Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Files1

Search terms highlighted
Eversource rate increase is on 8 pages of the text below, highlighted. Go to the first matchClear highlighting
8 pages match
  1. Page 28 of 130

    James R. Dauphinais Page 26 III. RESPONSE TO CLF-SC WITNESS VELEZ 1 2 A. Mr. Velez’s Proposed Rate HP 3 Q PLEASE SUMMARIZE MR. VELEZ’S PROPOSED RATE HP. 4 A Mr. Velez proposes a new residential rate schedule, Rate HP, for customers with heat 5 pumps. During the winter months of November through March, Rate HP would reduce 6 the distribution energy charge by approximately 71% and the transmission service rate 7 by approximately 75% compared with Rate 1. Summer rates, generation rates and the 8 customer charge would remain at Rate 1 levels.97 All known existing heat pump 9 customers and all customers newly installing heat pumps would be automatically 10 enrolled.98 11 Q WHAT IS THE BASIS FOR MR. VELEZ’S PROPOSAL? 12 A Mr. Velez claims that fossil fuel-heated customers who install heat pumps are 13 “overcharged” by an average of $1,040 per year for distribution and transmission, 14 because their distribution and transmission charges under Rate 1 increase by about 15 $1,051 per year while, in his estimation, the incremental marginal distribution and 16 transmission costs caused by the heat pump load are only about $10 per year.99 17 Rate HP is designed to reduce the distribution and transmission revenue collected from 18 heat pump customers so that their incremental charges equal his estimate of their 19 incremental marginal cost.100 97 Velez Direct at 6, lines 15-23, 7, lines 1-2, and 81, lines 10-16. Id. at 7, lines 3-8. 99 Velez Direct at 20, lines 5-8, and 23, lines 2-10. 100 Id. at 81, lines 17-23, and 82, lines 1-3. 98 BRUBAKER & ASSOCIATES, INC.
  2. Page 29 of 130

    James R. Dauphinais Page 27 1 B. The Claimed “Overcharge” Is a Contribution to Embedded Costs 2 Q IS THE $1,040 PER YEAR THAT MR. VELEZ CHARACTERIZES AS AN 3 4 “OVERCHARGE” ACTUALLY AN OVERCHARGE? A No. CL&P’s rates are set to recover its embedded cost revenue requirement, which 5 consists predominantly of the fixed costs of facilities already in service. Mr. Velez 6 acknowledges that this existing infrastructure “does need to be paid for.”101 Marginal 7 cost, on the other hand, measures only the cost of serving additional load. Where the 8 system has spare capacity, the marginal cost of serving additional load will be well 9 below the embedded cost per unit. 10 embedded cost-based rates are overcharged. It means that their usage is contributing 11 to the recovery of existing fixed costs that would otherwise have to be recovered from 12 other customers. 13 Mr. Velez confirms the point. He agrees that the approximately $1,055 per year by 14 which the average fossil fuel-heated customer’s distribution and transmission charges 15 exceed its marginal cost before it installs a heat pump is that customer’s “contribution 16 to the embedded costs of the existing system,” and that his testimony “does not call 17 that contribution an overpayment.”102 Yet he contends that “incremental heat pump 18 load should not contribute to embedded T&D costs” at all.103 The same excess of 19 charges over marginal cost cannot be a legitimate contribution to fixed costs before a 20 customer installs a heat pump and an “overcharge” afterward. That does not mean that customers paying The $1,040 Mr. Velez calls an overcharge is that contribution. 21 CL&P has explained that keeping incremental heat pump load “priced above 22 the marginal cost of serving it” places “downward pressure on average rates for all 101 Velez Direct at 13, line 23, and 14, lines 1-2. CLF-SC Response to Data Request CIEC-4(b) and (c) of CIEC Set 2. 103 CLF-SC Response to Data Request CIEC-17(a) of CIEC Set 2. 102 BRUBAKER & ASSOCIATES, INC.
  3. Page 30 of 130

    James R. Dauphinais Page 28 1 customers over time” by “spreading fixed costs over a larger sales base.”104 That is a 2 benefit of load growth that is shared with all customers, not an inequitable 3 cross-subsidy. 4 Q 5 6 DOES CL&P’S MARGINAL COST OF SERVICE STUDY SUPPORT SETTING HEAT PUMP CUSTOMERS’ CHARGES AT MARGINAL COST? A No. Mr. Velez relies on CL&P’s Marginal Cost of Service (“MCOS”) study to conclude 7 that heat pump load causes near-zero winter distribution costs.105 CL&P, however, 8 presented that study “to be used as a guide for rate design.”106 CL&P’s class revenue 9 targets “are decided primarily on the basis of the Company’s allocated cost of service 10 study (ACOS).” The MCOS results are used only to ensure that each rate class pays 11 “at least the corresponding marginal costs of service.”107 That is the proper role of a 12 marginal cost study: to inform rate design and to serve as a floor. It should not 13 determine how embedded costs are allocated or how much of those costs any group 14 of customers pays. Rate HP departs from that role. It treats marginal cost as the full 15 measure of what heat pump load should pay for distribution and transmission, so that 16 load would make essentially no contribution to CL&P’s embedded costs. The Authority 17 should limit the use of the MCOS study to informing rate design, and should not use it 18 to allocate embedded costs or to exempt any customer’s load from contributing to them. 104 Velez Direct at 31, lines 15-17, and 60, lines 1-4 (quoting CL&P Response to Data Request CLF-003(a)). 105 Velez Direct at 20, lines 11-12. 106 CL&P Witness Nieto MCOS Direct (Exhibit CLP-MCOS-1) at 2, lines 13-15. 107 Id. at 6, lines 17-21. BRUBAKER & ASSOCIATES, INC.
  4. Page 31 of 130

    James R. Dauphinais Page 29 1 Q 2 3 HOW DOES RATE HP COMPARE WITH CL&P’S PROPOSED RATE 6 IN THIS RESPECT? A The two differ in three important ways. First, CL&P priced the Rate 6 winter block 4 “based on, but above marginal cost to ensure positive contribution to distribution costs.” 5 Rate HP would set incremental charges at Mr. Velez’s estimate of marginal cost. 6 Second, under Rate 6, “a customer must add new heat pump load not already included 7 in the underlying revenue requirement.” Rate HP would automatically enroll existing 8 heat pump customers whose load is already reflected in CL&P’s revenue requirement. 9 Third, under Rate 6, “[p]ricing for other components of service including transmission, 10 public benefits and supply are unchanged relative to Rate 1.” Rate HP would reduce 11 the winter transmission rate by 75%.108 12 Q 13 14 WHY DOES THE AUTOMATIC ENROLLMENT OF EXISTING HEAT PUMP CUSTOMERS MATTER? A For a customer that already has a heat pump, Rate HP would not attract any new load. 15 It would simply reduce the revenue collected from load that is already on CL&P’s 16 system and already contributing to its fixed costs. The Authority has recognized this 17 type of risk. In Docket No. 24-10-04, the Authority approved a load retention special 18 contract policy for UI that is limited to customers whose load is at risk of being lost, and 19 even then it expressed concern about free ridership. Under that policy, discounts are 20 negotiated on a case-by-case basis, are subject to the Authority’s approval, and are 21 subject to a price floor based on long-run marginal distribution cost.109 Rate HP would 22 provide marginal-cost pricing automatically to every enrolled heat pump customer, 23 without any showing that the discount is needed to cause or retain any load. 108 109 CL&P Response to Data Request OCC-475(a); Velez Direct at 6, line 20, through 7, line 8. Docket No. 24-10-04, October 28, 2025 Decision at 229-231. BRUBAKER & ASSOCIATES, INC.
  5. Page 32 of 130

    James R. Dauphinais Page 30 1 Q 2 3 HAS THE AUTHORITY ADDRESSED A SIMILAR QUESTION FOR INCREMENTAL COMMERCIAL AND INDUSTRIAL LOAD? A Yes. In approving UI’s EDR, the Authority required that revenue from incremental load 4 exceed the incremental cost to serve it and capped the discount at 50% of the projected 5 savings, so that “at least 50% of the benefit from the incremental or new load is 6 allocated to existing ratepayers.”110 Rate HP takes the opposite approach. By setting 7 the incremental distribution and transmission charges for heat pump load equal to its 8 estimated marginal cost, Rate HP would leave essentially none of that load’s 9 contribution to fixed costs for the benefit of other customers. 10 Q DOES MR. VELEZ’S RELIANCE ON MARGINAL COST SUPPORT RATE HP? 11 A No. I agree that distribution and transmission fixed costs are driven principally by peak 12 demands rather than by energy consumption. That principle governs how embedded 13 costs are classified and allocated among and within classes. It does not mean that 14 embedded costs can go unrecovered. The residential class’s share of CL&P’s revenue 15 requirement is determined through the ACOSS and revenue allocation, and does not 16 decline because some residential customers are placed on Rate HP. If heat pump 17 customers pay less, other customers must pay more. 18 intra-class issue within the residential class, CL&P’s marginal cost witness identifies 19 the appropriate remedy: rebalancing cost recovery within the class from usage charges 20 toward fixed charges.111 That remedy does not require any other class to make up 21 revenue. 110 111 Docket No. 22-08-08, August 25, 2023 Decision at 250-251. Nieto MCOS Direct at 4, lines 20-22, and 5, lines 1-7. BRUBAKER & ASSOCIATES, INC. To the extent there is an
  6. Page 33 of 130

    James R. Dauphinais Page 31 1 C. Rate HP Is Not Revenue Neutral 2 Q IS RATE HP DESIGNED TO BE REVENUE NEUTRAL? 3 A No. Mr. Velez confirms that Rate HP is not designed to be revenue neutral with respect 4 to the residential class as a whole,112 and he expressly rejects a revenue-neutral 5 design. He states that a seasonal design that lowers the winter rate but raises the 6 summer rate “merely shifts the overpayment between seasons, defeating the entire 7 purpose of a heat pump rate,” and that neither season’s rates should be set higher than 8 those in Rate 1.113 He also states that no heat pump customer would be made worse 9 off by being placed on Rate HP.114 Mr. Velez recognizes that a revenue-neutral 10 redesign of the retail transmission charge would involve “lowering it in winter and raising 11 it in summer,”115 and that a lower rate available to all customers “would create a 12 revenue shortfall under heavy enrollment.”116 However, his direct testimony does not 13 quantify the revenue shortfall Rate HP itself would create or identify who would pay it. 14 In discovery, he states that he considered how that shortfall would be recovered 15 between rate cases “but did not address it in [his] testimony.”117 16 Q HOW LARGE COULD THAT REVENUE SHORTFALL BE? 17 A Mr. Velez has now quantified it. He estimates that automatically enrolling the 18 approximately 55,000 existing heat pump customers who have received Energize CT 19 rebates, as he recommends, would reduce CL&P’s revenue by $39.8 million in 20 distribution and $17.4 million in transmission, or about $57.2 million in total, in the first 112 CLF-SC Response to Data Request CIEC-2(a) of CIEC Set 2. Velez Direct at 101, lines 6-17. 114 Id. at 95, lines 1-4. 115 Id. at 83, footnote 75. 116 Id. at 95, lines 14-16. 117 CLF-SC Response to Data Request CIEC-2(d) of CIEC Set 2. 113 BRUBAKER & ASSOCIATES, INC.
  7. Page 34 of 130

    James R. Dauphinais Page 32 1 rate year and by approximately the same amount every year thereafter.118 He agrees 2 that these customers’ load is already on CL&P’s system and already reflected in the 3 sales used to set rates in this proceeding, and that enrolling them in Rate HP would 4 produce no new load and no reduction in CL&P’s costs.119 5 therefore a pure revenue reduction. Mr. Velez estimates that recovering it solely from 6 the residential class would raise Rate 1 distribution and transmission charges by about 7 0.61¢ per kWh, or about $4.24 per month for the average residential customer not on 8 Rate HP.120 The $57.2 million is 9 Q WHO WOULD PAY THE SHORTFALL? 10 A Mr. Velez’s direct testimony does not say. In discovery, he states that it should be paid 11 by other residential customers, but he acknowledges that CL&P’s reconciling 12 mechanisms would not produce that result.121 13 $19.7 million per year of the distribution shortfall would be recovered from 14 non-residential classes through the RDM, and approximately $8.3 million per year of 15 the transmission shortfall through the TAC, each year until the next rate case.122 16 CL&P’s description of those mechanisms confirms this. Between rate cases, any 17 shortfall in distribution revenue relative to CL&P’s authorized revenue target would be 18 recovered through the RDM, and CL&P proposes that the RDM rate “be set at a flat 19 kWh rate across all rate classes.”123 Rate 39 and Rate 57 are both subject to the RDM 20 per-kWh charge.124 CL&P confirms that the RDM rate would be a single per-kWh rate 118 He estimates that approximately CLF-SC Response to Data Request CIEC-1(a) and (b) and CIEC-12(c) of CIEC Set 2. $39.8 million + $17.4 million = $57.2 million. 119 CLF-SC Response to Data Request CIEC-12(a) and (b) of CIEC Set 2. 120 CLF-SC Response to Data Request CIEC-3(c) and CIEC-6(c) of CIEC Set 2. 121 CLF-SC Response to Data Request CIEC-2(b) and (d) of CIEC Set 2. 122 Id. 123 Davis and Parsons Direct at 22, lines 16-21. 124 Exhibit CLP-RATES-3 at 87 and 109. BRUBAKER & ASSOCIATES, INC.
  8. Page 35 of 130

    James R. Dauphinais Page 33 1 applied to all rate classes, including Rate 39, Rate 57 and Rate 58.125 Based on current 2 billing determinants, Rate 1 bears only 38.8% of any RDM charge, while Rates 39, 57 3 and 58 together bear 13.7%.126 4 revenues billed to customers against CL&P’s transmission costs “on a fully reconciling 5 basis,” applies to all customers taking delivery service, and, as proposed, is determined 6 by dividing the transmission revenue requirement and any true-up by anticipated kWh 7 sales.127 8 requirement, including any true-up, among rate class groups in proportion to their 9 demands coincident with CL&P’s twelve monthly system peaks, and only then converts 10 each group’s share to a per-kWh rate.128 In other words, the distribution revenue that 11 Rate HP fails to collect from heat pump customers would be recovered from all 12 customers, including CIEC’s members, on a per-kWh basis, which falls most heavily 13 on high load factor industrial customers. The transmission revenue that Rate HP fails 14 to collect would likewise be recovered from all rate classes, including those in which 15 CIEC’s members take service, in proportion to their demands at CL&P’s monthly 16 system peaks. Similarly, the TAC reconciles the transmission In practice, however, CL&P first allocates the transmission revenue 17 CIEC’s members and other non-residential customers should not be required 18 to fund a discount whose stated purpose is to address what Mr. Velez characterizes as 19 a cross-subsidy “within the residential customer class.”129 Mr. Velez agrees. He states 20 that no portion of the revenue reduction should be recovered from customers outside 21 the residential class, and that he “would welcome” a requirement that it be recovered 125 CL&P Response to Data Request CIEC-048(b) and (d) (Table 2). 1.3% + 4.1% + 8.3% = 13.7%. 126 Id. 127 Exhibit CLP-RATES-3 at 186-187. 128 CL&P Response to Data Request UCONN-024(a)-(b), as referenced in CL&P Response to Data Request CIEC-049(a); CLF-SC Response to Data Request CIEC-2(d) and CIEC-8(a) of CIEC Set 2. 129 Velez Direct at 5, lines 10-13. BRUBAKER & ASSOCIATES, INC.
  9. Page 36 of 130

    James R. Dauphinais Page 34 1 solely from the residential class.130 That result, however, would require affirmative 2 action by the Authority, because, as Mr. Velez acknowledges, neither the RDM nor the 3 TAC “currently works this way.”131 By contrast, the seasonal TOU rate proposed by 4 OCC Witness Whited is designed to be revenue neutral with Rate 1.132 5 D. Winter Load Affects CL&P’s Transmission Costs 6 Q MR. VELEZ CONCLUDES THAT HEAT PUMP LOAD IN WINTER CAUSES 7 8 ESSENTIALLY NO TRANSMISSION COST. DO YOU AGREE? A No. Mr. Velez estimates marginal transmission cost by spreading an avoided 9 Pool Transmission Facility cost from the 2024 Avoided Energy Supply Components 10 study across hours based on the probability of the New England system peak, which 11 places that cost almost entirely in the summer.133 That is not how CL&P incurs the 12 transmission costs recovered through its retail transmission rates. As OCC Witness 13 Whited notes, ISO-NE allocates transmission costs based on monthly coincident peak 14 demand (“12CP”).134 Under a 12CP method, CL&P’s share of regional transmission 15 costs depends on its load at the time of the peak in each month, including each of the 16 five winter months in which Rate HP would reduce the transmission service rate by 17 75%. Heat pump load that increases CL&P’s monthly peak loads in the winter therefore 18 increases the transmission costs allocated to CL&P, and the TAC passes those costs 19 through to CL&P’s retail customers. CL&P confirms that its RNS and Local Network 20 Service charges are based on its network load at the time of each monthly peak, and 21 that each 1 MW increase in that load increased its 2026 RNS charges by 130 CLF-SC Response to Data Request CIEC-2(c), CIEC-3(b) and CIEC-16(b) of CIEC Set 2. CLF-SC Response to Data Request CIEC-2(d) of CIEC Set 2. 132 Whited Direct at 29, lines 6-13. 133 Velez Direct at 15, lines 5-10, and 16, lines 1-5. 134 Whited Direct at 34, lines 18-20. 131 BRUBAKER & ASSOCIATES, INC.
  10. Page 37 of 130

    James R. Dauphinais Page 35 1 $14,802 per month.135 Each MW of additional load at the monthly peaks of November 2 through March would therefore add approximately $74,000 per year in RNS charges 3 alone.136 CL&P also allocates its retail transmission revenue requirement among rate 4 classes using a 12CP allocator.137 Mr. Velez agrees that ISO-NE bills CL&P for 5 regional network service each month based on CL&P’s load in a single peak hour of 6 that month, “including in November through March,” and that if CL&P’s load in a 7 January peak hour rises, CL&P “pays a larger share” of regional transmission costs.138 8 He has not estimated the effect of heat pump adoption on CL&P’s November through 9 March monthly peak loads or on the transmission costs allocated to CL&P.139 10 Q 11 12 DOES THE MASSACHUSETTS PRECEDENT MR. VELEZ CITES SUPPORT HIS TRANSMISSION PROPOSAL? A No. According to the language Mr. Velez quotes, the Massachusetts Department of 13 Public Utilities directed National Grid and Unitil to calculate their winter transmission 14 charges “to recover the winter transmission revenue requirement over the adjusted 15 winter sales.”140 That is a cost recovery approach under which winter transmission 16 charges are designed to recover the transmission revenue requirement attributable to 17 the winter. It is not a reduction of winter transmission charges to an estimate of 18 marginal cost. Mr. Velez now concedes that the Massachusetts winter transmission 19 charges “were designed to recover a winter transmission revenue requirement” and 20 “were not set at an estimate of marginal transmission cost,” and that he is not aware of 135 CL&P Response to Data Request CIEC-050(a) and (c). $14,802 per month x 5 months = $74,010. 137 CL&P Response to Data Request UCONN-024(a)-(b), as referenced in CL&P Response to Data Request CIEC-049(a). 138 CLF-SC Response to Data Request CIEC-7(b) of CIEC Set 2. 139 CLF-SC Response to Data Request CIEC-7(c) of CIEC Set 2. 140 Velez Direct at 84, footnote 76. 136 BRUBAKER & ASSOCIATES, INC.

As listed on the current system

Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: James R. Dauphinais [26-05-10]

This filing on the current system (opens in a new tab)