Page 21 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 19 of 33 1 2 Q. Why do you disagree with Mr. Garrett’s proposed 25-O3 survivor curve for Account 373.00? 3 A. I have discussed the problems with the O3 curve in detail in the previous section. 4 Figure 4 below also shows that Mr. Garrett has not considered more recent data for this 5 account. Additional information and analysis, which Mr. Garrett does not appear to 6 have considered, supports the Company’s proposal. The Company began converting 7 its street lighting to LED technology in 2016, resulting in a change in the composition 8 and expected retirement characteristics of this account. The operating characteristics of 9 the newer LED fixtures are also different from the street lighting equipment they 10 replaced. The LED light source cannot be replaced independently, such that 11 replacement of the LED requires replacement of the fixture, and the Company expects 12 LED fixtures to have lives in approximately the 15-year range. 13 Accordingly, additional weight should be placed on the more recent retirement 14 experience. The overall experience band includes substantial experience associated 15 with the older street lighting technology, while the more recent experience increasingly 16 reflects the LED fixtures that will drive future retirements. Therefore, the 2001–2025 17 experience band should be considered along with the overall band when estimating the 18 future retirement characteristics of the account. As Figure 4 illustrates, the more recent 19 experience supports a shorter service life and provides additional support for the 20 Company’s proposed 18-L0 curve.Page 22 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 20 of 33 1 Figure 4: Account 373.00 - Street Lighting and Signal Systems 2 3 4 5 Q. Why do you disagree with Mr. Garrett’s proposed 52-R0.5 survivor curve for Account 365.00? 6 A. Mr. Garrett’s recommendation extends the projected retirement pattern beyond the 7 maximum life indicated by the life analysis. Both the Company and Mr. Garrett select 8 an R0.5 dispersion, but he increases the average service life from the Company’s 9 proposed 46 years to 52 years. As Figure 5 illustrates, that change extends the tail of 10 his curve beyond the approximately 90-year maximum life indicated by the analysis.Page 23 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 21 of 33 1 Figure 5: Account 365.00 - Overhead Conductors and Devices 2 3 The historical data for this account does not have a pattern that closely follows a single 4 Iowa curve throughout the observed experience. That limitation makes it particularly 5 important to consider the reasonableness of the entire projected retirement pattern, 6 including its endpoint. My recommendation matches the data better than Mr. Garrett’s 7 through age 40 and declines to 0 percent surviving at the approximate age that the 8 historical data does the same. Moreover, Mr. Garrett’s estimate does not fit the data 9 particularly well for any range, but it does project that assets will survive longer than 10 the maximum life indicated by the historical data.Page 24 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 22 of 33 1 Company information regarding the actual forces of retirement for this account further 2 supports my recommendation. Reliability and capacity are important drivers of 3 overhead conductor retirements, and the Company has an ongoing program to replace 4 older copper conductor. As conductors reach advanced ages, physical survival is not 5 the only factor affecting whether they remain in service and it is common for utilities 6 to have programmatic replacement of older assets which tend to limit the maximum 7 life of assets in an account. There are several reasons to replace older conductor, 8 including condition, reliability, capacity or other system needs. These considerations 9 further support a retirement pattern that approaches zero surviving at a reasonable 10 maximum life rather than continuing to extrapolate survival beyond the maximum life 11 indicated by the historical analysis. 12 13 Q. Why do you disagree with Mr. Garrett’s proposed 82-year average service life for Account 366.00? 14 A. In my experience, an 82-year average service life is outside the typical industry range 15 for electric utility underground conduit. The Company’s proposed 75-year average 16 service life already recognizes that conduit is long-lived property. Mr. Garrett’s 17 recommendation extends that estimate by another seven years while retaining the same 18 R1.5 dispersion. Figure 6 compares the two curves. 19 approximately one third of the account will be in service more than 100 years and 20 around 15 percent will be in service more than 120 years. These are very long lives, 21 and there is not historical data demonstrating that a large share of assets will be in 22 service for that long. My recommendation is already for a fairly long service life. Mr. Mr. Garrett projects thatPage 25 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 23 of 33 1 2 Garrett has not provided justification for an even longer life. Figure 6: Account 366.00 - Underground Conduit 3 E. Account 370.48 Meters 4 5 Q. What does Mr. Garrett propose for Account 370.48, Meters? 6 A. Mr. Garrett proposes to retain the Company’s Iowa survivor curves and net salvage 7 estimates but remove the shorter-term probable retirement date used in the Company’s 8 depreciation calculation. He instead calculates remaining lives using a mass-property 9 approach. Mr. Garrett acknowledges that the Company currently plans to replace itsPage 26 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 24 of 33 1 existing meters with AMI meters in the short-term 6 but argues that the Company’s use 2 of a probable retirement date accelerates depreciation recovery beyond what is 3 supported by a normal mass-property analysis. He further recommends waiting for the 4 AMI program to progress and actual retirement experience to develop, at which point 5 PURA could recognize shorter remaining lives in a future depreciation study or rate 6 proceeding. 7 Q. Do you agree with Mr. Garrett’s proposed treatment? 8 A. No. His recommendation is fundamentally inconsistent with the prospective nature of 9 depreciation. The purpose of estimating service lives and remaining lives is to forecast 10 when the property currently in service is expected to retire. We should not wait until 11 an expected retirement has occurred before incorporating it into the depreciation 12 estimate. Such a delay could result in the customers of tomorrow paying for the 13 equipment used by the customers of today. If Mr. Garrett believes a mass property 14 approach is most appropriate for the account, he would need to incorporate the planned 15 retirement of meters into his recommended survivor curve and average service life. He 16 did not do so. 17 18 Q. Why should the planned AMI conversion be reflected in the depreciation calculation? 19 A. Depreciation should reflect the period over which the property is expected to provide 20 service. A planned technology replacement can shorten that period even where the 6 See Garrett at 78:15-16.Page 27 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 25 of 33 1 existing equipment remains physically capable of operating. Obsolescence and 2 management decisions concerning replacement are forces of retirement, just as 3 deterioration and failure are forces of retirement. Mr. Garrett’s proposal would result 4 in future customers paying the unrecovered costs of legacy meters in addition to the 5 cost of new meters. This would be inequitable. 6 7 Q. Do you agree that PURA should wait until the AMI program progresses before recognizing its effect on depreciation? 8 A. No. Mr. Garrett acknowledges that the Company currently plans to replace its existing 9 meters in the short-term, which means he proposes to recover the costs of these assets 10 over a longer time than they will be in service. His recommendation to calculate 11 depreciation without that expected retirement date and to recognize any shortening of 12 remaining lives in a future depreciation study or rate proceeding if the retirement 13 experience develops would defer cost recovery to future customers who will have to 14 pay for retired meters and the new AMI meters. 15 16 Q. Do you agree that PURA should wait until the AMI program progresses before recognizing its effect on depreciation? 17 A. No. Mr. Garrett acknowledges that the Company currently plans to replace its existing 18 meters with AMI meters in the short-term. Nevertheless, he recommends calculating 19 depreciation without that expected retirement date and recognizing shorter remaining 20 lives in a future study or rate proceeding if the retirement experience develops. Mr. 21 Garrett’s approach is not appropriate because it ignores known information concerning 22 the expected retirement of the legacy meters. Historical retirement data cannot reflectPage 28 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 26 of 33 1 a replacement program that has not yet occurred, and waiting for that experience to 2 develop would extend remaining lives beyond the period the meters are expected to 3 provide service. This would leave costs unrecovered at retirement and shift those costs 4 to future customers who are also paying for the replacement AMI meters. 7 Moreover, 5 delaying recognition of the meter retirement date does not avoid the cost; it merely 6 compresses recovery into fewer years and creates a larger future increase in 7 depreciation expense. Recognizing the short-term probable retirement date now more 8 appropriately aligns cost recovery with the expected service period and provides a more 9 gradual recovery. If the AMI program timing changes, the remaining life calculation 10 can be updated accordingly. 11 12 Q. Have other regulators recognized the need to align legacy meter depreciation with planned AMI replacement? 13 A. Yes. There are examples of cost recovery for AMI programs. For example, the 14 Company’s affiliates used a similar probable retirement date and approach in 15 Massachusetts. 8 16 The Florida Public Service Commission addressed Florida Power & Light Company’s 17 meters that were being made obsolete by AMI by establishing capital recovery 18 schedules. Under that mechanism, “the investment and associated reserve of 19 installations facing near-term retirement are separated out as sub-accounts, and the As outlined in Exhibit CLP-AMI-1, the Company is also proposing to securitize stranded meter costs, as permitted by Public Act No. 25-173, Section 10. 8 Massachusetts Order D.P.U. 22-22 (pp.186) 7Page 29 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 27 of 33 1 unrecovered net amounts are amortized over the period of their remaining service to 2 the public.” The Commission explained the consequences of failing to align recovery 3 with an early retirement (p. 23 of Order No. PSC-10-0153-FOF-EI): 4 5 6 7 8 9 10 11 12 If assets retire earlier than the average life of the group without recovery being afforded, a negative reserve component is created. The negative reserve component translates into a positive rate base element. From the Company’s standpoint, it will continue to earn a return on this nonexistent plant over the life of the group. From the ratepayers’ standpoint, they will continue paying for plant no longer providing service until the situation is corrected. Negative reserve amounts are non-life related net investments that we have historically corrected as fast as practicable to remedy the existing intergenerational inequity. 13 The shorter-term probable retirement date aligns the remaining life of the legacy meters 14 with their planned replacement, allowing the remaining investment to be recovered 15 through depreciation while the meters are still providing service. This avoids an 16 unrecovered balance at retirement, prevents future customers from paying for assets no 17 longer in service, and eliminates the need for a separate recovery mechanism. 18 Other regulators have similarly recognized the need to recover the remaining 19 investment in meters replaced through AMI programs. The North Carolina 20 Commission provided for recovery of Duke Energy Progress’s 9 and Duke Energy 21 Carolinas’ 10 legacy meter investment, as did the Nevada 11, California 12 and South 22 Carolina 13 commissions likewise provided for recovery of meters retired through 9 10 11 12 13 Order in North Carolina Docket Nos. E-2, Sub 1131, 1142, 1103 and 1153 Order in North Carolina Docket Nos. E-7, Sub 1146, 819, 1152 and 1110 Nevada Order Dockets 10-02009, 10-03022 and 10-03023 California Decision 11-05-018 South Carolina Joint Proposed Order Docket No. 2020-125-EPage 30 of 35
Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-DEPRECIATION-REBUTTAL-1 November 18, 2026 Page 28 of 33 1 advanced metering programs. 2 Mr. Garrett’s approach would do the opposite. Removing the probable retirement date 3 would extend the assumed lives of the legacy meters beyond their planned replacement, 4 leaving costs unrecovered at retirement and shifting those costs to future customers 5 who will also be paying for the new AMI meters. 6 IV. NET SALVAGE ESTIMATES 7 Q. Please summarize Mr. Garrett’s net salvage recommendations. 8 A. Mr. Garrett recommends changes to the Company’s proposed net salvage estimates for 9 several distribution and general plant accounts. For most of the disputed accounts, he 10 selects an estimate halfway between the currently approved estimate and the 11 Company’s proposal, which he supports as incorporating the concept of “gradualism.” 12 For example, for Account 364.00, Poles, Towers and Fixtures, the current estimate is 13 negative 90 percent, the Company proposes negative 100 percent, and Mr. Garrett 14 recommends negative 95 percent. 15 However, he only applies “gradualism” when the result is to reduce depreciation 16 expense. He takes a different approach for Accounts 365.00 and 369.00, selecting 17 negative 19 percent and negative 57 percent, respectively, based on recent historical 18 experience. Table 2 compares the current estimates, the Company’s proposals, and Mr. 19 Garrett’s recommendations with the overall and most recent five-year historical net 20 salvage averages.