    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 25 of 102 Average growth is the more common method of measuring the study-period TFP growth rate and has been used in previous studies presented before the Massachusetts Department of Public Utilities. 37 The preference for this method can be attributed to the fact that it calculates the annual growth rates for the TFP index values throughout the study period. 36F 2.6 Primary sources of data The data gathering process was a fundamental and critical step that required a significant amount of effort in conducting an industry TFP study. The primary data source for this TFP Study included the Federal Energy Regulatory Commission (“FERC”) Form 1. LEI also relied on data from the US Bureau of Economic Analysis (“BEA”), the BLS, the Federal Reserve Economic Data (“FRED”), Moody's, Institute of Taxation and Economic Policy, U.S. Department of the Treasury, S&P Capital IQ, and the Internal Revenue Service. For this Industry TFP Study, LEI sought to include as many electric distribution companies (“EDCs”) as possible, subject to the availability and quality of data over the entire study period. Beginning with a population of 144 investor-owned EDCs operating in the United States as of 2024, LEI selected those EDCs with sufficiently complete and reliable data spanning 1988 through 2024. Although the TFP growth analysis covers the period from 2005 through 2024, the benchmark year was established as 1988 to enable the estimation of capital input quantities, which requires historical investment data dating back to the benchmark year. Where appropriate, LEI interpolated isolated missing observations when data were unavailable for a single year but were available for the immediately preceding and following years. Applying these selection criteria resulted in a final sample of 88 EDCs across 48 states. 38 This sample provides a robust representation of the U.S. electric distribution industry, encompassing both small and large 37F 37 For example, the average growth approach was used in the TFP study for National Grid in both D.P.U. 23-150 and D.P.U. 26-50 in Massachusetts. Mark E. Meitzen, Ph.D. and Nicholas A. Crowley, MS, Christensen Associates. Pre-Filed Direct Testimony of Mark E. Meitzen, Ph.D. and Nicholas A. Crowley, MS, Performance-Based Ratemaking Panel, Massachusetts Electric Company and Nantucket Electric Company each d/b/a National Grid, D.P.U. 23-150, Exhibit NG-MM-NC-1. November 16, 2023. Nicholas A. Crowley and Daniel P. McLeod, Christensen Associates Energy Consulting. Pre-Filed Joint Direct Testimony of Nicholas A. Crowley, CFA and Daniel P. McLeod, Ph.D., Total Factor Productivity Study, Cost Benchmarking Study, and Performance-Based Regulation Framework Evaluation, Boston Gas Company d/b/a National Grid, D.P.U. 26-50, Exhibit NG-CAEC-1. January 16, 2026. 38 A sample of 88 firms is consistent with other TFP studies for U.S. electric distribution sector. For instance, Public Service Company of New Hampshire (DE 24-070) used 87 utilities and NSTAR Electric and Western Massachusetts Electric Company (MA DPU 22-22) used 65 utilities. [Sources: Mark B. Kolesar, Kolesar Buchanan & Associates Limited. Principle Report on Behalf of Public Service Company of New Hampshire d/b/a Eversource Energy, Docket No. DE 24-070, New Hampshire Public Utilities Commission. June 10, 2024. Meitzen, Mark E. and Crowley, Nicholas A. Pre-Filed Direct Testimony of Mark E. Meitzen, Ph.D. and Nicholas A. Crowley, MS. Exhibit ES-PBR/TFP-1. Massachusetts Department of Public Utilities Docket No. D.P.U. 22-22. January 14, 2022.] London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  2. Page 28 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 26 of 102 utilities, diverse customer compositions, urban, suburban, and rural service territories, and all BLS regions. 39 38F 39 A list of utilities included in LEI’s Industry TFP Study is shown in Appendix A (Section 7). London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  3. Page 29 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 27 of 102 3 Measuring inputs and outputs Selecting the appropriate inputs and outputs is a crucial part of a TFP study. Intuitively, selected inputs and outputs would be those that most accurately represent the physical process behind the distribution of electricity. At the most basic level, inputs to a TFP study should reflect the quantity of capital deployed 40 and the quantity of OM&A costs. In other words, all major inputs that impact the cost of providing electric distribution service. Together, these inputs form a twoinput model formulation. Output should reflect key products or services. For this TFP Study, LEI determined it would be best to use a single output metric, namely the total number of customers served by the distribution network of each EDC, as discussed further below. For comprehensiveness, LEI also tested electricity sales as an alternative output metric, as discussed further in Appendix B (see Section 8). 39F 3.1 Overview of Inputs to the TFP model The inputs were estimated based on monetary data taken from the annual financial reports and regulatory filings. LEI primarily relied on data at the operating subsidiary level from FERC Form 1 filings, which is compiled by a third-party data provider (S&P Global Market Intelligence). When data was missing and not available directly through the S&P Global Market Intelligence database, LEI conducted additional research (including outreach to state regulatory bodies and/or the EDCs and manually inputted the data from FERC Form 1). The conversion of financial asset data and OM&A cost data into capital quantities and OM&A quantities, respectively, involved several steps that are described further below. 3.2 OM&A input in the TFP model OM&A inputs reflect the non-capital related expenses that apply to the electric distribution business and associated with sales, distribution customer service, customer account, and administration and general (“A&G”) expense categories reported in EDCs’ FERC Form 1. 41 A&G expenses are reported on a corporate basis and not solely for the distribution business, so for the purposes of this Study, LEI considered only a proportion of A&G expenses. This proportion was determined for each EDC and year by calculating the share of distribution assets relative to total plant in service. 40F Cost categories that are not directly relevant to physical productivity of the distribution function of EDCs were excluded. For example, supply costs and/or fuel procurement is generally treated as a pass-through cost, and not part of the distribution PBR rate contemplated by PURA. In 40 LEI used a monetary approach for estimating capital quantities and have assumed a One Hoss Shay physical depreciation profile. A detailed discussion of this is found in Section 4.1.3.2. 41 FERC Form 1. Line No. 46. Title of Schedule Electric Operation and Maintenance Expenses. Reference Page No. 320. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  4. Page 30 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 28 of 102 addition, LEI excluded FERC Account 908 (Customer Assistance Expenses) from the Industry TFP Study because the objective of the analysis is to measure productivity in the provision of electric distribution service. Account 908 primarily includes expenditures associated with customer assistance and public policy programs, including energy efficiency, demand-side management, customer education, and related activities. These expenditures are largely driven by legislative or regulatory requirements rather than the utility's efficiency in operating and maintaining the electric distribution system. Moreover, the level of these expenditures varies considerably across jurisdictions due to differences in state policy objectives rather than differences in distribution productivity. Including Account 908 would therefore introduce policydriven variation into the TFP analysis and could bias measured productivity trends downward as customer assistance programs have expanded over time. Distribution expenses are the largest share of total OM&A expenses, averaging 46% per year, followed by the allocated A&G expenses, which account for another 31% of total OM&A costs at the industry aggregate level. Figure 9 shows the breakdown of the OM&A expense categories recorded across all 88 EDCs in the TFP Study from 2005 to 2024. The aggregate total of OM&A costs in nominal terms (not yet converted to input quantities) for the 88 EDCs in the sample grew at an average rate of 3.01% per year over the TFPs study period (2005-2024). LEI recognizes that OM&A expenditures will include labor as well as non-labor inputs. Therefore, OM&A expenditures will be affected by different inflation pressures; LEI constructed a customized price index that accounts for both labor costs and non-labor costs for purposes of deflating the OM&A expenditures and converting the spending levels into unit measures of input. LEI used the BLS Utilities Employment Cost Index (“ECI”) for Total Compensation 42 as the labor cost index and the BEA’s economy-wide GDP-FSDP as the non-labor cost index. 43 The BEA explains that GDP-FSDP measures prices paid by domestic purchasers across all economic sectors of the economy. Electric distribution utilities procure both domestically produced and imported materials, equipment, and services to support their operations, the GDP-FSDP provides a more representative measure of the inflation experienced in utility input purchases than other variations of inflation measures based on GDP. The ECI and GDP-FSDP indices are combined based on the non-labor and labor cost shares for each individual EDC. The cost shares for each EDC were determined by dividing the salaries and wages reported in FERC Form 1 for sales, 41F 42F 42 Bureau of Labor Statistics. ECI, total compensation, private industry workers, by occupation and industry group, seasonally adjusted, current dollar index - Utilities (CIS2014400000000I). 2026. 43 The BEA NIPA Handbook (Chapter 8 on Net Exports) explains that final sales of domestic product less net exports represents the market value of final goods and services purchased by U.S. firms, regardless of where those goods and services are produced. Sources: U.S. Bureau of Economic Analysis. Final Sales to Domestic Purchasers (Glossary). <https://www.bea.gov/help/glossary/final-sales-domestic-purchasers>, and U.S. Bureau of Economic Analysis. NIPA Handbook. Chapter 8, "Net Exports of Goods and Services," pp. 8-2 to 8-3 <https://www.bea.gov/resources/methodologies/nipa-handbook/pdf/chapter-08.pdf> London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  5. Page 31 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 29 of 102 distribution customer service, customer account, and A&G expense categories 44 by the OM&A expenses for the same respective expense categories. 43F Figure 9. Reported OM&A costs of the 88 EDCs in LEI’s TFP study (nominal $) 35,000,000 OM&A costs (000s, nominal) 30,000,000 25,000,000 20,000,000 15,000,000 10,000,000 5,000,000 - 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 A&G Customer Service Customer Account Distribution Sales Source: FERC Form 1. Line No. 46. Title of Schedule Electric Operation and Maintenance Expenses. Reference Page No. 320. Figure 10 shows that labor costs, measured by the ECI, have grown much faster than general prices measured by the GDP-FSDP since 1988. Because the customized OM&A price index blends the two based on each individual utilities labor share, it sits between them: the higher the labor share of OM&A costs, the more closely the customized index tracks the faster-growing ECI. The sharp rise after 2020 reflects the post-pandemic acceleration in both labor costs and broader inflation, with the customized index increasing especially where labor makes up a meaningful share of OM&A. 44 FERC Form 1. Line No. 55. Title of Schedule Distribution of Salaries and Wages. Reference Page No. 354. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  6. Page 32 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 30 of 102 Figure 10. Average input price index for OM&A 1988-2024 of the 88 EDCs 4.00 3.50 Index (1988=1) 3.00 2.50 2.00 1.50 1.00 0.50 0.00 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014 2016 2018 2020 2022 2024 GDP-FSDP ECI OM&A price index Source: Bureau of Labor Statistics. ECI, total compensation, private industry workers, by occupation and industry group, seasonally adjusted, current dollar index - Utilities (CIS2014400000000I). 2026. FRED. Implicit price deflator for final sales to domestic purchasers. 2026 Note: This is illustrative because individual price indices were used for each of the 88 companies in the sample based on their unique labor and non-labor proportions. 3.3 Capital input quantity LEI employed the monetary approach for calculating the capital input quantity for the EDCs. The calculation of the capital input quantity under a monetary approach centers around an estimate of the real capital stock of each EDC. This capital stock equals $257 billion (1988 $) in 2024 and includes a mix of electric distribution assets classified under the following categories reported in EDCs’ FERC Form 1: 45 structures and improvements, station equipment, computer hardware, computer software, communication equipment, poles, towers, and fixtures, overhead conductors and devices, underground conduit, underground conductors and devices, line transformers, services, meters, installations on customer premises, leased property on customer premises, and street lighting and signal systems, asset retirement costs for distribution plant. 44F 45 FERC Form 1. Line No. 16. Title of Schedule Electric Plant in Service. Reference Page No. 204. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  7. Page 33 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 31 of 102 For properly measuring the capital input quantity for a TFP study, it is not possible to simply take capital expenditures from financial data and use that as proxy. Capital expenditures may be incurred in a specific year but by definition the associated asset or piece of equipment will provide services for multiple years. Moving from financial to physical capital expenditure data is discussed in the subsections below. 3.3.1 Method for estimating the capital input quantity There are two approaches for calculating the capital input quantity: (i) a physical or direct approach, and (ii) a monetary or indirect approach. The advantage of the monetary approach is that the monetary value of the utility’s capital equipment is aggregated using monetary values from the financial records of the firms as the unifying element. Thus, the monetary approach allows for consideration of various capital assets into one capital input quantity. The monetary method also directly accounts for the magnitude of improvements made to capital assets from time to time. The shortcoming of the monetary method is that financial data on capital spending is typically not reported on a disaggregated basis, for each piece of equipment. EDCs normally only report the change in asset value (gross book value) for their entire stock of assets. The values of the new asset are added (or subtracted, when an asset is retired) based on its original historical cost at the time of the acquisition, and therefore the gross book value mixes assets acquired over different time periods (which makes it challenging to ascertain a “real dollar” value). Furthermore, the financial data typically does not get adjusted for the physical condition of the capital equipment, which is important to capture in a TFP study. Thus, one must apply exogenous assumptions regarding the physical deterioration of the capital stock over time under the monetary approach. The physical approach has several advantages if a metric could be identified that comprehensively and accurately describes the capital assets of an EDC and the services that such capital assets provide in relation to the distribution business of the EDC. If such a measure were available, it would not need to be further manipulated (for example, one would not need to deflate/inflate historical asset value) and presumably, it could reflect the physical capability directly (so then no further assumptions would need to be made as to physical deterioration or depreciation of the capital employed). However, such a measure does not exist for EDCs in the U.S., as there is no single measure reported by EDCs that uniformly and comprehensively estimates how different capital pieces of equipment and assets that an EDC may deploy contributes to the distribution services that an EDC provides for its customers. For this reason, LEI relied on the monetary approach. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  8. Page 34 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 32 of 102 3.3.2 Physical depreciation of capital under the monetary approach The monetary approach requires assumptions regarding the physical depreciation of the capital stock over time. Practitioners use three physical deprecation or decay profiles most frequently: geometric, hyperbolic, and OHS (these are illustrated in Figure 11). It is helpful to understand the basic characteristics of each profile: • One-Hoss Shay: An asset is assumed to retain its full efficiency over its entire lifetime. In other words, its productive capability is not correlated with time. The assets’ productive capability drops to zero at the end of its lifetime (it is fully consumed at the end of its last service year). An incandescent lightbulb is a good example of the OHS pattern of capital consumption—it is equally bright every single time it is turned on, except the last time when it is burnt out. Distribution poles are broadly analogous: once installed, a pole generally performs the same basic function of supporting conductors and associated equipment throughout its service life, until it is replaced because it is no longer considered sufficiently reliable or safe. The OHS approach assumes the asset’s physical ability to provide services does not deteriorate with age. However, the OHS approach does not preclude including retirement of assets, if an asset is damaged or no longer providing its intended services even if it has not reached the end of its useful life. 46, 47 45F 46F • Hyperbolic depreciation: The asset’s loss of productive efficiency is gradual at first but accelerates as the asset ages, producing a concave age-efficiency profile. The shape of the profile is governed by the beta parameter: a higher beta places more weight on later-life efficiency retention and therefore approaches an OHS pattern, while a lower beta implies faster efficiency loss earlier in the asset’s life. OHS can be viewed as a limiting or special case of the hyperbolic family, where the asset retains full productive efficiency until the end of its service life and then drops to zero. Hyperbolic depreciation does not use retirements data and instead uses the hyperbolic profile to depreciate capital assets over time. • Geometric decay: Under this profile, for each period of time, the asset is assumed to lose a fixed percentage of the productivity of the previous period. The assets therefore experience substantial losses of efficiency early in its lifetime but retains a long tail of low levels of efficiency toward the end of its life (a convex profile). A mailing list of customers 46 Retirements are the original book cost of utility plant taken out of service and removed from plant-in-service, not the cash cost of removing it or the replacement cost of the new asset. FERC separately defines cost of removal as the cost of demolishing, dismantling, tearing down, or otherwise removing electric plant. 47 ECFR. PART 101—UNIFORM SYSTEM OF ACCOUNTS PRESCRIBED FOR PUBLIC UTILITIES AND LICENSEES SUBJECT TO THE PROVISIONS OF THE FEDERAL POWER ACT. 2026. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  9. Page 35 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 33 of 102 follows a geometric depreciation in productivity because each address has the same chance of becoming unusable in any given period. The list will depreciate in productivity as people change jobs, abandon accounts, or unsubscribe. Like hyperbolic depreciation, geometric depreciation does not use retirements data and instead retires capital using the geometric depreciation profile. Figure 11. Capital asset (with useful service life of 35 years) depreciation profiles 1 Physical depreciation profile 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 5 10 15 20 25 30 35 Useful asset life Hyperbolic Geometric One-Hoss Shay LEI ultimately determined OHS to be the most appropriate physical depreciation method for this industry study, based on two main factors. Firstly, the expected productivity profile of capital EDC assets matches OHS the closest out of the three, with full efficiency until the end of life. The OHS profile also allows us to consider retirements of capital reported by the utilities and therefore take into account explicitly when certain equipment is retired because it can no longer provide services. A hyperbolic decay profile may be considered a close second although it requires certain assumptions for which data is not readily available. 48 These assumptions are discussed in detail 47F 48 The hyperbolics sensitivity uses an estimated hyperbolic depreciation curve to depreciate assets over the course of the assumed economic life of electric distribution capital (35 years). However, we do not know how old the initial capital asset base is for each EDC. LEI assumes that the initial capital asset base is halfway through its useful life. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  10. Page 36 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 34 of 102 in Appendix C (Section 9.1). Therefore, LEI performed a sensitivity analysis using a hyperbolic decay profile, which is documented in Appendix C (see Section 9). A geometric decay profile is unrealistic for representing physical depreciation of capital used by EDCs. A geometric decay profile is less appropriate for modelling the physical depreciation of EDC capital because it assumes that an asset loses a constant proportion of its productive capacity in every period, including relatively large losses early in its service life. This does not align well with the observed performance of many long-lived distribution assets, such as poles, overhead conductors, underground cable, transformers, and related line equipment. In practice, these assets generally remain in place and continue to provide the service for which they were installed until they are replaced, retired, or failed. While maintenance needs and failure risk may increase with age, the asset’s productive capability typically does not decline smoothly at a constant geometric rate each year. For this reason, geometric depreciation can overstate the loss of service potential in the earlier years of an EDC asset’s life and understate the “in-service until replacement” nature of much distribution plant. 3.3.3 Service life of capital under the monetary approach A 35-year average service life (“ASL”) for electric distribution assets was estimated through an empirical asset turnover analysis drawing on FERC Form 1 data for a broad sample of U.S. electric utilities. The cumulative sum of annual distribution plant retirements across the sample from 1989 through 2024 totaled approximately $88.6 billion, a figure that closely approximates the gross book value of distribution plant in service recorded at the end of 1988, which stood at approximately $88.7 billion. The convergence of these two figures implies that the industry required roughly 36 years to retire an asset base equivalent to its starting value, yielding an empirical estimate of the average service life in that range. Rounding to the nearest standard interval, a 35-year ASL was determined to represent a reasonable and appropriate estimate for use in the TFP analysis. 3.3.4 Deriving the capital input quantity LEI obtained the quantity of capital stock using the perpetual inventory equation, which has been adopted in numerous TFP studies used in ratemaking globally. 49 To calculate the capital stock in the current year (Kt), the perpetual inventory equation takes the end of year capital stock (gross book value) from the previous year (Kt-1) and adds in the gross book value of new additions (I) and deducts the gross book value of retirements (R) in year t. The new additions and retirement data were collected from FERC Form 1. 50 However, because the equation is incorporating the monetary value of assets of different vintages (and therefore in nominal dollars from different 48F 49F 49 This approach has been used in TFP studies that were ultimately accepted in Alberta, Australia, the UK, Massachusetts, New Hampshire, and Ontario. 50 FERC Form 1. Line No. 16. Title of Schedule Electric Plant in Service. Reference Page No. 204. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
2 pages match

As listed on the current system

Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: Julia Frayer [26-05-10]

This filing on the current system (opens in a new tab)