Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Files2

Search terms highlighted
Eversource rate increase is on 4 pages of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
4 pages match
  1. Page 16 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 14 of 33 1 future retirement pattern of the assets. 2 3 Q. Do other factors also support your conclusion that Mr. Garrett’s estimate is unreasonable? 4 A. Yes. The Company’s actual pole inspection and replacement practices further illustrate 5 why such a long tail is not reasonable. CL&P inspects its pole population on a 10-year 6 cycle, which was recently shortened from 15 years. Poles are replaced following 7 failures and are also retired for reliability, reconductoring and capacity reasons. As 8 poles reach older ages, these inspection and replacement activities increase the 9 likelihood that deteriorated or otherwise inadequate poles will be identified and retired. 10 Thus, even if an individual pole can remain physically capable of providing service for 11 a very long period, it is not reasonable to assume that a significant portion of the pole 12 population will avoid the various forces of retirement and remain in service to the 13 extremely advanced ages represented by Mr. Garrett’s L0 curve. 14 15 Q. You have shown the unusual characteristics for the L0 curve. Are there even worse issues with the O3 survivor curve? 16 A. Yes. In my 20-year career, I do not recall an example in which an O3 curve reasonably 17 describes the survivor characteristics of utility property. This can be seen not only in 18 an extremely long tail but also in the results in Mr. Garrett’s workpapers. His own 19 calculations show that the 25-O3 curve expects the remaining life of property to 20 increase with age and for the remaining life to barely decline with age until assets are 21 more than 50 years old. 22
  2. Page 17 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 15 of 33 1 These unusual phenomena can be seen in the chart below, which shows the remaining 2 lives by age from several of the Iowa curves, each with a 25-year average service life. 3 For each type of curve, even the L0 curves discussed above, the remaining life 4 generally declines with age. 5 However, the O3 actually increases from age 15 to age 5 35. Figure 2: Remaining Life by Age for 25-O3 Survivor Curve 6 30 25 Remaining Life 20 15 10 5 0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101105109 Age O3 7 L0 L3 R1 R3 S0 S3 I note here that the low-mode L curves are also outliers when compared to most other curve types in that the remaining life declines very slowly at older ages. However, the degree to which they are outliers is masked by the rather extreme irregularity of the O3 curve. 5
  3. Page 18 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 16 of 33 1 Mr. Garrett’s workpapers similarly show unusual results, indicating that the 2 reasonableness of the O3 curve warranted further consideration. For example, older 3 property has a greater estimated remaining life than younger property for many ages. 4 Exhibit DJG-26, pages 20–21, reports a remaining life of 23.76 years for the 2015 5 vintage, 23.94 years for the 2010 vintage, 24.22 years for the 2005 vintage, and 24.36 6 years for the 2000 vintage, all as of December 31, 2025. Thus, his calculation assigns 7 the 2000 vintage to a longer remaining life than the 2015 vintage, even though the 8 former has already been in service for 15 additional years. I do not find these results 9 reasonable for utility property. 10 11 Q. What do you believe Mr. Garrett’s proposed L0 and O3 curves reveal about his analysis? 12 A. Mr. Garrett’s use of these curves suggest that his analysis relies almost entirely on the 13 outputs generated by his software without sufficient consideration of whether the 14 resulting estimates are reasonable and appropriate, particularly where those estimates 15 resulted in lower depreciation expense. As I discussed previously, his inconsistent 16 application of concepts, combined with these unusual curve selections, shows that he 17 has not taken a balanced or considered approach to developing his recommendations. D. Account by Account Discussion 18 19 20 Q. Why do you disagree with Mr. Garrett’s proposed 53-L0 survivor curve for Account 364.00? 21 A. Mr. Garrett’s proposed curve does not reasonably represent the expected retirement 22 characteristics of utility poles. As discussed in the previous section, Mr. Garrett’s
  4. Page 19 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 17 of 33 1 proposal is based on selecting an unusual L0 curve type. Both his estimate and mine 2 are similar through 60 years of age but my estimate more accurately reflects the 3 maximum life indicated by a considered interpretation of the statistical data. In contrast 4 as Figure 1 illustrated, the L0 curve selected by Mr. Garrett has an exceptionally long 5 tail and projects that some poles will remain in service beyond 120 years. The L0 curve 6 is very uncommon for utility pole accounts. Mr. Garrett has not identified any other 7 utility for which this curve was used for poles. 8 9 Q. Why do you disagree with Mr. Garrett’s proposed 55-L0 survivor curve for Account 367.00? 10 A. His recommendation presents the same fundamental problem as his L0 selection for 11 poles: an exceptionally long tail that does not reasonably represent the expected 12 retirement characteristics of the property. Mr. Garrett increases the Company’s 13 proposed average service life from 50 years to 55 years and changes the dispersion 14 from R0.5 to L0. The increase in average service life he recommends is driven entirely 15 by changing to an L0 curve. 16 Figure 3 shows the resulting extension of projected survival to advanced ages. Similar 17 to Account 364.00, Mr. Garrett extrapolates a long tail beyond the indications of the 18 historical data. A more reasonable trend from the actual data would extrapolate to a 19 maximum life of close to 100 years. Mr. Garrett’s projection would assume extending 20 the lives of certain assets by an additional 50 years beyond this age, resulting in 21 conductors remaining in service to approximately 150 years of age. I do not believe it
  5. Page 20 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 18 of 33 1 is reasonable to assume that conductors could remain in service for 150 years while 2 continuing to provide safe and reliable electric service to customers. 3 Figure 3: Account 367.00 - Underground Conductors and Devices 4 5 Underground conductors and devices are subject to both physical and functional forces 6 of retirement. In my experience, L0 is very uncommon for this type of property, and I 7 do not consider the extended survival represented by Mr. Garrett’s curve a reasonable 8 prospective expectation. 9
  6. Page 21 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 19 of 33 1 2 Q. Why do you disagree with Mr. Garrett’s proposed 25-O3 survivor curve for Account 373.00? 3 A. I have discussed the problems with the O3 curve in detail in the previous section. 4 Figure 4 below also shows that Mr. Garrett has not considered more recent data for this 5 account. Additional information and analysis, which Mr. Garrett does not appear to 6 have considered, supports the Company’s proposal. The Company began converting 7 its street lighting to LED technology in 2016, resulting in a change in the composition 8 and expected retirement characteristics of this account. The operating characteristics of 9 the newer LED fixtures are also different from the street lighting equipment they 10 replaced. The LED light source cannot be replaced independently, such that 11 replacement of the LED requires replacement of the fixture, and the Company expects 12 LED fixtures to have lives in approximately the 15-year range. 13 Accordingly, additional weight should be placed on the more recent retirement 14 experience. The overall experience band includes substantial experience associated 15 with the older street lighting technology, while the more recent experience increasingly 16 reflects the LED fixtures that will drive future retirements. Therefore, the 2001–2025 17 experience band should be considered along with the overall band when estimating the 18 future retirement characteristics of the account. As Figure 4 illustrates, the more recent 19 experience supports a shorter service life and provides additional support for the 20 Company’s proposed 18-L0 curve.
  7. Page 22 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 20 of 33 1 Figure 4: Account 373.00 - Street Lighting and Signal Systems 2 3 4 5 Q. Why do you disagree with Mr. Garrett’s proposed 52-R0.5 survivor curve for Account 365.00? 6 A. Mr. Garrett’s recommendation extends the projected retirement pattern beyond the 7 maximum life indicated by the life analysis. Both the Company and Mr. Garrett select 8 an R0.5 dispersion, but he increases the average service life from the Company’s 9 proposed 46 years to 52 years. As Figure 5 illustrates, that change extends the tail of 10 his curve beyond the approximately 90-year maximum life indicated by the analysis.
  8. Page 23 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 21 of 33 1 Figure 5: Account 365.00 - Overhead Conductors and Devices 2 3 The historical data for this account does not have a pattern that closely follows a single 4 Iowa curve throughout the observed experience. That limitation makes it particularly 5 important to consider the reasonableness of the entire projected retirement pattern, 6 including its endpoint. My recommendation matches the data better than Mr. Garrett’s 7 through age 40 and declines to 0 percent surviving at the approximate age that the 8 historical data does the same. Moreover, Mr. Garrett’s estimate does not fit the data 9 particularly well for any range, but it does project that assets will survive longer than 10 the maximum life indicated by the historical data.
  9. Page 24 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 22 of 33 1 Company information regarding the actual forces of retirement for this account further 2 supports my recommendation. Reliability and capacity are important drivers of 3 overhead conductor retirements, and the Company has an ongoing program to replace 4 older copper conductor. As conductors reach advanced ages, physical survival is not 5 the only factor affecting whether they remain in service and it is common for utilities 6 to have programmatic replacement of older assets which tend to limit the maximum 7 life of assets in an account. There are several reasons to replace older conductor, 8 including condition, reliability, capacity or other system needs. These considerations 9 further support a retirement pattern that approaches zero surviving at a reasonable 10 maximum life rather than continuing to extrapolate survival beyond the maximum life 11 indicated by the historical analysis. 12 13 Q. Why do you disagree with Mr. Garrett’s proposed 82-year average service life for Account 366.00? 14 A. In my experience, an 82-year average service life is outside the typical industry range 15 for electric utility underground conduit. The Company’s proposed 75-year average 16 service life already recognizes that conduit is long-lived property. Mr. Garrett’s 17 recommendation extends that estimate by another seven years while retaining the same 18 R1.5 dispersion. Figure 6 compares the two curves. 19 approximately one third of the account will be in service more than 100 years and 20 around 15 percent will be in service more than 120 years. These are very long lives, 21 and there is not historical data demonstrating that a large share of assets will be in 22 service for that long. My recommendation is already for a fairly long service life. Mr. Mr. Garrett projects that
  10. Page 25 of 35

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 23 of 33 1 2 Garrett has not provided justification for an even longer life. Figure 6: Account 366.00 - Underground Conduit 3 E. Account 370.48 Meters 4 5 Q. What does Mr. Garrett propose for Account 370.48, Meters? 6 A. Mr. Garrett proposes to retain the Company’s Iowa survivor curves and net salvage 7 estimates but remove the shorter-term probable retirement date used in the Company’s 8 depreciation calculation. He instead calculates remaining lives using a mass-property 9 approach. Mr. Garrett acknowledges that the Company currently plans to replace its

As listed on the current system

Prefiled testimony: 11/18/2026 - Sponsor: TBD / Witness: NED W. ALLIS [26-05-10]

This filing on the current system (opens in a new tab)