems in 2005, which was thereafter extend- or energy use to reflect the benefits to each class from ed and expanded to other solar applications. Starting in the increased sales and reduced average costs. late 2000s, costs for solar panels started to drop quickly. These Direct assignment to EV program accounts or a broader policies and trends, in addition to a range of additional state group of identifiable EV customers as program beneficia- policies and incentives, have created a significant new market ries.61 for rooftop solar. As shown in Figure 27 on the next page, These programs are still quite new at the time of adoption of residential solar accelerated to significant levels in publication for this manual, so many of the important the mid-2010s, with more than 2 GWs of installations annually issues are only beginning to be investigated. This is further from 2015 through 2018 (Wood Mackenzie Power & Renew- complicated by cross-cutting issues, such as the integration of ables and Solar Energy Industries Association, 2019, p. 20). energy management programs into utility EV infrastructure Customer-sited adoption of solar can raise several investments and the impacts of cost allocation decisions on cost allocation issues. Unlike EVs, distributed solar reduces the competitive EV charging market and charging station customer load. At the macro level, for utilities without providers who do not (or cannot) benefit from utility support. decoupling, this can lead to underrecovery of revenue One logical outcome across these issues could be apply- and necessitate more frequent rate cases. If adoption of • • ing fully loaded time-varying rates to identifiable EV ac- distributed solar is captured in the load research data, then counts, which may provide higher incremental revenue than cost allocation between rate classes may change over time incremental costs in those hours. This would have the effect depending on the cost allocation techniques used. of socializing a substantial portion of EV program costs across a broader group of ratepayers. This would be consistent 60 The number of EV program participants in a class, but not the total number of customers in the class, may be relevant to allocation of the costs. 61 There are a number of potential variants on this. Direct recovery of costs from a given customer for installation at that customer’s site over time would act as a financing mechanism for that customer. However, specific program costs (e.g., a DC fast charger program) could be recovered The more difficult issue that jurisdictions around the country have been wrestling with is the possibility of through a combination of subsidies from other classes and an ongoing perkWh basis from the accounts that participated in that program. 62 The 2005 Energy Policy Act added net metering to the PURPA standards that each state was required to consider. Pub. L. No. 109-58 § 1251. Retrieved from https://www.congress.gov/109/plaws/publ58/PLAW109publ58.pdfPage 92 of 276
90 | ELECTRIC COST ALLOCATION FOR A NEW ERA REGULATORY ASSISTANCE PROJECT (RAP)® Figure 27. US solar photovoltaic installations 18,000 Utility Capacity in megawatts 16,000 Nonresidential 14,000 Residential 12,000 10,000 8,000 6,000 4,000 2,000 0 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 Estimated 2023 2024 Source: Wood Mackenzie Power & Renewables and Solar Energy Industries Association. (2019, March). U.S. Solar Market Insight intraclass cross-subsidies between customers with solar and likelihood of lower impacts given the offsetting benefits of those without. Many utilities have proposed special rate de- solar generation.63 signs, changes to net metering rules and separate rate classes Even in jurisdictions with significant penetration levels for customers with solar. As always, the threshold issue for of distributed solar, there have been robust debates about the creating a new rate class is whether customers with solar are existence of significant cross-subsidies and the proper means having material impacts on the other customers. Some util- to address them. As a general matter, most proposals to ities and consumer advocates argue that net metering rules establish separate rate classes for distributed solar have been allow customers with solar to pay less than their fair share of denied so far.64 Utilities have also proposed higher customer system costs. It is important to quantitatively evaluate these charges and special demand charges for solar customers, concerns before making policy adjustments to address them. which have not been widely adopted. However, a variety To begin, the levels of distributed solar adoption across of rate design changes have been adopted to better align the country are quite uneven. While many jurisdictions have compensation with value and reduce the potential for unrea- significant levels of adoption, particularly those with either sonable cross-subsidies. California has begun to address these strong solar resources (such as California and Hawaii) or sup- issues by requiring new residential net metering customers portive state policy environments, many other jurisdictions to be placed on TOU rates, a measure that is integrated with have low levels of adoption. In jurisdictions with low levels a move toward TOU rates for residential customers more of adoption, the impacts on other customers are necessarily generally (California Public Utilities Commission, n.d. and quite small. If only 1% of class load is accounted for by dis- 2016). New York’s Value of Distributed Energy Resources tributed solar, then the worst-case scenario is approximately proceeding has set up specialized export credit compensation 1% higher bills for nonparticipating customers, with a strong for large distributed energy projects, which include values 63 Net ratepayer impacts from solar policies depend on many factors. In jurisdictions with significant renewable portfolio standard costs or separate solar incentive programs, these costs can be quite different than in jurisdictions where the primary solar compensation policy is net metering. It is important to distinguish whether costs to nonparticipating ratepayers are occurring because of the RPS, dedicated solar incentive programs or net metering policies. 64 The exception to date is Kansas, although separate rate classes for solar customers have been authorized by legislative action in additional states (Trabish, 2017). At the time of this writing, this area of policy is rapidly evolving.Page 93 of 276
REGULATORY ASSISTANCE PROJECT (RAP)® ELECTRIC COST ALLOCATION FOR A NEW ERA | 91 Figure 28. Substation backfeeding during high solar hours 6 Average transformer load — December 5 Backfeed occurring 10 a.m. to 2 p.m. 2010 Load in megawatts 2011 4 2012 2013 3 2 August 8, 2013, backfeed condition 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hour of day Source: Hawaiian Electric Company. (2014, April 30). Minimum Day Time Load Calculation and Screening. Distributed Generation Interconnection Collaborative (DGIC) webinar for energy, capacity, delivery and environmental externalities or transmission voltage customers receive a portion of their (New York Public Service Commission, 2017). Tensions in power from generating facilities located along distribution these debates include differentials between short-term and circuits. Where this occurs, some provision should be made to long-term avoided costs due to distributed generation and treat a portion of the distribution investment as a generation- how to consider significant societal externalities such as related cost. Figure 28 shows how some distribution greenhouse gas emissions. substations may backfeed to the transmission system during Customer-sited storage is another DER that is expected solar hours, even if the solar facilities are sited exclusively to grow in importance in the coming decades. Storage can be on the rooftops of secondary voltage customers (Hawaiian used to change the load profile for adopting customers and Electric Company, 2014). even export energy to the grid if the jurisdiction allows it. Under flat volumetric rates, there is little incentive to manage energy usage with storage and little risk of unusually signifi- 7.2 Changes to Regulatory Frameworks cant cross-subsidies. However, storage is becoming econom- As also introduced in Chapter 4, many new regulatory ically attractive in many jurisdictions to C&I customers that issues have arisen since the 1992 NARUC Electric Utility Cost have high demand charges. These demand charges may not Allocation Manual, and some older issues have become more be well designed economically, and storage could allow these prominent and widespread. These issues include: customers to lower their bills substantially. More generally, • markets and retail competition. well-designed time-varying rates and demand charges can give the proper incentives for energy management through • Lastly, higher penetrations of DERs will raise new issues • Performance-based revenue frameworks. • Proliferation of trackers and riders recovering costs outside of rate cases. around the allocation of local distribution facilities. As more DERs are added, there will be some systems where primary Holding company issues due to widespread mergers and new utility conglomerates. storage, but poorly designed rates will give customers correspondingly poor incentives. Restructuring and the emergence of organized wholesale • New types of public policy programs.