Late-filed exhibits
Exhibits 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14, 15
Files26
LFE-001 GenConn.pdf
PDF · 6 KB · 1 pageText searchable
Download LFE-001 GenConn.pdfRead the text of LFE-001 GenConn.pdf
LFE -001 Attachment 1 (GenConn-02 -Updated).xlsx
Excel · 1.0 MBText searchable
Download LFE -001 Attachment 1 (GenConn-02 -Updated).xlsxRead the text of LFE -001 Attachment 1 (GenConn-02 -Updated).xlsx
LFE-002 GenConn .pdf
PDF · 114 KB · 1 pageText searchable
Download LFE-002 GenConn .pdfRead the text of LFE-002 GenConn .pdf
LFE-002 Attachment 1.pdf
PDF · 402 KB · 31 pagesText searchable
Download LFE-002 Attachment 1.pdfRead the text of LFE-002 Attachment 1.pdf
LFE-003 GenConn.pdf
PDF · 161 KB · 4 pagesText searchable
Download LFE-003 GenConn.pdfRead the text of LFE-003 GenConn.pdf
LFE-004 GenConn.pdf
PDF · 133 KB · 3 pagesText searchable
Download LFE-004 GenConn.pdfRead the text of LFE-004 GenConn.pdf
LFE-005 GenConn.pdf
PDF · 13 KB · 2 pagesText searchable
Download LFE-005 GenConn.pdfRead the text of LFE-005 GenConn.pdf
LFE-006 GenConn.pdf
PDF · 109 KB · 2 pagesText searchable
Download LFE-006 GenConn.pdfRead the text of LFE-006 GenConn.pdf
LFE-006 Attachment 1.pdf
PDF · 7.2 MB · 115 pagesText searchable
Download LFE-006 Attachment 1.pdfRead the text of LFE-006 Attachment 1.pdf
LFE-007 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-007 GenConn.pdfRead the text of LFE-007 GenConn.pdf
LFE-007 Attachment 1.xlsx
Excel · 829 KBText searchable
Download LFE-007 Attachment 1.xlsxRead the text of LFE-007 Attachment 1.xlsx
LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
Excel · 935 KBText searchable
Download LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsxRead the text of LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
LFE-008 GenConn.pdf
PDF · 8 KB · 1 pageText searchable
Download LFE-008 GenConn.pdfRead the text of LFE-008 GenConn.pdf
LFE-008 Attachment 1.pdf
PDF · 1.2 MB · 42 pagesText searchable
Download LFE-008 Attachment 1.pdfRead the text of LFE-008 Attachment 1.pdf
LFE-008 Attachment 2.xlsx
Excel · 91 KBText searchable
Download LFE-008 Attachment 2.xlsxRead the text of LFE-008 Attachment 2.xlsx
LFE-009 GenConn.pdf
PDF · 8 KB · 1 pageText searchable
Download LFE-009 GenConn.pdfRead the text of LFE-009 GenConn.pdf
LFE-010 GenConn.pdf
PDF · 14 KB · 2 pagesText searchable
Download LFE-010 GenConn.pdfRead the text of LFE-010 GenConn.pdf
LFE-010 Attachment 1.pdf
PDF · 3.9 MB · 178 pagesText searchable
Download LFE-010 Attachment 1.pdfRead the text of LFE-010 Attachment 1.pdf
LFE-011 GenConn.pdf
PDF · 104 KB · 1 pageText searchable
Download LFE-011 GenConn.pdfRead the text of LFE-011 GenConn.pdf
LFE-011 Attachment 1.xlsx
Excel · 73 KBText searchable
Download LFE-011 Attachment 1.xlsxRead the text of LFE-011 Attachment 1.xlsx
LFE-012 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-012 GenConn.pdfRead the text of LFE-012 GenConn.pdf
LFE-012 Attachment 1 REDACTED.pdf
PDF · 16 KB · 1 pageText searchable
Download LFE-012 Attachment 1 REDACTED.pdfRead the text of LFE-012 Attachment 1 REDACTED.pdf
LFE-014 GenConn.pdf
PDF · 6 KB · 1 pageText searchable
Download LFE-014 GenConn.pdfRead the text of LFE-014 GenConn.pdf
LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
PDF · 404 KB · 8 pagesText searchable
Download LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdfRead the text of LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
LFE-015 GenConn.pdf
PDF · 7 KB · 1 pageText searchable
Download LFE-015 GenConn.pdfRead the text of LFE-015 GenConn.pdf
LFE-009 Attachment 1.xlsx
Excel · 21 MBText searchable
Download LFE-009 Attachment 1.xlsxRead the text of LFE-009 Attachment 1.xlsx
Text of LFE-001 GenConn.pdf
Extracted from the file · 1 page · 535 characters
Text of LFE-002 GenConn .pdf
Extracted from the file · 1 page · 1,167 characters
Text of LFE-004 GenConn.pdf
Extracted from the file · 3 pages · 4,954 characters
Text of LFE-005 GenConn.pdf
Extracted from the file · 2 pages · 2,975 characters
Text of LFE-006 GenConn.pdf
Extracted from the file · 2 pages · 4,578 characters
Text of LFE-006 Attachment 1.pdf
Extracted from the file · 115 pages · 296,451 characters
Text of LFE-007 GenConn.pdf
Extracted from the file · 1 page · 1,613 characters
Text of LFE-007 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-007 Attachment 2 (RRU-031 Attachment 1-Corrected).xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-008 GenConn.pdf
Extracted from the file · 1 page · 2,438 characters
Text of LFE-008 Attachment 1.pdf
Extracted from the file · 42 pages · 58,655 characters
Text of LFE-008 Attachment 2.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-009 GenConn.pdf
Extracted from the file · 1 page · 1,386 characters
Text of LFE-010 GenConn.pdf
Extracted from the file · 2 pages · 3,322 characters
Page 77 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 77 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report catalyst blockage, and/or flue gas bypass. Collectively, these non-ideal conditions are accounted for with ‘system scale-up factors’. If the overall actual system scale-up factors are more severe than the design scale-up factors, then the potential of the SCR system to meet a given performance requirement is reduced. Catalyst Deactivation Rate: Catalytic potential decreases over time. This catalyst deactivation rate has a direct impact on actual life. If the deactivation rate is more than design, then actual life is effectively reduced. If the deactivation rate is less than design, the actual life is effectively increased. If the performance requirements, operating conditions, and/or scale-up factors are more severe than the initial design, less margin remains for catalyst deactivation. Therefore, actual life will be less than design life. At any given time and operating condition, the SCR system performance is dictated by the NO X reduction potential of the catalyst and the system scale-up factors. These factors reduce performance from the catalytic potential to the performance achievable in the operating SCR system. Performance tests are purposefully conducted in a controlled environment, free from the scaleup factors that adversely affect SCR system performance, and at repeatable operating conditions, so that changes in catalytic potential may be evaluated accurately. Catalyst deactivation is determined by testing the field catalyst sample at the same operating conditions as the fresh sample. In conjunction with performance test results, analysis of field SCR system performance data can confirm the field performance requirements, the plant operating conditions, and actual system scale-up factors. Cormetech’s SCR catalyst design and testing experience enables analysis of the actual versus design values of performance requirements, operating conditions, system scale-up, and catalyst deactivation to predict future catalyst performance. CORMETECH Confidential www.cormetech.com | 5 5000 International Drive Durham, North Carolina 27712 USAPage 78 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 78 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report FACILITY OPERATIONAL HISTORY The SCR system at the GenConn Devon Power Unit 18 consists of 1 layer of CM21MHTTM 70 cell catalyst. The unit was originally put into service on July 2010. On April 29, 2019 on catalyst sample was removed from the field sampler at GenConn Devon Power Unit 18 and returned to Cormetech for laboratory testing. At the time the sample was removed, the audited element had accumulated 845 operating hours. The results of the April 29, 2019 audit are summarized in this report. CORMETECH Confidential www.cormetech.com | 6 5000 International Drive Durham, North Carolina 27712 USAPage 79 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 79 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report PROCEDURE OVERVIEW 1. One catalyst sample was removed from the field sampler module at the GenConn Devon Power Unit 18 SCR and was shipped to Cormetech’s laboratory. Operating history was recorded by the plant and forwarded to Cormetech. 2. The physical condition of the catalyst was documented by Cormetech. 3. The catalyst was prepared and loaded into an Activity Test Apparatus and then evaluated at the original design conditions for the SCR. The Performance Test Standard Procedure is included in Appendix 3. 4. The results include catalyst potential expressed as NOX removal efficiency at a constant 5 ppmvdc ammonia slip. 5. Test results were compared to design expectations and to the results of the fresh reference and previous audit. Expectations of catalyst deactivation were determined by the time online and experience data of similar gas-fired facilities. 6. A catalyst life prediction is based on the above testing and analysis. 7. Additional data submitted by the plant was reviewed for the field performance of the SCR system. CORMETECH Confidential www.cormetech.com | 7 5000 International Drive Durham, North Carolina 27712 USAPage 80 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 80 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report FIELD SAMPLING AND UNIT OPERATING CONDITIONS Field Sampling One SCR catalyst sample from GenConn Devon Power Unit 18 was removed and sent to Cormetech's Laboratory for evaluation. The sample retrieval location is shown in Appendix 1. Operating Status Field records supplied by GenConn Devon Power are summarized in the table below. The field records are reproduced in Appendix 2. First Gas-In Date with Catalyst Installed Sample Removal Date April 29, 2019 Total Operating Hours On Catalyst Sample 845 Ultra-Low Sulfur Kerosene Primary Fuel Fired Hours Burning Primary Fuel 707 Secondary Fuel Fired Natural Gas Hours Burning Secondary Fuel 138 Number of Starts and Stops since catalyst was installed 197 CORMETECH Confidential www.cormetech.com July 2010 | 8 5000 International Drive Durham, North Carolina 27712 USAPage 81 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 81 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report LABORATORY PERFORMANCE TEST CONDITIONS A performance test was conducted on the sample received using the conditions below. These conditions reflect the original design conditions for which there is fresh catalyst test data available for direct comparison. Temperature 442OC (828OF) Entrance Gas Velocity 3.84 Nm/s O2 Inlet NOX CORMETECH Confidential www.cormetech.com 14.4 vol% dry 46.0 ppmvd @ 14.4% O2 (42.0 ppmvdc @ 15% O2) | 9 5000 International Drive Durham, North Carolina 27712 USAPage 82 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 82 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report RESULTS Sample Visual Inspection One field sample was received from the GenConn Devon Power Unit 18 SCR. Below are photographs of the flow entrance face and the flow exit face of the element with an as received inspection report. Element ID 2388-1026-0462 Box Markings GenConn Devon Power Attn: Paul Bukowsky #2388 Box 2 of 2 SCR Replacment Nox catalyst coupon #18 Sample Markings GenConn Devon Unit #18 Removed 4/29/19 Flow Direction Marked Yes Other Markings None Visual Inspection Notes Product Description Length, mm Blocked Cell Count, as received Blocked Cell Count, after light cleaning Flow Entrance CORMETECH Confidential www.cormetech.com Sample is split in the middle but in testable condition CM21MHTtM 70 X 70 cell array 447 0 0 Flow Exit | 10 5000 International Drive Durham, North Carolina 27712 USAPage 83 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 83 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report Results of Laboratory Tests The catalyst performance below is reported under constant 5 ppmvdc ammonia slip and design operating conditions. The lab performance threshold represents the design NOX removal efficiency, as measured in lab apparatus, at which the actual field performance at design operating conditions is expected to reach end-of-life. Field performance is based on a design performance requirement of 85.9% NOX removal efficiency and 5 ppmvdc ammonia slip. In field scale (actual) operation, flow, temperature and ammonia/NOx non-uniformities exist. In the highly controlled laboratory environment these non-uniformities do not exist; therefore, the lab results must be scaled-up to reflect expected field performance. The scale-up factors limit achievable NOX reduction performance in operating SCR systems. The performance threshold value is based on design values for the scale-up factors. The actual threshold may be lower if actual scale-up is less severe, or higher if more severe. Element ID Time On-Line (Hours) Fresh Reference # 2388-1026-0430 0 NOx Removal Efficiency, % at 5 ppmvdc NH3 Slip 95.5 April 2019 Audit # 2388-1026-0462 845 94.0 Threshold (based on design scale-up factors) CORMETECH Confidential www.cormetech.com 85.9 | 11 5000 International Drive Durham, North Carolina 27712 USAPage 84 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 84 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report The figure below shows the trend in catalyst performance. This audit of the GenConn Devon Power Unit 18 SCR catalyst shows a measurable decrease in catalytic potential of the SCR catalyst, as measured by lab-scale testing. Based on the results of this audit, the SCR catalyst installed for GenConn Devon Power Unit 18 is above the performance threshold and is projected to continue to meet the field performance requirements of 85.9% NOX reduction at 5 ppmvdc ammonia slip for at least an additional 4,000 operating hours from the date this sample was removed. This prediction assumes that catalyst deactivation will continue at the same rate as measured over the operating hours to date. If this rate of deactivation changes, the prediction of remaining catalyst life will change accordingly; therefore, Cormetech recommends performing regular field performance and laboratory catalyst audits. CORMETECH Confidential www.cormetech.com | 12 5000 International Drive Durham, North Carolina 27712 USAPage 85 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 85 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report FIELD DATA COMMENTARY A review of field data has three primary purposes. First, the field data can show if any operating parameters are significantly different than the original design of the unit. Second, the field data can show if actual plant performance requirements are more severe than the design. If significant differences are evident in operating parameters or performance requirements, their effect on the performance threshold can be determined. Third, the field data can be used to examine if any factors that adversely impact scale-up are present. Typically the factors that adversely impact scale-up are as follows: • • • • Plugged/ poorly performing Ammonia Injection System resulting in poor mixing of the NH3 prior to the catalyst. Flue gas flow velocity maldistribution. Flue gas flow bypass around the catalyst. Plugged catalyst. Below is a table that compares the field data provided by GenConn Devon Power Unit 18 SCR against the design criteria for the installed SCR catalyst: Parameter Flue Gas Temperature (°F) Flue Gas Flow Rate (lb/hr) Inlet NOx (ppmvd @ 15% O2) Outlet NOx (ppmvd @ 15% O2) NOx Reduction Efficiency (%) NH3 Slip (ppmvd @ 15% O2) NH3 Flow Rate (lb/hr) NH3 Supply Concentration (wgt %) Flue Gas O2 Conc. (% vol dry) Catalyst Pressure Drop (in. wg.) Design Value 828 1,088,460 42 5.9 85.9 5 (end of life) 180 (end of life) 19 14.4 5.1 Field Value (oil) 831 N/A 42 (estimated) 4.6 89 2.59 147 19 8.9 5 Field Value (gas) 831 N/A 25 (estimated) 1.9 92.4 2.59 106 19 11.3 5 Permit Limit Outlet NOx = 5.9 ppmvd @ 15% O2 (ULSK), 2.5 ppm vd @15% O2 (Gas) Ammonia Slip = 5 ppm Based on the provided operational data, GenConn Devon Power Unit 18 is operating well in the field and meeting permit limits. The measured ammonia slip and flow rate are lower than expected given the other parameters and lab measured activity of the catalyst, indicating good performance. In both oil fired and gas fired conditions, the outlet NOx is being driven well below the permit limit. This increases the NOx reduction efficiency resulting in a higher level of performance than the design of the catalyst. As the catalyst deactivates over time the outlet NO x will need to be maintained closer to the permit requirements to maintain ammonia slip within permit requirements. CORMETECH Confidential www.cormetech.com | 13 5000 International Drive Durham, North Carolina 27712 USAPage 86 of 178
GenConn Energy LLC Docket No. 26-06-02 LFE-010 Attachment 1 Page 86 of 178 NRG GenConn Devon Power Unit 18 July 17, 2019 SCR Catalyst Performance Test Report RECOMMENDATIONS Regular laboratory catalyst testing is recommended to refine the accuracy of the remaining catalyst life prediction. The next audit should occur after an additional 1000 hours of operation or three years, whichever is first, from the time the sample for this audit was removed. Continued review of field test data to accurately confirm actual performance requirements, operating conditions, and system scale-up factors, and thereby the appropriate laboratory scale performance threshold is recommended. CORMETECH Confidential www.cormetech.com | 14 5000 International Drive Durham, North Carolina 27712 USA
Text of LFE-011 GenConn.pdf
Extracted from the file · 1 page · 2,796 characters
Text of LFE-011 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
Text of LFE-012 GenConn.pdf
Extracted from the file · 1 page · 982 characters
Text of LFE-012 Attachment 1 REDACTED.pdf
Extracted from the file · 1 page · 2,492 characters
Text of LFE-014 GenConn.pdf
Extracted from the file · 1 page · 351 characters
Text of LFE-014 Attachment 1 (GenConn- CP2 REVISED V2).pdf
Extracted from the file · 8 pages · 12,688 characters
Text of LFE-015 GenConn.pdf
Extracted from the file · 1 page · 1,318 characters
Text of LFE-009 Attachment 1.xlsx
Sheet names, column headings and text cells; numbers left out
As listed on the current system
LFEs Filed (Avangrid) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14, 15 Date Filed: 10/19/2026