  1. Page 64 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 64 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CD02340:2024 Trip Saver Program CD02475:2025 Western Large Cusomer Zone 900 Projected 2026 Capital Spend Project Long Description Project CD02340 proposes to install Trip Savers at 1155 fused lateral locations in Connecticut to reduce the number of outages caused by transient type events (Tree, Animal, Lightning, Patrolled Nothing Found).A Trip Saver is a self-powered, electronically controlled, single-phase, cutoutmounted vacuum interrupter recloser. The Trip Saver is designed to eliminate the sustained interruption that occurs when a lateral fuse cutout operates in response to a transient fault. It also can eliminate momentary circuit interruptions that occur when a substation circuit breaker or source-side line recloser would otherwise trip to prevent a lateral fuse cutout from operating in response to a 500,009 transient fault. Smart Switch projects address circuit zones that serves more than 500 customers. Limiting circuit zones to less than 500 customers where possible limits the number of customers that loses power 1,588,100 during a single outage. Project CD02475 addresses circuit zones that serves 900 - 999 customers. CD02519:2025 Htfd Lg Customer Zones SS Smart Switch projects address circuit zones that serves more than 500 customers. Limiting circuit zones to less than 500 customers where possible limits the number of customers that loses power during a single outage. Project CD02519 addresses circuit zones that serves more than 500 244,000 customers. CD02520:2025 Norwalk AWC Smart Switch RWO Smart Switch projects address circuit zones that serves more than 500 customers. Limiting circuit zones to less than 500 customers where possible limits the number of customers that loses power during a single outage. Project 2520 address zones that are ranked in the top 100 in terms of 128,500 customer interruptions in the Norwalk AWC.
  2. Page 65 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 65 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CD02521:Vacufuses Program 2025 Projected 2026 Capital Spend Project Long Description Project CD02521 proposes to install Vacufuses on Distribution transformer locations in Connecticut to reduce the number of outages caused by transient type events (Limbs, Animal, Lightning, Patrolled Nothing Found). A Vacufuse is a self-powered, electronically controlled, single-phase, cutout-mounted vacuum interrupter recloser. The Vacufuse is designed to eliminate the sustained interruption that occurs when a transformer fuse cutout operates in response to a transient fault. This device will save 200,120 outages and reduce trips by troubleshooters by reclosing after a transient fault occurs. CD02538:2025 Eastern-New London SS CI Rank CD02542:2025 Cent. Cheshire AWC SS (CI) - 1 Smart Switch projects address circuit zones that serves more than 500 customers. Limiting circuit zones to less than 500 customers where possible limits the number of customers that loses power during a single outage. Project CD02538 addresses circuit zones ranked in the top 100 due to 36,200 customer outages over the past 4 years. Smart Switch projects address circuit zones that serve more than 500 customers. Limiting circuit zones to less than 500 customers where possible limits the number of customers that will lose power during a single outage. Project CD02542 addresses circuit zones that serve more than 500 customers 846,700 and is ranked in the top 100 based on customers interrupted over the past 4 years.
  3. Page 66 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 66 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CD02562:2025 Single Phase Recloser Project CD02583:Barnes Aerospace 14K9 Windsor Locks CD02717:Eastern TripSaver Optimization FRSMRTSW:FRCST PROJ REL IMPRV SMART SWITCHES SR DOUBLE POLE REMOVALS Projected 2026 Capital Spend Project Long Description Project CD02562 proposes to install Viper SP single phase reclosers at fused lateral locations in Connecticut to reduce the number of outages caused by transient type events (Limbs, Animal, Lightning, Patrolled Nothing Found).A Viper SP recloser is a pole mounted electronically controlled interrupter recloser with full SCADA control and visibility utilizing an SEL 351 control. The Viper SP recloser is designed to eliminate the sustained interruption that occurs when a lateral fuse cutout operates in response to a transient fault. It also can eliminate momentary circuit interruptions that occur when a substation circuit breaker or source-side line recloser would otherwise trip to prevent a lateral fuse cutout from operating in response to a transient fault.In 2025 Viper SP recloser will be installed on fused single-phase laterals that have high fault current magnitudes which would exceed 210,177 other single phase reclosing equipment ratings. This project addresses a customer inquiry into the poor reliability performance of the Windsor Locks 14K9 circuit. The customer is Barnes Aerospace located on Old Kennedy Rd in Windsor, CT. This project will address the 14K9 backbone and the lateral that feeds the customer. The improvements will include adding a new 3-phase recloser and replacing one existing 3-phase recloser with a smart switch. In addition, all pole-top transformers along Old Kennedy Rd that are not already fused will 136,000 be fused. This project addresses trip saver locations where the minimum load requirement is not met year round. Minimum load is required in order for trip savers to operate properly in response to fault 738,387 conditions. 3,879,074 Forecast Project Reliability Improvement Smart Switches 5,000,010
  4. Page 67 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 67 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CD02547:2026 Double Pole Removals UCONN RESILIENT ENERGY CENTER Projected 2026 Capital Spend This initiative captures the cost necessary to perform bare pole removals at double pole locations and is required to the meet the orders of PURA Docket No. 03-03-07. Double pole locations are commonly created when these instances occur: I.Structural and electrical upgrades. II.Pole Integrity projects. III.Other programs including the replacement of poles with third party attachments that cannot be removed or transferred to the new pole during replacement. Attachments are removed or transferred by third parties later following a notification through the Alden 1 database, managed by the single pole administrator. Once all pole attachments have been transferred 5,000,010 to the new pole, the old pole is bare and ready to be removed. 500,000 The proposed project is needed to fund the continuation of the operations of the Eversource Energy Center at the University of Connecticut and the development and operation of the UConn Predictive Storm and Outage models for Eversource Connecticut service territory for the period June 1, 2023, through May 31st, 2028, by regularly updating and improving the model integrating utility specific infrastructure and outage data from the Outage Management System (OMS). This project is part of the 2023-2028 Eversource-UConn Master Agreement for the Eversource Energy Center. EEC23-28:Eversource Energy Center 2023-2028 URD/DB Cable Improvements DB CABLE REPLACE-SPECIFIC PROJ 101395:DIRECT BURIED CABLE REPLACEMENT PRO CD02388:Bristol DB Cable Replacement 15U4 Project Long Description 500,000 26,000,000 26,000,000 This program funds the replacement of direct buried distribution cables in underground residential and commercial developments that are reaching the end of their useful lives or have failed. This 22,684,443 improves reliability for customers served by these cables. 66,200 This project is to address the poor reliabilty of direct buried cable in downtown Bristol.
  5. Page 68 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 68 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CD02438:33M1 Woodridge Lake Cable Replace CD02750:2026 DB Fault Indicator Replacement CD02751:2026 DB Fault Indicator Replacement CD02752:2026 DB Fault Indicator Replacement 5-Facilities Basic Business-FAC Acquisition and Sale LAND - AS 26715:2026 CL&P-D RE & ROW LOB Replacements Projected 2026 Capital Spend Project Long Description Project CD02438 addresses underground reliability issues within the Woodridge Lake community in Goshen, CT. The identified portion of the housing community is fed via the Goshen 33M1 circuit at 23.0kV off Milton Rd, Goshen. The two lateral taps located at P#1372 & P#1373 are comprised a mixture of direct buried #1 AL and 1972-vintage #1 AL Concentric UG conductor. Both taps have experienced a combined 8 outages due to underground equipment failures in 4 years. This poor underground reliability ended up resulting in a customer complaint from the Woodridge Lake Housing Association. New direct buried cable will be installed in conduit to reduce future 994,600 deterioration and to ensure reliable service to the portion of the housing community. The purpose of this project is to fund the 2026 Direct Buried (DB) inspection program and replace approximately 2,390 fault indicators in the Eastern Region and perform inspections of the DB 547,526 equipment. The purpose of this project is to fund the 2026 Direct Buried (DB) inspection program and replace approximately 3,628 fault indicators in the Central Region and perform inspections of the DB 819,499 equipment. The purpose of this project is to fund the 2026 Direct Buried (DB) inspection program and replace approximately 3,778 fault indicators in the Western Region and perform inspections of the DB 887,731 equipment. 28,004,045 26,154,036 200,000 200,000 200,000 CL&P-D Real Estate & Right of Way 2026 Line of Business (LOB) 1,255,000
  6. Page 69 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 69 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category EQUIPMENT - R ML2601:2026 Material Logistics LOB CL&P-D Upgrade, Paving and Other BUILDING - UPO 23768:Building Interior Redesign 23778:Norwalk Windows & Facade Renovation 24774:Restroom Renovation 24780: Electrical Service Redesign Projected 2026 Capital Spend 1,255,000 Project Long Description This is for Material Logistics capital projects for the year 2026. Each year, capital dollars are allocated to the Material Logistics organization to replace, improve, or upgrade Warehouse equipment, shelving, and handling equipment. The projects covered by this authorization are generally related to safety issues and Warehouse functionality. Projects can also be related to 1,255,000 Operational needs and requests or to maintain basic office working standards. 24,699,036 24,699,036 This project is for the New London area work center renovation. The building was constructed in 1930 and last renovated in 1993. The project will accommodate existing needs along with projected 7,400,000 growth and comply with the latest company space guidelines. This project is for the replacement of the exterior windows, doors, and facade at the Norwalk Service Center located on Tindall Ave. The AWC is a 52,000 sq ft facility that was built in the 1920’s for Electric Operations. The AWC services Norwalk and its surrounding communities and houses approximately 100 employees. Water has been infiltrating the brick facade resulting in structural deterioration of the building windows, doors, and brick siding. In addition to the structural damage this is also a safety concern due to the potential of falling brick and/or the development of 2,500,000 mold due to the water infiltration. This project is for the Torrington Restroom/Locker Room Renovation. Outdated plumbing, insufficient ventilation, fire-rated assemblies and fire alarm system will be addressed. These changes will provide energy and water efficiency improvements along with providing adequate space for all 1,750,000 employees. This is for the MadisonElectrical Service Redesign. It will replace the existing electrical service to 3,500,000 the building which is obsolete.
  7. Page 70 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 70 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category 25735:Replace Elec Switchgear 25743:Replace generator Projected 2026 Capital Spend Project Long Description This project is to replace the switchgear at the Berlin Central Warehouse. The existing Switchgear in the Berlin Central Warehouse is at the end of its useful life and requires replacement. It has been identified as having multiple issues during the latest arc-flash study analysis. Due to the age and condition of the equipment, reliability and serviceability are compromised. The equipment is critical to power distribution in the Berlin Central Warehouse and failure of the switchgear would likely result in an extended electrical outage which would halt productivity, security, and life safety features within the building as well as power that is provided to the outdoor equipment stored on site. Replacement parts are no longer available and arc-flash safety requirements cannot be achieved based upon the age and installation of this unit. This project also includes proper guarding of the 25,000 switchgear with the installation of a cage and other safety barriers. 10,000 Berlin Central Warehouse NE Corner Generator Replacement 25761:Chiller/Boiler Replacements This project is for the replacement of one 80-ton chiller, six gas fired boilers along with the installation of two circulating pumps at the 626 Glenbrook Road Stamford CT Electric Operations Facility. This facility is a key electric area work center located in lower Fairfield County and is occupied by 109 Eversource employees. The existing equipment is over 40 years old and has begun to show signs of failure. The replacement of these units will provide adequate heating and cooling 200,000 throughout the facility for all employees. 25767:Elevator Replacement Hartford Elevator has made several attempts to repair the New London elevator. The elevator requires a full modernization to become operational again providing a means for employees with disabilities to reach all floors of the Facility as required by the Americans with Disabilities Act 214,000 (ADA).
  8. Page 71 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 71 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category 26703:CL&P-D Buildings 2026 LOB 26724:Turbine Building Removal 26725:Window Replacement Projected 2026 Capital Spend Project Long Description This project covers emergent facility capital work that is required across CL&P Distributions’s 14 facilities which are made up of approximately 786,000 square footage of building space. These projects will typically include building system failures that require immediate replacement (such as: HVAC systems and electrical transformers/gear, etc.). In addition, this funding will also be used to 5,500,001 rectify code compliance/safety issues that arise throughout the CL&P Distribution facilities. 1,399,999 This project is for the Danielson Turbine Building Removal. This project is for the replacement of the exterior windows, doors, and facade at the Stamford Service Center located on 626 Glenbrook Road, Stamford, CT. The AWC is a 55,000 sq ft facility that was built in 1962 for Electric Operations. The AWC services Stamford and its surrounding communities and houses approximately 112 employees. This project consists of replacing the aging windows and exterior doors that are original to the building. This replacement is needed due to failure of the window and storefront framing, and glass seals and gaskets, which allow air and moisture to enter the adjacent indoor spaces. Replacing the windows and storefront systems, including doors, will provide energy efficiency from heat and cooling loss, reduce maintenance costs on repairs, prevent environmental/health concerns from mold and moisture due to leaks and reduce 1,249,999 outside noise enhancing a better work environment.
  9. Page 72 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 72 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category 26726:Waterbury - Freight - Paving 26727:Replace windows & repoint 26729:Replace Switchgear & Generator Reliability-FAC Major Facilities Upgrades MAJOR-BUILDINGS 24732:East Hampton Bldg Space Reno 26728:Dev of Residential Parcel Projected 2026 Capital Spend Project Long Description The Waterbury Area Work Center is home to 60+ employees (and growing each year) supporting Electric Operations in the Western Region of CT. In addition to Electric Operations, the site also supports Material Logistics storage and Fleet Operations which, not only maintains the company vehicles and equipment on the Freight Street site, but also the company vehicles from 371 Railroad Hill Street, Waterbury. There is also a major substation located on this site. This project is to remove and replace the employee parking lots and major travel lanes approximately 104,000 square feet of pavement and associate curbing and remove three parking lot islands to improve traffic flow and make snow removal more efficient. The Asphalt surfaces have failed due to age (installed in 1998 +/-) and the use well beyond its normal life cycle. The current condition is becoming a 650,000 significant safety issue for pedestrian traffic as well as forklift traffic. This project is for the replacement of the windows including the exterior restoration of the New Britain Facility. Currently the building windows/envelope is deteriorating with water infiltration, 200,004 corrosion and masonry failure which has become a health concern for occupants within. This project is for the replacement of the existing electrical swithgear including building generator at Torrington. The existing switchgear is original to the building with replacement parts/breakers being obsolete, this could be detrimental to the Facility upon a failure. The new emergency generator will 100,031 be designed to capture the entire Facility providing stability upon utility loss. 1,850,009 1,850,009 1,850,009 This project is for the East Hampton area work center building renovation to accommodate 200,000 additional space for increased workforce and the switchgear replacement. 150,009 This project is for the development of acquired residential parcel in Norwalk.
  10. Page 73 of 73

    Connecticut Light and Power Company d/b/a Eversource Energy Docket No. 26-05-10 Exhibit CLP-ADDITIONS-4 Supplemental 3 Page 73 of 73 The Connecticut Light and Power Company d/b/a Eversource Energy Projected 2026 Capital Spend by Project (Whole Dollars) Project Number/Description by Category CTSTORAGE:CT Storage Building in Berlin 6-Information Technology Basic Business-IT Core System Upgrades SOFTWARE - SU IT25054:CT Interconnection Automation IT25060:CACS Upgrade - CL&P IT26020:Modern Desktop Program - 2026 - PC 7-Corporate Other Basic Business-CG Other - CG CUSTOMER - OTHER 26CGMR11:2026 CG Equipment CLP Equipment Projected 2026 Capital Spend Project Long Description This project is to construct a new stand-alone storage building in the Berlin training yard adjacent to the training yard training trailer. The building will contain storage shelves and storage cabinets for 1,500,000 training yard tools and equipment. There will also be dedicated space for hands-on training aids. 4,244,644 4,244,644 4,244,644 4,244,644 This project supports compliance obligations to standardize risk-based assessment for distribution planning, scenarios, and projected grid conditions and build a consistent customer experience in CT. This tool will enable the company to meet expected regulatory requirements in CT related to system 1,962,793 planning and support for the interconnection process. This project is for the Credit and Collection System (CACS) upgrade to version 9.4 and license renewal. The upgrded version will provide several beneficial features which will make the process of managing accounts in Credit and Collections easier and provide new functionality that will 1,462,851 improve customer communication. This will ensure IT security and architecture compliance. 819,000 Modern Desktop Program - 2026 - PC Deployments 1,186,166 1,186,166 1,186,166 1,186,166 This project's goal is to replace failing and end of life meter reading equipment in CT. The 1,186,166 equipment is necessary for the collection of meter reads.
1 part match

As listed on the current system

Supplement for New App [Filed: 11/18/2026]

This filing on the current system (opens in a new tab)