Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Application supplement

Exhibit CLP-Additions-6 Folder 2 - 4 of 4

Files463

Search terms highlighted
Eversource rate increase is on 1 page of the text below, highlighted. Go to the first matchClear highlighting

Text of 3-CD02260 Supplemental_Redacted.pdf

Extracted from the file · 30 pages, 23 without text · 2,041 characters

Text of 3-CD02259 Supplemental_Redacted.pdf

Extracted from the file · 29 pages, 22 without text · 1,400 characters

Words on different pages
1 page match

Text of 3-CD02203 Supplemental_Redacted.pdf

Extracted from the file · 56 pages, 24 without text · 5,516 characters

Words on different pages

Text of 3-CD02182 Supplemental_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 425 characters

Text of 3-CD02176 Supplemental_Redacted.pdf

Extracted from the file · 22 pages, 17 without text · 1,797 characters

Text of 3-CD02172 Supplemental_Redacted.pdf

Extracted from the file · 46 pages, 30 without text · 7,598 characters

Text of 3-CD02150 Supplemental_Redacted.pdf

Extracted from the file · 37 pages, 21 without text · 5,599 characters

Text of 3-CD02123 Supplemental_Redacted.pdf

Extracted from the file · 19 pages, 14 without text · 4,145 characters

Text of 3-CD02122 Supplemental_Redacted.pdf

Extracted from the file · 29 pages, 18 without text · 2,901 characters

Text of 3-CD02121 Supplemental_Redacted.pdf

Extracted from the file · 20 pages, 14 without text · 3,176 characters

Text of 3-CD02078 Supplemental_Redacted.pdf

Extracted from the file · 25 pages, 12 without text · 3,884 characters

Text of 3-CD02058 Supplemental_Redacted.pdf

Extracted from the file · 44 pages, 25 without text · 6,744 characters

Text of 3-CD02046 Supplemental_Redacted.pdf

Extracted from the file · 50 pages, 23 without text · 14,066 characters

Text of 3-CD02040 Supplemental_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 812 characters

Text of 3-CD02031 Supplemental_Redacted.pdf

Extracted from the file · 38 pages, 17 without text · 2,728 characters

Text of 3-CD02030 Supplemental_Redacted.pdf

Extracted from the file · 30 pages, 16 without text · 4,025 characters

Text of 3-CD02017 Supplemental_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 204 characters

Text of 3-CD02016 Supplemental_Redacted.pdf

Extracted from the file · 29 pages, 15 without text · 2,190 characters

Text of 3-CD01999 Supplemental_Redacted.pdf

Extracted from the file · 25 pages, 13 without text · 1,921 characters

Text of 3-CD01986 Supplemental_Redacted.pdf

Extracted from the file · 24 pages, 17 without text · 2,920 characters

Text of 3-CS00417 Supplememental Redacted.pdf

Extracted from the file · 6 pages, 5 without text · 1,444 characters

Words on different pages
  1. Page 12 of 25

    Supplement Authorization Form 9. References References 1. 10. Attachments (One Line Diagrams, Images, etc.) Attachment Included in Submittal? A. TripSaver Replacement Locations YES B. Partial Funding PAF YES 12 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  2. Page 13 of 25

    Supplement Authorization Form Attachment - A: TripSaver Replacement Locations* Figure 2: Eastern TripSaver Replacement Locations *Locations are subject to change based on field conditions and other variables between now and construction 13 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  3. Page 14 of 25

    Supplement Authorization Form Attachment - B: Partial Funding PAF Project Title: 2025 TripSaver Eastern BCA Project Number: CD02771 Date Prepared: 10/31/2025 Company: Eversource CT Organization: Distribution Engineering Project Category: SMART SWITCHES PROGRAM Project Initiator: Project Type: Specific Initiating Organization: Distribution Capital Investment part of original Op Plan: Yes Project Manager: Emergency Related Request? No Facility Type (check all that apply): Project Sponsor: ☐ PTF ☐ non-PTF ☒ Distribution ☐ N/A (General Plant) Required in service date: 12/31/2025 NWS Excludable: ☐ Yes ☒ No Total Capital Request: $843.8K Authorization Type: Partial Funding 1. Executive Summary This project was created to replace fused lateral locations with TripSaver units in order to reduce the number of outages caused by transient type events (tree, animal, lightning, patrolled nothing found). For the Eastern Division, there are a total of 76 locations. Division: Eastern District(s): Danielson, East Hampton, Madison, New London AWCs Town(s): Brooklyn, Canterbury, Chester, Clinton, Colchester, Columbia, East Haddam, Essex, Franklin, Glastonbury, Griswold, Groton, Guilford, Haddam, Hebron, Killingly, Killingworth, Ledyard, Lyme, Marlborough, Montville, New London, North Stonington, Old Lyme, Plainfield, Preston, Putnam, Salem, Voluntown, Waterford, Windham, Woodstock 14 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  4. Page 15 of 25

    Supplement Authorization Form 2. Project Cost Summary Note: Dollar values are in thousands. Capital Costs Year 2025 Year 2026 Year 2027+ Total Internal Labor and Construction Equipment 46.0 0.0 0.0 46.0 Outside Services 94.4 0.0 0.0 94.4 Materials 438.1 0.0 0.0 438.1 Removals 50.4 0.0 0.0 50.4 Other 2.2 0.0 0.0 2.2 Risk and Contingency 0.0 0.0 0.0 0.0 631.1 0.0 0.0 631.1 Indirect/Overheads (including benefits) 202.7 0.0 0.0 202.7 Capitalized interest or AFUDC, if any 10.0 0.0 0.0 10.0 212.7 0.0 0.0 212.7 Total Gross Capital Costs 843.8 0.0 0.0 843.8 Customer Contribution 0.0 0.0 0.0 0.0 Total Net Capital Project Costs 843.8 0.0 0.0 843.8 Direct Capital Costs Subtotal – Direct Costs Indirect Capital Costs Subtotal – Indirect Costs 15 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  5. Page 16 of 25

    Supplement Authorization Form 3. Technical Justification Background, Project Need/Justification, and Project Scope a. Background A TripSaver is a self−powered, electronically controlled, single−phase, cutout−mounted vacuum, interrupter recloser. The TripSaver is designed to eliminate the sustained interruption that occurs when a lateral fuse cutout operates in response to a transient fault. It also can eliminate momentary circuit interruptions that occur when a substation circuit breaker or source−side line recloser would otherwise trip to prevent a lateral fuse cutout from operating in response to a transient fault. b. Project Need This project is required as the 76 fused lateral locations would benefit from a TripSaver replacement according to reliability metrics in Eastern CT. The fused lateral locations targeted for replacement with TripSavers were based on historical outage and interruption data. Based on the standardized recloser improvement indices, 60% of customer interruption and 50% of customer minutes saved were utilized. Total Events Events Saved Total Customer Mins 255 38 3,457,119 Customer Mins Saved 397,569 Total Customers Effected 8,981 Customer Int Saved 3,078 Figure 1: Eastern TripSaver Customer Reliability Indices 16 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  6. Page 17 of 25

    Supplement Authorization Form c. Project Scope This project proposes one option, Option 1, as the preferred option. This option looks to replace these fused lateral locations with TripSaver units. The scope of Option 1 is as follows: AWC Danielson East Hampton Madison New London Town(s) BROOKLYN CANTERBURY GRISWOLD KILLINGLY PLAINFIELD PUTNAM VOLUNTOWN WOODSTOCK COLCHESTER COLUMBIA EAST HADDAM FRANKLIN GLASTONBURY HEBRON MARLBOROUGH WINDHAM CHESTER CLINTON ESSEX GUILFORD HADDAM KILLINGWORTH GROTON LEDYARD LYME MONTVILLE NEW LONDON NORTH STONINGTON OLD LYME PRESTON SALEM WATERFORD WOs 1 6 2 3 1 2 1 1 2 2 2 1 2 3 2 4 1 2 1 2 5 1 2 7 1 1 2 7 1 2 3 3 17 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  7. Page 18 of 25

    Supplement Authorization Form For more details on each location, see the Attachments section. Major Materials: • • • 1ph TripSaver Locations: 71 2ph TripSaver Locations: 0 3ph TripSaver Locations: 5 Qty Size Body 3 19 2 7 15 25K 40K 40K 65K 65K 80K 80K 80K 100K 100K 100K 140K 140K 40A 40A 100A 40A 100A 40A 100A 200A 40A 100A 200A 100A 200A 1 7 12 8 6 6 86 Stock Code (as of 10/2025) 620630 622560 620609 622559 620607 622558 622467 620606 622557 622468 620605 622764 620603 18 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  8. Page 19 of 25

    Supplement Authorization Form 4. Alternatives Considered Design Criteria Option 1 – Eastern TripSavers 2 – NWS Required to meet project need Optimizes locations with TripSaver X Provides alternative source during outage X Authorization Type Partial Partial Capital Cost $843,825 $179,293,233 Expense Cost $36,972 $7,855,767 Total Cost $880,797 $187,149,000 Total Cost / CM Saved $2.22 $470.73 Total Cost / CI Saved $286.16 $60,802.14 Preferred Option X NWS: The NWS was not selected as it is not cost efficient compared to Option 1. The NWS estimate was calculated at $2M per MWh based on the two lowest of three contractor bids received in Connecticut. Per location, it was assumed the battery would support up to 4 hours and that each location would require further sectionalization to create the battery recovery zone. Doing nothing here is not recommended as new TripSaver units along these lateral locations can offer greater reliability and mitigate outages that would otherwise occur with a fuse in its place. 19 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  9. Page 20 of 25

    Supplement Authorization Form 5. Project Schedule Milestone/Phase Name Estimated Date Partial Approval October 31, 2025 100% Detailed Engineering Completion November 1, 2025 Fully Funded November 7, 2025 Construction Start November 10, 2025 Project Completion December 31, 2025 6. Regulatory Decisions N/A 7. Codes and Standards Codes and Standards 4. DSEM 06.713 – Overhead System Protection & Design Philosophy 5. DSEM 10.431 – TripSaver II General 6. WMS 09.10-234 – Operation Instruction for the S&C TripSaver II 8. Risk and Contingencies Contingencies: 24% contingency was added for 2025 work. This contingency accounts for any risks that are unknown and do not have mitigation plans. 20 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3
  10. Page 21 of 25

    Supplement Authorization Form Risk Event Risk Horizon Likelihood of Occurrence Risk Mitigation Actual cost higher than estimated due to scope changes. 2025 Medium Included contingency costs in the funding request. Perform detailed Field Analysis and walk down in project development to avoid potential issues. Customer Permission / Siting Council / Municipal approvals 2025 Low Design to minimize customer impact. Project Preplanning and customer/community outreach. Internal construction resources not available to perform the work. 2025 Low Plan internal resources to perform the work. Use competitive bidding to ensure lowest outside labor cost. Internal engineering resources not available to perform the work. 2025 Low Plan internal resources to perform the work. Use competitive bidding to ensure lowest outside labor cost. Materials Shortage or long lead times 2025 Low Pre-order long lead time material; minimize the use of nonstandard and non-stocked material. Storm delays 2025 Low If storm activity delays work, we may be forced to use external resources. System abnormal configuration 2025 Low Schedule work to minimize system abnormal time. Install temporary bypasses/equipment if system will be abnormal for extended periods. Wetlands / Environmentally sensitive area 2025 Low Use of mats and specialty equipment, only work during certain times of the year. 21 Refer to Distribution Capital Project Approval Process JA-AM-2001-B, Rev.5 Refer to Distribution Capital Project Supplement Process JA-AM-2001-C, Rev.3

Text of 3-CD02770 Supplemental Redacted.pdf

Extracted from the file · 25 pages · 24,184 characters

Text of 3-CD02769 Supplemental Redacted.pdf

Extracted from the file · 25 pages · 24,626 characters

Text of 3-CD02736 Supplemental Redacted.pdf

Extracted from the file · 15 pages, 9 without text · 940 characters

Text of 3-CD02595 Supplemental_Redacted.pdf

Extracted from the file · 19 pages, 11 without text · 3,088 characters

Text of 3-CD02588 Supplemental_Redacted.pdf

Extracted from the file · 25 pages, 15 without text · 4,410 characters

Text of 3-CD02571 Supplemental Redacted.pdf

Extracted from the file · 21 pages, 14 without text · 3,519 characters

Text of 3-CD02567 Supplemental Redacted.pdf

Extracted from the file · 32 pages, 18 without text · 4,756 characters

Text of 3-CD02564 Supplemental Redacted.pdf

Extracted from the file · 28 pages, 15 without text · 5,843 characters

Text of 3-CD02498 Supplemental _Redacted.pdf

Extracted from the file · 17 pages, 12 without text · 1,979 characters

Text of 3-CD02453 Supplemental_Redacted.pdf

Extracted from the file · 22 pages, 15 without text · 1,984 characters

Text of 3-CD02449 Supplemental_Redacted.pdf

Extracted from the file · 10 pages, 6 without text · 3,316 characters

Text of 3-CD02444 Supplemental_Redacted.pdf

Extracted from the file · 12 pages, 7 without text · 3,600 characters

Text of 3-CD02426 Supplemental_Redacted.pdf

Extracted from the file · 31 pages, 21 without text · 6,385 characters

Text of 3-CD02415 Supplemental_Redacted.pdf

Extracted from the file · 21 pages, 9 without text · 2,247 characters

Text of 3-CD02385 Supplemental_Redacted.pdf

Extracted from the file · 24 pages, 18 without text · 1,107 characters

Text of 3-CD02368 Supplemental_Redacted.pdf

Extracted from the file · 33 pages, 25 without text · 3,319 characters

Text of 3-CD02359 Supplemental_Redacted.pdf

Extracted from the file · 23 pages, 18 without text · 2,190 characters

Text of 3-CD02351 Supplemental_Redacted.pdf

Extracted from the file · 19 pages, 18 without text · 434 characters

Text of 3-CD02325 Supplemental_Redacted.pdf

Extracted from the file · 18 pages, 16 without text · 2,787 characters

Text of 3-CD02296 Supplemental_Redacted.pdf

Extracted from the file · 13 pages, 10 without text · 1,416 characters

Text of 3-CS00571 Supplemental Redacted.pdf

Extracted from the file · 5 pages · 8,230 characters

Text of 3-XTRANCT01 Supplemental Redacted.pdf

Extracted from the file · 3 pages · 4,816 characters

Text of 3-MCRO22NM Supplemental Redacted.pdf

Extracted from the file · 3 pages · 3,064 characters

Text of 3H820023P PAF Form #1_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 3,486 characters

Text of 3-FTDESENG APPROVAL Redacted.pdf

Extracted from the file · 1 page · 1,158 characters

Text of 3-CTTRNSUB Supplemental Redacted.pdf

Extracted from the file · 4 pages · 6,457 characters

Scanned pages of 3-CS00590 Approval Redacted.pdf

Read by machine from a scan · 1 page · may contain errors, especially in numbers

Text of 4- CD01364 PAF Supplement 2_Redacted.pdf

Extracted from the file · 16 pages, 12 without text · 2,403 characters

Scanned pages of 5-CD01261 Approval 2_Redacted.pdf

Read by machine from a scan · 1 page · may contain errors, especially in numbers

Text of 4-CTTRNSUB Approval Redacted.pdf

Extracted from the file · 1 page · 936 characters

Text of 4-CD02176 Supplemental_Redacted.pdf

Extracted from the file · 26 pages, 17 without text · 2,405 characters

Text of 4-CD01958 Supplemental_Redacted.pdf

Extracted from the file · 37 pages, 23 without text · 1,985 characters

Text of 4-CD01915 PAF Supplement 2_Redacted.pdf

Extracted from the file · 63 pages, 39 without text · 7,204 characters

Text of 4-CD01615 PAF Supplement 2_Redacted.pdf

Extracted from the file · 16 pages, 11 without text · 1,441 characters

Text of 4-CD01451 PAF Supplement 2_Redacted.pdf

Extracted from the file · 39 pages, 22 without text · 3,399 characters

Text of 4-CD01225 PAF Supplement 2_Redacted.pdf

Extracted from the file · 189 pages, 30 without text · 12,161 characters

Text of 22753 PAF Form #1_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,025 characters

Text of 5-CD02176 Supplemental_Redacted.pdf

Extracted from the file · 30 pages, 19 without text · 2,573 characters

Text of CPTLAUVL PAF Form #1 Redacted.pdf

Extracted from the file · 3 pages · 5,179 characters

As listed on the current system

Supplement for New App [Filed: 09/25/2026]

This filing on the current system (opens in a new tab)