Prefiled testimony
Witness: Julia Frayer
Files4
Docket No. 26-05-10 CLP Rebuttals Filing Letter (11.18.26).pdf
PDF · 152 KB · 3 pagesText searchable
Download Docket No. 26-05-10 CLP Rebuttals Filing Letter (11.18.26).pdfRead the text of Docket No. 26-05-10 CLP Rebuttals Filing Letter (11.18.26).pdf
Exhibit CLP-PBR-REBUTTAL-1.pdf
PDF · 565 KB · 70 pagesText searchable
Download Exhibit CLP-PBR-REBUTTAL-1.pdfRead the text of Exhibit CLP-PBR-REBUTTAL-1.pdf
Exhibit CLP-PBR-Rebuttal-2 TFP Report.pdf
PDF · 1.3 MB · 104 pagesText searchable
Download Exhibit CLP-PBR-Rebuttal-2 TFP Report.pdfRead the text of Exhibit CLP-PBR-Rebuttal-2 TFP Report.pdf
Exhibit CLP-PBR-Rebuttal-3 LEI Benchmarking Report.pdf
PDF · 594 KB · 45 pagesText searchable
Download Exhibit CLP-PBR-Rebuttal-3 LEI Benchmarking Report.pdfRead the text of Exhibit CLP-PBR-Rebuttal-3 LEI Benchmarking Report.pdf
Page 21 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 21 of 45 These business drivers of cost are further explored through econometric benchmarking in Section 4.4. Figure 8. Total costs per customer vs. distribution business share of utility, 2024 2024 Total Cost (Real $)/Customer 700 600 CL&P 500 400 300 200 100 0 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Distribution business share (distribution plant as a % of total plant) Midwest Linear (Midwest) 3.5 Northeast Linear (Northeast) South Linear (South) West Linear (West) CL&P cost performance in comparison to industry average LEI also examined the unit costs of CL&P relative to the industry. Over the 10-year period, CL&P’s OM&A costs, capital costs, and total costs per customer averaged $206, $163, and $369, respectively. The U.S. industry average for this same period was $169, $187, and $356, respectively for real OM&A, capital, and total costs per customer. CL&P’s OM&A costs generally exceeded the industry average, while its capital costs have consistently remained below the industry average as presented in Figure 9. Notably, CL&P’s capital cost performance relative to the industry average has become more favorable in recent years, with capital costs averaging 16.5% below the industry average over the most recent four years, compared with 12.6% below over the ten-year period. This relatively strong capital cost performance has helped offset CL&P’s above-average OM&A costs, keeping its overall total costs per customer relatively close to the industry average. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 22 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 22 of 45 Figure 9. CL&P’s actual unit costs relative to industry average by cost component, 2015–2024, % (graph) % difference from the industry average 50.0% 40.0% 30.0% 20.0% 10.0% 0.0% 2015 2016 2017 2018 2019 2020 2022 2021 2023 2024 -10.0% -20.0% -30.0% Total Costs Capital Costs OM&A Costs Figure 10. CL&P’s actual unit costs relative to industry average by cost component, 2015–2024, % (table) Year Total Cost Capital Cost OM&A Cost 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 10-year average 4-year average 5.3% 5.0% 5.5% 0.0% 4.1% -1.1% 5.0% -2.1% 7.4% 7.5% 3.7% 4.4% -9.8% -10.8% -8.2% -9.3% -9.9% -11.6% -12.8% -17.3% -19.5% -16.5% -12.6% -16.5% 19.6% 20.4% 19.4% 9.8% 19.6% 10.6% 26.5% 15.9% 40.3% 37.8% 22.0% 30.1% Note: A positive value indicates that CL&P's costs are above the benchmark, while a negative value indicates that CL&P's costs are below the benchmark. Accordingly, negative values indicate relatively more favorable cost performance, as they reflect lower costs than the benchmark. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 23 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 23 of 45 4 Econometric cost benchmarking 4.1 Overview of econometric techniques Cost benchmarking analysis can also be conducted using econometric methods. In LEI’s professional judgement, if the data allows, an econometric benchmarking analysis is preferable to the unit cost benchmarking approach. This is because unit cost benchmarking, as detailed in Section 3, typically compares utility costs by dividing expenditures such as OM&A, capital, or total costs by a single output measure such as the number of customers served (or the volume of electricity sales). While useful as a high-level indicator, this approach can be overly simplistic as it does not account for the numerous other factors that may influence an EDC’s costs. These factors may include among others, input prices such as the cost of labor and capital, the customer density of the EDC’s service territory, the composition of its customer base (proportion of residential versus commercial and industrial customers), and various other operating/business conditions which may differ across EDCs, but are not necessarily under the EDC management’s control. Furthermore, the unit cost benchmarking does not explain why an EDC may exhibit higher or lower unit costs. For example, differences in unit costs may reflect economies of scale or scope, or variations in business drivers that materially influence costs, such as input prices, network configuration, and customer mix. Econometric benchmarking provides a more comprehensive approach by estimating the statistical relationship between a dependent variable, such as total cost, capital cost or OM&A cost, and one or more independent, or explanatory variables that are expected to influence those costs. These explanatory variables may also be referred to as business drivers. By controlling for these types of business drivers, econometric analysis can help isolate the relationship between utility costs and factors that influence costs and may be outside, or only partially within, management’s control. This allows for a more meaningful assessment of relative cost performance than a unit cost comparison alone. In particular, econometric cost benchmarking analysis can provide an estimate of relative efficiency after accounting for differences in operating conditions and important business factors across U.S. EDCs, thus ensuring a more accurate and informed benchmarking analysis. The econometric approach to cost benchmarking relies on calculating the average (or “mean”) value for a feature such as number of customers and comparing how an individual observation in the data (for example, a particular EDC in a single year) compares to the average size of all the EDCs across all the years in the data. Econometric analysis then tests for correlations across such differences in means. For example, it tests whether the difference from the mean number of customers is correlated with the difference from the mean total cost expenditures for an EDC. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 24 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 24 of 45 Econometrics-based benchmarking is a well-established approach for comparing utilities based on their expenditures, outputs, and operating conditions. It has been used or relied upon in regulatory proceedings and benchmarking frameworks in several jurisdictions, including the United States, Canada, Australia, New Zealand, and the United Kingdom. 11 10F10F 4.2 LEI’s econometrics benchmarking approach As with the unit cost benchmarking, LEI developed three econometric cost benchmarking models: an OM&A cost model, a Capital cost model, and a Total Cost model, using most of the data from the LEI Industry TFP Study. LEI performed the econometric benchmarking analysis using actual (historical) data from a sample of 88 EDCs, including CL&P, to estimate the average relationship between costs and factors that impact or otherwise contribute to those costs. Such a relationship is also known as a cost function. LEI used 10 years of data (2015-2024), resulting in a balanced panel dataset with 880 total observations. A panel dataset means that a sample group of EDCs is observed across multiple years. This structure enables examination of differences in costs across EDCs, while also capturing how costs and cost drivers change over time. A balanced panel means that each EDC in the sample is observed in each year of the study period. In other words, there are no missing utility-year observations in the final dataset, allowing for a consistent comparison of cost performance across utilities and over time. LEI’s choice of 10 years of data strikes an appropriate balance between two competing objectives: 10 years provides enough data points to support a statistically robust analysis given the need to test various business drivers (econometric models benefit from having a sufficiently large number of observations, as this improves the precision and reliability of the statistical estimates), while 11 See Ontario Energy Board. Performance Assessment. accessed July 6, 2026 https://www.oeb.ca/ontarios-energy- sector/performance-assessment; Ontario Energy Board, PEG Benchmarking Report 2024 (Toronto: Ontario Energy Board, 2024) <https://www.oeb.ca/sites/default/files/PEG%20Report%20to%20the%20Ontario%20 Energy%20Board%202024.pdf> ; Australian Energy Regulator. Annual Benchmarking Report—Distribution and Transmission 2025. (Melbourne: Australian Energy Regulator, 2025), https://www.aer.gov.au/publications/reports/performance/annual-benchmarking-report-distributionand-transmission-2025; Office of Gas and Electricity Markets (Ofgem). RIIO-ED2 Final Determinations: Core Methodology. (London: Ofgem, November 2022) https://www.ofgem.gov.uk/sites/default/files/202211/RIIO-ED2%20Final%20Determinations%20Core%20Methodology.pdf; Michael G. Pollitt. Benchmarking and Optimal Scale for Electricity Distribution Boards in New Zealand: A Study for the Commerce Commission. (Wellington: New Zealand Commerce Commission, 2025), https://comcom.govt.nz/assets/Documents/productivity-and-efficiency-study-of-electricitydistributors/Michael-Pollitt-Benchmarking-and-Optimal-Scale-for-Electricity-Distribution-Boards-in-NewZealand-A-study-for-the-Commerce-Commission-20-November-2025.pdf London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 25 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 25 of 45 also capturing a range of historical operating conditions to ensure continued relevance to inform future rate setting in a PBR context. In addition to estimating how each business driver affects annual costs (expenditures) by EDCs in the U.S. on average, including both the magnitude and direction of that relationship, LEI’s econometric approach also allows for a comparison of an EDC’s actual cost performance against its model-predicted cost performance in each year of the analysis. As detailed in Sections 4.4 and 4.5, the annual model-predicted costs reflect the level of annual costs that would be expected for an EDC given its specific operating characteristics and business drivers. Comparing actual costs to model-predicted costs therefore provides an indication of relative cost performance after controlling for differences in business conditions, developed on the basis of cross-sectional data representing the U.S. EDC sector. 4.3 Data sources used LEI developed the econometric benchmarking dataset using cost data from LEI’s Industry TFP study and explanatory variables that control for key cost drivers for EDCs. Section 4.4 discusses the variables used in the econometric benchmarking and their respective results in the preferred specifications. The econometric models use utility-year observations and are designed to explain differences in OM&A cost, capital cost, and total cost across utilities and over time. The cost variables are constructed on a nominal basis using FERC Form 1 data. Nominal total cost is calculated as the sum of nominal OM&A cost and nominal capital cost. 12 Each cost variable is transformed into natural logarithmic form so that the model can compare proportional differences in costs across utilities of different sizes. 11F11F The explanatory variables were selected to control for the price of key inputs (such as marketprevailing wages and capital price index (to reflect generic inflationary pressures on capital)), differences in scale (using customers as proxy), network density (in terms of customers served per circuit), economies of scope (related to size of distribution business to total utility business), and time. These factors are expected to affect cost levels and therefore need to be controlled for before comparing CL&P’s actual costs to model-predicted costs. 12 LEI uses nominal cost measures because the econometric models include input price variables to control for differences in cost conditions across utilities and over time. Labor price is controlled for using state-level average annual pay, while capital price is controlled for using a capital price index based on the Bureau of Labor Statistics PPI in the capital and total cost models. Therefore, the dependent variables are kept in nominal terms so that the model benchmarks actual reported costs, while the explanatory variables separately account for input price differences. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 26 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 26 of 45 The variables used in the econometric models are summarized in Figure 11 and described in further detail below. Figure 11. Overview of the variables used in LEI’s models Dependent variable OM&A cost Dependent variable Total Cost Dependent variable Capital Cost Independent variable Labor price Customers Distribution business share Time trend Independent variable Type of variable or transformation natural log natural log natural log - Labor price Capital price index Customers Type of variable or transformation natural log natural log natural log (Customers)2 Network density Distribution business share Time trend squared natural log - Independent variable Type of variable or transformation natural log natural log Customers 2 (Customers) Network density Labor price Capital price index Distribution business share Time trend squared natural log natural log - The three dependent variables included in LEI’s models were OM&A cost, capital cost, and total cost as described below: • OM&A cost: OM&A cost is one of the dependent variables in the benchmarking analysis. It reflects annual operations, maintenance, and administrative costs associated with electric distribution utility operations. OM&A cost is sourced from FERC Form 1 13 and constructed consistently with LEI’s TFP cost methodology. It is transformed into natural 12F12F 13 Federal Energy Regulatory Commission. FERC Form No. 1: Annual Report of Major Electric Utilities, Licensees and Others. Federal Energy Regulatory Commission, <www.ferc.gov/general-information-0/electric-industryforms> London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 27 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 27 of 45 logarithmic form (similar to all the other variables) which allows the model to compare proportional cost differences across utilities and years. • Capital cost: Capital cost is another dependent variable in the benchmarking analysis. It reflects the annual capital cost measure developed in LEI’s TFP cost model. Capital cost captures the cost associated with the use of capital assets in providing electric distribution service. This variable is sourced from FERC Form 1 and constructed consistently with LEI’s TFP cost methodology. • Total cost: Total cost is the third dependent variable in the benchmarking analysis. It is calculated as the sum of nominal OM&A cost and nominal capital cost. This variable captures the combined cost of operating, maintaining, and investing in the distribution system. LEI tested several independent variables in our models. These include labor price, capital price, customer scale, network density, share of distribution assets to total assets, and time trends: Input prices: • Labor price: Labor price is measured using state-level utility industry average annual pay. LEI relied on the BLS Quarterly Census of Employment and Wages (“QCEW”) 14 as the source for state-level wage data. This variable is used as a proxy for labor input prices and controls for differences in labor costs across states and years. Because labor costs vary across states and regions, utilities operating in higher-wage labor markets are generally expected to incur higher OM&A and total costs than otherwise comparable utilities operating in lower-wage labor markets, all else equal. 13F13F • Capital price index: Capital price is measured using a capital price index based on the BLS Producer Price Index (“PPI”). 15 This variable is used as a proxy for capital input prices. It controls for changes in the cost of capital-related inputs over time. The capital price index is included in the capital cost and total cost models because these models include capital-related costs as part of the dependent variable. 14F14F Other input variables: 14 U.S. Bureau of Labor Statistics. Quarterly Census of Employment and Wages. U.S. BLS, <www.bls.gov/cew/> 15 U.S. Bureau of Labor Statistics. Producer Price Indexes. <www.bls.gov/ppi/> London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 28 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 28 of 45 • Customer scale: Customer counts are used as the primary scale variable. LEI relied on customer count data from EIA Form 861. 16 The number of customers served provides a measure of the scale of each EDC’s distribution operations. All else equal, utilities serving more customers would be expected to incur higher total costs because they must construct, operate, and maintain larger distribution systems and provide service to a greater number of customer connections. In the capital cost and total cost models, LEI also included the square of logged customers to allow for potential non-linear scale effects. This allows the relationship between scale and cost to differ between smaller and larger utilities, rather than imposing a strictly linear relationship. 15F15F • Network density: Network density is measured using customers per circuit and is an important determinant of distribution costs. Distribution circuit information is sourced from EIA Form 861 and used to calculate the number of customers served per circuit. It controls for differences in the density of the distribution network. Network density also serves as an indicator of whether a utility primarily serves an urban or a rural service territory. All else equal, a utility serving more customers per circuit can spread fixed costs over a larger customer base. Conversely, a utility serving fewer customers per circuit typically requires more infrastructure relative to the number of customers served. As a result, utilities operating less densely populated distribution systems may face higher costs of providing distribution service. Because utilities generally have limited control over the geographic characteristics of their service territories, customer density, and customer mix, controlling for these business characteristics helps ensure that benchmarking comparisons reflect differences in cost performance rather than differences in operating environment. • Share of distribution business: Distribution plant share is measured as distribution plant as a share of total plant. This variable is calculated using FERC Form 1 plant data. It is used as a proxy for the extent to which a utility’s overall business is focused on distribution activities. Many, but not all, electric distribution utilities also own transmission assets and therefore operate a transmission business. Some utilities in the national sample also own regulated generation assets. Utilities with a broader mix of regulated business activities may benefit from economies of scope by spreading certain fixed costs—such as administrative and corporate support costs—across multiple business functions. Consequently, a utility with a lower distribution plant share (i.e., a greater proportion of non-distribution activities) would generally be expected to have lower distribution costs per customer, all else equal. Including this variable helps control 16 U.S. Energy Information Administration. Annual Electric Power Industry Report, Form EIA-861 Detailed Data Files. Electricity Data. <www.eia.gov/electricity/data/eia861/> London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 29 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 29 of 45 for differences in business scope and better isolate differences in distribution-related cost performance. • Time trend: LEI included an annual time trend covering 2015–2024. This variable is included as trend. The time trend captures residual cost changes over time that are not otherwise explained by scale, network density, input prices, customer mix, or distribution business share. Such changes may reflect common industry-wide trends, technology changes, changes in reporting, or other time-related effects. LEI tested several other independent variables, but they were ultimately excluded as they were found not to be statistically significant for the study timeframe and group of utilities. 17 16F16F 4.4 Overview of econometric models LEI’s econometric results show that the preferred cost models provide strong explanatory power and that the estimated coefficients are generally consistent with economic intuition. The OM&A, capital, and total cost models each have independent variables (representing business drivers) that explain a substantial share of the variation in utility costs across the 88 EDCs in the sample over the 2015–2024 period. The following findings summarize the main results from the preferred specifications and Appendix C show the total cost, capital, and OM&A cost economic results in table format. 18 17F17F • Labor prices are a major factor impacting costs, and in elasticity (percentage) terms, the largest marginal driver for OM&A. The coefficient is positive and statistically significant in all three models. In the OM&A model, the coefficient is 0.977 with a p-value of 0.000. The coefficient value reflects the marginal impact of market prevailing wages on OM&A costs – for every 10% change in wages, OM&A costs go up 9.73%. The p-value of 0.000 signifies that this finding is statistically significant with a 99.9% confidence level. In the total cost model, the coefficient is 0.627 with a p-value of 0.000. The lower coefficient in the total cost model relative to the OM&A model is not surprising given that other inputs, whose prices may not be correlated with labor prices, are part of total cost. In the capital cost model, the coefficient 17 LEI tested additional explanatory variables before selecting the preferred specifications. The share of non-residential customers was calculated as commercial and industrial customers divided by total customers, and was tested as a customer-mix variable but not retained because it was not statistically significant. Customer density was calculated as total customers divided by distribution circuits. Non-linear customer scale was constructed as the square of the natural logarithm of total customers. This non-linear customer scale term was retained in the total cost and capital cost models, but not in the OM&A model. Capital price variables were included in the total cost and capital cost models and were also tested in the OM&A model, but were not retained in the OM&A specification because they did not materially improve model fit. 18 See Section 7. London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.comPage 30 of 45
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-PBR-Rebuttal-3 November 18, 2026 Page 30 of 45 is 0.409 with a p-value of 0.000. The result is consistent with the more limited impact of labor on capital costs. Overall, these results indicate that utilities operating in higher-wage states tend to have higher expected costs, all else equal. • Capital price index has a statistically significant impact on the capital and total costs. In the total cost model, the coefficient is 0.252 with a p-value of 0.000. In the capital cost model, the coefficient is 0.427 with a p-value of 0.000. These results indicate that higher capital input prices are associated with higher expected capital-related costs, consistent with economic intuition. • Operating scale as measured by number of customers has an impact on OM&A cost. In the OM&A model, the coefficient for the natural log of the number of customers is 0.871 and is statistically significant, which means that with every 10% increase in customers, OM&A costs increase by 8.7%. The p-value indicates that we are 99.9% confident in these findings. This result is consistent with economic intuition: utilities serving more customers generally require more operating, maintenance, and administrative resources. • The total cost and capital cost models allow for non-linear operating scale effects, which may capture more nuanced impacts of operating scale across utilities of different sizes. LEI’s total cost and capital cost models include two variables for scale: natural log of Customers and the square of the natural log of Customers, which allows the relationship between customer scale and cost to be non-linear. This specification does not assume that the cost impact of customer scale is the same for all utilities. Instead, it allows the relationship between scale and cost to change as utilities become larger. A positive coefficient on the squared term indicates that cost elasticity increases with utility size. In the total cost model, the coefficient on Customers is -0.171 with a p-value of 0.457 (which means that this linear scale variable is not statistically significant at a conventional 95% confidence level), while the coefficient on Customers squared is 0.041 with a p-value of 0.000. In the capital cost model, the coefficient on Customers is -0.037 with a p-value of 0.884 (again, this means that this linear scale variable is not statistically significant at a conventional 95% confidence level), while the coefficient on Customers squared is 0.039 with a p-value of 0.000. The significance of the squared customer term indicates that the relationship between customer scale and cost is not strictly linear. The customer scale variables should therefore be interpreted jointly rather than separately. In simple terms, the models allow the cost impact of customer scale to vary between smaller and larger utilities, rather than assuming that a 1% increase in customers has the same proportional impact for every utility in the sample. For CL&P, given its 2024 customer count of approximately 1.29 million, a 10% increase in its customers is associated with approximately a 10.0% increase in total cost and a 10.7% increase in capital cost. • Network density has a negative relationship with capital cost. Network density is measured as customers per circuit. In the capital cost model, the coefficient is approximately -0.000055 with a p-value of 0.037, indicating that customer density is statistically significant at the 95% London Economics International LLC 717 Atlantic Avenue, Suite 1A Boston, MA 02111 www.londoneconomics.com
As listed on the current system
Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: Julia Frayer [26-05-10]