Late-filed exhibits
Exhibits 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14, 15
Files26
LFE-001 GenConn.pdf
PDF · 6 KB · 1 pageText searchable
Download LFE-001 GenConn.pdfRead the text of LFE-001 GenConn.pdf
LFE -001 Attachment 1 (GenConn-02 -Updated).xlsx
Excel · 1.0 MBText searchable
Download LFE -001 Attachment 1 (GenConn-02 -Updated).xlsxRead the text of LFE -001 Attachment 1 (GenConn-02 -Updated).xlsx
LFE-002 GenConn .pdf
PDF · 114 KB · 1 pageText searchable
Download LFE-002 GenConn .pdfRead the text of LFE-002 GenConn .pdf
LFE-002 Attachment 1.pdf
PDF · 402 KB · 31 pagesText searchable
Download LFE-002 Attachment 1.pdfRead the text of LFE-002 Attachment 1.pdf
LFE-003 GenConn.pdf
PDF · 161 KB · 4 pagesText searchable
Download LFE-003 GenConn.pdfRead the text of LFE-003 GenConn.pdf
LFE-004 GenConn.pdf
PDF · 133 KB · 3 pagesText searchable
Download LFE-004 GenConn.pdfRead the text of LFE-004 GenConn.pdf
LFE-005 GenConn.pdf
PDF · 13 KB · 2 pagesText searchable
Download LFE-005 GenConn.pdfRead the text of LFE-005 GenConn.pdf
LFE-006 GenConn.pdf
PDF · 109 KB · 2 pagesText searchable
Download LFE-006 GenConn.pdfRead the text of LFE-006 GenConn.pdf
LFE-006 Attachment 1.pdf
PDF · 7.2 MB · 115 pagesText searchable
Download LFE-006 Attachment 1.pdfRead the text of LFE-006 Attachment 1.pdf
LFE-007 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-007 GenConn.pdfRead the text of LFE-007 GenConn.pdf
LFE-007 Attachment 1.xlsx
Excel · 829 KBText searchable
Download LFE-007 Attachment 1.xlsxRead the text of LFE-007 Attachment 1.xlsx
LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
Excel · 935 KBText searchable
Download LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsxRead the text of LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
LFE-008 GenConn.pdf
PDF · 8 KB · 1 pageText searchable
Download LFE-008 GenConn.pdfRead the text of LFE-008 GenConn.pdf
LFE-008 Attachment 1.pdf
PDF · 1.2 MB · 42 pagesText searchable
Download LFE-008 Attachment 1.pdfRead the text of LFE-008 Attachment 1.pdf
LFE-008 Attachment 2.xlsx
Excel · 91 KBText searchable
Download LFE-008 Attachment 2.xlsxRead the text of LFE-008 Attachment 2.xlsx
LFE-009 GenConn.pdf
PDF · 8 KB · 1 pageText searchable
Download LFE-009 GenConn.pdfRead the text of LFE-009 GenConn.pdf
LFE-010 GenConn.pdf
PDF · 14 KB · 2 pagesText searchable
Download LFE-010 GenConn.pdfRead the text of LFE-010 GenConn.pdf
LFE-010 Attachment 1.pdf
PDF · 3.9 MB · 178 pagesText searchable
Download LFE-010 Attachment 1.pdfRead the text of LFE-010 Attachment 1.pdf
LFE-011 GenConn.pdf
PDF · 104 KB · 1 pageText searchable
Download LFE-011 GenConn.pdfRead the text of LFE-011 GenConn.pdf
LFE-011 Attachment 1.xlsx
Excel · 73 KBText searchable
Download LFE-011 Attachment 1.xlsxRead the text of LFE-011 Attachment 1.xlsx
LFE-012 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-012 GenConn.pdfRead the text of LFE-012 GenConn.pdf
LFE-012 Attachment 1 REDACTED.pdf
PDF · 16 KB · 1 pageText searchable
Download LFE-012 Attachment 1 REDACTED.pdfRead the text of LFE-012 Attachment 1 REDACTED.pdf
LFE-014 GenConn.pdf
PDF · 6 KB · 1 pageText searchable
Download LFE-014 GenConn.pdfRead the text of LFE-014 GenConn.pdf
LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
PDF · 404 KB · 8 pagesText searchable
Download LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdfRead the text of LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
LFE-015 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-015 GenConn.pdfRead the text of LFE-015 GenConn.pdf
LFE-009 Attachment 1.xlsx
Excel · 21 MBText searchable
Download LFE-009 Attachment 1.xlsxRead the text of LFE-009 Attachment 1.xlsx
Text of LFE-001 GenConn.pdf
Extracted from the file · 1 page · 535 characters
Text of LFE-002 GenConn .pdf
Extracted from the file · 1 page · 1,167 characters
Text of LFE-004 GenConn.pdf
Extracted from the file · 3 pages · 4,954 characters
Text of LFE-005 GenConn.pdf
Extracted from the file · 2 pages · 2,975 characters
Text of LFE-006 GenConn.pdf
Extracted from the file · 2 pages · 4,578 characters
Text of LFE-006 Attachment 1.pdf
Extracted from the file · 115 pages · 296,451 characters
Text of LFE-007 GenConn.pdf
Extracted from the file · 1 page · 1,613 characters
Text of LFE-007 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-008 GenConn.pdf
Extracted from the file · 1 page · 2,438 characters
Text of LFE-008 Attachment 1.pdf
Extracted from the file · 42 pages · 58,655 characters
Text of LFE-008 Attachment 2.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-009 GenConn.pdf
Extracted from the file · 1 page · 1,386 characters
Text of LFE-010 GenConn.pdf
Extracted from the file · 2 pages · 3,322 characters
Page 2 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 2 of 178 Catalyst Performance Test TECHNICIAN: TEST DATE: TEST REACTOR: Customer: Project Name: Customer P.O. #: Catalyst Manufacturer: Module Number: Date of Manufacture: Project #: Additional Comments: Peter Bartolomeo 11/19/2019 Button NRG GennConn Middletown 4501903349 BASF SN-020 Unknown SO-027142 Unit 13, installed 1/28/11, removed 10/10/19 Contaminant Tested Temp @ Contaminant Contaminant Catalyst Inlet Out In CO VOC (Toluene) (oF) 680 680 (ppm) 72 74 (ppm) 2.8 2.2 PreShipment Test: As-Received/PreWash Test: Post Wash Test: Recoated: Exposed to Exhaust Gas: Foil Sample Taken: % DRE (%) 96.1% 97.1% Performance Requirements: % DRE 95.5% 84.5% TEMP (°F) 680 680 DRE = destruction and removal efficiency = Contaminant concentration in, minus out, divided by in CO = carbon monoxide VOC = volatile organic compound CO Data Sheet & Test Report Unit 13 SN-020Page 3 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 3 of 178 Catalyst Performance Test TECHNICIAN: TEST DATE: TEST REACTOR: Customer: Project Name: Customer P.O. #: Catalyst Manufacturer: Module Number: Date of Manufacture: Project #: Additional Comments: Peter Bartolomeo 11/19/2019 Button NRG GennConn Middletown 4501903349 BASF SN-009 Unknown SO-027142 Unit 14, installed 2/15/11, removed 10/17/19 Contaminant Tested Temp @ Contaminant Contaminant Catalyst Inlet Out In CO VOC (Toluene) (oF) 681 681 (ppm) 74 76 (ppm) 2.7 1.8 PreShipment Test: As-Received/PreWash Test: Post Wash Test: Recoated: Exposed to Exhaust Gas: Foil Sample Taken: % DRE (%) 96.3% 97.6% Performance Requirements: % DRE 95.5% 84.5% TEMP (°F) 680 680 DRE = destruction and removal efficiency = Contaminant concentration in, minus out, divided by in CO = carbon monoxide VOC = volatile organic compound CO Data Sheet & Test Report Unit 14 SN-009Page 4 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 4 of 178 Catalyst Performance Test TECHNICIAN: TEST DATE: TEST REACTOR: Customer: Project Name: Customer P.O. #: Catalyst Manufacturer: Module Number: Date of Manufacture: Project #: Additional Comments: Peter Bartolomeo 11/19/2019 Button NRG GennConn Middletown 4501903349 BASF SN-004 Unknown SO-027142 Unit 15, installed 2/28/11, removed 10/27/19 Contaminant Tested Temp @ Contaminant Contaminant Catalyst Inlet Out In CO VOC (Toluene) (oF) 678 678 (ppm) 72 71 (ppm) 2.6 1.6 PreShipment Test: As-Received/PreWash Test: Post Wash Test: Recoated: Exposed to Exhaust Gas: Foil Sample Taken: % DRE (%) 96.3% 97.8% Performance Requirements: % DRE 95.5% 84.5% TEMP (°F) 680 680 DRE = destruction and removal efficiency = Contaminant concentration in, minus out, divided by in CO = carbon monoxide VOC = volatile organic compound CO Data Sheet & Test Report Unit 15 SN-004Page 5 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 5 of 178 Catalyst Performance Test TECHNICIAN: TEST DATE: TEST REACTOR: Customer: Project Name: Customer P.O. #: Catalyst Manufacturer: Module Number: Date of Manufacture: Project #: Additional Comments: Contaminant Tested CO VOC (Toluene) Peter Bartolomeo 5/10/2019 1 NRG Genn Conn, Devon 4501881625 EmeraChem, LLC EC-EIT-011 (23) Feb-10 RMA-6699 Unit 16; removed 4/16/19 PreShipment Test: As-Received/PreWash Test: Post Wash Test: Recoated: Exposed to Exhaust Gas: Foil Sample Taken: Temp @ Contaminant Contaminant Catalyst Inlet Out In (oF) 682 682 (ppm) 194 228 (ppm) 5 18 % DRE (%) 97.6% 92.2% Performance Requirements: % DRE 95.5% 84.5% TEMP (°F) 680 680 Pass/Fail PASS PASS DRE = destruction and removal efficiency = Contaminant concentration in, minus out, divided by in CO = carbon monoxide VOC = volatile organic compound CO Data Sheet & Test Report EC-EIT-011 as-recievedPage 6 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 6 of 178 Catalyst Performance Test TECHNICIAN: TEST DATE: TEST REACTOR: Customer: Project Name: Customer P.O. #: Catalyst Manufacturer: Module Number: Date of Manufacture: Project #: Additional Comments: Contaminant Tested CO VOC (Toluene) Peter Bartolomeo 5/9/2019 1 NRG Genn Conn, Devon 4501881625 EmeraChem, LLC EC-EIT-040 (9) Feb-10 RMA-6699 Unit 18 East; removed 4/29/19 PreShipment Test: As-Received/PreWash Test: Post Wash Test: Recoated: Exposed to Exhaust Gas: Foil Sample Taken: Temp @ Contaminant Contaminant Catalyst Inlet Out In (oF) 687 687 (ppm) 188 198 (ppm) 4 12 % DRE (%) 97.8% 93.7% Performance Requirements: % DRE 95.5% 84.5% TEMP (°F) 680 680 Pass/Fail PASS PASS DRE = destruction and removal efficiency = Contaminant concentration in, minus out, divided by in CO = carbon monoxide VOC = volatile organic compound CO Data Sheet & Test Report EC-EIT-040 as-recievedPage 7 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 NRG GenConn Devon Power Unit 15 SCR Catalyst Performance Test Report 728 Operating Hours 88 Months Since First Gas-In Submitted by CORMETECH, INC. Environmental Technologies 5000 International Drive Durham, NC 27712 [phone removed] John A. Nivens Sr. Engineering Technician Mark Conger Sr. Project Engineer Certifying Laboratory Representative Silas Christian, Laboratory Manager February 7, 2018 CORMETECH CONFIDENTIAL This document and attachments, if any, contain confidential/proprietary information and is submitted without consideration other than the recipient's agreement that it shall not be reproduced, copied, lent, or disposed of directly or indirectly nor used for any purpose other than that for which it is specifically furnished. Page 7 of 178Page 8 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 8 of 178 NRG GenConn Devon Power Unit 15 February 7, 2018 SCR Catalyst Performance Test Report TABLE OF CONTENTS EXECUTIVE SUMMARY ................................................................................................................ 3 PURPOSE ...................................................................................................................................... 4 BACKGROUND .............................................................................................................................. 4 FACILITY OPERATIONAL HISTORY ............................................................................................. 6 PROCEDURE OVERVIEW ............................................................................................................. 7 FIELD SAMPLING AND UNIT OPERATING CONDITIONS ............................................................ 8 LABORATORY PERFORMANCE TEST CONDITIONS .................................................................. 9 RESULTS ..................................................................................................................................... 10 FIELD DATA COMMENTARY....................................................................................................... 13 RECOMMENDATIONS ................................................................................................................. 14 APPENDIX 1: Location of Sample Retrieval .................................................................................. 15 APPENDIX 2: Field Records ......................................................................................................... 16 APPENDIX 3: Performance Test Standard Procedure .................................................................. 18 CORMETECH Confidential www.cormetech.com | 2 5000 International Drive Durham, North Carolina 27712 USAPage 9 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 9 of 178 NRG GenConn Devon Power Unit 15 February 7, 2018 SCR Catalyst Performance Test Report EXECUTIVE SUMMARY The following summarizes the key results for this audit of the NRG GenConn Devon Power Unit 15 SCR after 88 months and 728 operating hours since first gas-in. Observations and Predictions This audit of the GenConn Devon Power Unit 15 SCR catalyst shows a measurable decrease in catalytic potential of the SCR catalyst, as measured by lab-scale testing. Based on the results of this audit, the SCR catalyst installed for GenConn Devon Power Unit 15 is above the performance threshold and is projected to continue to meet the field performance requirements of 85.9% NOX reduction at 5 ppmvdc ammonia slip for at least an additional 1,200 operating hours from the date this sample was removed. Due to the low operating hours and that this is the first audit, the life prediction is likely conservative. This prediction assumes that catalyst deactivation will continue at the same rate as measured over the operating hours to date. If this rate of deactivation changes, the prediction of remaining catalyst life will change accordingly; therefore, Cormetech recommends performing regular field performance and laboratory catalyst audits. Field Data Commentary Based on the provided operational data, GenConn Devon Power Unit 15 is operating well in the field and meeting permit limits. The measured ammonia slip and flow rate are lower than expected given the other parameters and lab measured activity of the catalyst, indicating good performance. In both oil fired and gas fired conditions, the outlet NOx is being driven well below the permit limit. This increases the NOx reduction efficiency resulting in a higher level of performance than the design of the catalyst. As the catalyst deactivates over time the outlet NO x will need to be maintained closer to the permit requirements to maintain ammonia slip under 5 ppmvdc. Recommendations Regular laboratory catalyst testing is recommended to refine the accuracy of the remaining catalyst life prediction. The next audit should occur after an additional 600 hours of operation or three years, whichever is first, from the time the sample for this audit was removed. Continued review of field test data to accurately confirm actual performance requirements, operating conditions, and system scale-up factors, and thereby the appropriate laboratory scale performance threshold is recommended. CORMETECH Confidential www.cormetech.com | 3 5000 International Drive Durham, North Carolina 27712 USAPage 10 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 10 of 178 NRG GenConn Devon Power Unit 15 February 7, 2018 SCR Catalyst Performance Test Report PURPOSE This test is conducted to audit the catalytic potential of an SCR catalyst by measuring the performance of a field catalyst sample that has been in operation for a known duration. The catalytic potential is measured by laboratory scale testing of field samples removed from the SCR. Performance tests are conducted in a controlled, laboratory environment allowing accurate comparisons of field sample catalytic potential to that of fresh catalyst. The deactivation rate is determined by comparing the change in catalytic potential to the operating hours of the sample. Field performance, as indicated by plant-supplied measurements and observations, is also analyzed and discussed relative to the performance of the catalyst samples tested. Measured field performance in conjunction with laboratory measurements of field sample catalytic potential is used to determine actual unit scale-up factors. Utilizing actual unit scale-up factors significantly improves the accuracy of future performance predictions. Further catalyst and/or field operation analysis may be recommended if laboratory test results are inconsistent with any of the following: Cormetech’s experience base of comparable units The plant’s reported field performance, if available The results of previous audits of the unit, if applicable The performance expectations for the unit. BACKGROUND In order to achieve the design performance requirements of a Selective Catalytic Reduction system for a specified timeframe (life) of the SCR catalyst, the catalyst formulation, structure, and volume are specifically designed to accommodate the system operating conditions, the predicted system scale-up factors, and a predicted rate of decrease in catalyst potential over time. If any of the design or operating parameters above is not realized, then the actual duration that the design performance requirements can be met may deviate from the design life. The individual contribution of each parameter on actual life is described below. In actual practice, one or more of these parameters may deviate from design and either counteract or complement each other. Performance Requirements: If the actual plant performance requirements are more severe than the design performance requirements, actual life will be less than design life. An example of this would be a unit that is required to achieve a higher NOx reduction than the unit was designed for. Operating Conditions: Flue gas flow rate, inlet NOX levels, temperature, oxygen content, and water content impact catalytic potential. If the catalyst is at an operating condition where the potential is lower than design, actual life will be less than design life. Scale-Up Factors: The full NOX reduction potential of the catalyst is not attained in the field due to non-ideal flow distribution, temperature distribution, ammonia to NOX molar ratio distribution, CORMETECH Confidential www.cormetech.com | 4 5000 International Drive Durham, North Carolina 27712 USAPage 11 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 11 of 178 NRG GenConn Devon Power Unit 15 February 7, 2018 SCR Catalyst Performance Test Report catalyst blockage, and/or flue gas bypass. Collectively, these non-ideal conditions are accounted for with ‘system scale-up factors’. If the overall actual system scale-up factors are more severe than the design scale-up factors, then the potential of the SCR system to meet a given performance requirement is reduced. Catalyst Deactivation Rate: Catalytic potential decreases over time. This catalyst deactivation rate has a direct impact on actual life. If the deactivation rate is more than design, then actual life is effectively reduced. If the deactivation rate is less than design, the actual life is effectively increased. If the performance requirements, operating conditions, and/or scale-up factors are more severe than the initial design, less margin remains for catalyst deactivation. Therefore, actual life will be less than design life. At any given time and operating condition, the SCR system performance is dictated by the NOX reduction potential of the catalyst and the system scale-up factors. These factors reduce performance from the catalytic potential to the performance achievable in the operating SCR system. Performance tests are purposefully conducted in a controlled environment, free from the scaleup factors that adversely affect SCR system performance, and at repeatable operating conditions, so that changes in catalytic potential may be evaluated accurately. Catalyst deactivation is determined by testing the field catalyst sample at the same operating conditions as the fresh sample. In conjunction with performance test results, analysis of field SCR system performance data can confirm the field performance requirements, the plant operating conditions, and actual system scale-up factors. Cormetech’s SCR catalyst design and testing experience enables analysis of the actual versus design values of performance requirements, operating conditions, system scale-up, and catalyst deactivation to predict future catalyst performance. CORMETECH Confidential www.cormetech.com | 5 5000 International Drive Durham, North Carolina 27712 USA
Text of LFE-011 GenConn.pdf
Extracted from the file · 1 page · 2,796 characters
Text of LFE-011 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-012 GenConn.pdf
Extracted from the file · 1 page · 982 characters
Text of LFE-012 Attachment 1 REDACTED.pdf
Extracted from the file · 1 page · 2,492 characters
Text of LFE-014 GenConn.pdf
Extracted from the file · 1 page · 351 characters
Text of LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
Extracted from the file · 8 pages · 12,688 characters
Text of LFE-015 GenConn.pdf
Extracted from the file · 1 page · 1,318 characters
Text of LFE-009 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
As listed on the current system
LFEs Filed (Avangrid) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14, 15 Date Filed: 10/19/2026