    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 29 of 102 distribution customer service, customer account, and A&G expense categories 44 by the OM&A expenses for the same respective expense categories. 43F Figure 9. Reported OM&A costs of the 88 EDCs in LEI’s TFP study (nominal $) 35,000,000 OM&A costs (000s, nominal) 30,000,000 25,000,000 20,000,000 15,000,000 10,000,000 5,000,000 - 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 A&G Customer Service Customer Account Distribution Sales Source: FERC Form 1. Line No. 46. Title of Schedule Electric Operation and Maintenance Expenses. Reference Page No. 320. Figure 10 shows that labor costs, measured by the ECI, have grown much faster than general prices measured by the GDP-FSDP since 1988. Because the customized OM&A price index blends the two based on each individual utilities labor share, it sits between them: the higher the labor share of OM&A costs, the more closely the customized index tracks the faster-growing ECI. The sharp rise after 2020 reflects the post-pandemic acceleration in both labor costs and broader inflation, with the customized index increasing especially where labor makes up a meaningful share of OM&A. 44 FERC Form 1. Line No. 55. Title of Schedule Distribution of Salaries and Wages. Reference Page No. 354. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  2. Page 32 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 30 of 102 Figure 10. Average input price index for OM&A 1988-2024 of the 88 EDCs 4.00 3.50 Index (1988=1) 3.00 2.50 2.00 1.50 1.00 0.50 0.00 1988 1990 1992 1994 1996 1998 2000 2002 2004 2006 2008 2010 2012 2014 2016 2018 2020 2022 2024 GDP-FSDP ECI OM&A price index Source: Bureau of Labor Statistics. ECI, total compensation, private industry workers, by occupation and industry group, seasonally adjusted, current dollar index - Utilities (CIS2014400000000I). 2026. FRED. Implicit price deflator for final sales to domestic purchasers. 2026 Note: This is illustrative because individual price indices were used for each of the 88 companies in the sample based on their unique labor and non-labor proportions. 3.3 Capital input quantity LEI employed the monetary approach for calculating the capital input quantity for the EDCs. The calculation of the capital input quantity under a monetary approach centers around an estimate of the real capital stock of each EDC. This capital stock equals $257 billion (1988 $) in 2024 and includes a mix of electric distribution assets classified under the following categories reported in EDCs’ FERC Form 1: 45 structures and improvements, station equipment, computer hardware, computer software, communication equipment, poles, towers, and fixtures, overhead conductors and devices, underground conduit, underground conductors and devices, line transformers, services, meters, installations on customer premises, leased property on customer premises, and street lighting and signal systems, asset retirement costs for distribution plant. 44F 45 FERC Form 1. Line No. 16. Title of Schedule Electric Plant in Service. Reference Page No. 204. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  3. Page 33 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 31 of 102 For properly measuring the capital input quantity for a TFP study, it is not possible to simply take capital expenditures from financial data and use that as proxy. Capital expenditures may be incurred in a specific year but by definition the associated asset or piece of equipment will provide services for multiple years. Moving from financial to physical capital expenditure data is discussed in the subsections below. 3.3.1 Method for estimating the capital input quantity There are two approaches for calculating the capital input quantity: (i) a physical or direct approach, and (ii) a monetary or indirect approach. The advantage of the monetary approach is that the monetary value of the utility’s capital equipment is aggregated using monetary values from the financial records of the firms as the unifying element. Thus, the monetary approach allows for consideration of various capital assets into one capital input quantity. The monetary method also directly accounts for the magnitude of improvements made to capital assets from time to time. The shortcoming of the monetary method is that financial data on capital spending is typically not reported on a disaggregated basis, for each piece of equipment. EDCs normally only report the change in asset value (gross book value) for their entire stock of assets. The values of the new asset are added (or subtracted, when an asset is retired) based on its original historical cost at the time of the acquisition, and therefore the gross book value mixes assets acquired over different time periods (which makes it challenging to ascertain a “real dollar” value). Furthermore, the financial data typically does not get adjusted for the physical condition of the capital equipment, which is important to capture in a TFP study. Thus, one must apply exogenous assumptions regarding the physical deterioration of the capital stock over time under the monetary approach. The physical approach has several advantages if a metric could be identified that comprehensively and accurately describes the capital assets of an EDC and the services that such capital assets provide in relation to the distribution business of the EDC. If such a measure were available, it would not need to be further manipulated (for example, one would not need to deflate/inflate historical asset value) and presumably, it could reflect the physical capability directly (so then no further assumptions would need to be made as to physical deterioration or depreciation of the capital employed). However, such a measure does not exist for EDCs in the U.S., as there is no single measure reported by EDCs that uniformly and comprehensively estimates how different capital pieces of equipment and assets that an EDC may deploy contributes to the distribution services that an EDC provides for its customers. For this reason, LEI relied on the monetary approach. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  4. Page 34 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 32 of 102 3.3.2 Physical depreciation of capital under the monetary approach The monetary approach requires assumptions regarding the physical depreciation of the capital stock over time. Practitioners use three physical deprecation or decay profiles most frequently: geometric, hyperbolic, and OHS (these are illustrated in Figure 11). It is helpful to understand the basic characteristics of each profile: • One-Hoss Shay: An asset is assumed to retain its full efficiency over its entire lifetime. In other words, its productive capability is not correlated with time. The assets’ productive capability drops to zero at the end of its lifetime (it is fully consumed at the end of its last service year). An incandescent lightbulb is a good example of the OHS pattern of capital consumption—it is equally bright every single time it is turned on, except the last time when it is burnt out. Distribution poles are broadly analogous: once installed, a pole generally performs the same basic function of supporting conductors and associated equipment throughout its service life, until it is replaced because it is no longer considered sufficiently reliable or safe. The OHS approach assumes the asset’s physical ability to provide services does not deteriorate with age. However, the OHS approach does not preclude including retirement of assets, if an asset is damaged or no longer providing its intended services even if it has not reached the end of its useful life. 46, 47 45F 46F • Hyperbolic depreciation: The asset’s loss of productive efficiency is gradual at first but accelerates as the asset ages, producing a concave age-efficiency profile. The shape of the profile is governed by the beta parameter: a higher beta places more weight on later-life efficiency retention and therefore approaches an OHS pattern, while a lower beta implies faster efficiency loss earlier in the asset’s life. OHS can be viewed as a limiting or special case of the hyperbolic family, where the asset retains full productive efficiency until the end of its service life and then drops to zero. Hyperbolic depreciation does not use retirements data and instead uses the hyperbolic profile to depreciate capital assets over time. • Geometric decay: Under this profile, for each period of time, the asset is assumed to lose a fixed percentage of the productivity of the previous period. The assets therefore experience substantial losses of efficiency early in its lifetime but retains a long tail of low levels of efficiency toward the end of its life (a convex profile). A mailing list of customers 46 Retirements are the original book cost of utility plant taken out of service and removed from plant-in-service, not the cash cost of removing it or the replacement cost of the new asset. FERC separately defines cost of removal as the cost of demolishing, dismantling, tearing down, or otherwise removing electric plant. 47 ECFR. PART 101—UNIFORM SYSTEM OF ACCOUNTS PRESCRIBED FOR PUBLIC UTILITIES AND LICENSEES SUBJECT TO THE PROVISIONS OF THE FEDERAL POWER ACT. 2026. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  5. Page 35 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 33 of 102 follows a geometric depreciation in productivity because each address has the same chance of becoming unusable in any given period. The list will depreciate in productivity as people change jobs, abandon accounts, or unsubscribe. Like hyperbolic depreciation, geometric depreciation does not use retirements data and instead retires capital using the geometric depreciation profile. Figure 11. Capital asset (with useful service life of 35 years) depreciation profiles 1 Physical depreciation profile 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 5 10 15 20 25 30 35 Useful asset life Hyperbolic Geometric One-Hoss Shay LEI ultimately determined OHS to be the most appropriate physical depreciation method for this industry study, based on two main factors. Firstly, the expected productivity profile of capital EDC assets matches OHS the closest out of the three, with full efficiency until the end of life. The OHS profile also allows us to consider retirements of capital reported by the utilities and therefore take into account explicitly when certain equipment is retired because it can no longer provide services. A hyperbolic decay profile may be considered a close second although it requires certain assumptions for which data is not readily available. 48 These assumptions are discussed in detail 47F 48 The hyperbolics sensitivity uses an estimated hyperbolic depreciation curve to depreciate assets over the course of the assumed economic life of electric distribution capital (35 years). However, we do not know how old the initial capital asset base is for each EDC. LEI assumes that the initial capital asset base is halfway through its useful life. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  6. Page 36 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 34 of 102 in Appendix C (Section 9.1). Therefore, LEI performed a sensitivity analysis using a hyperbolic decay profile, which is documented in Appendix C (see Section 9). A geometric decay profile is unrealistic for representing physical depreciation of capital used by EDCs. A geometric decay profile is less appropriate for modelling the physical depreciation of EDC capital because it assumes that an asset loses a constant proportion of its productive capacity in every period, including relatively large losses early in its service life. This does not align well with the observed performance of many long-lived distribution assets, such as poles, overhead conductors, underground cable, transformers, and related line equipment. In practice, these assets generally remain in place and continue to provide the service for which they were installed until they are replaced, retired, or failed. While maintenance needs and failure risk may increase with age, the asset’s productive capability typically does not decline smoothly at a constant geometric rate each year. For this reason, geometric depreciation can overstate the loss of service potential in the earlier years of an EDC asset’s life and understate the “in-service until replacement” nature of much distribution plant. 3.3.3 Service life of capital under the monetary approach A 35-year average service life (“ASL”) for electric distribution assets was estimated through an empirical asset turnover analysis drawing on FERC Form 1 data for a broad sample of U.S. electric utilities. The cumulative sum of annual distribution plant retirements across the sample from 1989 through 2024 totaled approximately $88.6 billion, a figure that closely approximates the gross book value of distribution plant in service recorded at the end of 1988, which stood at approximately $88.7 billion. The convergence of these two figures implies that the industry required roughly 36 years to retire an asset base equivalent to its starting value, yielding an empirical estimate of the average service life in that range. Rounding to the nearest standard interval, a 35-year ASL was determined to represent a reasonable and appropriate estimate for use in the TFP analysis. 3.3.4 Deriving the capital input quantity LEI obtained the quantity of capital stock using the perpetual inventory equation, which has been adopted in numerous TFP studies used in ratemaking globally. 49 To calculate the capital stock in the current year (Kt), the perpetual inventory equation takes the end of year capital stock (gross book value) from the previous year (Kt-1) and adds in the gross book value of new additions (I) and deducts the gross book value of retirements (R) in year t. The new additions and retirement data were collected from FERC Form 1. 50 However, because the equation is incorporating the monetary value of assets of different vintages (and therefore in nominal dollars from different 48F 49F 49 This approach has been used in TFP studies that were ultimately accepted in Alberta, Australia, the UK, Massachusetts, New Hampshire, and Ontario. 50 FERC Form 1. Line No. 16. Title of Schedule Electric Plant in Service. Reference Page No. 204. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  7. Page 37 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 35 of 102 years), the capital additions and retirements must be deflated. LEI used the BLS Producer Price Index for Construction Materials 51 to deflate the assets into real (1988) dollars; the trend in the BLS PPI since 1988 is shown in the figure below. 52 50F 51F Figure 12. Normalized BLS PPI trend 1988-2024 (1988=1) 3.50 BLS PPI (1988=1) 3.00 2.50 2.00 1.50 1.00 0.50 0.00 Normalized PPI for Construction Materials Source: Bureau of Labor Statistics. PPI Commodity data for Special indexes-Construction materials, not seasonally adjusted. 2026 Because new additions are added in nominal dollars at time t, annual capital additions values are divided by the BLS PPI index also at time t. However, under the OHS approach, retirements need to be re-based to reflect their full real monetary value when they occur at the end of their service 51 Bureau of Labor Statistics. PPI Commodity data for Special indexes-Construction materials, not seasonally adjusted. 2026. 52 LEI also evaluated the Handy-Whitman Index (“HWI”) of public utility construction costs as a potential capital price deflator. LEI ultimately selected the BLS Producer Price Index for two primary reasons. First, unlike the PPI, the HWI is proprietary, and its underlying methodology and data sources are not publicly disclosed, making it difficult to independently evaluate or replicate the resulting estimates. Second, sensitivity testing demonstrated that use of the HWI generated implausibly large real retirement values for certain utilities, resulting in negative estimates of real capital stock under the perpetual inventory method. These outcomes are not economically plausible and would have necessitated the exclusion of affected utilities from the sample. The issue became more pronounced under assumptions of longer asset service lives (i.e., 40, 45, and 50 years). London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  8. Page 38 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 36 of 102 life (i.e., t minus the average service life s). As noted above, LEI assumed an average service life of 35 years (therefore t is equal to 1989 for a retirement that is taking place in 2024). The equation for estimating the real capital quantity in any given year t under the perpetual inventory formula is shown below: 𝐾𝐾𝑡𝑡 = 𝐾𝐾𝑡𝑡−1 + 𝐼𝐼𝑡𝑡 𝑅𝑅𝑡𝑡 − 𝐵𝐵𝐵𝐵𝐵𝐵_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡 𝐵𝐵𝐵𝐵𝐵𝐵_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡−𝑠𝑠 The first year for which one estimates the capital input quantity is called the “Benchmark Year”. The best available information to construct a benchmark value is the gross book value of all capital assets and equipment, which is made up of assets of different vintages. The capital stock measure is sensitive to the age of the various capital components in the gross book value. To improve the precision of the capital stock estimates for the years in the TFP study, it is useful to select a benchmark year that is well before the beginning of the TFP study period (in the case of LEI’s TFP Study, the first year of the study period is 2005). The results of the perpetual inventory equation in terms of real capital quantity are shown below in Figure 13. Figure 13. Real capital quantity from 2005 to 2024 for the U.S. EDC industry, 1988 $000s 250,000,000 200,000,000 150,000,000 100,000,000 50,000,000 London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 - 2005 Real capital quantity (1988 $000s) 300,000,000
  9. Page 39 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 37 of 102 3.3.5 Capital input price The capital input price measures the trend in the implicit rental price corresponding to a unit of capital quantity. Unlike the OM&A input price index, the capital input price is not used to deflate the capital input quantity. Instead, the capital input price is used to weight the capital input quantity in the total input quantities over time (mechanically, this is achieved by multiplying the capital input quantity by the capital input price, which results in the total capital quantity that is then represented in the calculation of the composite input index and the resulting TFP index). 53 52F LEI used the implicit rental price formula developed in a seminal paper by Christensen and Jorgenson (1969) to estimate the capital input price, which has also been used in numerous TFP studies. 54 The price of capital under this approach is based on an equilibrium relationship between the price an investor is willing to pay for an asset and the after-tax expected value of services that the asset will provide over the asset’s lifetime. This relationship is called the implicit rental price formula and has the following mathematical representation: 53F −1 1 − 𝑢𝑢𝑢𝑢 1 + 𝑖𝑖 35 𝑃𝑃𝐾𝐾𝑡𝑡 = (𝑟𝑟 − 𝑖𝑖) 1 − 1 − 𝑢𝑢 1 + 𝑟𝑟 𝐵𝐵𝐵𝐵𝑆𝑆_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡−1 The variable u represents the corporate income tax rate, the variable z represents the present value of tax depreciation charges on one dollar of investment in distribution assets, the variable r represents the forward-looking cost of capital, and the variable i represents the forward-looking inflation rate. The service life (35 years) is also used in the implicit rental price formula. Corporate income tax rate (u): LEI used the applicable corporate tax rate in each state for u for the 2005-2024 period. A 35% federal tax rate from 2005 to 2017 and 21% from 2018 to 2024 were used for states with no state tax (e.g., Nevada, Ohio, Texas, Washington, and Wyoming). Present value of tax depreciation charges (z): This represents the present value of future depreciation on new investment. This component is used because depreciation for tax purposes typically takes place over a much shorter period than is allowed for ratemaking purposes. z is a function of the tax depreciation method used, the service life, and the weighted average cost of capital (“WACC”). LEI applied the sum of years’ digits method, and the resulting value for this study was 0.68. z is summarized as follows: 53 The exogenous approach to weighting the capital input quantity is sometimes referred to as the “direct” approach as the annual cost of using capital inputs can be measured directly by applying the sum of an estimated depreciation rate and a rate reflecting the opportunity cost of capital to the value of the assets. This is different from an endogenous approach, which assumes that the capital cost weighting is the residual of the utility's total revenue minus OM&A. 54 Originally derived from L.R. Christensen and D.W. Jorgenson. The Measurement of Real Capital Input, 1929 – 1967. Review of Income and Wealth, Series 15, No. 4, (December 1969). Pages 293-320. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  10. Page 40 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 38 of 102 𝑇𝑇+1 2 (1 + 𝑅𝑅) 1 𝑧𝑧 = 1 − 1 − 𝑅𝑅𝑅𝑅 𝑅𝑅(𝑇𝑇 + 1) (1 + 𝑅𝑅) Forward-looking cost of capital (WACC) and inflation rate (r): A common method is to assume that investor’s forward-looking real rate of return (cost of capital less the inflation rate) is constant through time. This method produces a relatively stable input price series (in contrast to using just the current year WACC and inflation rates). The resulting average WACC 55 of 6.05% and expected long-term inflation rate 56 of 1.53% (over the study timeframe, 2005-2024) was then used in the implicit rental price formula for all U.S. EDCs. 54F 55F 3.4 Selecting an output metric In U.S. EDC TFP studies, output is often measured using customer counts and/or kWh sales/deliveries. Customers proxy the scale of distribution service because utilities must connect and maintain service to customers regardless of usage, while sales capture the volume of electricity delivered. Studies often test both because sales can be affected by efficiency and DERs, while customer counts may not capture usage intensity. Customer data are based on EIA 861, 57 while sales data are compiled at the operating subsidiary level from FERC Form 1. 58 56F 57F LEI used the number of customers served by the distribution network(s) as the output measure. A key advantage of using this dataset is that it is a numerical data point which is both available and consistently measured across EDCs. Electricity sales, which LEI also considered as an output, are affected by weather patterns, which can vary considerably across geographies and years and therefore could cause some distortion to the resulting TFP trends. Figure 14 below presents trends in the number of customers and electricity sales, as well as their corresponding growth rates in Figure 15. This distinction shows that customer counts increased steadily over the study period, 55 In calculating the WACC, the average cost of debt is based on the average Moody’s seasoned AAA bond yield, published by the Federal Reserve Bank of St. Louis (Source: Federal Reserve Bank of St. Louis. Moody’s Seasoned Aaa Corporate Bond Yield. 2026.) The cost of equity is based on the average approved return on equity (“ROE”) of U.S. electric utilities in the sample over time (Source: S&P Global. Regulatory Research (RRA), ROE rate case history dataset, 1977–2024, downloaded from S&P Capital IQ Pro. 2026.). The debt/equity ratio was assumed to be 50%, based on an average of reported debt/equity ratios for U.S. electricity utilities. (Source: S&P Global. Regulatory Research (RRA), ROE rate case history dataset, 1977–2024, downloaded from S&P Capital IQ Pro. 2026.). 56 The long-term expected inflation rate is calculated using the Fisher Ideal equation based on rates of the 10-Year U.S. Treasury bonds (Source: U.S. Department of the Treasury. Daily Treasury Rates. 2026.) and the 10-Year U.S. Treasury Inflation-Protected Securities (“TIPS”) (Source: Board of Governors of the Federal Reserve System. Selected Interest Rates (Daily) - H.15. 2026.) from 2005-2024. 57 EIA. Annual Electric Power Industry Report. Form EIA-861, detailed data files. Released October 7, 2025. 58 FERC Form 1. Line No. 44. Title of Schedule Sales of Electricity by Rate Schedules. Reference Page No. 304. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com