The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 87 of 98 1 accordingly, serves as an objective basis for escalating historical O&M expenses to the 2 Rate Year. 3 Because ratemaking is inherently forward-looking, the revenue requirement must 4 reflect reasonable estimates of revenues and expenses during the rate-effective period. 5 Accordingly, relying solely on historical expenses, without accounting for reasonably 6 ascertainable and measurable cost increases, would understate the revenue requirement 7 necessary to provide service during that future period. This problem is magnified under 8 a multi-year rate plan with a stay-out commitment, such as the one proposed in this 9 proceeding. In a single-year rate plan, a utility can seek a new rate adjustment if its 10 authorized revenue requirement no longer covers the actual costs of providing service. 11 By contrast, a multi-year rate plan locks in rates for a longer period, increasing the risk 12 that rates will become misaligned with the actual costs of service over time. The further 13 these rates extend into the future, the more pronounced the gap can become between 14 historical expenditures and the actual costs of providing service. To address this, an 15 inflation adjustment is necessary to set a revenue requirement that reasonably reflects 16 the costs of providing service throughout the authorized rate-effective period. The 17 principle is perhaps best summed up by the Virginia Supreme Court: “in exercising its 18 legislative function of fixing utility rates for the future, [a public utilities commission]Page 90 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 88 of 98 1 should not be blind to the future.” Commonwealth v. Virginia Elec. & Power Co., 211 2 Va. 758, 771 (1971). 3 4 5 Q. How do you respond to Mr. Defever’s argument that the Company should not have made an inflation adjustment when calculating the five-year average used to derive the Rate Year funding for non-catastrophic and prestaging expenses? 6 A. Mr. Defever’s recommendation to use an unadjusted average of the Company’s 2021 7 to 2025 non-catastrophic storm costs does appropriately account for inflation in labor, 8 contractor services, materials, equipment, and fuel. Eversource will incur these costs 9 for storm restoration at prevailing 2028 prices, not at the historical prices in the five- 10 year average (2021 – 2025). Accordingly, the Company adjusted its historical storm 11 costs for inflation to more accurately reflect expected costs during the rate-effective 12 period. While a five-year average without an inflation adjustment may smooth annual 13 fluctuations, it understates the cost of service for the rate-effective period. The 14 Company’s proposed adjustment, on the other hand, aligns historical cost data with 15 expected costs during the period in which rates will apply. 16 17 Q. Did the Company apply an inflation adjustment to any other components of its storm cost recovery proposal? 18 A. The Company seeks to establish a fair, balanced, and stable storm cost recovery 19 framework for catastrophic and non-catastrophic storms that reflects the costs 20 reasonably incurred to restore service to customers—an objective it believes all the 21 parties in this proceeding share. To that end, CL&P adjusted not only the proposed 22 base-rate funding but also the threshold for accessing the catastrophic storm reserve for 23 inflation. As explained in its revenue requirement testimony, the Company derived thePage 91 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 89 of 98 1 proposed $5.4 million catastrophic storm threshold by adjusting the current $4 million 2 threshold for inflation from 2018 through the Rate Year using the Gross Domestic 3 Product Price Index (“GDP-PI”) (Exh. CLP-REVREQ-1, at 104). 4 It is important to note that changes to the proposed catastrophic storm threshold, 5 whether upward or downward, affect the Company’s revenue requirement and the 6 required revenue increase. Consequently, if the threshold is adjusted, the Company 7 must adjust base rates to reflect the costs of storms that fall below the new, higher 8 threshold, ensuring that rates are designed to recover a representative level of costs 9 each year. To do otherwise would result in rates that are neither just nor reasonable. 10 IV. RESPONSE TO TESTIMONY REGARDING AMI DEPLOYMENT 11 Q. Please summarize Mr. Balakumar’s AMI testimony. 12 A. Mr. Balakumar characterizes AMI as a foundational investment critical to grid 13 modernization and the shift toward a flexible, cost-effective grid (Balakumar 14 Testimony at 74). He claims, however, that these benefits can only be realized if the 15 technology is fully leveraged and deployed expeditiously. Although he views the 16 Company’s proposal as a solid starting point, Mr. Balakumar claims several gaps must 17 be addressed as a condition to approval (id.). 18 First, the witness recommends several changes to the Company’s customer data access 19 platform. While Mr. Balakumar considers the Green Button Connect and API-based 20 architecture a strong foundation, he urges the Company to provide access not only to 21 billing-quality data, but also to raw meter usage data and enrolled-program informationPage 92 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 90 of 98 1 (id. at 74, 80). He further recommends that the Company track and publicly report 2 additional performance metrics, including the number of registrants, average 3 registration approval time, and platform uptime (id. at 74-75). Mr. Balakumar also 4 asserts that the platform should become a one-stop shop for future data access— 5 including system data and rates or tariff information—to better support distributed 6 energy resource (“DER”) integration (id. at 75-76). 7 Second, Mr. Balakumar argues that the Company’s AMI proposal lacks sufficient detail 8 regarding key implementation elements. For instance, Mr. Balakumar recommends 9 enabling 8760 profiles at both the feeder and substation levels as AMI is deployed (id. 10 at 65, 71, 75, 77-78). 11 deployment in areas with DER and load constraints (id. at 64, 78). Additionally, Mr. 12 Balakumar urges the Company to propose a concrete distributed intelligence pilot with 13 specific use cases within one year of AMI deployment approval (id. at 79). Finally, he 14 requests that the Company assess whether AMI can defer or replace other sensor 15 investments and report on its findings (id. at 80). 16 Mr. Balakumar recommends that PURA approve the Company’s AMI investment, 17 conditioned on the Company meeting these requirements. He also recommends that the Company prioritize AMI 18 Q. What is the Company’s general response to Mr. Balakumar’s AMI testimony? 19 A. The Company appreciates Mr. Balakumar’s general support for its proposed AMI 20 investment and agrees with him that AMI is a foundational investment critical to grid 21 modernization and the shift toward a flexible, cost-effective grid. Regarding hisPage 93 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 91 of 98 1 suggested conditions for approval, the Company can evaluate and address these 2 capabilities as deployment progresses. The AMI proposal is a six-year, systemwide 3 initiative, with benefits accruing in stages as the meters, communications 4 infrastructure, and operational systems are implemented. Mr. Balakumar himself 5 recognizes that the proposal is a solid starting point, and that some capabilities will 6 emerge at the outset while others will only be fully realized after full deployment. Mr. 7 Balakumar’s recommendation to condition approval on a fixed set of additional 8 deliverables is needlessly heavy-handed and risks delaying the very deployment he 9 urges the Company to expedite. 10 Q. What is the Company’s response to Mr. Balakumar’s specific recommendations? 11 A. The Company’s response to Mr. Balakumar’s specific recommendations is as follows: 12 1. Raw meter usage data, enrolled programs, and additional platform metrics 13 The Company intends to track both the number of platform users and the platform’s 14 availability/reliability. 15 Estimation, and Editing (“VEE”) process and available in the Green Button data 16 sharing portal within 12 hours of actual consumption—the Company believes that this 17 satisfies all reasonable use cases and minimizes discrepancies between data subject to 18 sharing and data used for bill calculations. 19 2. Commitment to a “one-stop shop” including system and rates/tariff data 20 Eversource agrees that data access is important to DER integration. However, it does 21 not follow that the Company must commit now to a particular scope for a platform that Usage data will be subjected to the initial Validation,Page 94 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 92 of 98 1 has not yet been built. Additionally, the Company notes that the Green Button Connect 2 data sharing platform is intended to empower customers to control which third-party 3 may receive their usage data, as well as data related to other attributes of their service, 4 such as their specific rate selection and bill components. The following is the list of 5 data fields that will be available for customer-authorized data sharing via the platform. Field Account Number Account Address / Premise Address Premise ID Customer Name Customer Email Address Customer Phone Commodity Customer Rate Code / Tariff Overall Consumption Last Period Overall Consumption This Period Billing Period Bill Amount Customer Charge Energy Service Charge Fixed Peak Demand (for current bill period) Consumption Tax Meter Number Quality of Reading Interval Reading Start Date and Time Interval Duration Interval Reading ValuePage 95 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 93 of 98 Interval Reading Quality Interval Reading Quality Interval Reading Quality Interval Reading Quality Interval Reading Quality Interval Reading Quality Interval Reading Quality Generation Service Charge Distribution Charge Transition Charge Transmission Charge Net Meter Recovery Surcharge Revenue Decoupling Charge Distributed Solar Charge Renewal Energy Charge Energy Efficiency Charge Electric Vehicle Program 1 The Company does not consider it cost-efficient for the AMI program to fund the 2 integration of a customer data sharing platform with non-customer-specific rate 3 information or system data, because the non-proprietary elements of that data are 4 already available in other repositories. 5 3. Iterative 8760 profiles at feeders and substations 6 As part of the RE03 IDSP proceedings, the Company has outlined its fundamental 7 concerns with 8760 forecasts and reiterates that 8760 forecast data does not create 8 incremental value for designing a system that can address peak system demand. 9 However, the Company understands the stakeholders’ and PURA’s interest inPage 96 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 94 of 98 1 producing such forecasts and, as part of this rate case filing, has included a request for 2 incremental FTEs to support such efforts. The Company requests these incremental 3 FTEs, while maintaining that it can already plan its system safely, reliably and cost- 4 effectively using existing forecast details and its current capabilities, as Mr. Balakumar 5 notes, to create hourly load profiles that meet PURA’s NWS process and review 6 criteria. 7 Furthermore, it is important to note that developing time series data does not require 8 AMI availability but can, as the Company has demonstrated, be developed using 9 SCADA telemetry. AMI data will provide value in the forecasting process as it delivers 10 improvements to bottom-up adoption propensity models using resource detection to 11 train models on which customers adopt what technologies. It also supports the creation 12 of standardized or randomized load profiles for probabilistic simulations. In summary, 13 while Mr. Balakumar’s assertions are technically feasible, the value he attributes to 14 them is overstated. Regardless of the use of AMI data, expectations should remain 15 realistic. First, the AMI rollout must be completed, and second, at least 1-2 years of 16 data must be collected before reliable conclusions can be drawn. With PURA’s 17 approval of the requested incremental FTEs for this forecasting effort, the Company 18 can and will develop these datasets. 19 4. Prioritizing deployment by DER and load constraints 20 The Company reiterates its deployment philosophy that hybrid mesh AMI technology 21 is most cost-efficiently deployed by saturating one location with meter installations,Page 97 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 95 of 98 1 then expanding to adjacent areas, which achieves mesh stability more quickly. This 2 approach also provides the quickest path to realizing system-wide benefits for all 3 customers. 4 5. Distributed intelligence pilot within one year of approval 5 The Company notes that it is currently piloting a wide range of Distributed Intelligence 6 (“DI”) capabilities under its Massachusetts AMI program. Therefore, if the Company’s 7 proposal to leverage its Massachusetts technologies for Connecticut is approved, those 8 DI applications with demonstrated value can be readily extended to Connecticut. 9 6. Evaluating AMI’s potential to defer or replace sensor investments 10 Eversource agrees it is important to study the opportunities for AMI to defer or replace 11 sensor investments. As with all reliability-driven distribution investments, Eversource 12 compares options and selects investments to maximize benefit to customers. There are 13 several use cases for distribution line sensors, including load and voltage monitoring, 14 power quality measurements, wildfire risk monitoring, and physical asset 15 condition. The Company’s AMI business case, for instance, has identified the 16 opportunity to use AMI data to avoid the need for voltage sensors required to 17 implement effective Volt VAR optimization programs. In contrast, some sensor-use 18 cases, such as pole tilt monitors, cannot be deferred with AMI. For more advanced use 19 cases, including predictive outage detection, the Company agrees that a formal study 20 to compare efficacy and cost effectiveness of AMI versus other sensor technology is a 21 valuable effort. Any such study, however, should be limited to use cases that are 22 appropriate for comparison with AMI technology.Page 98 of 100
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-LEADERSHIP-REBUTTAL-1 November 18, 2026 Page 96 of 98 1 V. CONCLUSION 2 Q. Do you have any concluding comments? 3 A. Yes. The Company’s objective in this proceeding is to establish a sustainable, 4 balanced, and cohesive ratemaking framework that ensures reliable electric service 5 while maintaining long-term customer affordability. This framework is necessary due 6 to the significant investments required across the CL&P system to enhance reliability, 7 improve resiliency, and modernize utility infrastructure. To ensure these investments 8 remain financially manageable for customers, a comprehensive ratemaking approach 9 is needed—one that considers customer interests beyond the immediate rate case cycle. 10 Specifically, the framework must appropriately balance four fundamental 11 considerations: (1) meeting the service reliability and performance expectations of the 12 Company’s customers and the State of Connecticut; (2) maintaining reasonable and 13 predictable customer rates; (3) promoting cost-effective and efficient utility operations; 14 and (4) establishing a revenue recovery mechanism that ensures sufficient financial 15 support for CL&P to meet these objectives, including an appropriate return on and 16 recovery of its capital investments. 17 The Company’s PBMRP is designed to integrate these considerations into a single, 18 coordinated ratemaking structure. In developing this proposal, CL&P started with the 19 framework under consideration in PURA’s Performance-Based Regulation proceeding 20 (Docket No. 21-05-15RE01) but added features to address shortcomings and defects
As listed on the current system
Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: DONALD J. SCACCO, JR., DIGAUNTO CHATTERJEE AND DOUGLAS P. HORTON [26-05-10]