The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 39 of 52 1 entirely made on the basis of demand using test year demands gives too much weight 2 to existing demands. The Company field engineers, deciding on secondary plant and 3 primary lines local to the customer, do not use today’s demands or test-year class rather 4 they consider connection standards involving: (a) how the equipment will be shared 5 (customer numbers expected to be served downstream of those facilities long-term) and 6 (b) those customers’ demands during the life of those facilities. In other words, an 7 allocation based entirely on class NCP which is test-year customer demands cannot 8 capture the effects of economies of scale that drives plant size requirements and 9 therefore allocating all lines or transformers fully on the basis of class demand is 10 problematic and introduces a bias than the MS study may help reduce. This is, in Ms. 11 Nieto’s view, is the main reason why the MS method has stronger precedent in ACOS 12 studies in the industry. 13 14 Q. Has the Minimum System classification approach been widely adopted in the country? 15 A. Yes, for ACOS studies, the Basic Customer price method is more scarcely adopted than 16 the MS study, for distribution plant. Examples of U.S. utilities where a MS study is 17 used include Alabama Power (AL), Georgia Power Company (GA), Central Hudson 18 Electric & Gas (NY), Central Maine Power (ME), Choctawhatchee Electric 19 Cooperative (FL), Con Edison (NY), Tampa Electric (FL), Connecticut Light & Power 20 (CT), Duke Energy Progress (NC), Gulf Power (FL), Jackson County REMC (IN), 21 Kentucky Utilities (KY), LG&E (KY), Madison Gas & Electric (WI), Mississippi 22 Power (MS), Northern States Power (MN), and Carolina Power & Light (NC).Page 42 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 40 of 52 1 Q. Does NARUC cost allocation manual endorses the MS study? 2 A. Yes. The NARUC Electric Utility Cost Allocation Manual 38 recognizes the minimum 3 system approach as one of the appropriate ACOS methods to determine classification 4 of accounts 364 through 368. The NARUC Manual clearly states that each distribution 5 plant account, 364 through 368, can be separately classified into a demand and 6 customer component. 39 It also adds that: “The customer component of distribution 7 facilities is that portion of costs which varies with the number of customers. Thus, the 8 number of poles, conductors, transformers, services, and meters are directly related to 9 the number of customers on the utility's system.” The only instance where the 10 NARUC’s Manual mentions a method similar to the Basic Customer approach is in the 11 context of the Marginal Cost methods, and this is irrelevant to the discussion of what 12 to use in an ACOS study for customer costs. 13 14 Q. What impact would the basic customer price alternative have for the embedded cost allocations if adopted in lieu of the MS study? 15 A. Ms. Nieto tested the specific impact of an allocation of distribution plant entirely based 16 on the ratio of residential class non-coincident peak demand (NCP) to total Class NCP 17 as part of the interrogatory phase of this Docket, and the main implication of the Basic 18 Customer method is that it shifts a larger share of plant costs to the commercial and 19 industrial customers. This is expected, due to the relatively higher per-customer National Association of Regulatory Utility Commissioners, Electric Utility Cost Allocation Manual, Jan 20, 1992. 38 39 90. See NARUC Electric Utility Cost Allocation Manual, January 20, 1992, Table 6-1 in page 87 and pagePage 43 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 41 of 52 1 demand that commercial customers tend to have, but as explained above, it is a biased 2 result as it misses the fact that larger demands tend to make better use of local 3 transformer’s economies of scale, i.e., they exhibit higher utilization of line 4 transformer. 5 6 Q. What is your opinion regarding the use of modified demand allocation factors to exclude the minimum equipment size as proposed by Ms. Whited? 7 A. There is no doubt that the minimum equipment can serve a share of the load of the 8 customers in each class, and therefore intuitively, one would find reasonable to account 9 for that amount of equipment load serving capability in determining the net class NCP 10 demands for allocation of the demand-related share of the plant. However, a concern is 11 that this approach may add false precision because the class cost responsibility is not 12 entirely proportional to class demand ratios due to utilization of minimum equipment 13 once installed. The MS study does not capture all the nuances of customer density 14 effect in investment decisions. The risk is that such adjustments may lead to mis- 15 allocation of plant to the class with higher demand but also higher utilization per 16 customer. For any distribution plant other than substation and trunkline primary 17 feeders, investment decisions are largely driven by the numbers of customers served 18 and the sizes of the specific transformers and conductors are largely standardized. The 19 MS is a reasonable classification method by designating a minimum portion of the 20 equipment (in the case of line transformers, this is represented by the smaller 21 transformer installed today, which is 10 kVA) as customer-related, covering a 22 minimum load that tends to be only a share of the customer design demand. ThePage 44 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 42 of 52 1 transformer plant required per residential customer is actually larger than the average 2 residential customer’s actual demand. The cost per kVA may also be smaller in any 3 case for a commercial-serving transformer, given the economies of scale of larger 4 transformers. 5 6 Q. Do you agree with Ms. Whited’s proposed reclassification of AMI meters based on customer and demand to be more cost-reflective? 7 A. AMI meters do serve an important role in distribution operations, remote disconnects, 8 and support of demand response programs and tariffs. However, given that AMI meters 9 are practically the new standard in today’s modern utility, and the fact that there is no 10 direct correlation between demand growth and AMI meter need, the cost driver should 11 be the customer additions as in the current ACOS study filed by the Company. 12 V. ADVANCED METERING INFRASTRUCTURE 13 14 Q. Did the Rates Panel submit testimony as part of the Company’s initial filing regarding the proposed Advanced Metering Infrastructure (“AMI”) project. 15 A. No. As part of the Company’s initial filing, Company witnesses Jared Lawrence and 16 Douglas Horton provided testimony regarding the technology and implementation of 17 advanced metering infrastructure, as well as regarding a new cost recovery framework 18 for technology and implementation costs. However, Ms. Whited, on behalf of OCC, 19 recommends that, as part of the AMI implementation, PURA direct the Company to 20 (1) retain hourly interval data from AMI meters in a form suitable for equipment-level 21 aggregation, and (2) in its next base rate case, file an equipment-level allocation study 22 alongside its conventional class cost of service study, so the Authority can compare thePage 45 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 43 of 52 1 results before adopting a new method. 40 Ms. Whited argues that the Company’s 2 demand allocation method for distribution system infrastructure does not reflect 3 localized variance in cost causation. 41 4 Further, Mr. Dauphinais on behalf of CIEC, recommends, to the extent PURA allows 5 CL&P to recover AMI costs, whether through the PBMRP or another mechanism, that 6 PURA reject CL&P’s proposal to allocate those costs on the basis of class distribution 7 revenue and instead, AMI costs should be separately identified and allocated on a cost 8 basis by using the weighted meter cost allocator used in CL&P’s ACOS to allocate 9 Account 370 meter plant. 42 Mr. Dauphinais argues that allocating AMI costs on the 10 basis of class distribution revenue shifts AMI costs to classes whose share of 11 distribution revenue is large relative to the number and cost of their meters, which are 12 primarily the larger commercial and industrial classes. 43 13 Mr. Dauphinais further recommends that PURA direct CL&P to use the same cost- 14 based allocation for the deferred AMI-related O&M expense and stranded AMR meter 15 costs when it seeks recovery of those costs, unless CL&P demonstrates that a different 16 cost-based method is more appropriate. 44 40 Whited at 8, 20-22. 41 Id. 42 Dauphinais at 29-31. 43 Id. 44 Id.Page 46 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 44 of 52 1 2 Q. Do you agree with Mr. Dauphinais’s recommendations regarding allocation of AMI costs? 3 A. For purposes of cost of service analysis, the Company expects that AMI meter costs 4 will be properly classified as customer-related costs, consistent with treatment of meter 5 costs in the allocated cost-of-service study conducted and submitted in this docket as 6 part of the Company’s rate application. The Company’s further expectation is that 7 capital costs and expenses associated with AMI implementation would be collected 8 from customers consistent with allocation of costs allowed in this proceeding for 9 distribution rates or another applicable rate mechanism. While we agree with Mr. 10 Dauphinais in that the classification of costs as customer-related is appropriate, we 11 disagree not necessarily on what the cost-of-service study produces, but that the 12 proposed allocation of such costs and their recovery through the PBMRP, or otherwise 13 as determined by PURA, is appropriate. Please see also the following rebuttal to Ms. 14 Whited’s recommendation. 15 16 Q. Do you agree with Ms. Whited’s recommendation regarding the AMI implementation? 17 A. Similarly, for purposes of cost-of-service analysis, the Company expects AMI meter 18 costs to be properly classified as customer-related costs. The results of the allocated 19 cost of service study serve as a guide to inform the allocation of costs and design of 20 rates. Additionally, there are specific ratemaking requirements and methodologies that 21 perhaps Ms. Whited is not aware of which derive key data from properly classified 22 customer costs in the cost-of-service study. For example, the MMRC calculation forPage 47 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 45 of 52 1 determining the residential Rate 1 customer charge, designated per statute and 2 regulation, requires the use of the cost of a meter, among other customer related costs, 3 in its development. With regard to class cost of service (i.e., revenue) allocation, PURA 4 determines the ultimate allocation of revenue among classes, along with the portion of 5 such revenue attributable to customer charges and to demand charges (which are 6 assimilated through volumetric or demand charges, depending on the class). These 7 allocations do not match precisely to the cost-of-service study and further, the portion 8 of customer and demand revenue within each class do not match precisely the 9 respective customer and demand allocations of costs within the allocated cost-of- 10 service study. 11 Therefore, regarding AMI implementation, the Company disagrees with Ms. Whited’s 12 recommendation. The Company’s expectation is that AMI costs would properly be 13 classified as customer costs, and that capital costs and expenses associated with AMI 14 implementation would be collected from customers consistent with allocation of costs 15 allowed in this proceeding for distribution rates or another applicable rate mechanism. 16 The proposed allocation of AMI implementation costs to each class through the 17 PBMRP would be based on such authorized distribution rate revenue, which notably 18 includes both customer and demand components.Page 48 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 46 of 52 1 VI. OTHER RATE DESIGN 2 3 Q. Please describe the testimony regarding rate design submitted by Mr. Eben Perkins on behalf of the University of Connecticut. 4 A. Mr. Perkins advocates for a Connecticut CPT rate, relying on prior implementation of 5 a CPT at other utilities as a basis for carrying forward a similar proposal into this rate 6 case. 45 It is unclear whether he is a proposing a temporary or more permanent proposed 7 rate design. He also advocates for a change in the rate design itself without specifying 8 whether he is advocating for both such rate redesign and the option to participate in the 9 new rate, regardless of whether a customer ends up paying more or less due to their 10 success or failure to reduce load at the one hour of the month. Most importantly, Mr. 11 Perkins does not consider what costs may be shifted to other customers as a result. 12 The “fixed costs” that he discussed are a reminder that, in the context of the distribution 13 and transmission rates he is seeking to change, the rates we design are for charges to 14 customers for the recovery of fixed costs of the systems they utilize. 46 A change in 15 either distribution or transmission rate structures, especially for the rate classes Mr. 16 Perkins references, would directly implicate the prospect of cost shifting, both 17 intraclass and interclass, among the smaller customers that the Company provides 18 service to. For transmission services, the potential for cost shifting translates to other 19 utilities throughout ISO-NE, and may be shifting costs to CL&P as a result of CPT 45 Perkins at 31-38. 46 Perkins at 29-30.Page 49 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 47 of 52 1 customers in the other jurisdictions referenced by Mr. Perkins. 47 This cost shifting 2 would occur in terms of both cost allocation and the setting of rates for transmission 3 service. A reduction in transmission service load from, for example, a large C&I 4 customer, for one hour of a month would reduce the revenue for service that they take, 5 causing an under-recovery of revenue expected from the rate being charged. Under a 6 CTP rate, a customer could “chase” the hour of the ISO-NE transmission system peak 7 demand for RNS service in order to reduce their billing demand and thereby bypass the 8 obligation to pay for service they receive – shifting those costs to other, smaller 9 customers. It may be likely that such customer uses the transmission system in all 10 hours of the month but that one hour. Although their load in all other hours may be 11 equal to or greater than that of the peak hour load, they may pay little or nothing for 12 transmission service despite taking transmission service in all other hours. 13 Transmission owners construct, maintain and operate the transmission grid to provide 14 firm, reliable service to that customer. The costs of that system do not change – they 15 are fixed. The fixed cost of the transmission grid spread over a smaller load due to the 16 avoidance of demand for one hour will, all else being equal, increase transmission 17 service rates to all customers. 47 Id. at 19-20.Page 50 of 54
The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-RATES-REBUTTAL-1 November 18, 2026 Page 48 of 52 1 2 Q. How much cost shifting and what additional insights can we gain regarding existing CPT rates and participation? 3 A. Given the prevalence of the CPT rate at other utilities advertised by Mr. Perkins, it 4 would be informative to know the extent of avoided transmission charges by customers 5 participating in this type of rate mechanism, and magnitude and extent of service they 6 receive for all other hours. It would also be informative to understand the impacts of 7 cost shifting due strictly to changes in rate design, such as that contemplated by Perkins 8 for CL&P (e.g., due to a change in peak hours; the change in billing units during which 9 transmission rates apply). The answers to these and many other questions would be 10 important to explore in an investigation or consideration for developing such a rate 11 mechanism. 12 While Mr. Perkins is calling for an update to transmission rate design and time-of-use 13 periods, he is centrally focused on a retail CPT rate mechanism. 14 transmission service may be reduced for individual customers; however, the 15 complexity in their development and basis should be unwrapped and understood. It is 16 important to note, unlike the billing of demand charges that occur at the transmission 17 service level and as allocated down to rate classes and designed into rates, the 18 underlying costs of transmission service itself may not be reflected in these allocations 19 or design. The impact of single hour load reduction and avoided charges by an 20 individual retail customer translates to an increase in transmission rates and a shift in 21 who pays for that customer’s transmission service. This concern prompts several 22 questions that need to be addressed regarding the proposed CPT rate. For example, to Charges for
As listed on the current system
Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: EDWARD DAVIS, KIMBERLY R. PARSONS, AMPARO NIETO [26-05-10]