  1. Page 38 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 36 of 102 life (i.e., t minus the average service life s). As noted above, LEI assumed an average service life of 35 years (therefore t is equal to 1989 for a retirement that is taking place in 2024). The equation for estimating the real capital quantity in any given year t under the perpetual inventory formula is shown below: 𝐾𝐾𝑡𝑡 = 𝐾𝐾𝑡𝑡−1 + 𝐼𝐼𝑡𝑡 𝑅𝑅𝑡𝑡 − 𝐵𝐵𝐵𝐵𝐵𝐵_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡 𝐵𝐵𝐵𝐵𝐵𝐵_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡−𝑠𝑠 The first year for which one estimates the capital input quantity is called the “Benchmark Year”. The best available information to construct a benchmark value is the gross book value of all capital assets and equipment, which is made up of assets of different vintages. The capital stock measure is sensitive to the age of the various capital components in the gross book value. To improve the precision of the capital stock estimates for the years in the TFP study, it is useful to select a benchmark year that is well before the beginning of the TFP study period (in the case of LEI’s TFP Study, the first year of the study period is 2005). The results of the perpetual inventory equation in terms of real capital quantity are shown below in Figure 13. Figure 13. Real capital quantity from 2005 to 2024 for the U.S. EDC industry, 1988 $000s 250,000,000 200,000,000 150,000,000 100,000,000 50,000,000 London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 - 2005 Real capital quantity (1988 $000s) 300,000,000
  2. Page 39 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 37 of 102 3.3.5 Capital input price The capital input price measures the trend in the implicit rental price corresponding to a unit of capital quantity. Unlike the OM&A input price index, the capital input price is not used to deflate the capital input quantity. Instead, the capital input price is used to weight the capital input quantity in the total input quantities over time (mechanically, this is achieved by multiplying the capital input quantity by the capital input price, which results in the total capital quantity that is then represented in the calculation of the composite input index and the resulting TFP index). 53 52F LEI used the implicit rental price formula developed in a seminal paper by Christensen and Jorgenson (1969) to estimate the capital input price, which has also been used in numerous TFP studies. 54 The price of capital under this approach is based on an equilibrium relationship between the price an investor is willing to pay for an asset and the after-tax expected value of services that the asset will provide over the asset’s lifetime. This relationship is called the implicit rental price formula and has the following mathematical representation: 53F −1 1 − 𝑢𝑢𝑢𝑢 1 + 𝑖𝑖 35 𝑃𝑃𝐾𝐾𝑡𝑡 = (𝑟𝑟 − 𝑖𝑖) 1 − 1 − 𝑢𝑢 1 + 𝑟𝑟 𝐵𝐵𝐵𝐵𝑆𝑆_𝑃𝑃𝑃𝑃𝑃𝑃𝑡𝑡−1 The variable u represents the corporate income tax rate, the variable z represents the present value of tax depreciation charges on one dollar of investment in distribution assets, the variable r represents the forward-looking cost of capital, and the variable i represents the forward-looking inflation rate. The service life (35 years) is also used in the implicit rental price formula. Corporate income tax rate (u): LEI used the applicable corporate tax rate in each state for u for the 2005-2024 period. A 35% federal tax rate from 2005 to 2017 and 21% from 2018 to 2024 were used for states with no state tax (e.g., Nevada, Ohio, Texas, Washington, and Wyoming). Present value of tax depreciation charges (z): This represents the present value of future depreciation on new investment. This component is used because depreciation for tax purposes typically takes place over a much shorter period than is allowed for ratemaking purposes. z is a function of the tax depreciation method used, the service life, and the weighted average cost of capital (“WACC”). LEI applied the sum of years’ digits method, and the resulting value for this study was 0.68. z is summarized as follows: 53 The exogenous approach to weighting the capital input quantity is sometimes referred to as the “direct” approach as the annual cost of using capital inputs can be measured directly by applying the sum of an estimated depreciation rate and a rate reflecting the opportunity cost of capital to the value of the assets. This is different from an endogenous approach, which assumes that the capital cost weighting is the residual of the utility's total revenue minus OM&A. 54 Originally derived from L.R. Christensen and D.W. Jorgenson. The Measurement of Real Capital Input, 1929 – 1967. Review of Income and Wealth, Series 15, No. 4, (December 1969). Pages 293-320. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  3. Page 40 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 38 of 102 𝑇𝑇+1 2 (1 + 𝑅𝑅) 1 𝑧𝑧 = 1 − 1 − 𝑅𝑅𝑅𝑅 𝑅𝑅(𝑇𝑇 + 1) (1 + 𝑅𝑅) Forward-looking cost of capital (WACC) and inflation rate (r): A common method is to assume that investor’s forward-looking real rate of return (cost of capital less the inflation rate) is constant through time. This method produces a relatively stable input price series (in contrast to using just the current year WACC and inflation rates). The resulting average WACC 55 of 6.05% and expected long-term inflation rate 56 of 1.53% (over the study timeframe, 2005-2024) was then used in the implicit rental price formula for all U.S. EDCs. 54F 55F 3.4 Selecting an output metric In U.S. EDC TFP studies, output is often measured using customer counts and/or kWh sales/deliveries. Customers proxy the scale of distribution service because utilities must connect and maintain service to customers regardless of usage, while sales capture the volume of electricity delivered. Studies often test both because sales can be affected by efficiency and DERs, while customer counts may not capture usage intensity. Customer data are based on EIA 861, 57 while sales data are compiled at the operating subsidiary level from FERC Form 1. 58 56F 57F LEI used the number of customers served by the distribution network(s) as the output measure. A key advantage of using this dataset is that it is a numerical data point which is both available and consistently measured across EDCs. Electricity sales, which LEI also considered as an output, are affected by weather patterns, which can vary considerably across geographies and years and therefore could cause some distortion to the resulting TFP trends. Figure 14 below presents trends in the number of customers and electricity sales, as well as their corresponding growth rates in Figure 15. This distinction shows that customer counts increased steadily over the study period, 55 In calculating the WACC, the average cost of debt is based on the average Moody’s seasoned AAA bond yield, published by the Federal Reserve Bank of St. Louis (Source: Federal Reserve Bank of St. Louis. Moody’s Seasoned Aaa Corporate Bond Yield. 2026.) The cost of equity is based on the average approved return on equity (“ROE”) of U.S. electric utilities in the sample over time (Source: S&P Global. Regulatory Research (RRA), ROE rate case history dataset, 1977–2024, downloaded from S&P Capital IQ Pro. 2026.). The debt/equity ratio was assumed to be 50%, based on an average of reported debt/equity ratios for U.S. electricity utilities. (Source: S&P Global. Regulatory Research (RRA), ROE rate case history dataset, 1977–2024, downloaded from S&P Capital IQ Pro. 2026.). 56 The long-term expected inflation rate is calculated using the Fisher Ideal equation based on rates of the 10-Year U.S. Treasury bonds (Source: U.S. Department of the Treasury. Daily Treasury Rates. 2026.) and the 10-Year U.S. Treasury Inflation-Protected Securities (“TIPS”) (Source: Board of Governors of the Federal Reserve System. Selected Interest Rates (Daily) - H.15. 2026.) from 2005-2024. 57 EIA. Annual Electric Power Industry Report. Form EIA-861, detailed data files. Released October 7, 2025. 58 FERC Form 1. Line No. 44. Title of Schedule Sales of Electricity by Rate Schedules. Reference Page No. 304. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  4. Page 41 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 39 of 102 while electricity sales were materially more volatile year-to-year, with periods of sharp decline and recovery. Additionally, utilities build systems to serve customers and not necessarily the specific amount of electricity consumed per customer as that is likely to change with time. Notably, the use of total customers served has become a common practice among TFP studies for the EDC industry. 59 Regardless, LEI perform sensitivity analysis using sales (see Appendix B in Section 8). 58F Figure 14. Total number of customers served vs. electricity sales (reflecting all 88 EDCs studied) 105,000,000 2,250,000,000 2,200,000,000 100,000,000 2,100,000,000 90,000,000 Sales (MWh) Customers 2,150,000,000 95,000,000 2,050,000,000 85,000,000 2,000,000,000 Customers 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 1,950,000,000 2005 80,000,000 Sales Source: EIA 861 and FERC Form 1. Line No. 44. Title of Schedule Sales of Electricity by Rate Schedules. Reference Page No. 304. 59 Customers are commonly used as the output variable in TFP studies. For example, National Grid (MA Electric Co.) (Docket No. 23-150), Public Service Company of New Hampshire (d/b/a Eversource Energy) (Docket No. DE 24-070), FortisBC Energy Inc. and Fortis BC Inc., together Fortis BC (Order Number G-69-25), and NSTAR Electric and Western MA Electric Co. (Docket No. DPU 22-22). London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  5. Page 42 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 40 of 102 Figure 15. Total number of customers served vs. electricity sales growth rates (reflecting all 88 EDCs studied) 5% 4% 3% Growth rate 2% 1% 0% -1% -2% -3% -4% Customers growth 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 -5% Sales growth Source: EIA 861 and FERC Form 1. Line No. 44. Title of Schedule Sales of Electricity by Rate Schedules. Reference Page No. 304. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  6. Page 43 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 41 of 102 4 Industry TFP and PFP results The TFP results indicate that productivity declined over the study period (2005-2024). While the number of customers increased gradually, total inputs (capital and OM&A) rose much more rapidly, particularly after the mid-2010s and again around 2020. This suggests that the sector required increasingly more resources to serve each customer over time. As a result, the chained Fisher TFP index fell from 1.00 in 2005 to 0.77 by 2024 (see grey line in Figure 16), indicating a deterioration in measured productivity by -1.40% annually between 2005 and 2024 (the tabular results are presented in Figure 22). In a PBR context, this pattern suggests limited or negative historical productivity growth, which would place downward pressure on the productivity factor used in the rate-setting formula. 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 Total inputs (Capital and OM&A) 4.1 Total output (customers) 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 0.00 2005 Chained Fisher Ideal index (2005=1) Figure 16. Chained Fisher Ideal indices for industry TFP, inputs, and output TFP Industry input index The chained Fisher Ideal index for capital inputs over the 2005 to 2024 period increased steadily, rising from 1.00 in 2005 to 1.92 by 2024 (see Figure 17). This indicates that the quantity of capital inputs used by the sector nearly doubled over the period. Growth was relatively gradual in the London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  7. Page 44 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 42 of 102 early years, but accelerated in later years, with a more pronounced increase through the late 2010s and early 2020s. Capital inputs grew at an average annual rate of 3.44% over the full period (see Figure 22). This suggests that capital investment was a major driver of overall input growth. 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 0.00 2005 Chained Fisher Ideal index (2005=1) Figure 17. Chained Fisher Ideal index for industry capital Capital The chained Fisher Ideal index for OM&A inputs increased from 1.00 in 2005 to 1.16 by 2024, indicating more modest growth relative to capital inputs (see Figure 18). OM&A inputs rose during the early part of the period, reaching roughly 1.11 by 2011, then falling until 2020. The series shows some volatility around 2020, followed by a modest increase and then slight decline toward the end of the period. OM&A inputs have grown at an average annual rate of 0.79% over the full period (see Figure 22). Overall, OM&A input growth was positive but materially slower than capital input growth. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  8. Page 45 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 43 of 102 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 0.00 2005 Chained Fisher Ideal index (2005=1) Figure 18. Chained Fisher Ideal index for industry OM&A OM&A The chained Fisher Ideal index for total inputs, where total inputs equal the composite of capital inputs and OM&A inputs, increased from 1.00 in 2005 to around 1.51 by 2024 (see Figure 19). To develop the total composite input index, LEI used the capital-to-OM&A split between the implicit capital price in 1988 dollars and the implicit OM&A price in 1988 dollars as the relative input price weights. 60 This reflects sustained growth in the overall quantity of inputs used by the sector, with the increase driven primarily by the strong growth in capital inputs, partially offset by the more moderate growth in OM&A inputs. The total input index shows a steady upward trend throughout most of the period, with a noticeable increase around 2020 and continued growth thereafter. Total inputs have grown at an average annual rate of 2.18% over the full period (see Figure 22). This composite trend suggests that the sector became increasingly input-intensive over time, particularly due to rising capital inputs. 59F 60 The average capital-to-OM&A split between implicit capital price in 1988 dollars and the implicit OM&A price in 1988 dollars between 2005-2024 is 46%/54%. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  9. Page 46 of 104Match

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 44 of 102 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 0.00 2005 Chained Fisher Ideal index (2005=1) Figure 19. Chained Fisher Ideal index for total industry inputs (capital and OM&A) Total inputs (Capital and OM&A) 4.2 Industry output index The chained Fisher Ideal index for total output, measured using the number of customers, increased from 1.00 in 2005 to approximately 1.16 by 2024 (see Figure 20), indicating that the customer base grew by roughly 16% over the study period. Growth was relatively steady but modest through the mid-2010s, followed by a somewhat stronger increase beginning around 2018 and continuing through 2020. Total output has grown at an average annual rate of 0.78% over the full period (as summarized in Figure 22). Compared with the total input index, which reflects the composite of capital and OM&A inputs, output growth was considerably slower, contributing to the observed decline in measured TFP over the period. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
  10. Page 47 of 104

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-2 November 18, 2026 Page 45 of 102 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 2024 2023 2022 2021 2020 2019 2018 2017 2016 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 0.00 2005 Chained Fisher Ideal index (2005=1) Figure 20. Chained Fisher Ideal index for total industry output (customers) Total output (customers) 4.3 Detailed results for industry TFP and PFP growth 4.3.1 Industry total factor productivity The chained Fisher Ideal index for TFP over the 2005 to 2024 period is calculated as the ratio of the total output index to the total input index, where output is measured using customers and inputs reflect the composite of capital and OM&A inputs. The TFP index declined from 1.00 in 2005 to 0.77 by 2024, indicating a material deterioration in measured productivity over the study period (see Figure 21). London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
2 pages match

As listed on the current system

Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: Julia Frayer [26-05-10]