Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Application supplement

Exhibit CLP-Additions-6 Folder 3

Files344

Search terms highlighted
Eversource rate increase is on 19 pages across 19 files of the text below, highlighted. Go to the first matchClear highlighting

Text of 2-103353 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-103353 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-102118 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-102118 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-102118 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-19733 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-18742 PAF_Redacted.pdf

Extracted from the file · 6 pages, 4 without text · 4,386 characters

Text of 2-2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-18CGVE11 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 3 pages · 3,164 characters

Text of 2- CD00412 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Words on different pages
Words on different pages
Words on different pages

Text of 1-VLT_CORR (CDDKANNL) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 18 pages, 9 without text · 16,578 characters

Text of 1-VLT_CORR (CDDKANNL) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 22 pages, 6 without text · 36,839 characters

Text of 1-LVEHPUR CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 2,242 characters

Text of 1-LVEHPUR CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 7 pages, 2 without text · 6,091 characters

Text of 1-LVEHPUR CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 8,295 characters

Text of 1-LVEHPUR CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 9 pages, 3 without text · 9,731 characters

Text of 1-LN_RLBLTY CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 204 pages, 45 without text · 359,550 characters

Text of 1-LN_RLBLTY CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 199 pages, 36 without text · 342,307 characters

Text of 1-LN_RLBLTY CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 244 pages, 37 without text · 504,097 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 113 pages, 24 without text · 204,528 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 92 pages, 30 without text · 145,347 characters

Text of 1-LN_RELO CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 86 pages, 17 without text · 150,597 characters

Text of 1-LN_RELO CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 94 pages, 17 without text · 174,937 characters

Text of 1-LN_RELO CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 102 pages, 21 without text · 189,243 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 82 pages, 25 without text · 98,054 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 91 pages, 39 without text · 91,868 characters

Text of 1-LIGHTNG CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 670 pages, 32 without text · 1,396,582 characters

Text of 1-LIGHTNG CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 595 pages, 67 without text · 1,124,319 characters

Text of 1-LIGHTNG CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 417 pages, 103 without text · 603,838 characters

Text of 1-LIGHTNG (D7DA24) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 293 pages, 48 without text · 458,489 characters

Text of 1-LIGHTNG (D7DA24) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 461 pages, 83 without text · 704,276 characters

Text of 1-IT1DWANA CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 8 pages, 4 without text · 4,914 characters

Text of 1-IT1DWANA CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 10 pages, 4 without text · 7,148 characters

Text of 1-IT1DWANA CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 12 pages, 4 without text · 13,903 characters

Text of 1-INSCLMCST CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 505 pages, 94 without text · 636,387 characters

Text of 1-INSCLMCST CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 575 pages, 33 without text · 1,053,525 characters

Text of 1-INSCLMCST CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 553 pages, 110 without text · 806,786 characters

Words on different pages
  1. Page 191 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 2M722459 Total 2M722570 2M722570 Total 2M722588 2M722588 Total 2M722602 2M722602 Total 2M722610 2M722610 Total 2M722652 2M722652 Total 2M722665 2M722665 Total 2M722667 2M722667 Total 2M722719 2M722719 Total 2M722760 2M722760 Total 2M722812 2M722812 Total 2M722831 2M722831 Total 2M722861 2M722861 Total 2M722875 2M722875 Total 2M722890 2M722890 Total 2M722919 2M722919 Total 2M722933 2M722933 Total 2M722938 2M722938 Total 2M722944 2M722944 Total 2M722955 2M722955 Total 2M723044 2M723044 Total 2M723064 2M723064 Total 2M723073 2M723073 Total 2M723074 2M723074 Total 2M723076 Description POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET AND HARDWARE, CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, 3 5/8 IN X 4 5/8 IN, 8 FT LG, FIBERGLASS, FOR ALLEY ARM CONSTRUCTION, 20 EA/FULL PALLET POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, LUMINAIRE,DECORATIVE, POST TOP, MH, TYPE III CUTOFF REFRACTOR, 100 W, ALL BLACK ARCHITECTURAL TOP AN POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED LUMINAIRE, HPS, POST TOP TRADITIONAL, 120 V, 100 W, 9500 LUMINOUS, NPF REACTOR, W/ FULL CUTOFF, TYPE HANDHOLE, ROUND, 8 IN ID, 19 IN H, BODY: PLASTIC, W/ PLASTIC COVER MARKED ELECTRIC AND PENTA BOLT BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 CONTAINMENT,OIL, W/ VELCRO CLOSURE, FOR TRANSFORMER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, CABLE, INSULATED, AERIAL, AAC, TRIPLEX, 4/0 AWG, 600 V, W/ 2/0 AWG ALLOY NEUTRAL, ARCA, P/O, THEN SW CABLE, INSULATED, 3CT, 4/0 AWG, 600 V, W/ 2/0 AWG NEUTRAL, UNILAY COMPRESSED, XLPE INSULATED, AL, 42 CONDUIT,ELECTRICAL, 3 IN, 10 FT LG, PVC, SCH 40, ONE BELLED END CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI CABLE, INSULATED, 2CT, #4 AWG, STRANDED, 600 V, BLACK W/ YELLOW STRIPES, XLPE INSULATED, AL, FOR STR POLE, UTILITY, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED LUMINAIRE, HPS, HORIZONTAL, 120 V, 70 W, 5800 LUMINOUS, NPF REACTOR, W/ CUTOFF, TYPE 2 Values Sum of Quantity Sum of Amount $1,273.98 $349.21 $349.21 $205.81 $981.57 $199.80 $287.64 $1,674.82 $52.00 $52.00 $66.91 $66.91 $236.55 $236.55 $430.88 $95.56 $526.44 $474.38 $474.38 $67.60 $67.60 $717.98 $717.98 $474.38 $474.38 $513.83 $98.73 $612.56 $24.28 $207.52 $109.41 $46.86 $388.07 $357.19 $357.19 $74.88 $74.88 $66.91 $66.91 $52.00 $52.00 $99.84 $99.84 $270.12 $270.12 $39.69 $18.52 $58.21 $54.91 $54.91 $349.21 $349.21 $95.88 $95.88 $475.53 $98.11 $573.64 $15.44 $576.63 $94.17
  2. Page 192 of 491

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  3. Page 193 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 2M723450 Total 2M723451 2M723451 Total 2M723460 2M723460 Total 2M723479 2M723479 Total 2M723537 2M723537 Total 2M723580 2M723580 Total 2M723619 2M723619 Total 2M723666 2M723666 Total 2M723688 2M723688 Total 2M723693 2M723693 Total 2M723751 2M723751 Total 2M723758 2M723758 Total 2M723807 2M723807 Total 2M723905 Description Values Sum of Quantity SWITCH,DISCONNECT, 600 A, 65 KA MOM PEAK, 25 KV, 125 KV BIL , 1 PH, AIR, VERTICAL MOUNT, INSULATED, CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET AND HARDWARE, LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 250 W, 30000 LUMINOUS, AUTO-REGULATOR, W/ CUTOFF, TYPE POLE, STREETLIGHT, 30 FT LG, ANCHOR BASE, AL, W/ SINGLE BRACKET FITTING, 1/2 IN X 13 TAPPED HOLE FOR BRACKET,LUMINAIRE, TRUSSED, 2 IN X 8 FT, AL, STREET LIGHT, AL POLE MOUNTING POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI ARRESTER,SURGE, LIGHTNING, DISTRIBUTION CLASS, 6 KV, 5.1 KV MCOV, W/ 30 IN #4 FLEXIBLE GROUND LEAD A CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ARRESTER,SURGE, LIGHTNING, DISTRIBUTION CLASS, 6 KV, 5.1 KV MCOV, W/ 30 IN #4 FLEXIBLE GROUND LEAD A POLE, STREETLIGHT, 30 FT LG, ANCHOR BASE, AL, W/ SINGLE BRACKET FITTING, 1/2 IN X 13 TAPPED HOLE FOR BRACKET,LUMINAIRE, TRUSSED, 2 IN X 8 FT, AL, STREET LIGHT, AL POLE MOUNTING FLOODLIGHT, LUMINAIRE, HPS, FULL CUTOFF, 120 V, 400 W, 50K LUMINOUS BRACKET,LUMINAIRE, FLOODLIGHT, 4-1/2 IN TO 6-1/2 IN DIA, AL, W/ METAL POLE MOUNTING LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 150 W, 16000 LUMINOUS, NPF REACTOR, W/ CUTOFF, TYPE 2 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR POLE, 50 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET AND HARDWARE, CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER BRACKET,TANGENT, SPACER, 24 IN, DI, HOT DIP GALV, USE: MESSENGER BRACKET FOR 25KV SPACER, BM24 BAR, ANTI-SWAY, 24 IN, W/ CABLE SPACERS ON TANGENT CABLES, POLYETHYLENE CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE TERMINATOR,CABLE, #1-350, #2, #2-1/0, 0.840 - 1.38 IN CABLE DIA, 25/35 KV, W/O PIN TAP OR LUG, AL/CU CONDUIT,ELECTRICAL, 3 IN DIA, PVC, SCH 80, 2.9 IN ID, STRAIGHT CONDUIT,ELECTRICAL, 3 IN, 10 FT LG, PVC, SCH 40, ONE BELLED END CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 BRACKET, CUTOUT AND ARRESTER, 12 IN W, 48 IN LG, FIBERGLASS, W/ ALUMINIUM OR DUCTILE IRON END FITTI CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI CONTROL,RECLOSER, CLOSING COIL, LOW VOLTAGE, ELECTRONICALLY, LOOP SCHEME, W/ SCADA READY, TYPE: FORM CABLE ASSEMBLY, CONTROL, POWER, #12, 2/C, 2 CONNECTOR, 40 FT LG, BOTTOM ENTRANCE, W/ ARMOR COVERING, 0 0 0 0 0 Sum of Amount $202.43 $377.98 $201.66 $579.64 $126.52 $823.24 $292.29 $1,242.05 $350.55 $135.97 $207.58 $95.27 $789.37 $211.07 $211.07 $133.02 $96.23 $229.25 $823.24 $295.13 $374.18 $244.67 $115.19 $1,852.41 $199.54 $79.16 $543.85 $201.66 $224.94 $1,249.15 $24.04 $68.50 $83.46 $17.69 $193.69 $133.02 $112.47 $96.32 $341.81 $11.83 $32.74 $34.57 $8.47 $48.57 $8.42 $4.98 $47.42 $197.00 $438.34 $52.25 $180.43 $112.34 $88.26 $871.62 $66.52 $426.26 $96.32 $589.10 $8,747.72 $939.51
  4. Page 194 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 2M723905 2M723905 Total 2M723935 2M723935 Total 2M723937 2M723937 Total 2M724005 2M724005 Total 2M724016 2M724016 Total 2M724030 2M724030 Total 2M724045 2M724045 Total 2M724133 2M724133 Total 2M724260 2M724260 Total 2M724278 2M724278 Total 2M724309 2M724309 Total 2M724325 2M724325 Total 2M724358 2M724358 Total 2M724389 2M724389 Total 2M724408 2M724408 Total 2M724428 Description CABLE ASSEMBLY, CONTROL, VOLTAGE SENSING, #16, 4/C, 2 CONNECTOR, 40 FT LG, W/ ARMOR COVERING, FOR CO Values Sum of Quantity POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE TERMINATOR,CABLE, #2-4/0, 0.637 - 1.12 IN CABLE DIA, 15 KV, W/O PIN TAP OR LUG, AL/CU, FOR INDOOR/OU ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 CABLE, BARE, ACSR/AW, 1/0 AWG, 6/1 STR, RAVEN BRACKET, CUTOUT AND ARRESTER, 12 IN W, 48 IN LG, FIBERGLASS, W/ ALUMINIUM OR DUCTILE IRON END FITTI CABLE, INSULATED, UG, 3-1/C, #1 AWG, 15 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177698 CONDUIT,ELECTRICAL, 4 IN DIA, 10 FT LG, PVC, SCH 80, ONE BELLED END CONDUIT,ELECTRICAL, 4 IN, 10 FT LG, PVC, SCH 40, BELLED END FUSE,POWER, 65 A, K, 15 KV, 22400 A ASYM, S&C, COOPER TYPE CMUSMU-20 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB CONDUIT,ELECTRICAL, 3 IN DIA, PVC, SCH 80, 2.9 IN ID, STRAIGHT CONDUIT,ELECTRICAL, 3 IN, 10 FT LG, PVC, SCH 40, ONE BELLED END CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET AND HARDWARE, JP MORGAN CHASE BANK CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED MOUNT,CLUSTER, TRANSFORMER, MEDIUM, 5/8 X 2-1/2 IN, 37.5-167 KVA, AL, W/ SIX - SQ.HD. BOLTS, HEX NUT CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI LUMINAIRE,DECORATIVE, PREMIUM, MH, 120 V, 100W, VICTORIAN, BLACK POWDER COAT POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 HANDHOLE, LAWN, 30 IN LG, 17 IN W, 17 IN DP, HIGH DENSITY POLYETHYLENE, W/ COVER MARKED ELECTRIC, CABLE, INSULATED, 3CT, 4/0 AWG, 600 V, W/ 2/0 AWG NEUTRAL, UNILAY COMPRESSED, XLPE INSULATED, AL, 42 CONDUIT,ELECTRICAL, 4 IN DIA, 10 FT LG, PVC, SCH 80, ONE BELLED END CONDUIT,ELECTRICAL, 4 IN, 10 FT LG, PVC, SCH 40, BELLED END HANDHOLE, LAWN, 30 IN LG, 17 IN W, 17 IN DP, HIGH DENSITY POLYETHYLENE, W/ COVER MARKED ELECTRIC, POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 0 0 0 0 0 Sum of Amount $722.62 $10,409.85 $349.30 $349.30 $136.99 $429.84 $566.83 $430.88 $51.17 $224.71 $183.74 $39.23 $87.46 $390.59 $21.95 $26.29 $343.17 $1,799.19 $67.98 $410.76 $478.74 $348.06 $25.12 $373.18 $17.10 $20.23 $37.33 $203.95 $430.88 $183.20 $196.21 $37.16 $95.56 $1,146.96 $339.92 $876.67 $173.24 $95.56 $1,485.39 $438.34 $95.56 $533.90 $714.02 $714.02 $348.06 $135.97 $25.83 $95.56 $605.42 $24.04 $112.34 $136.38 $75.77 $75.77 $0.00 $0.00 $0.00 $0.00 $0.00 $348.06
  5. Page 195 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 2M724428 2M724428 Total 2M724492 2M724492 Total 2W321255 2W321255 Total 2W420643 Description CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI Values Sum of Quantity CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 4 LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 150 W, 16000 LUMINOUS, NPF REACTOR, W/ CUTOFF, TYPE 2 0 SPACER, CABLE, HENDRIX - 46KV, POLYETHYLENE W/CONDUCTOR CLAMPS 2W420643 Total 2W520348 2W520348 Total 2W520488 2W520488 Total 2W520607 2W520607 Total 2W521162 2W521162 Total 2W521381 2W521381 Total 2W521435 2W521435 Total 2W521660 2W521660 Total 2W521688 2W521688 Total 2W521731 ARRESTER, SURGE, LIGHTNING, DISTRIBUTION CLASS, 12 KV MOV, POLYMER, 10.2 MCOV, W/ANIMAL GUARD & 30 " #4 COV FLEXIBLE GRD LEAD BRACKET, CUTOUT & ARRESTER / FIBERGLASS 12 IN, FERR / ALUM FITTINGS W/ MOUNTING BOLTS BAR, ANTI-SWAY, CABLE SPACERS ON TANGENT CABLES, POLYETHYLENE, 24 IN BRACKET, TANGENT/ HENDRIX, 24 IN W/MC-2 MESSENGER CLAMP SPACER, CABLE, HENDRIX - 46KV, POLYETHYLENE W/CONDUCTOR CLAMPS CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS, 54 EACH PER PALLET CROSSARM, FIBERGLASS, 5FT - 7 IN TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 25 EA/ PALLET TO CORRECT INVT RETURNS AT 0 $ 0 0 0 0 ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, PENTA TREATED CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET POLE, PREMIUM DECORATIVE LIGHT, ALUMINUM, FLUTED, 14 FT HEIGHT, VERDE FINISH POLE AND METAL BASE, ROUND BASE 7"-14" BOLT CIRCLE POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB 2W521731 Total 2W521744 0 POLE, SYP, 35 FT, CL 2, CCA 2W521744 Total 2W521763 2W521763 Total 2W521798 2W521798 Total 2W521916 2W521916 Total 2W522029 2W522029 Total 2W522058 2W522058 Total 2W620008 LUMINAIRE, HPS, HORIZONTAL, 120 V, 70 W, 5800 LUMINOUS, NPF REACTOR, W/ CUTOFF, TYPE 2 POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS BRACKET, CUTOUT & ARRESTER / FIBERGLASS 12 IN, FERR / ALUM FITTINGS W/ MOUNTING BOLTS, PHASE OUT - USE 24" (180800) IN NH POLE, SYP, 45 FT, CL 2, CCA HANDHOLE, LAWN, HIGH DENSITY POLYETHYLENE, 17 IN W, 30 IN L, 17 IN D, GREEN, COVER MARKED "ELECTRIC" HANDHOLE, LAWN, HIGH DENSITY POLYETHYLENE, 10 IN W, 14 IN L, 12 IN D, GREEN, COVER MARKED "ELECTRIC" 0 POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET ARRESTER, SURGE, LIGHTNING, DISTRIBUTION CLASS, 12 KV MOV, POLYMER, 10.2 MCOV, W/ANIMAL GUARD & 30 " #4 COV FLEXIBLE GRD LEAD POLE, SYP, 45 FT, CL 2, CCA Sum of Amount $67.98 $95.56 $511.60 $112.34 $112.34 $115.19 $115.19 -$8.56 $24.09 $15.53 $124.58 $49.68 $34.60 $155.38 $57.94 $422.18 $96.20 $70.20 $77.89 $244.29 $0.14 $0.14 -$3,329.64 -$3,329.64 $8.14 $345.30 $353.44 $96.31 $96.31 $1,010.06 $1,010.06 $12.95 $12.95 $348.06 $25.12 $373.18 -$1.30 -$296.98 -$298.28 $96.87 $96.87 $345.58 $23.51 $62.13 $22.87 $57.82 $511.91 $96.04 $137.72 $49.63 $492.03 $775.42 $75.44 -$49.60 $25.84 $357.19 $357.19 $96.36 $184.36 $490.12
  6. Page 196 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 2W620008 2W620008 Total 2W620056 2W620056 Total 2W620199 2W620199 Total 2W620354 2W620354 Total 2W620357 2W620357 Total 2W620371 2W620371 Total 2W620373 2W620373 Total 2W620449 2W620449 Total 2W620755 2W620755 Total 2W620813 2W620813 Total 2W620881 2W620881 Total 2W620962 2W620962 Total 2W620964 2W620964 Total 3H221806 3H221806 Total 3H420506 3H420506 Total 3H421955 3H421955 Total 3H422622 3H422622 Total 3H422661 3H422661 Total 3H520140 Description SWITCH, DISCONNECT, OUTDOOR, AIR, SINGLE-INSULATOR, 25 KV, 600A, LOADBUSTER, VERTICAL, 65 KA PK WITHSTAND, 1 PH, 125 KVBIL CONNECTOR, STUD, FOR SWITCHES & DISCONNECTS, COPPER BRONZE, TIN PLATED, 600 AMP, 2 HOLE NEMA PAD Values Sum of Quantity 0 POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CABLE, COVERED, 1/C, 556 KCMIL, 19 STR, 175 MILS POLY, AL CABLE, INSULATED, AERIAL, AAC, TRIPLEX, 1/0 AWG, 7 STR, 600 V, W/ 1/0 AWG 7 STR ALLOY NEUTRAL, GAMMA ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 CROSSARM, DISTRIBUTION, DEADEND, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET AND HARDWARE, POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FI POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 12 KV, 10.2 MCOV, W/ 30 IN # 4 POLE, SYP, 45 FT, CL 2, CCA ANCHOR, SINGLE HELIX, SOCKET DRIVE, 8000#, 10 IN BRACKET, TANGENT/ HENDRIX, 24 IN W/MC-2 MESSENGER CLAMP BRACKET, ANGLE, EXTENDED TAP, HENDRIX, SPACER CABLE SINGLE CIRCUIT, 5-35 KV, 38-1/2 IN L, GALV STEEL 0 0 BRACKET, LUMINAIRE, STREET LIGHT, FOR AL OR FIBERGLASS POLE, ALUMINUM, 2INX8FT, TRUSSED POLE, STREETLIGHT, AL, 30 FT LENGTH, SINGLE BRACKET FITTING, W/ 1/2" X 13 TAPPED HOLE FOR GROUND, ANCHOR BASE, RATED FOR 90 MPH WIND PER SPC LUMINAIRE, METAL HALIDE, ROADWAY (HORIZONTAL), FULL CUTOFF, PULSE START, 120V, 400W, 20000 LUMENS POLE, SYP, 35 FT, CL 2, CCA ANCHOR, SINGLE HELIX, SOCKET DRIVE, 8000#, 10 IN CROSSARM, FIBERGLASS, 10 FT TANGENT, 3-5/8 X 4-5/8 IN, WITH CENTER MOUNT BRACKET, 49 EA/PALLET LUMINAIRE, HPS ROADWAY, HORIZONTAL, CUTOFF, 120 V, 150 W, 16000 L, NPF REACTOR, TY2 BRACKET, LUMINAIRE, STREET LIGHT, WOOD POLE MOUNTING, GALVANIZED STEEL WITH GROUND LUG, 1-1/4 INX10 FT, SINGLE GUY, ANSI C136.13 CLASS D RAT POLE, SYP, 35 FT, CL 2, CCA POLE, UTILITY, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CABLE, INSULATED, AERIAL, AAC, TRIPLEX, #2 AWG, 600 V, W/ #2 AWG 6201 ALLOY NEUTRAL, XLPE INSULATED, CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET CROSSARM, FIBERGLASS, 10 FT TANGENT, 3-5/8 X 4-5/8 IN, WITH CENTER MOUNT BRACKET, 49 EA/PALLET POLE, UTILITY, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 250 W, 30000 LUMINOUS, AUTO-REGULATOR, W/ CUTOFF, TYPE CABLE, INSULATED, BARE, AERIAL, AAC, DUPLEX, #6 AWG, 7 STR, 600 V, PARALLEL LAY, W/ BARE CABLE #6 AW POLE, SYP, 45 FT, CL 2, CCA ANCHOR, SINGLE HELIX, SOCKET DRIVE, 8000#, 10 IN CROSSARM, FIBERGLASS, 8 FT LG, 3 5/8 IN X 4 5/8 IN, W/ALLEY ARM BRACE, FULL PALLET QUANTITY OF 20 EACH LUMINAIRE, HPS ROADWAY, HORIZONTAL, CUTOFF, 120 V, 250 W, 27500 LUM, AUTOREGULATED, TY3 LUMINAIRE, HPS ROADWAY, HORIZONTAL, CUTOFF, 120 V, 250 W, 27500 LUM, AUTOREGULATED, TY3 LUMINAIRE, HPS, HORIZONTAL, CUTOFF, 120 V, 400 W, REGULATED BALLAST, FLAT GLASS LENS POLE, 45 FT LG, CLASS 1, SOUTHREN YELLOW PINE, CCA TREATED CONNECTOR, COMPRESSION, CRAB INSULATED, COPPER, 4/0, 4 WAY POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 0 0 0 Sum of Amount $376.32 $1.27 $1,148.43 $431.92 $304.23 $36.22 $185.53 $403.32 $1,361.22 $490.79 $95.88 $586.67 $438.34 $438.34 $24.04 $410.76 $61.23 $496.03 $19.25 $0.99 $78.23 $177.40 $275.87 $262.52 $867.02 $171.62 $1,301.16 $304.14 $25.11 $4.36 $3.34 $4.32 $341.27 $304.99 $304.99 $290.83 $71.10 $361.93 $96.29 $109.92 $206.21 $289.20 $137.09 $35.96 $462.25 $486.17 $25.16 $237.82 $749.15 $119.01 $119.01 $119.01 $119.01 $158.55 $158.55 $518.93 $518.93 $116.22 $116.22 $410.76
  7. Page 197 of 491

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  8. Page 198 of 491

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  9. Page 199 of 491

    No text on this page. It may be a picture of a page, such as a scan or a chart.
  10. Page 200 of 491

    funding project INSCLMCST Cost Element Category Material month number (blank) accounting work order 3H720209 3H720209 Total 3H720210 3H720210 Total 3H720215 3H720215 Total 3H720241 3H720241 Total 3H720242 3H720242 Total 3H720262 3H720262 Total 3H720263 3H720263 Total 3H720266 3H720266 Total 3H720270 3H720270 Total 3H720272 3H720272 Total 3H720291 3H720291 Total 3H720292 3H720292 Total 3H720296 3H720296 Total 3H720396 3H720396 Total 3H720402 3H720402 Total 3H720406 3H720406 Total 3H720435 3H720435 Total 3H720448 Description POLE, SYP, 40 FT, CL 2, CCA POLE, STREETLIGHT F/POST TOP LUM, FIBERGLASS (BROWN), 18 FT LG LUMINAIRE, HPS, POST TOP TRADITIONAL, FULL CUTOFF, 120V, 70W, 6300L, BLACK FINISH, NPF REACTOR, TYPE II POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED POLE, UTILITY, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 150 W, 16000 LUMINOUS, NPF REACTOR, W/ CUTOFF, TYPE 2 CABLE, INSULATED, BARE, AERIAL, AAC, DUPLEX, #6 AWG, 7 STR, 600 V, PARALLEL LAY, W/ BARE CABLE #6 AW POLE, SYP, 40 FT, CL 2, CCA CABLE, INSULATED, AERIAL, XLPE, 600, AAC, #6, 7 STR, DUPLEX, PARALLEL LAY, BARE #6 7 STR ALLOY NEUTRAL, VIZSLA/XLP CONDUIT, ELECTRICAL, PVC, 3 IN, 10 FT LG, SCH 80, 2.900 ID CONDUIT, ELECTRICAL, PVC, 3 IN, 10 FT, SCHEDULE 40, BELLED ONE END LUMINAIRE, HPS ROADWAY, HORIZONTAL, CUTOFF, 120 V, 250 W, 27500 LUM, AUTOREGULATED, TY3 CABLE, INSULATED, DB, XLP, 600 V, AL, 1/0 AWG, STR, 3 CT, #2 AWG NEUT, BRENAU, 48 IN FLANGE DIA X 40 IN WIDTH REEL CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS, 54 EACH PER PALLET POLE, SYP, 45 FT, CL 2, CCA CROSSARM, FIBERGLASS, 10 FT DEADEND, 3-5/8 X 4-5/8, WITH CENTER MOUNT BRACKET & HARDWARE CROSSARM, FIBERGLASS, 10 FT TANGENT, 3-5/8 X 4-5/8 IN, WITH CENTER MOUNT BRACKET, 49 EA/PALLET POLE, 40 FT LG, CLASS 1, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS, 54 EACH PER PALLET INDICATOR, FAULT, UNDERGROUND-SINGLE PHASE, 450AMP, 8 HR RESET TIME BRACKET, CABLE, TERMINATOR MOUNTING, ALUM, 0.75 THRU 3.00 IN D CABLE BRACKET, CUTOUT & ARRESTER / FIBERGLASS 12 IN, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CONNECTOR, ELBOW, LOADBREAK, ALUM, #1 STR AWG, 260 MIL, 0.830-1.100 IN, 25 KV, 200 A TERMINATOR, CABLE, INDOOR/OUTDOOR, #1-350 AL/CPR 25KV, #2 CPR 30KV, #2-1/0 AL 35KV, .840 - 1.38 IN CABLE DIA, W/O PIN TAP OR LUG CONNECTOR, JUNCTION, LOADBREAK, 25 KV, 4-WAY, W/SS ADJ BKT F/FLAT OR CURVED WALL MOUNT SWITCHGEAR, DISTRIBUTION, PAD 3-PHASE 4-WAY, 25KV, 200A LBK JCT, 125KV BIL, 10KA SYM, 13KA ASYM CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS, 54 EACH PER PALLET CROSSARM, FIBERGLASS, 10 FT TANGENT, 3-5/8 X 4-5/8 IN, WITH CENTER MOUNT BRACKET, 49 EA/PALLET LUMINAIRE, HPS, HORIZONTAL (ROADWAY), 120 V, 250 W, 30000 LUMINOUS, AUTO-REGULATOR, W/ CUTOFF, TYPE POLE, STREETLIGHT F/POST TOP LUM, FIBERGLASS (BROWN), 18 FT LG LUMINAIRE, HPS, POST TOP TRADITIONAL, FULL CUTOFF, 120V, 100W, 9500L, GLASS REFRACTOR, BLACK FINISH, NPF REACTOR, TYPE II CABLE, INSULATED, AERIAL TRIPLEX, XLP, 600V, #2 AAC CONDUCTOR, #2 6201 ALLOY NEUTRAL, SHRIMP/XLP, 500' COIL, NSTAR CAT ID 8815 POLE, STREETLIGHT F/POST TOP LUM, FIBERGLASS (BROWN), 18 FT LG LUMINAIRE, HPS, POST TOP TRADITIONAL, FULL CUTOFF, 120V, 100W, 9500L, GLASS REFRACTOR, BLACK FINISH, NPF REACTOR, TYPE II CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS ARRESTER, SURGE, LIGHTNING, DISTRIBUTION CLASS, 18 KV, POLYMER, MOV, 15.3 KV MCOV, W/ANIMAL GUARD & 30" #4 FLEXIBLE GROUND LEAD POLE, SYP, 40 FT, CL 2, CCA POLE, STREETLIGHT, FIBERGLASS-ROUND, 18 FT LG, BLACK, F/ POST TOP LUM LUMINAIRE, HPS, POST TOP TRADITIONAL, FULL CUTOFF, 120V, 70W, 6300L, BLACK FINISH, NPF REACTOR, TYPE II CROSSARM, FIBERGLASS, 8 FT TANGENT, 3-5/8 X 4-5/8 IN, CENTER MOUNT BRACKET, 49 EA/PALLET CUTOUT, FUSED, OPEN, LOADBUSTER, SILICONE, 25 KV, 150 KV BIL, 100 A, 12 KA IC ASYM, W/LOADBUSTER HOOKS, 54 EACH PER PALLET CABLE, INSULATED, AERIAL TRIPLEX, XLP, 600V, #2 AAC CONDUCTOR, #2 6201 ALLOY NEUTRAL, SHRIMP/XLP, 500' COIL, NSTAR CAT ID 8815 Values Sum of Quantity Sum of Amount $395.52 $395.52 $187.18 $167.67 $354.85 $364.40 $364.40 $290.02 $94.59 $20.65 $405.26 $380.84 $25.56 $406.40 $14.68 $20.37 $118.96 $40.61 $194.62 $212.08 $485.20 $202.95 $109.78 $1,010.01 $413.17 $413.17 $70.70 $131.18 $17.35 $49.86 $37.00 $97.68 $260.16 $2,530.32 $3,194.25 -$203.68 $424.17 $109.78 $330.27 $120.50 $120.50 $187.11 $174.36 $361.47 $42.43 $42.43 $187.11 $174.36 $361.47 $70.46 $70.68 $380.91 $522.05 $140.76 $167.67 $308.43 $96.31 $70.67 $166.98 $31.82

Text of 1-INSCLMCST (CTINS24) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 499 pages · 908,456 characters

Text of 1-GXTD21 CS & Closing Report_Redacted.pdf

Extracted from the file · 21 pages, 5 without text · 26,915 characters

Text of 1-GXTD20 CS & Closing Report_Redacted.pdf

Extracted from the file · 18 pages, 6 without text · 20,865 characters

Text of 1-GXTD19 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 2,908 characters

Text of 1-GXENG CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,362 characters

Text of 1-GXCOTRBL CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 4,108 characters

Text of 1-GXCOTRBL CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,540 characters

Text of 1-GXCOTRBL CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 4,286 characters

Text of 1-GECNCLP CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,165 characters

Text of 1-ETTCF21 CS & Closing Report_Redacted.pdf

Extracted from the file · 31 pages, 6 without text · 38,094 characters

Text of 1-ETTCF20 CS & Closing Report_Redacted.pdf

Extracted from the file · 24 pages, 4 without text · 29,216 characters

Text of 1-ETTCF19 CS & Closing Report_Redacted.pdf

Extracted from the file · 28 pages, 10 without text · 25,052 characters

Text of 1-ETTCF18 CS & Closing Report_Redacted.pdf

Extracted from the file · 21 pages, 5 without text · 24,956 characters

Text of 1-ETTCF17 CS & Closing Report_Redacted.pdf

Extracted from the file · 17 pages, 7 without text · 16,534 characters

Text of 1-ETT2017 CS & Closing Report_Redacted.pdf

Extracted from the file · 102 pages, 10 without text · 92,080 characters

Text of 1-ETT2016 CS & Closing Report_Redacted.pdf

Extracted from the file · 65 pages, 16 without text · 89,859 characters

Text of 1-ETR2021 CS & Closing Report_Redacted.pdf

Extracted from the file · 217 pages, 49 without text · 168,057 characters

Text of 1-ETR2020 CS & Closing Report_Redacted.pdf

Extracted from the file · 217 pages, 46 without text · 171,105 characters

Text of 1-ETR2019 CS & Closing Report_Redacted.pdf

Extracted from the file · 197 pages, 38 without text · 168,113 characters

Text of 1-ETR2018 CS & Closing Report_Redacted.pdf

Extracted from the file · 193 pages, 38 without text · 154,165 characters

Text of 1-EMRGNTLN CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 953 pages, 84 without text · 1,795,343 characters

Text of 1-EMRGNTLN CS & Closing Report 2019_Part2_Redacted.pdf

Extracted from the file · 616 pages, 78 without text · 995,151 characters

Text of 1-EMRGNTLN CS & Closing Report 2019_Part1_Redacted.pdf

Extracted from the file · 750 pages, 103 without text · 1,403,033 characters

Text of 1-EMRGNTLN CS & Closing Report 2018_Part2_Redacted.pdf

Extracted from the file · 528 pages, 195 without text · 635,082 characters

Text of 1-EMRGNTLN CS & Closing Report 2018_Part1_Redacted.pdf

Extracted from the file · 750 pages, 170 without text · 1,187,926 characters

Text of 1-EMRGNTLN CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 1,178 pages, 263 without text · 1,930,158 characters

Text of 1-EMRGNTLN (CDEMANNL) CS & Closing Report 2020_Part2_Redacted.pdf

Extracted from the file · 455 pages, 129 without text · 593,721 characters

Text of 1-EMRGNTLN (CDEMANNL) CS & Closing Report 2020_Part1_Redacted.pdf

Extracted from the file · 750 pages, 139 without text · 1,267,663 characters

Text of 1-EFO_TLS CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 15 pages, 6 without text · 16,794 characters

Text of 1-EFO_TLS CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 12 pages, 5 without text · 16,453 characters

Text of 1-DT7C CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,066 characters

Text of 1-DT7C CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,078 characters

Text of 1-DT7C CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 10 pages, 2 without text · 63,534 characters

Text of 1-DSEQ21 CS & Closing Report_Redacted.pdf

Extracted from the file · 46 pages, 17 without text · 44,468 characters

Text of 1-DSEQ20 CS & Closing Report_Redacted.pdf

Extracted from the file · 8 pages, 3 without text · 7,513 characters

Text of 1-DSEQ CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 13 pages, 4 without text · 16,519 characters

Text of 1-DSEQ CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 17 pages, 5 without text · 25,281 characters

Text of 1-DSEQ CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 25 pages, 6 without text · 52,950 characters

Text of 1-DSEQ CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 23 pages, 9 without text · 28,799 characters

Text of 1-DSEQ CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 16 pages, 5 without text · 22,297 characters

Text of 1-DSCN21 CS & Closing Report_Redacted.pdf

Extracted from the file · 55 pages, 12 without text · 61,698 characters

Text of 1-DSCN20 CS & Closing Report_Redacted.pdf

Extracted from the file · 9 pages, 5 without text · 7,519 characters

Text of 1-DSCN CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 18 pages, 5 without text · 22,473 characters

Text of 1-DSCN CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 28 pages, 9 without text · 36,554 characters

Text of 1-DSCN CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 29 pages, 9 without text · 42,697 characters

Text of 1-DB_CABLE CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 203 pages, 66 without text · 307,639 characters

Text of 1-DB_CABLE CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 117 pages, 44 without text · 160,299 characters

Text of 1-DB_CABLE CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 98 pages, 28 without text · 190,517 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 201 pages, 45 without text · 276,403 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 231 pages, 25 without text · 449,921 characters

Text of 1-CTTRN21 CS & Closing Report_Redacted.pdf

Extracted from the file · 11 pages, 3 without text · 13,105 characters

Text of 1-CTTRN20 CS & Closing Report_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 4,429 characters

Text of 1-CTTRN19 CS & Closing Report_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 20,761 characters

Text of 1-CTTRN18 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,610 characters

Text of 1-CTROW17 CS & Closing Report_Redacted.pdf

Extracted from the file · 15 pages, 3 without text · 12,533 characters

Text of 1-CTRMTR17 CS & Closing Report_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 8,323 characters

Text of 1-CTMTR21 CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 5,890 characters

Text of 1-CTMTR20 CS & Closing Report_Redacted.pdf

Extracted from the file · 18 pages, 8 without text · 21,352 characters

Text of 1-CTMTR19 CS & Closing Report_Redacted.pdf

Extracted from the file · 6 pages, 4 without text · 6,215 characters

Text of 1-CTMTR18 CS & Closing Report_Redacted.pdf

Extracted from the file · 17 pages, 8 without text · 20,687 characters

Text of 1-CTMTR17 CS & Closing Report_Redacted.pdf

Extracted from the file · 12 pages, 6 without text · 14,369 characters

Text of 1-CTFT2021 CS & Closing Report_Redacted.pdf

Extracted from the file · 9 pages, 3 without text · 9,209 characters

Text of 1-CTFT2020 CS & Closing Report_Redacted.pdf

Extracted from the file · 11 pages, 3 without text · 14,590 characters

Text of 1-CTEDVH21 CS & Closing Report_Redacted.pdf

Extracted from the file · 26 pages, 3 without text · 30,119 characters

Text of 1-CTEDVH20 CS & Closing Report_Redacted.pdf

Extracted from the file · 24 pages, 2 without text · 25,121 characters

Text of 1-CSTMER CS & Closing Report 2020_Part2_Redacted.pdf

Extracted from the file · 656 pages, 184 without text · 1,241,840 characters

Text of 1-CSTMER CS & Closing Report 2020_Part1_Redacted.pdf

Extracted from the file · 750 pages, 143 without text · 925,443 characters

Text of 1-CSTMER CS & Closing Report 2019_Part2_Redacted.pdf

Extracted from the file · 745 pages, 117 without text · 1,311,127 characters

Text of 1-CSTMER CS & Closing Report 2019_Part1_Redacted.pdf

Extracted from the file · 750 pages · 1,818,090 characters

Text of 1-CSTMER CS & Closing Report 2018_Part2_Redacted.pdf

Extracted from the file · 701 pages, 50 without text · 1,928,204 characters

Text of 1-CSTMER CS & Closing Report 2018_Part1_Redacted.pdf

Extracted from the file · 750 pages, 7 without text · 1,170,967 characters

Text of 1-CSTMER CS & Closing Report 2017_Part2_Redacted.pdf

Extracted from the file · 573 pages, 116 without text · 1,377,910 characters

Text of 1-CSTMER CS & Closing Report 2017__Part1_Redacted.pdf

Extracted from the file · 750 pages, 70 without text · 1,191,670 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2021_Part2_Redacted.pdf

Extracted from the file · 708 pages, 93 without text · 1,527,022 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2021_Part1_Redacted.pdf

Extracted from the file · 750 pages, 56 without text · 1,006,998 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2020_Part1_Redacted.pdf

Extracted from the file · 750 pages, 143 without text · 925,443 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2020_Part2_Redacted.pdf

Extracted from the file · 656 pages, 184 without text · 1,241,840 characters

Text of 1-CDMHANNL CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 3,113 characters

Text of 1-CDMHANNL CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 4,692 characters

Text of 1-CDMHANNL CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 6 pages, 2 without text · 5,822 characters

Text of 1-CDMHANNL CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 7 pages, 2 without text · 8,527 characters

Text of 1-CD00412 CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 6 pages, 2 without text · 10,704 characters

Text of 1-CD00412 CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 16,197 characters

Text of 1-CD00412 CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 10 pages, 4 without text · 13,515 characters

Text of 1-CD00412 CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 8 pages, 4 without text · 11,076 characters

Text of 1-CD00412 (CDNXANNL) CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 6,643 characters

Text of 1-CD00258 CS & Closing Report 2018.pdf

Extracted from the file · 3 pages · 1,786 characters

Text of 1-495802 CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 331 pages, 76 without text · 481,532 characters

Text of 1-495802 CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 204 pages, 21 without text · 414,147 characters

Text of 1-495802 CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 163 pages, 25 without text · 244,382 characters

Text of 1-495802 CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 207 pages, 39 without text · 291,857 characters

Text of 1-201435 CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 2,904 characters

Text of 1-201435 CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 1,868 characters

Text of 1-201435 CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 2,526 characters

Text of 1-103353 CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 4,460 characters

Text of 1-103353 CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 3,734 characters

Text of 1-103353 CS & Closing Report 2018_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 2,489 characters

Text of 1-102118 CS & Closing Report 2021_Redacted.pdf

Extracted from the file · 14 pages, 5 without text · 19,415 characters

Text of 1-102118 CS & Closing Report 2020_Redacted.pdf

Extracted from the file · 11 pages, 2 without text · 21,744 characters

Text of 1-102118 CS & Closing Report 2019_Redacted.pdf

Extracted from the file · 11 pages, 3 without text · 16,618 characters

Text of 1-102118 CS & Closing Report 2017_Redacted.pdf

Extracted from the file · 9 pages, 3 without text · 14,796 characters

Text of 1-19733 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 944 characters

Text of 1-18742 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 2,245 characters

Text of 1-18CGVE11 CS & Closing Report.pdf

Extracted from the file · 3 pages · 1,756 characters

Text of 2-103353 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 3-DSEQ 2018 Variance Letter Docket.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-DB_CABLE 2019 Variance Letter.pdf

Extracted from the file · 4 pages · 10,910 characters

Text of 3-DB_CABLE 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-CTTRN19 Supplement_Redacted.pdf

Extracted from the file · 2 pages · 3,066 characters

Text of 3-CTTRN18 Supplemental_Redacted.pdf

Extracted from the file · 2 pages, 1 without text · 2,135 characters

Text of 3-CTMTR19 Supplemental_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,186 characters

Text of 3-CSTMER 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-CSTMER 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-CSTMER (CDCDANNL) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-495802 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-201435 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-102118 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 3- 103353 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-VLT_CORR 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-VLT_CORR 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-VLT_CORR 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-VLT_CORR (CDDKANNL) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-VLT_CORR (CDDKANNL) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-T1DWANA 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-LVEHPUR PAF 2019_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,122 characters

Text of 2-LVEHPUR PAF 2018_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 4,579 characters

Text of 2-LVEHPUR PAF 2017_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 5,072 characters

Text of 2-LVEHPUR 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-LN_RLBLTY 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-LN_RLBLTY 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-LN_RLBLTY 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-LN_RLBLTY (CDDRANNL) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-LN_RLBLTY (CDDRANNL) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-LN_RELO 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-LN_RELO 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-LN_RELO 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-LN_RELO (CDDHANNL) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-LN_RELO (CDDHANNL) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-LIGHTNG 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-LIGHTNG 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-LIGHTNG 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-LIGHTNG (D7DA24) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-LIGHTNG (D7DA24) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-IT1DWANA 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-IT1DWANA 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-INSCLMCST 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-INSCLMCST 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-INSCLMCST 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-INSCLMCST (CTINS24) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-INSCLMCST (CTINS24) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-GXTD20 PAF_Redacted.pdf

Extracted from the file · 2 pages · 1,991 characters

Text of 2-GXTD19 PAF_Redacted.pdf

Extracted from the file · 2 pages · 1,980 characters

Text of 2-GXENG PAF_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 2,867 characters

Text of 2-GXCOTRBL 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-GXCOTRBL 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-GXCOTRBL 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-GECNCLP PAF 2021_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 7,548 characters

Text of 2-ETTCF21 PAF_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 5,350 characters

Text of 2-ETTCF20 PAF_Redacted.pdf

Extracted from the file · 4 pages, 1 without text · 5,310 characters

Text of 2-ETTCF19 PAF_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,187 characters

Text of 2-ETTCF18 PAF_Redacted.pdf

Extracted from the file · 6 pages, 1 without text · 10,601 characters

Text of 2-ETTCF17 PAF_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 11,710 characters

Text of 2-ETT2017 PAF_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 11,710 characters

Text of 2-ETT2016 PAF_Redacted.pdf

Extracted from the file · 4 pages · 8,282 characters

Text of 2-ETR2021 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 6,729 characters

Text of 2-ETR2020 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 7,746 characters

Text of 2-ETR2019 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 7,746 characters

Text of 2-ETR2018 PAF_Redacted.pdf

Extracted from the file · 6 pages, 1 without text · 10,601 characters

Text of 2-EMRGNTLN 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-EMRGNTLN 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-EMRGNTLN 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-EMRGNTLN (CDEMANNL) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-EMRGNTLN (CDEMANNL) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-EFO_TLS 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-EFO_TLS 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-DT7C 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-DT7C 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-DT7C 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-DT7C 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-DT7C 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-DSEQ20 PAF_Redacted.pdf

Extracted from the file · 1 page · 2,381 characters

Text of 2-DSEQ 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-DSEQ 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,281 characters

Text of 2-DSEQ 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-DSEQ 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-DSEQ 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-DSCN21 PAF_Redacted.pdf

Extracted from the file · 1 page · 2,197 characters

Text of 2-DSCN20 PAF_Redacted.pdf

Extracted from the file · 1 page · 2,143 characters

Text of 2-DSCN 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-DSCN 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-DSCN 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-DB_CABLE 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-DB_CABLE 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-DB_CABLE 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-DB_CABLE (101395) Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-DB_CABLE (101395) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-CTTRN21 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,329 characters

Text of 2-CTTRN20 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 783 characters

Text of 2-CTTRN19 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,353 characters

Text of 2-CTTRN18 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,349 characters

Text of 2-CTROW17 PAF_Redacted.pdf

Extracted from the file · 9 pages, 2 without text · 11,710 characters

Text of 2-CTRMTR17 PAF_Redacted.pdf

Extracted from the file · 10 pages, 2 without text · 10,234 characters

Text of 2-CTMTR21 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,669 characters

Text of 2-CTMTR20 PAF_Redacted.pdf

Extracted from the file · 3 pages · 5,573 characters

Text of 2-CTMTR19 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,670 characters

Text of 2-CTMTR18 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,704 characters

Text of 2-CTMTR17 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,597 characters

Text of 2-CTFT2021 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 2,751 characters

Text of 2-CTFT2020 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 2,661 characters

Text of 2-CTEDVH21 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 7,548 characters

Text of 2-CTEDVH20 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 6,052 characters

Text of 2-CSTMER 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-CSTMER 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-CSTMER 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-CSTMER 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-CSTMER (CDCDANNL) 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-CSTMER (CDCDANNL) 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-CDMHANNL 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-CDMHANNL 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-CDMHANNL 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-CDMHANNL 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-CD00412 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-CD00412 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-CD00412 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-CD00412 (CDNXANNL) Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-495802 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 2-495802 2020 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,280 characters

Text of 2-495802 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-495802 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-201435 2019 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,054 characters

Text of 2-201435 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 2-201435 2017 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,042 characters

Text of 2-103353 2021 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 1,888 characters

Text of 3-DT7C 2020 Variance Letter_Redacted.pdf

Extracted from the file · 4 pages · 12,652 characters

Text of 401051 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

Text of 4-LVEHPUR 2019 Variance Letter.pdf

Extracted from the file · 4 pages · 10,910 characters

Text of 3-VLT_CORR 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-T1DWANA 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-LN_RLBLTY 2019 Variance Letter.pdf

Extracted from the file · 4 pages · 10,910 characters

Text of 3-LN_RLBLTY 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-LN_RLBLTY (CDDRANNL) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-LN_RELO (CDDHANNL) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-LIGHTNG (D7DA24) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-INSCLMCST 2019 Variance Letter.pdf

Extracted from the file · 4 pages · 10,910 characters

Text of 3-INSCLMCST 2018 Variance Letter.pdf

Extracted from the file · 3 pages · 7,767 characters

Text of 3-INSCLMCST (CTINS24) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 3-GXTD20 Supplemental_Redacted.pdf

Extracted from the file · 7 pages, 5 without text · 1,994 characters

Text of 3-ETT2016 Supplemental_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 2,208 characters

Text of 3-EMRGNTLN 2019 Variance Letter.pdf

Extracted from the file · 4 pages · 10,910 characters

Text of 3-EMRGNTLN (CDEMANNL) 2020 Variance Letter.pdf

Extracted from the file · 4 pages · 13,641 characters

Text of 468601 2018 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,098 characters

As listed on the current system

Supplement for New App [Filed: 09/25/2026]

This filing on the current system (opens in a new tab)