Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Application supplement

Exhibit CLP-Additions-6 Folder 4

Files396

Search terms highlighted
Eversource rate increase is on 16 pages across 16 files of the text below, highlighted. Go to the first matchClear highlighting

Text of 2-CDMHANNL24 - PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,315 characters

Words on different pages
Words on different pages
Words on different pages

Text of 2-CD00412 (CDNXANNL) PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,505 characters

Text of 2-CD00412 (CDNXANNL) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-CD00412 (CDNXANNL) - PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,383 characters

Text of 2-495802 PAF 2025_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 776 characters

Text of 2-495802 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-468601 (CD48KVAN24) PAF_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 1,795 characters

Text of 2-103353 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-102118 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-1DWANA2022 PAF_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 2,021 characters

Text of 2-1DWANA23 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 1-VLT_CORR CDDKANNL CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 29 pages, 6 without text · 45,650 characters

Text of 1-VLT_CORR (CDDKANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 19 pages, 2 without text · 32,216 characters

Text of 1-VLT_CORR (CDDKANNL) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 15 pages, 3 without text · 28,085 characters

Text of 1-VLT_CORR (CDDKANNL) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 23 pages, 3 without text · 48,763 characters

Text of 1-VEGDOT23 CS & Closing Report.pdf

Extracted from the file · 7 pages · 6,922 characters

Text of 1-VEGDOT22 CS & Closing Report_Redacted.pdf

Extracted from the file · 7 pages, 2 without text · 5,725 characters

Text of 1-ROWLN CS & Closing Report 2023.pdf

Extracted from the file · 2 pages · 856 characters

Text of 1-ML2510 CS & Closing Report.pdf

Extracted from the file · 2 pages · 910 characters

Text of 1-ML2410 CS & Closing Report.pdf

Extracted from the file · 5 pages · 4,666 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 127 pages, 35 without text · 163,013 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 125 pages · 247,443 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 129 pages, 9 without text · 282,140 characters

Text of 1-LN_RLBLTY (CDDRANNL) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 128 pages · 307,453 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 73 pages, 19 without text · 97,603 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 60 pages, 10 without text · 88,690 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 62 pages, 4 without text · 137,139 characters

Text of 1-LN_RELO (CDDHANNL) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 69 pages · 168,395 characters

Text of 1-LIGHTNG (D7DA24) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 206 pages, 26 without text · 279,696 characters

Text of 1--LIGHTNG (D7DA24) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 276 pages, 26 without text · 358,245 characters

Text of 1-LIGHTNG (D7DA24) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 291 pages, 17 without text · 510,958 characters

Text of 1-LIGHTNG (D7DA24) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 253 pages, 6 without text · 519,247 characters

Text of 1-IT1DWANA CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 1,921 characters

Text of 1-INSCLMCST (CTINS24) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 695 pages · 1,281,210 characters

Text of 1-INSCLMCST (CTINS24) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 711 pages · 1,197,528 characters

Text of 1-INSCLMCST (CTINS24) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 719 pages · 1,217,638 characters

Text of 1-INSCLMCST (CTINS24) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 663 pages · 1,192,604 characters

Text of 1-GXTD25 CS & Closing Report_Redacted.pdf

Extracted from the file · 8 pages, 2 without text · 9,844 characters

Text of 1-GXTD24 CS & Closing Report_Redacted.pdf

Extracted from the file · 12 pages, 2 without text · 17,710 characters

Text of 1-GXTD23 CS & Closing Report_Redacted.pdf

Extracted from the file · 20 pages, 3 without text · 33,398 characters

Text of 1-GXTD22 CS & Closing Report_Redacted.pdf

Extracted from the file · 21 pages, 1 without text · 39,182 characters

Text of 1-GXTD11 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 1-GXCOTRBL CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 6,573 characters

Text of 1-GXCOTRBL CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 4,023 characters

Text of 1-GXCOTRBL CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,435 characters

Text of 1-GXCOTRBL CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,885 characters

Text of 1-ETTCF25 CS & Closing Report_Redacted.pdf

Extracted from the file · 11 pages, 2 without text · 10,918 characters

Text of 1-ETTCF24 CS & Closing Report_Redacted.pdf

Extracted from the file · 21 pages, 5 without text · 26,159 characters

Text of 1-ETTCF23 CS & Closing Report_Redacted.pdf

Extracted from the file · 29 pages, 3 without text · 41,767 characters

Text of 1-ETTCF22 CS & Closing Report_Redacted.pdf

Extracted from the file · 19 pages, 5 without text · 20,951 characters

Text of 1-ETR2025 CS & Closing Report_Redacted.pdf

Extracted from the file · 156 pages, 2 without text · 169,053 characters

Text of 1-ETR2024 CS & Closing Report_Redacted.pdf

Extracted from the file · 143 pages, 3 without text · 153,384 characters

Text of 1-ETR2023 CS & Closing Report_Redacted.pdf

Extracted from the file · 165 pages, 2 without text · 174,443 characters

Text of 1-ETR2022 CS & Closing Report_Redacted.pdf

Extracted from the file · 264 pages, 19 without text · 251,344 characters

Text of 1-EMRGNTLN (CDEMANNL) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 1,370 pages · 2,550,421 characters

Text of 1-EMRGNTLN (CDEMANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 1,264 pages · 2,244,173 characters

Text of 1-EMRGNTLN (CDEMANNL) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 1,510 pages · 2,708,317 characters

Words on different pages
  1. Page 875 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80282435 Total 80282442 80282442 Total 80282486 80282486 Total 80282516 Description Values Sum of Quantity CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E CONNECTOR,ELBOW, LOADBREAK, 15 KV, 200 A, #1 AWG STRANDED, 175 KCMIL, 0.705-0.765 IN CABLE DIA, AL ARRESTER,SURGE, ELBOW, LOADBREAK, 13.2 KV AND 13.8 KV MGY SYSTEM VOLTAGE, 12 KV ARRESTER RATING, 10. BUSS BAR, EXTENSION, 2400A, 600 V, 24 IN LG, 4 IN W, 1/2 IN THK, TINNED, CU 0 0 ARRESTER,SURGE, ELBOW, LOADBREAK, 13.2 KV AND 13.8 KV MGY SYSTEM VOLTAGE, 12 KV ARRESTER RATING, 10. TERMINAL, 4 HOLE NEMA PAD, 2 TO 750 KCMIL, PAD TO MULTIPLE CABLES, AL OR CU, FOR 6 CABLES FOR 3 PHAS 80282516 Total 80282563 0 POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, FIBERGLASS, 30 EA/PALLET CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80282563 Total 80283513 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80283513 Total 80283521 BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE CONNECTOR,ELBOW, LOADBREAK, 15 KV, 200 A, #1 AWG STRANDED, 175 KCMIL, 0.705-0.765 IN CABLE DIA, AL TERMINATOR,CABLE, #2-4/0, 0.637 - 1.12 IN CABLE DIA, 15 KV, W/O PIN TAP OR LUG, AL/CU, FOR INDOOR/OU ARRESTER,SURGE, ELBOW, LOADBREAK, 13.2 KV AND 13.8 KV MGY SYSTEM VOLTAGE, 12 KV ARRESTER RATING, 10. CABLE, INSULATED, UG, 1/C, #1 AWG, 15 KV, EPR INSULATED, LLDPE JACKET, AL BEND,CONDUIT, 4 IN , 36 IN RADIUS, PVC, SCH 40, ONE BELLED END, GRAY, 90 DEG 80283521 Total 80283547 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80283547 Total 80283550 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80283550 Total 80283558 0 CABLE, FLAT STRAP, TRIPLEX, 500 KCMIL, 15 KV, EPR INSULATED, CU, 1200 FT Steel Reel/Lot SPLICE,ELECTRICAL, TRANSITIONAL/HEAT SHRINK, 4/0 TO 350 STR, STRAIGHT, 15 KV, INSULATED, FOR 3/C PLI CONNECTOR,COMPRESSION, SLEEVE, 250 TO 250 KR, KS OR STR, 3-1/2 IN LG, 35 KV, TINNED CU, HOT TIN DIPP 80283558 Total 80283575 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DEADEND, 4 5/8¿¿ X 3 5/8¿¿, 10 LONG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 30 ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB ANCHOR, SINGLE HELIX, SOCKET DRIVE, 14 IN, 8000 LB 80283575 Total 80283605 80283605 Total 80283610 80283610 Total 80283618 80283618 Total 80283650 80283650 Total 80283685 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER LUMINAIRE, LED, POST TOP, 120 V, 36W NOMINAL, CONTEMPORARY, Gray Finish POLE, STREETLIGHT, 18 FT LG, ROUND, FIBERGLASS, GRAY, FOR POST TOP LUM ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS Sum of Amount $225.11 $124.98 $124.98 $0.00 $204.92 $0.00 $204.92 $222.79 $232.41 $455.20 $78.36 $380.51 $231.46 $93.23 $783.56 $13.34 $120.05 $133.39 $14.58 $21.01 $48.66 $61.85 $395.96 $23.12 $565.18 $6.56 $59.10 $65.66 $30.97 $62.84 $93.81 $1,021.57 $6,809.90 $2,292.54 $91.77 $10,215.78 $71.62 $35.62 $61.40 $183.65 $380.82 $202.30 $38.68 $68.07 $1,042.16 $27.31 $61.51 $88.82 $192.61 $192.61 $394.74 $173.14 $567.88 $38.71 $342.74 $381.45 $63.82
  2. Page 876 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80283685 80283685 Total 80283695 Description CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER Values Sum of Quantity 0 CONNECTOR,ELBOW, LOADBREAK, 25 KV, 200 A, #1 AWG STRANDED, 260 KCMIL, 0.83-1.1 IN CABLE DIA, AL PAD, 48 IN LG, 42 IN W, 4 IN H, PRECAST CONCRETE, 547 LB, 167 KVA MAX 80283695 Total 80283697 80283697 Total 80283753 80283753 Total 80283782 80283782 Total 80283808 80283808 Total 80283809 80283809 Total 80283904 80283904 Total 80283951 ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P SWITCH,DISTRIBUTION, 900 A, 40 KA MOM, 60 KA MOM PEAK, 25 KV, MANUAL, SIDE BREAK, 150 KV BIL , 3 PH, CABLE, COVERED, SPACER, 1/C, 556.5 KCMIL, 19 STR, 25/30 KV, POLY, AL CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E CROSSARM, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, FIBERGLASS, 30 EA/PALLET CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CABLE, COVERED, 1/C, 336.4 KCMIL, 19 STR, 175 MILS POLY, AL 0 PLUG,CONNECTING, DEADBREAK, 15/25 KV, 600 A PLUG,DEADEND, 15 OR 25 KV, 600 A, W/ TEST POINT & SHIELDING CAP 80283951 Total 80283978 80283978 Total 80284302 80284302 Total 80284303 SPLICE,ELECTRICAL, COLD SHRINK, MIN INSULATION DIA 1.36 IN, MAX JACKET DIA 2.44 IN, STRAIGHT, 15/25/ CONNECTOR,COMPRESSION, SLEEVE, 1000 TO 700 COMPACT ROUND KR, KS/STR, 6 IN LG, 35 KV, TINNED CU, HOT CONNECTOR,COMPRESSION, SLEEVE, 1000 TO 750,KR, KS OR STR, 6 IN LG, 35 KV, TINNED CU, HOT TIN DIPPED, CONNECTOR,COMPRESSION, SLEEVE, 1000,KR, KS OR STR, 6 IN LG, 35 KV, TINNED CU, HOT TIN DIPPED, TAPERE TERMINATOR,CABLE, 1000, 750, 1.31-2.1 IN CABLE DIA, 25/30/35 KV, W/O PIN TAP OR LUG, FOR INDOOR/OUTD CABLE, INSULATED, UG, 1000 KCMIL, 30 KV, EPR INSULATED, PP JACKET, CU ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 80284303 Total 80284331 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80284331 Total 80284349 80284349 Total 80284351 80284351 Total 80284361 80284361 Total 80284397 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80284397 Total 80284434 RECLOSER, OIL, TYPE: 4E, 24.9 KV, 280 A CONTINUOUS, COIL: 140 A TRIP, 4 KA, 1 PH, HYDRAULIC, DELAYE Sum of Amount $136.44 $200.26 $22.76 $109.96 $94.76 $227.48 $416.56 $3,097.85 $3,514.41 $70.51 $70.51 $134.44 $481.37 $832.27 $126.20 $263.83 $195.62 $2,033.73 $444.33 $36.08 $480.41 $67.33 $67.33 $11.83 $11.83 $48.70 $249.95 $188.19 $486.84 $5,682.34 $112.87 $135.94 $199.09 $1,371.68 $33,976.81 $41,478.73 $34.24 $34.24 $58.45 $59.19 $117.58 $349.29 $584.51 $9.81 $29.21 $59.09 $98.11 $146.24 $146.24 $336.02 $336.02 $114.76 $114.76 $6.54 $58.78 $65.32 $3,928.08
  3. Page 877 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80284434 Total 80284460 80284460 Total 80284461 Description Values Sum of Quantity CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E CUTOUT, SOLID BLADE, OPEN, LOADBUSTER, 300 A, 12 KA MOMENTARY, 25 KV, 150 KV BIL, W/O BRACKET CROSSARM, DEADEND, 4 5/8¿¿ X 3 5/8¿¿, 10 LONG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 30 ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB ANCHOR, SINGLE HELIX, SOCKET DRIVE, 14 IN, 8000 LB 80284461 Total 80284479 80284479 Total 80284494 CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 48 EA/PALLET HANDHOLE, 36 IN DIA, 36 IN H, PRECAST CONCRETE PAD, 48 IN LG, 42 IN W, 4 IN H, PRECAST CONCRETE, 547 LB, 167 KVA MAX 80284494 Total 80284696 80284696 Total 80284698 0 0 0 0 POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 80284698 Total 80284704 80284704 Total 80285153 80285153 Total 80285154 ENCLOSURE,ELECTRICAL, 36 X 36 X 19 IN, PAD MOUNTED, MUNSELL GREEN, FIBERGLASS , W/ BOTTOM OPENING 28 ENCLOSURE, PROTECTIVE, 15/25 KV, FIBERGLASS SHELL, FOR REPAIRS, SWITCH (DOGHOUSE)-CAT IDS 0183419 & ENCLOSURE, 15 IN X 10 IN TOP X 12 IN H, GREEN, NON-METALLIC, SMALL, FOR LIGHTING ONLY, URD SERVICE 0 0 0 0 ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER 80285154 Total 80285158 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 1, SOUTHREN YELLOW PINE, CCA TREATED 80285158 Total 80285208 80285208 Total 80285248 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER TERMINATOR,CABLE, #1-350, #2, #2-1/0, 0.840 - 1.38 IN CABLE DIA, 25/35 KV, W/O PIN TAP OR LUG, AL/CU WIRE,ELECTRICAL, SPACER/LINE, COMPACT, 1/0 AWG ACSR, 75 C, TWO LAYERS INSULATED, 175 MIL POLY JACKET CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 48 EA/PALLET CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E 80285248 Total 80285258 80285258 Total 80285354 ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80285354 Total 80285524 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80285524 Total 80285540 FUSEHOLDER, POWER, END FITTINGS , W/ SILENCER, FOR USE W/ 14.4 KV OR 25 KV SMU-20 FUSE UNIT, TYPE SM SWITCHGEAR,DISTRIBUTION, 12.5/20 KA SYM, 20/32 KA ASYM, 15/25 KV, 1-150CL OR 1-200E FUSE, 1-600 A SW FUSE,POWER, 140 A, K, 14.4 KV, 22400 A ASYM, S&C, COOPER TYPE CMUSMU-20 FUSE,POWER, X LIMITER CLIP STYLE, CURRENT LIMITING, 150 A, 15 KV, MOUNTING CODE 21 IN FUSEHOLDER, POWER, CURRENT LIMITING, 150 A, 32 KA ASYMMETRICAL, 15 KV , 95 KV BIL Sum of Amount $3,928.08 $124.25 $124.25 $121.72 -$173.35 $453.13 $138.65 $114.09 $270.44 $195.15 $34.38 $62.94 $1,217.15 $143.09 $143.09 $0.00 $0.00 $0.00 $275.12 $275.12 $49.10 $441.83 $490.93 $642.46 $252.55 $895.01 -$4.04 -$4.04 $7.46 $132.18 $139.64 $43.82 $82.32 $531.67 $657.81 $229.52 $229.52 $114.74 $231.14 $123.20 $206.27 $129.54 $342.28 $1,147.17 $59.52 $59.52 $37.42 $77.55 $114.97 -$10.66 $122.80 $112.14 $1,208.24 $12,183.91 $416.50 $1,129.84 $2,986.48
  4. Page 878 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80285540 Total 80285857 Description Values Sum of Quantity 0 POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED SWITCH,DISCONNECT, 600 A, 65 KA MOM PEAK, 25 KV, 125 KV BIL , 1 PH, AIR, VERTICAL MOUNT, INSULATED, 80285857 Total 80285884 0 SPLICE,ELECTRICAL, TRANSITIONAL, HEAT SHRINK, 350 TO 750 KCMIL, STRAIGHT, 25 KV, INSULATED, FOR CONN CABLE, INSULATED, UG, 3-1/C, 350 KCMIL, 25 KV, EPR INSULATED, LLDPE JACKET, CU, P/O 177728 80285884 Total 80285899 80285899 Total 80285918 80285918 Total 80285951 MOUNT,CLUSTER, TRANSFORMER, MEDIUM, 5/8 X 2-1/2 IN, 37.5-167 KVA, AL, W/ SIX - SQ.HD. BOLTS, HEX NUT CABLE, INSULATED, AERIAL, 3CT, 500 KCMIL, 37 STR, 15 KV, W/ 19-#9 AWG CPW MESSENGER, EPR INSULATED, 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CONTAINMENT,OIL, 25 D x 56 IN H, 10 MIL THK, POLYETHYLENE, W/ VELCRO CLOSURE, FOR TRANSFORMER, 5 PER SPILL CONTAINMENT KIT, INCIDENTAL, OIL, 4 EA/CTN, CONSISTS OF: (25) OIL PADS, (3) MINI-BOOMS 3 IN X 80285951 Total 80285990 80285990 Total 80285995 ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CONTAINMENT,OIL, 25 D x 56 IN H, 10 MIL THK, POLYETHYLENE, W/ VELCRO CLOSURE, FOR TRANSFORMER, 5 PER 80285995 Total 80286004 0 CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80286004 Total 80286008 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80286008 Total 80286018 80286018 Total 80286030 80286030 Total 80286045 80286045 Total 80286104 80286104 Total 80286224 80286224 Total 80286247 80286247 Total 80286260 80286260 Total 80286315 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DEADEND, 4 5/8¿¿ X 3 5/8¿¿, 10 LONG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 30 ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P BRACKET,LUMINAIRE, SINGLE GUY, 1-1/4 IN X 6 FT, STEEL, GALV, ANSI C136.13 CLASS D RATING, W/ GROUND Sum of Amount $17,924.97 $90.83 $417.84 $399.68 $908.35 -$306.27 $2,883.07 $326.86 $2,903.66 $192.27 $192.27 $2,256.85 $2,256.85 $0.00 $204.66 $55.21 $32.88 $292.75 $34.88 $34.88 $15.32 $27.31 $61.51 $48.97 $153.11 $10.46 $94.11 $104.57 $19.58 $59.20 $117.17 $195.95 $326.34 $326.34 $134.82 $134.82 $35.09 $64.20 $99.29 $38.18 $336.07 $374.25 $35.69 $66.69 $102.38 $42.57 $65.09 $399.54 $507.20 $646.76 $646.76 $204.12 $474.49 $481.88 $36.08 $159.66 $70.18
  5. Page 879 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80286315 Total 80286321 80286321 Total 80286608 Description Values Sum of Quantity ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P 80286608 Total 80286638 80286638 Total 80286653 POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 0 CABLE, INSULATED, UG, 3-1/C, 350 KCMIL, 25 KV, EPR INSULATED, LLDPE JACKET, CU, P/O 177728 80286653 Total 80286656 80286656 Total 80286667 BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE CONNECTOR,ELBOW, LOADBREAK, 15 KV, 200 A, #1 AWG STRANDED, 175 KCMIL, 0.705-0.765 IN CABLE DIA, AL CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER TERMINATOR,CABLE, #2-4/0, 0.637 - 1.12 IN CABLE DIA, 15 KV, W/O PIN TAP OR LUG, AL/CU, FOR INDOOR/OU ARRESTER,SURGE, ELBOW, LOADBREAK, 13.2 KV AND 13.8 KV MGY SYSTEM VOLTAGE, 12 KV ARRESTER RATING, 10. BRACKET, 48 X 13 X 1-1/2 IN, FIBERGLASS, HOT DIPPED GALVANIZED END W/ HARDWARE, FOR EQUIPMENT, RISE CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 48 EA/PALLET ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P CABLE, INSULATED, UG, 3-1/C, #1 AWG, 15 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177698 BOX, HANDHOLE, 30 IN LG, 17 IN W, 18 IN DP, POLYMER CONCRETE, W/ HEAVY DUTY COVER AND ELECTRIC LOG LUMINAIRE, LED, POST TOP, 120 V, 28W NOMINAL, TRADITIONAL, BLACK FINISH POLE, STREETLIGHT, 18 FT LG, FIBERGLASS, BROWN, FOR POST TOP LUM 80286667 Total 80286687 0 CABLE, INSULATED, UG, 750 KCMIL, 25 KV, EPR INSULATED, LLDPE JACKET, CU, P/O 177732, 3-1/C TRIPLEX CONNECTOR,COMPRESSION, SLEEVE, 750,KR, KS OR STR, 5 IN LG, 35 KV, TINNED CU, HOT TIN DIPPED, TAPERED SPLICE,ELECTRICAL, TRANSITIONAL, 750 PILC TO 750 TO 1000 SOLID DIELECTRIC, 1/C, 25 KV, INSULATED, HK 80286687 Total 80286689 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80286689 Total 80286696 0 CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 48 EA/PALLET 80286696 Total 80286713 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80286713 Total 80286735 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80286735 Total 80286899 POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E SPACER,CABLE, 46 KV, W/ CONDUCTOR CLAMPS, POLYETHYLENE, MFR: HENDRIX BRACKET,TANGENT, SPACER, 24 IN, DI, HOT DIP GALV, USE: MESSENGER BRACKET FOR 25KV SPACER, BM24 80286899 Total 80286902 0 0 0 CAPACITOR,DISTRIBUTION, CAN, 13280 V, 200 KVAR, 95 KV BIL, 1-PH, 17 IN CREEP, 2-BUSHING, SPC-151-152 80286902 Total 80286936 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER Sum of Amount $1,426.41 $190.89 $190.89 -$0.01 $153.64 $43.39 $197.02 $345.20 $345.20 $1,700.89 $15,308.02 $17,008.91 $47.02 $70.88 $194.44 $161.91 $207.56 $113.68 $143.47 $157.77 $1,094.34 $2,191.07 $344.89 $412.36 $298.26 $1,055.51 $135.71 $582.83 $62.36 $576.09 $1,356.99 $67.33 $101.68 $169.01 $14.31 $128.78 $143.09 $6.66 $60.03 $66.69 $19.97 $32.13 $60.02 $87.59 $199.71 $55.43 $0.00 $113.61 $282.87 $102.36 $554.27 -$436.05 $436.05 $0.00 $9.92 $30.34 $58.86
  6. Page 880 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80286936 Total 80287812 Description Values Sum of Quantity CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CONTAINMENT,OIL, 25 D x 56 IN H, 10 MIL THK, POLYETHYLENE, W/ VELCRO CLOSURE, FOR TRANSFORMER, 5 PER 80287812 Total 80287814 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, FIBERGLASS, 30 EA/PALLET 80287814 Total 80287830 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80287830 Total 80287831 80287831 Total 80287840 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 0 ENCLOSURE, 15 IN X 10 IN TOP X 12 IN H, GREEN, NON-METALLIC, SMALL, FOR LIGHTING ONLY, URD SERVICE 80287840 Total 80287881 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80287881 Total 80287889 80287889 Total 80287892 80287892 Total 80287894 0 ENCLOSURE, 15 IN X 10 IN TOP X 12 IN H, GREEN, NON-METALLIC, SMALL, FOR LIGHTING ONLY, URD SERVICE FOAM, FROTH-PAK, 1 CU FT YIELD, 2-COMPONENT POLYURETHANE, SELF-CONTAINED KIT, PORTABLE, DISPENSING S 80287894 Total 80287897 80287897 Total 80287919 LUMINAIRE, LED, POST TOP, 120 V, 28W NOMINAL, TRADITIONAL, BLACK FINISH POLE, STREETLIGHT, 18 FT LG, FIBERGLASS, BROWN, FOR POST TOP LUM 80287919 Total 80287924 80287924 Total 80287948 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CAP,ELECTRICAL, INSULATING, DEADEND, LOADBREAK, 25 KV, 200 A MOUNT,CLUSTER, TRANSFORMER, MEDIUM, 5/8 X 2-1/2 IN, 37.5-167 KVA, AL, W/ SIX - SQ.HD. BOLTS, HEX NUT CONTAINMENT,OIL, 25 D x 56 IN H, 10 MIL THK, POLYETHYLENE, W/ VELCRO CLOSURE, FOR TRANSFORMER, 5 PER 80287948 Total 80287950 80287950 Total 80287967 80287967 Total 80287991 CABLE, INSULATED, UG, 3-1/C, 4/0 AWG, 25 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177696 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80287991 Total 80287992 80287992 Total 80287996 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80287996 Total 80288027 80288027 Total POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED Sum of Amount $99.12 $130.79 $109.64 $240.43 $42.10 $29.21 $118.18 $231.46 $420.95 $12.84 $115.57 $128.41 $133.39 $133.39 $11.64 $104.70 $116.34 $9.87 $27.31 $61.52 $98.70 $231.04 $231.04 $207.48 $207.48 $151.45 $61.94 $117.75 $331.14 $138.32 $138.32 $412.36 $298.26 $710.62 $30.26 $30.26 $0.00 $194.49 $180.01 $225.86 $54.82 $655.18 $807.64 $807.64 $229.52 $229.52 $6.42 $57.78 $64.20 $229.52 $229.52 $9.87 $27.32 $61.51 $98.70 $375.61 $375.61
  7. Page 881 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80288044 Description Values Sum of Quantity 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80288044 Total 80288055 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80288055 Total 80288056 0 POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 80288056 Total 80288062 80288062 Total 80288162 80288162 Total 80288223 80288223 Total 80288312 80288312 Total 80288320 80288320 Total 80288331 80288331 Total 80288545 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR BOX, HANDHOLE, 30 IN LG, 17 IN W, 18 IN DP, POLYMER CONCRETE, W/ HEAVY DUTY COVER AND ELECTRIC LOG CABLE, INSULATED, #4 AWG, 600 V, BLACK W/ YELLOW STRIPES, XLPE INSULATED, AL, FOR STREET LIGHT, DELG 0 PAD, 48 IN LG, 42 IN W, 4 IN H, PRECAST CONCRETE, 547 LB, 167 KVA MAX 80288545 Total 80288574 80288574 Total 80288577 80288577 Total 80288594 80288594 Total 80288616 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80288616 Total 80288702 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80288702 Total 80288863 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80288863 Total 80289038 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, DEADEND, 3-5/8 X 4-5/8 IN, 8 FT LG, FIBERGLASS, 30 EA/PALLET CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80289038 Total 80289049 80289049 Total 80289051 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80289051 Total 80289064 80289064 Total 80289217 ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER Sum of Amount $13.34 $120.05 $133.39 $13.34 $120.05 $133.39 $38.52 $346.60 $385.12 $68.04 $68.04 $113.41 $91.49 $204.90 $1,018.67 $1,018.67 $87.73 $87.73 $229.52 $229.52 $367.08 $367.08 $10.54 $94.76 $105.30 $68.22 $124.98 $193.20 $408.40 $38.95 $447.35 $162.00 $162.00 $131.73 $104.57 $236.30 $9.87 $27.31 $61.52 $98.70 $37.26 $84.07 $121.33 $113.91 $353.14 $478.93 $193.09 $1,139.07 $65.40 $65.40 $13.08 $117.71 $130.79 $46.62 $46.62 $35.69 $66.69
  8. Page 882 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80289217 80289217 Total 80289223 80289223 Total 80289268 Description POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED Values Sum of Quantity SHIELD, POLE RISER, 2 IN, 10 FT LG, HMP, FOR CAPACITY AND RECLOSERS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER RECLOSER, OIL, 24.9 KV, COIL: 200 A TRIP, 280 A CONTINUOUS, 4 KA, 1 PH, HYDRAULIC, DELAYED CURVE B, 80289268 Total 80289336 0 CONTAINMENT,OIL, 72 IN H, 10 MIL THK, 36 IN DP, POLYETHYLENE, W/ ADJUSTABLE DRAW STRINGS, OIL PAD AT CABLE, INSULATED, UG, 4/C, 500 KCMIL, 600 V, W/ 4/0 AWG NEUTRAL, EPR INSULATED, CU TAPE,INSULATION, JACKETING, 30 FT LG X 1 IN W, SILICONE RUBBER, GRAY MUNSELL 80289336 Total 80289365 80289365 Total 80289401 80289401 Total 80289680 80289680 Total 80289695 80289695 Total 80289696 80289696 Total 80289735 CONNECTOR,ELBOW, LOADBREAK, 25 KV, 200 A, #1 AWG STRANDED, 260 KCMIL, 0.83-1.1 IN CABLE DIA, AL CABLE, INSULATED, UG, 1/C, #1 AWG, 25 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177700 PAD, 48 IN LG, 42 IN W, 4 IN H, PRECAST CONCRETE, 547 LB, 167 KVA MAX INDICATOR,FAULT, UNDERGROUND, 200 A MIN TRIP, 8 HR, SELF ADJUSTING TRIP CURRENT RANGE, 0.85-1.57 IN POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, ELBOW, LOADBREAK, 13.2 KV AND 13.8 KV MGY SYSTEM VOLTAGE, 12 KV ARRESTER RATING, 10. TUBING, HEAT SHRINK, HEAVY WALL, FLAME RETARDANT, 1000 V, 0.70 IN ID, 1.75 IN OD, 48 IN LG, 250-500 CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR ANCHOR, SINGLE HELIX, SOCKET DRIVE, 14 IN, 8000 LB 0 RADIO, SIERRA WIRELESS, MOBILE AIRLINK RV55 MODEM CONTROL,RECLOSER, CLOSING COIL, LOW VOLTAGE, ELECTRONICALLY, LOOP SCHEME, W/ SCADA READY, TYPE: FORM TRANSCOR HAYWOOD ASSOC INC RECLOSER, VACUUM, SOLID DIELECTRIC, 13.8/13.2 KV, 800 A CONTINUOUS, 12.5 KA, 3 PH, W/SS JUNC BOX, LO BASE,MOUNTING, ANTENNA, Laird Technologies - 4G/3G Multiband Phantom Antenna Black NMO CABLE ASSEMBLY, COMMUNICATION, Serial DB9 Serial Ext Cable, (DB9 M/F), 6-ft SWITCH,DISCONNECT, IN LINE, 900 A CONTINUOUS, 35 KV, 200 KV BIL, 4/0 ACSR, 0.492-.613 IN DIA, AIR, W 80289735 Total 80289750 80289750 Total 80289763 0 POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80289763 Total 80289932 0 ANCHOR,ROCK, 1 IN X 53 IN , LEDGE PIN 80289932 Total 80289944 80289944 Total 80289950 80289950 Total 80289958 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 0 POLE, 45 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 10 FT LG , W/ CENTER MOUNT BRACKET, FIBERGLASS, 48 EA/PALLET ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P SWITCH,DISTRIBUTION, 900 A, 40 KA MOM, 60 KA MOM PEAK, 25 KV, MANUAL, SIDE BREAK, 150 KV BIL , 3 PH, HOLDER,SIGN, MOLDED, 8 POSITIONS, VERTICAL, #2, 1-5/8 X 21-1/4 IN, AL, W/ 2-1/4 X 1/2 IN NUTS/BOLTS 80289958 Total 80290035 ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER CONTROL,CAPACITOR, VAR/VOLT ONLY, NEUTRAL CURRENT TRIP, 6-JAW SOCKET MOUNTED, FOR HD ELECTRIC 2000 S CONNECTOR,CABLE, WATERTIGHT, 1/2 IN HUB, 0.25-0.375 IN CABLE DIA, ROUND OPENING, W/ SEALING LOCKNUT Sum of Amount $400.73 $503.11 $23.76 $23.76 $196.98 $4,093.69 $4,290.67 $320.74 $64.25 $3,418.25 $73.67 $3,876.91 $40.58 $81.07 $108.75 $178.51 $408.91 $401.79 $401.79 $211.86 $47.50 $259.36 $95.18 $95.18 $61.26 $61.26 $3,305.42 $801.62 $9,235.38 $6.33 $20,596.65 $130.41 $3.77 $2,224.11 $36,303.69 $292.67 $292.67 $6.66 $60.03 $66.69 $4.92 $44.25 $49.17 $64.20 $64.20 $116.28 $116.28 $351.31 $455.61 $145.07 $272.06 $2,787.78 $8.93 $4,020.76 $287.25 $1,875.37 $8.84
  9. Page 883 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80290035 80290035 Total 80290370 80290370 Total 80290401 80290401 Total 80290403 80290403 Total 80290414 Description CONNECTOR,CABLE, WATERTIGHT, 3/4 IN HUB, 0.625-0.75 IN CABLE DIA, ROUND OPENING, W/ SEALING LOCKNUT GUARD,ANIMAL, PIEDMONT, SENSING INSULATORS, FOR CAP BANK INSTALLATIONS SENSOR,CURRENT, LINE POST, CLAMP TOP, 25 KV, COLOR: GRAY CAPACITOR,DISTRIBUTION, BANK ASSEMBLY, SWITCHED, 23 KV, 1800 KVAR, 125 KV BIL, 200 KVAR/CAN, 3-PH, P Values Sum of Quantity ANCHOR, EXPANDABLE, 12 IN, FOR 1 IN RODS POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, PENTA TREATED ENCLOSURE, 30 IN X 17 IN TOP, 18 IN H, GREEN, NON-METALLIC, LARGE, FOR UNDERGROUND SERVICE BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80290414 Total 80290432 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80290432 Total 80290450 80290450 Total 80290568 POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, ELBOW, LOADBREAK, 22.9 KV MGY SYSTEM VOLTAGE, 18 KV ARRESTER RATING, 15.3 KV MCOV CONNECTOR,ELBOW, LOADBREAK, 25 KV, 200 A, #1 AWG STRANDED, 260 KCMIL, 0.83-1.1 IN CABLE DIA, AL CABLE, INSULATED, UG, 1/C, #1 AWG, 25 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177700 BUSHING,ELECTRICAL, LOADBREAK CONNECTOR, 25 KV, 200 A INDICATOR,FAULT, UNDERGROUND, 200 A MIN TRIP, 8 HR, SELF ADJUSTING TRIP CURRENT RANGE, 0.85-1.57 IN 80290568 Total 80290652 0 0 BRACKET, ADAPTER, 4000 LB MAX LOAD, STEP TRANSFORMER, REGULATOR, FOR MOUNTING DIRECTLY TO POLE 80290652 Total 80290676 0 RADIO, SIERRA WIRELESS, MOBILE AIRLINK RV55 MODEM RECLOSER, VACUUM, SOLID DIELECTRIC, 22.9 KV, 800 A CONTINUOUS, 12.5 KA, 3 PH, W/ SS JUNCTION BOX, RA TRANSCOR HAYWOOD ASSOC INC BASE,MOUNTING, ANTENNA, Laird Technologies - 4G/3G Multiband Phantom Antenna Black NMO CABLE ASSEMBLY, COMMUNICATION, Serial DB9 Serial Ext Cable, (DB9 M/F), 6-ft 80290676 Total 80290688 0 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80290688 Total 80290743 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E 80290743 Total 80290992 80290992 Total 80291576 80291576 Total 80291613 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 0 BRACKET,CABLE, TERMINATOR MOUNTED, AL, FOR 0.75 THRU 3.00 IN DIA CABLE CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER ARRESTER,SURGE, DISTRIBUTION RISER POLE, METAL OXIDE VARISTOR (MOV), 18 KV, 15.3 KV MCOV, POLYMER CONNECTOR,ELBOW, LOADBREAK, 25 KV, 200 A, #1 AWG STRANDED, 260 KCMIL, 0.83-1.1 IN CABLE DIA, AL TERMINATOR,CABLE, #1-350, #2, #2-1/0, 0.840 - 1.38 IN CABLE DIA, 25/35 KV, W/O PIN TAP OR LUG, AL/CU BUSHING,ELECTRICAL, LOADBREAK CONNECTOR, 25 KV, 200 A 80291613 Total Sum of Amount $9.61 $70.37 $844.84 $10,447.17 $13,543.45 $51.45 $649.15 $700.60 $123.12 $123.12 $273.22 $273.22 $33.55 $63.74 $97.29 $19.46 $60.39 $114.73 $194.58 $395.88 $395.88 $0.00 $78.35 $306.02 $67.07 $179.85 $631.29 $5.60 $50.41 $56.01 $2,457.38 $801.84 $22,116.42 $6.33 $130.45 $3.77 $25,516.19 $12.97 $116.76 $129.73 $19.36 $60.07 $114.06 $193.49 $63.92 $124.38 $188.30 $63.93 $63.93 $101.52 $41.69 $175.14 $124.28 $109.47 $371.55 $91.44 $1,015.09
  10. Page 884 of 1,246

    funding project EMRGNTLN Cost Element Category Material month number (blank) accounting work order 80291619 80291619 Total 80291631 Description BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80291631 Total 80291658 Values Sum of Quantity 0 0 0 0 CONNECTOR,ELBOW, LOADBREAK, 25 KV, 200 A, #1 AWG STRANDED, 260 KCMIL, 0.83-1.1 IN CABLE DIA, AL CABLE, INSULATED, UG, 1/C, #1 AWG, 25 KV, EPR INSULATED, LLDPE JACKET, AL, P/O 177700 BUSHING,ELECTRICAL, LOADBREAK CONNECTOR, 25 KV, 200 A TUBING, HEAT SHRINK, HEAVY WALL, FLAME RETARDANT, 1000 V, 0.40 IN ID, 0.95 IN OD, 48 IN LG, BLACK CONTAINMENT,OIL, 72 IN H, 10 MIL THK, 36 IN DP, POLYETHYLENE, W/ ADJUSTABLE DRAW STRINGS, OIL PAD AT TUBING, HEAT SHRINK, HEAVY WALL, FLAME RETARDANT, 1000 V, 0.70 IN ID, 1.75 IN OD, 48 IN LG, 250-500 80291658 Total 80291669 80291669 Total 80291800 80291800 Total 80291877 80291877 Total 80292285 80292285 Total 80292290 ENCLOSURE, 30 IN X 17 IN TOP, 18 IN H, GREEN, NON-METALLIC, LARGE, FOR UNDERGROUND SERVICE CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR POLE, 35 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ANCHOR, SINGLE HELIX, SOCKET DRIVE, 10 IN, 8000 LB 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR 80292290 Total 80292299 80292299 Total 80292307 80292307 Total 80292313 80292313 Total 80292317 80292317 Total 80292318 CROSSARM, DISTRIBUTION, TANGENT, 3-5/8 X 4-5/8 IN, 5 FT-7 IN LG, W/ CENTER MOUNT BRACKET AND HARDWAR SWITCH,DISTRIBUTION, 600 A, 30 KA MOM , 25 KV, REGULATOR BY-PASS, MANUAL, 150 KV BIL , 1 PH, AIR, VE POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 0 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER 80292318 Total 80292371 80292371 Total 80292509 80292509 Total 80292689 80292689 Total 80293144 80293144 Total 80293177 BRACKET, CUTOUT AND ARRESTER, 12 IN, FIBERGLASS, FERR / ALUM FITTINGS W/ MOUNTING BOLTS CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER POLE, 40 FT LG, CLASS 2, SOUTHREN YELLOW PINE, CCA TREATED ARRESTER,SURGE, LIGHTNING, RISER/LINE, 12 KV, W/ 30I N #4 CU POLY-COVERED ISOLATOR, ANIMAL GUARD, P 0 CUTOUT, FUSE, OPEN, 100 A, 12 KA INTERRUPTING CURRENT ASYMMETRICAL, 25 KV, 150 KV BIL, W/ LOADBUSTER CROSSARM, TANGENT, 3-5/8 X 4-5/8 IN, 8 FT LG, W/ CENTER MOUNT BRACKET AND HARDWARE, FIBERGLASS, 49 E 80293177 Total Sum of Amount $57.76 $57.76 $0.00 $0.00 $0.00 -$45.61 $72.98 $694.07 $60.96 $12.84 $64.25 $25.95 $885.44 $344.28 $344.28 $282.34 $282.34 $64.20 $401.79 $38.38 $103.59 $328.00 $935.96 $31.13 $31.13 $87.49 $58.42 $235.18 $399.74 $94.11 $874.94 $106.05 $2,478.10 $2,584.15 $438.95 $438.95 $1,287.90 $1,287.90 $255.98 $255.98 $10.14 $30.23 $60.94 $101.31 $69.16 $69.16 $35.09 $64.20 $99.29 $399.54 $399.54 $139.15 $139.15 $37.88 $117.27 $223.65 $378.80

Text of 1-EFO_TLS (GXCOCT) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 39 pages, 14 without text · 42,768 characters

Text of 1-EFO_TLS (GXCOCT) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 32 pages · 59,666 characters

Text of 1-EFO_TLS (GXCOCT) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 32 pages, 2 without text · 59,244 characters

Text of 1-EFO_TLS (GXCOCT) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 24 pages, 6 without text · 35,823 characters

Text of 1-DT7C CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 3,613 characters

Text of 1-DT7C CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 4,323 characters

Text of 1-DT7C CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,342 characters

Text of 1-DSEQ25 CS & Closing Report_Redacted.pdf

Extracted from the file · 22 pages, 3 without text · 30,570 characters

Text of 1-DSEQ24 CS & Closing Report_Redacted.pdf

Extracted from the file · 39 pages, 5 without text · 60,075 characters

Text of 1-DSEQ23 CS & Closing Report_Redacted.pdf

Extracted from the file · 70 pages, 5 without text · 125,645 characters

Text of 1-DSEQ22 CS & Closing Report_Redacted.pdf

Extracted from the file · 125 pages, 43 without text · 128,306 characters

Text of 1-DSEQ CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 4,154 characters

Text of 1-DSEQ CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 8 pages · 8,495 characters

Text of 1-DSEQ CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 4,064 characters

Text of 1-DSEQ CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 15 pages, 9 without text · 11,673 characters

Text of 1-DSCN25 CS & Closing Report_Redacted.pdf

Extracted from the file · 16 pages, 5 without text · 18,398 characters

Text of 1-DSCN24 CS & Closing Report_Redacted.pdf

Extracted from the file · 34 pages, 3 without text · 57,051 characters

Text of 1-DSCN23 CS & Closing Report_Redacted.pdf

Extracted from the file · 124 pages, 11 without text · 171,439 characters

Text of 1-DSCN22 CS & Closing Report_Redacted.pdf

Extracted from the file · 66 pages, 4 without text · 100,282 characters

Text of 1-DSCN CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 13 pages, 5 without text · 13,332 characters

Text of 1-DSCN CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 16 pages · 29,779 characters

Text of 1-DSCN CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 16 pages, 5 without text · 20,407 characters

Text of 1-DSCN CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 16 pages, 3 without text · 25,533 characters

Text of 1-DOT25 CS & Closing Report.pdf

Extracted from the file · 4 pages · 3,828 characters

Text of 1-DOT24 CS & Closing Report.pdf

Extracted from the file · 6 pages · 5,701 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 189 pages, 31 without text · 259,652 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 217 pages · 383,224 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 201 pages · 425,612 characters

Text of 1-DB_CABLE (101395) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 200 pages, 4 without text · 421,923 characters

Text of 1-CTWEDV23 CS & Closing Report_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,169 characters

Text of 1-CTTTRN22 CS & Closing Report_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 5,698 characters

Text of 1-CTTRN25 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,268 characters

Text of 1-CTTRN24 CS & Closing Report_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 5,157 characters

Text of 1-CTTRN23 CS & Closing Report_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 3,972 characters

Text of 1-CTTRN22 CS & Closing Report_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 5,543 characters

Text of 1-CTTOOL25 CS & Closing Report.pdf

Extracted from the file · 5 pages · 3,895 characters

Text of 1-CTTOOL24 CS & Closing Report_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 3,287 characters

Text of 1-CTTOOL23 CS & Closing Report_Redacted.pdf

Extracted from the file · 6 pages, 2 without text · 4,423 characters

Text of 1-CTTOOL22 CS & Closing Report_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 2,987 characters

Text of 1-CTREL25 CS & Closing Report_Redacted.pdf

Extracted from the file · 45 pages, 4 without text · 43,481 characters

Text of 1-CTREL24 CS & Closing Report_Redacted.pdf

Extracted from the file · 78 pages, 2 without text · 84,144 characters

Text of 1-CTREL23 CS & Closing Report_Redacted.pdf

Extracted from the file · 151 pages, 3 without text · 157,716 characters

Text of 1-CTMTR25 CS & Closing Report_Redacted.pdf

Extracted from the file · 11 pages, 2 without text · 22,658 characters

Text of 1-CTMTR24 CS & Closing Report_Redacted.pdf

Extracted from the file · 14 pages, 2 without text · 26,503 characters

Text of 1-CTMTR23 CS & Closing Report_Redacted.pdf

Extracted from the file · 13 pages, 2 without text · 23,843 characters

Text of 1-CTMTR22 CS & Closing Report_Redacted.pdf

Extracted from the file · 18 pages, 3 without text · 33,318 characters

Text of 1-CTFT2022 CS & Closing Report_Redacted.pdf

Extracted from the file · 8 pages, 3 without text · 8,560 characters

Text of 1-CTEDVH25 CS & Closing Report_Redacted.pdf

Extracted from the file · 15 pages, 1 without text · 15,388 characters

Text of 1-CTEDVH24 CS & Closing Report_Redacted.pdf

Extracted from the file · 18 pages, 2 without text · 18,921 characters

Text of 1-CTEDVH23 CS & Closing Report_Redacted.pdf

Extracted from the file · 32 pages, 2 without text · 37,010 characters

Text of 1-CTEDVH22 CS & Closing Report_Redacted.pdf

Extracted from the file · 34 pages, 5 without text · 34,465 characters

Text of 1-CTCSTRN24 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,290 characters

Text of 1-CTCSTRN23 CS & Closing Report_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,465 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 1,791 pages · 3,454,904 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 1,893 pages · 3,336,587 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 1,753 pages · 3,078,653 characters

Text of 1-CSTMER (CDCDANNL) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 1,560 pages · 3,051,094 characters

Text of 1-CDMHANNL CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,167 characters

Text of 1-CDMHANNL CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 2,317 characters

Text of 1-CDMHANNL CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 4,378 characters

Text of 1-CDMHANNL CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 5,557 characters

Text of 1-CD00412 CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 5,653 characters

Text of 1-CD00412 (CDNXANNL) CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 2,308 characters

Text of 1-CD00412 (CDNXANNL) CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 4,929 characters

Text of 1-CD00412 (CDNXANNL) CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 7 pages, 2 without text · 11,894 characters

Text of 1-495802 CS & Closing Report 2025_Redacted.pdf

Extracted from the file · 408 pages · 731,702 characters

Text of 1-495802 CS & Closing Report 2024_Redacted.pdf

Extracted from the file · 509 pages · 802,443 characters

Text of 1-495802 CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 637 pages, 17 without text · 1,107,041 characters

Text of 1-495802 CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 240 pages, 7 without text · 410,733 characters

Text of 1-102118 CS & Closing Report 2023_Redacted.pdf

Extracted from the file · 7 pages, 3 without text · 7,423 characters

Text of 1-102118 CS & Closing Report 2022_Redacted.pdf

Extracted from the file · 10 pages, 3 without text · 15,285 characters

Text of 1-25CGVE11 CS & Closing Report.pdf

Extracted from the file · 2 pages · 1,102 characters

Text of 1-1DWANA2022 CS & Closing Report_Redacted.pdf

Extracted from the file · 15 pages, 8 without text · 10,411 characters

Text of 1-1DWANA24 CS & Closing Report_Redacted.pdf

Extracted from the file · 9 pages, 3 without text · 8,623 characters

Text of 1-1DWANA23 CS & Closing Report_Redacted.pdf

Extracted from the file · 11 pages, 6 without text · 7,622 characters

Text of 2-CSTMER (CDCDANNL) PAF_Redacted.pdf

Extracted from the file · 4 pages · 5,350 characters

Text of 3-CTTTRN22 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 3-CTTRN22 Supplemental_Redacted.pdf

Extracted from the file · 2 pages, 1 without text · 2,195 characters

Text of 3-CTTOOL25 2025 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,205 characters

Text of 3-CTTOOL24 2024 Capital Book CL & P Approved PLan.pdf

Extracted from the file · 2 pages · 2,119 characters

Text of 3-CTTOOL23 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 3-CTTOOL22 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 3-CTFT2022 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 3-CTCSTRN24 2024 Capital Book CL & P Approved PLan.pdf

Extracted from the file · 2 pages · 2,119 characters

Text of 3-CTCSTRN23 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 3-CSTMER (CDCDANNL) Supplemental_Redacted (1).pdf

Extracted from the file · 9 pages, 5 without text · 1,435 characters

Text of 3-CSTMER (CDCDANNL) Supplemental_Redacted.pdf

Extracted from the file · 3 pages · 3,163 characters

Text of 3-CDMHANNL24 - Supplemental PAF_Redacted.pdf

Extracted from the file · 7 pages, 5 without text · 2,613 characters

Text of 3-CDMHANNL Supplemental 2025_Redacted.pdf

Extracted from the file · 8 pages, 6 without text · 2,080 characters

Text of 3-CDMHANNL 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 3-CD00412 (CDNXANNL) - Supplemental PAF_Redacted.pdf

Extracted from the file · 8 pages, 5 without text · 3,307 characters

Text of 3-25CGVE11 2025 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,205 characters

Text of 2-VLT_CORR CDDKANNL PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,860 characters

Text of 2-VLT_CORR (CDDKANNL)- PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,859 characters

Text of 2-VLT_CORR (CDDKANNL) 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-VLT_CORR (CDDKANNL) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-VEGDOT22 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 5,845 characters

Text of 2-ROWLN 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-ROWLN 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-ML2510 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,470 characters

Text of 2-ML2410 PAF_Redacted.pdf

Extracted from the file · 6 pages, 4 without text · 1,479 characters

Text of 2-ML2310 PAF_Redacted.pdf

Extracted from the file · 6 pages, 5 without text · 1,379 characters

Text of 2-LN_RLBLTY (CDDRANNL) 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-LN_RLBLTY (CDDRANNL) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-LN_RELO (CDDHANNL) Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-LN_RELO (CDDHANNL) 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-LIGHTNG (D7DA24) PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 1,157 characters

Text of 2-LIGHTNG (D7DA24) 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-LIGHTNG (D7DA24) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-IT1DWANA 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-INSCLMCST (CTINS24) PAF_Redacted (1).pdf

Extracted from the file · 4 pages, 3 without text · 657 characters

Text of 2-INSCLMCST (CTINS24) PAF_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 657 characters

Text of 2-INSCLMCST (CTINS24) 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-INSCLMCST (CTINS24) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-GXTD22 PAF_Redacted.pdf

Extracted from the file · 6 pages, 5 without text · 190 characters

Text of 2-GXTD11 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-GXENG 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-GXCOTRBL PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 576 characters

Text of 2-GXCOTRBL PAF 2025_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 576 characters

Text of 2-GXCOTRBL 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-GXCOTRBL 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-ETTCF25 PAF_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 3,764 characters

Text of 2-ETTCF24 PAF_Redacted.pdf

Extracted from the file · 6 pages, 4 without text · 2,911 characters

Text of 2-ETTCF22 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 5,602 characters

Text of 2-ETR2025 PAF_Redacted.pdf

Extracted from the file · 6 pages, 2 without text · 5,399 characters

Text of 2-ETR2024 PAF_Redacted.pdf

Extracted from the file · 6 pages, 4 without text · 3,356 characters

Text of 2-ETR2022 PAF_Redacted.pdf

Extracted from the file · 5 pages, 1 without text · 6,942 characters

Text of 2-EMRGNTLN (CDEMANNL) PAF_Redacted (3).pdf

Extracted from the file · 4 pages, 3 without text · 897 characters

Text of 2-EMRGNTLN (CDEMANNL) PAF_Redacted (2).pdf

Extracted from the file · 4 pages, 3 without text · 1,057 characters

Text of 2-EMRGNTLN (CDEMANNL) PAF_Redacted (1).pdf

Extracted from the file · 4 pages, 3 without text · 1,057 characters

Text of 2-EMRGNTLN (CDEMANNL) PAF_Redacted.pdf

Extracted from the file · 4 pages, 3 without text · 1,057 characters

Text of 2-EFO_TLS (GXCOCT) PAF_Redacted (1).pdf

Extracted from the file · 5 pages, 4 without text · 576 characters

Text of 2-EFO_TLS (GXCOCT) PAF_Redacted.pdf

Extracted from the file · 5 pages · 2,976 characters

Text of 2-EFO_TLS (GXCOCT) Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-EFO_TLS (GXCOCT) 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-DSEQ22 PAF Annual 2022_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,962 characters

Text of 2-DSEQ 2025 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,205 characters

Text of 2-DSEQ 2024 Capital Book CL & P Approved PLan.pdf

Extracted from the file · 2 pages · 2,119 characters

Text of 2-DSEQ 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-DSEQ 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-DSCN22 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,783 characters

Text of 2-DSCN 2025 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,205 characters

Text of 2-DSCN 2024 Capital Book CL & P Approved PLan.pdf

Extracted from the file · 2 pages · 2,119 characters

Text of 2-DSCN 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-DSCN 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 2-DOT25 PAF_Redacted.pdf

Extracted from the file · 4 pages, 2 without text · 3,710 characters

Text of 2-DOT24 PAF_Redacted.pdf

Extracted from the file · 5 pages, 3 without text · 2,791 characters

Text of 2-DB_CABLE (101395) PAF_Redacted (3).pdf

Extracted from the file · 6 pages, 4 without text · 3,604 characters

Text of 2-DB_CABLE (101395) PAF_Redacted (2).pdf

Extracted from the file · 5 pages · 9,705 characters

Text of 2-DB_CABLE (101395) PAF_Redacted (1).pdf

Extracted from the file · 5 pages, 4 without text · 2,880 characters

Text of 2-DB_CABLE (101395) PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 2,880 characters

Text of 2-CTWEDV23 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,651 characters

Text of 2-CTTRN25 2025 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,205 characters

Text of 2-CTTRN24 2024 Capital Book CL & P Approved PLan.pdf

Extracted from the file · 2 pages · 2,119 characters

Text of 2-CTTRN23 2023 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,176 characters

Text of 2-CTTRN22 PAF_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 3,051 characters

Text of 2-CTREL25 PAF_Redacted.pdf

Extracted from the file · 5 pages, 2 without text · 4,028 characters

Text of 2-CTREL24 PAF_Redacted.pdf

Extracted from the file · 5 pages, 4 without text · 3,138 characters

Text of 2-CTMTR25 PAF_Redacted.pdf

Extracted from the file · 6 pages, 3 without text · 4,060 characters

Text of 2-CTMTR22 PAF_Redacted.pdf

Extracted from the file · 3 pages, 1 without text · 3,154 characters

Text of 2-CTEDVH25 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,663 characters

Text of 2-CTEDVH24 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,657 characters

Text of 2-CTEDVH23 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,626 characters

Text of 2-CTEDVH22 PAF_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 1,795 characters

Text of 2-CSTMER (CDCDANNL) PAF_Redacted (2).pdf

Extracted from the file · 4 pages · 5,275 characters

Text of 2-CSTMER (CDCDANNL) PAF_Redacted (1).pdf

Extracted from the file · 4 pages, 3 without text · 1,160 characters

Text of 4-LIGHTNG (D7DA24) 2025 Variance Letter.pdf

Extracted from the file · 3 pages · 6,783 characters

Text of 4-EMRGNTLN (CDEMANNL) 2024 Variance Letter.pdf

Extracted from the file · 3 pages · 7,695 characters

Text of 4-EMRGNTLN (CDEMANNL) 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 4-DWANA24 2024 Variance Letter.pdf

Extracted from the file · 3 pages · 7,695 characters

Text of 4-DT7C 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 4-CTTTRN22 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 4-CTFT2022 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 4-102118 2022 Capital Book CL & P Approved Plan.pdf

Extracted from the file · 2 pages · 2,536 characters

Text of 4-1DWANA2022 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 3-VLT_CORR CDDKANNL Supplemental_Redacted.pdf

Extracted from the file · 7 pages, 6 without text · 1,945 characters

Text of 3-LN_RLBLTY (CDDRANNL) Supplemental_Redacted.pdf

Extracted from the file · 6 pages, 5 without text · 1,261 characters

Text of 3-LIGHTNG (D7DA24) 2023 Variance Letter.pdf

Extracted from the file · 4 pages · 11,169 characters

Text of 3-LIGHTNG (D7DA24) 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 3-INSCLMCST (CTINS24) Supplemental_Redacted.pdf

Extracted from the file · 9 pages, 5 without text · 1,398 characters

Text of 3-INSCLMCST (CTINS24) 2022 Variance Letter.pdf

Extracted from the file · 5 pages · 13,559 characters

Text of 3-ETR2023 Supplemental_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 156 characters

Text of 3-EMRGNTLN (CDEMANNL) Supplemental_Redacted.pdf

Extracted from the file · 7 pages · 9,062 characters

Text of 3-EFO_TLS (GXCOCT) Supplemental_Redacted (1).pdf

Extracted from the file · 8 pages, 5 without text · 559 characters

Text of 3-EFO_TLS (GXCOCT) Supplemental_Redacted.pdf

Extracted from the file · 4 pages · 3,757 characters

Text of 3-DT7C Supplemental Annual 2025_Redacted.pdf

Extracted from the file · 8 pages, 5 without text · 1,297 characters

Text of 3-DT7C Supplemental Annual 2024_Redacted.pdf

Extracted from the file · 3 pages, 2 without text · 371 characters

Text of 3-DSEQ22 Supplemental Annual 2022_Redacted.pdf

Extracted from the file · 9 pages, 8 without text · 1,962 characters

As listed on the current system

Supplement for New App [Filed: 09/25/2026]

This filing on the current system (opens in a new tab)