  1. Page 12 of 70Match

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 10 of 68 1 III. Overview of Intervenors’ Witnesses’ Testimony 2 3 4 Q. Dr. Taylor, Ms. Griffin, and Ms. Wilson and Mr. Tully challenge aspects of LEI’s analyses and the Company’s proposed PBMRP. Would you please summarize your understanding of their questions and arguments? 5 A. Dr. Taylor questions LEI’s reliance on historical average productivity trends, the selection 6 of inputs and outputs, and argues that LEI’s sensitivity analyses are not sufficient. 5 7 However, using historical industry productivity trends to establish an X-Factor is a well- 8 established approach in North American utility regulation. LEI’s selection of inputs and 9 outputs is consistent with the purpose of measuring electric distribution productivity, the 10 costs covered by the Company’s proposed revenue adjustment mechanism, and the 11 availability of reliable and comparable data. Importantly, Dr. Taylor does not conduct an 12 independent electric distribution productivity study or present an alternative, consistently 13 specified methodology demonstrating that LEI’s approach is inappropriate. Rather, he 14 performs selected calculations using LEI’s reported results and published Bureau of Labor 15 Statistics (“BLS”) data. These calculations do not establish a more representative industry 16 OM&A productivity trend or provide a sound basis for replacing LEI’s proposed X-Factor. 17 Dr. Taylor reviews LEI’s annual OM&A PFP observations and identifies the 2019–2020 18 period as an atypical observation relative to the historical productivity trend, using an 19 interquartile-range analysis. By excluding this observation from LEI’s originally reported 20 annual OM&A PFP growth rates over 2005–2024, he calculates that average annual 21 industry OM&A PFP increases from −0.03% to +0.675%. He recommends that the Public 5 William O. Taylor, Direct Testimony on Behalf of Acadia Center, Docket No. 26-05-10 (Connecticut Public Utilities Regulatory Authority, October 21, 2026), 13–16, 21–22, 39–41.
  2. Page 13 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 11 of 68 1 Utilities Regulatory Authority (“Authority” or “PURA”) consider +0.675% as a floor for 2 the OM&A-only X-Factor. 6 3 Dr. Taylor further recommends additional sensitivity analyses involving alternative output 4 measures, expense classifications, weighting approaches, benchmark years, and capital- 5 related assumptions, including gross versus net plant values and capital-cost smoothing. 7 6 LEI recognizes the value of sensitivity testing when alternative specifications are supported 7 by a reasonable economic rationale and reliable data. However, Dr. Taylor does not 8 identify the specific labor costs or distribution expense accounts that should be included or 9 excluded, the alternative benchmark year or capital-cost smoothing methodology that 10 should be applied, or an alternative weighting scheme for calculating OM&A PFP. 11 Moreover, several of his suggested sensitivities concern capital productivity and would not 12 directly affect the OM&A PFP measure underlying the Company’s proposed X-Factor. 13 LEI has also already examined several relevant sensitivities, including alternative output 14 measure, study periods, regional sample, and other methodological assumptions. Dr. 15 Taylor does not demonstrate that his proposed additional specifications would produce a 16 more appropriate OM&A productivity estimate, let alone substantiate a higher X-Factor. 17 Dr. Tayor also throws out a number of irrelevant alternatives, without any substantiation 18 for their selection. In addition to his proposed +0.675% OM&A X-Factor floor, he 19 recommends a +0.457% BLS utilities multifactor productivity factor (“MFP”) if the 20 revenue cap applies to both OM&A and capital, proposes alternative X-Factor based on a 21 TFP of zero and −1.04%, and suggests using the 62nd percentile of capital productivity 22 instead of the industry average. He also reports a +0.678% BLS private-business 6 Taylor, Direct Testimony, 16–17, 21–23. 7 Taylor, Direct Testimony, 21-23.
  3. Page 14 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 12 of 68 1 productivity estimate as a comparator to the X-Factor. These figures are derived from 2 different industries, cost categories, productivity concepts, and methodologies. Dr. Taylor 3 does not demonstrate how these disparate measures can be reconciled into a consistent 4 productivity framework appropriate for the Company’s proposed PBMRP. In particular, 5 the BLS utilities measure encompasses activities beyond electric distribution, while the 6 private-business measure reflects industries with fundamentally different production 7 processes and input requirements. Neither is directly comparable to electric distribution 8 OM&A productivity. 9 Finally, he recommends consideration of a frontier analysis. 8 But he does not perform such 10 an analysis, nor does he acknowledge the well-recognized problems with such an analysis 11 experienced in other regulatory jurisdictions. 12 Ms. Griffin questions the OM&A-only I-X mechanism, and the adequacy of the Consumer 13 Dividend. 9 She favors the broader revenue cap structure contemplated in the RE01 PFD , 14 under which the indexed revenue cap would apply to the full base revenue requirement, 15 with a separate CT-Bar mechanism for incremental capital investment. Her principal 16 argument is that excluding capital from the indexed revenue cap weakens total-cost 17 containment incentives and could encourage the Company to favor capital investments 18 over operating solutions. 10 However, her proposed approach would not adequately address 19 the Company’s substantial capital investment requirements anticipated during the four- 20 year PBMRP term. As explained in the Company’s direct testimony, significant 21 investments will be necessary to replace aging infrastructure, maintain and improve 8 Taylor, Direct Testimony, 25–28, 35–38, 40. 9 Lindsay J. Griffin, Direct Testimony on Behalf of Acadia Center and Conservation Law Foundation, Docket No. 26-05-10 (Connecticut Public Utilities Regulatory Authority, October 21, 2026), 33–43, 67–70. 10 Griffin, Direct Testimony, 33–37.
  4. Page 15 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 13 of 68 1 reliability and resiliency, accommodate increasing demand, and modernize the distribution 2 system. Her argument also overlooks that the OM&A revenue allowance is determined 3 independently of actual operating expenses, creating an ongoing incentive for cost 4 containment. Capital recovery is also subject to separate limits, reconciliation, and 5 prudence review rather than being automatically reimbursed. 6 Ms. Griffin states that the Company’s originally proposed −0.03% X-Factor “points the 7 wrong way” because it would allow OM&A revenues to grow slightly faster than inflation 8 before application of the Consumer Dividend. 11 Ms. Griffin correctly describes the 9 mathematical effect of a negative X-Factor. However, this does not establish that the 10 proposed factor is inappropriate. The X-Factor reflects measured historical industry 11 OM&A productivity rather than a predetermined positive efficiency target. A negative 12 historical productivity estimate does not eliminate the Company’s incentive to control 13 actual operating costs. Moreover, the proposed 0.30% Consumer Dividend more than 14 offsets the negative X-Factor, producing a net adjustment of 0.29 percentage points below 15 inflation using LEI’s amended X-Factor of −0.01%. 16 Ms. Griffin also argues that LEI’s productivity study does not follow the RE01 PFD’s 17 proposed use of customer count, delivered energy, and peak demand as outputs. LEI used 18 customer count as it is the appropriate measure to calibrate the X-Factor for a revenue cap. 19 It is also a commonly used output measure in North American electric distribution 20 productivity studies, and it is consistently available and reflects the utility’s obligation to 21 maintain the distribution network and serve connected customers. LEI also examined 22 electricity sales as an alternative output measure. Using the amended dataset, the sales- 11 Griffin, Direct Testimony, 36–37, 67.
  5. Page 16 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 14 of 68 1 based sensitivity produces average annual OM&A PFP of approximately −0.97%, 2 compared with −0.01% using customer count. Thus, LEI’s preferred customer-based 3 specification results in a higher X-Factor than the sales-based alternative and is therefore 4 more conservative from the ratepayers’ perspective. LEI also does not consider annual 5 system peak demand an appropriate additional output measure for its TFP study, as it is 6 not necessarily consistent with the revenue-cap framework proposed by the Company. It 7 also does not align with localized loading conditions that drive distribution system 8 investment. Moreover, the available FERC Form 1 peak-demand data are incomplete for 9 the utilities and years covered by LEI’s Industry Study, and annual system peak demand is 10 sensitive to short-term weather and consumption fluctuations that may not reflect 11 underlying productivity changes. Furthermore, Ms. Griffin does not present her own 12 alternative productivity calculation incorporating all three measures, identify how they 13 should be combined and weighted, or demonstrate that the resulting estimate would be 14 more appropriate. 15 She also questions the use of an OM&A-specific composite inflation index rather than the 16 economy-wide GDP Price Index contemplated in the PFD. 12 Her argument overlooks the 17 fundamental principle that the inflation index and productivity factor must be appropriately 18 aligned with the costs covered by the revenue adjustment mechanism. Using an economy- 19 wide output-price index such as GDP-PI would require additional adjustments to account 20 for differences between economy-wide productivity and price changes and those 21 experienced by electric distribution utilities. Ms. Griffin also does not demonstrate why an 22 economy-wide inflation index would provide a more appropriate measure of the 12 Griffin, Direct Testimony, pp. 18–19, 35–37, 79.
  6. Page 17 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 15 of 68 1 Company’s OM&A input-price changes or explain how the corresponding productivity 2 factor should be adjusted to maintain methodological consistency. 3 Ms. Griffin argues that the proposed 0.30% Consumer Dividend is too low given LEI’s 4 findings that CL&P’s historical OM&A costs exceeded its econometric benchmark. 5 However, she appears to misunderstand that these historical benchmarking deviations 6 measure relative cost levels, and do not indicate the annual rate at which those differences 7 could reasonably and sustainably be reduced. Ms. Griffin also does not establish how the 8 observed cost differences should be translated into a different annual Consumer Dividend 9 or identify a substantiated alternative percentage. 10 Furthermore, Ms. Griffin believes that the proposed Consumer Dividend does not 11 adequately reflect CL&P’s relative inefficiency and proposes a tiered approach under 12 which less efficient utilities would receive higher Consumer Dividends. 13 However, she 13 does not specify the proposed performance thresholds, corresponding Consumer Dividend 14 percentages, or the resulting factor for CL&P. 15 Ms. Wilson and Mr. Tully prefer that PURA approve a one-year rate plan, notwithstanding 16 OCC’s express recognition in RE01 that a four-year MRP strengthens cost-containment 17 incentives and benefits ratepayers. 14 If a PBMRP is approved, they recommend a zero X- 18 Factor. They question the selection of output measures, treatment of unusual observations, 19 absence of formal structural-break or outlier testing, and use of historical results for a 13 Griffin, Direct Testimony, 69–70. 14 Connecticut Office of Consumer Counsel, Comments on the Revised Straw Proposal, Docket No. 21-05-15RE01 (March 26, 2025), p. 4, as summarized in the RE01 PFD, p. 9.
  7. Page 18 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 16 of 68 1 prospective adjustment. 15 However, several of the methodological alternatives they 2 identify have already been examined by LEI, as discussed above. 3 Ms. Wilson and Mr. Tully further argue that the separate F-Factor could encourage capital 4 investment over operating solutions or the capitalization of operating costs. However, 5 while they cite general concerns regarding capital expenditure bias, they provide no 6 company-specific evidence or quantitative analysis demonstrating that the proposed F- 7 Factor would lead to such outcomes. They acknowledge the OM&A cap’s operating- 8 efficiency incentive and the F-Factor’s recovery limits but question their adequacy and the 9 administrative requirements of annual capital reviews. 16 10 11 Q. What is your high-level response to the opinions expressed by the intervenors’ witnesses? 12 A. The intervenors’ witnesses appear to recognize the relevance of productivity evidence, 13 benchmarking, and efficiency incentive properties of the Company’s PBMRP. For 14 example, Ms. Wilson and Mr. Tully recognize that the OM&A revenue cap creates 15 incentives for operating efficiencies and that the Consumer Dividend allows customers to 16 share in expected efficiency gains. 17 The concerns they raise and questions they pose in 17 their testimonies reflect, in my opinion, the relative “newness” of PBR in Connecticut. In 18 the absence of established Connecticut precedents and practical experience implementing 19 PBR frameworks, the intervenors’ witnesses have drawn on alternative sources of 20 information and requested various additional tests, some of which may not be directly 21 applicable to the Company’s proposed PBMRP or provide meaningful guidance for 15 Gennelle Wilson and Oliver Tully, Direct Testimony on Behalf of the Office of Consumer Counsel, Docket No. 26-05-10 (Connecticut Public Utilities Regulatory Authority, October 21, 2026), 10, 35–43. 16 Wilson and Tully, Direct Testimony, 17–26. 17 Wilson and Tully, Direct Testimony, 22, 43–45.
  8. Page 19 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 17 of 68 1 determining its parameters. I also note that none of the intervenors’ witnesses presented a 2 comprehensive, independently estimated study of U.S. electric distribution industry 3 productivity that would provide a rigorous and comparable alternative to the analysis 4 presented in my direct testimony. Moreover, several of their proposed alternatives are not 5 sufficiently developed or supported by the analysis necessary to establish how they should 6 be implemented or whether they would produce more appropriate results. Section IV 7 addresses the critiques of the proposed regulatory framework, including the I-Factor and 8 X-Factor alignment, capital recovery and incentives, the BLS comparisons, and departures 9 from RE01. Section V addresses arguments on LEI’s methodology, sensitivity analyses, 10 study period, unusual observations, and output measures. Section VI addresses the 11 interpretation of benchmarking evidence, the basis for the initial Consumer Dividend, and 12 its subsequent operation and customer impacts.
  9. Page 20 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 18 of 68 1 IV. Response to Critiques of the Proposed PBR Framework A. Interpretation and Validity of Negative TFP 2 3 4 Q. Dr. Taylor and Ms. Griffin are concerned with a negative TFP/negative X-Factor. 18 How would you respond to their concerns? 5 A. A negative productivity trend is not abnormal, nor does it necessarily indicate inefficiencies 6 or mute a utility’s incentive to control OM&A costs. 7 A negative TFP/PFP can be a valid empirical result and does not, by itself, indicate an error 8 in the methodology or establish that an industry or utility is inefficient. It simply means 9 that measured input quantities increased more rapidly than measured output over the period 10 examined. As explained in my direct testimony, this outcome is entirely possible, 11 especially when the sector is being asked to expand spending and investment to serve 12 customers under an index-based productivity calculation. 19 13 Many other TFP studies in recent years have concluded that the electric distribution utility 14 has been experiencing a negative productivity trend, as discussed in my testimony. 20 15 Electric distribution utilities may experience negative measured total productivity even 16 while undertaking prudent and necessary investments. For example, infrastructure- 17 replacement or modernization expenditures may increase capital inputs without a 18 corresponding increase in customer count. Capital inputs affect capital productivity and 19 total TFP; they do not directly enter the OM&A PFP calculation. For OM&A PFP, the 20 relevant corollary is the need for increased operating and maintenance expenditure in the 21 underlying FERC Form 1 accounts. For example, Account 593 (Maintenance of Overhead 18 Taylor, Direct Testimony, 37–38; Griffin, Direct Testimony, 33–37. 19 Frayer, Direct Testimony, 44–46. 20 Frayer, Direct Testimony, 1, 43.
  10. Page 21 of 70

    The Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-REBUTTAL-1 November 18, 2026 Page 19 of 68 1 Lines), has been the principal driver of sustained distribution maintenance cost increases, 2 alongside utility-specific increases in Account 598 (Maintenance of Miscellaneous 3 Distribution Plant), and Account 925 (Injuries and Damages). These expenditure pressures 4 are consistent with documented increases in vegetation management, risk-informed 5 inspections and repairs, wildfire mitigation, storm restoration, and associated liability 6 costs. 7 The incentive to improve operating efficiency arises from the Company’s opportunity to 8 manage its actual covered OM&A expenditures below the predetermined revenue 9 allowance during the PBMRP term. This incentive does not depend on the historical 10 productivity estimate (and X-Factor) being a substantive positive value. For example, 11 assume a base-year OM&A revenue allowance of $100 million, an annual inflation factor 12 of 2.0%, and an X-Factor of negative 0.5%. Under these assumptions, and assuming no 13 other adjustments, the predetermined OM&A revenue allowance for the following year 14 would be $102.5 million. If the Company improves its operating efficiency and limits its 15 actual covered OM&A expenditures to $100.5 million, it would achieve $2 million in 16 savings relative to the predetermined allowance. Thus, even with a negative X-Factor, the 17 Company would have an incentive to improve operating efficiency because reducing actual 18 expenditures below the predetermined allowance creates an opportunity to increase 19 earnings, subject to any applicable earnings-sharing provisions.
22 pages match
2 pages match

As listed on the current system

Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: Julia Frayer [26-05-10]