Interrogatory responses
Answers to questions 19 thru 32
Files20
CAE-020 Attachment 1.xlsx
Excel · 1.6 MBText searchable
Download CAE-020 Attachment 1.xlsxRead the text of CAE-020 Attachment 1.xlsx
CAE-027 Attachment 2.pdf
PDF · 1.2 MB · 7 pagesText searchable
Download CAE-027 Attachment 2.pdfRead the text of CAE-027 Attachment 2.pdf
CAE-032 Attachment 1.pdf
PDF · 483 KB · 35 pagesText searchable
Download CAE-032 Attachment 1.pdfRead the text of CAE-032 Attachment 1.pdf
CAE-032 Attachment 2.pdf
PDF · 1.1 MB · 36 pagesText searchable
Download CAE-032 Attachment 2.pdfRead the text of CAE-032 Attachment 2.pdf
CAE-020 Attachment 1.pdf
PDF · 5.6 MB · 75 pagesText searchable
Download CAE-020 Attachment 1.pdfRead the text of CAE-020 Attachment 1.pdf
CAE-027 Attachment 1.pdf
PDF · 18 MB · 245 pagesText searchable
Download CAE-027 Attachment 1.pdfRead the text of CAE-027 Attachment 1.pdf
Text of CAE-021.pdf
Extracted from the file · 1 page · 567 characters
Text of CAE-022.pdf
Extracted from the file · 3 pages · 6,575 characters
Text of CAE-023.pdf
Extracted from the file · 1 page · 757 characters
Text of CAE-024.pdf
Extracted from the file · 1 page · 2,191 characters
Text of CAE-025.pdf
Extracted from the file · 1 page · 1,125 characters
Text of CAE-026.pdf
Extracted from the file · 1 page · 2,757 characters
Text of CAE-027.pdf
Extracted from the file · 1 page · 1,054 characters
Text of CAE-027 Attachment 2.pdf
Extracted from the file · 7 pages · 23,401 characters
Text of CAE-028.pdf
Extracted from the file · 1 page · 714 characters
Text of CAE-029.pdf
Extracted from the file · 1 page · 1,362 characters
Text of CAE-030.pdf
Extracted from the file · 1 page · 1,728 characters
Text of CAE-031.pdf
Extracted from the file · 1 page · 1,654 characters
Text of CAE-032.pdf
Extracted from the file · 1 page · 1,689 characters
Text of CAE-032 Attachment 1.pdf
Extracted from the file · 35 pages · 69,136 characters
Text of CAE-032 Attachment 2.pdf
Extracted from the file · 36 pages · 33,759 characters
Text of CAE-020 Attachment 1.pdf
Extracted from the file · 75 pages · 742,810 characters
Page 20 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 20 of 245 procurement-driven viability, with OEM pricing reflecting backlog risk, inflation, and supply-chain exposure. 8 Key estimate risks are primarily associated with craft labor availability and labor attraction and retention costs, particularly given sustained construction activity across the western United States. Tight labor market conditions may place upward pressure on installed costs and execution efficiency for generation construction. In addition, as discussed above the current market demand for CTGs remains exceptionally high, resulting in significant pricing volatility. Recent market pricing indicates that CTG costs have increased materially relative to earlier budgetary inputs. This observed increase highlights the rapidly changing market conditions for CTGs. Tariff and sales/use tax considerations were applied appropriately to major equipment packages, including CTGs, balance‑of‑plant equipment, structural steel, and electrical materials in alignment with Nevada’s tax treatment of construction materials and equipment, and these tax elements were incorporated directly into the capital cost basis as documented in the Technical Appendix GEN-3 study’s sales tax calculations. Owner’s indirect costs were developed using NV Energy precedents and include project management, engineering, permitting, environmental studies, construction oversight, geotechnical work, security systems, interconnection requirements, and project closeout activities, all of which materially influence total project cost and schedule expectations. These indirect costs reflect typical requirements for complex generation additions and ensure that non‑EPC owner responsibilities are fully captured in the total capital requirement. NV Energy escalated project costs estimates to the year of installation using a 2.5 percent yearly inflation rate based on the assumptions in the Financial Plan. Jared Anderson, US Gas-Fired Turbine Wait Times as Much as Seven Years; Costs Up Sharply, May 20, 2025, available at https://www.spglobal.com/energy/en/news-research/latest-news/electric-power/052025-us-gas-firedturbine-wait-times-as-much-as-seven-years-costs-up-sharply; SustainablePowerNews, Gas Turbine Backlog Crisis: 2026 Orders Double as Buyers Face 5-Year Wait Times, March 26, 2026, available at https://sustainablepowernews.com/gas-turbine-backlog-crisis-orders-double-as-buyers-face-5-year-wait-times/; ManufacturingToday, Gas turbine costs surge 195% as demand outpaces supply, Apr. 3, 2026, available at https://www.manufacturingtodayindia.com/gas-turbine-costs-surge-195, Kevin Clark, Gas turbine prices climb 195% as supply crunch reshapes power development, Apr. 1, 2026, available at https://www.powereng.com/gas/turbines/gas-turbine-prices-climb-195-as-supply-crunch-reshapes-power-development/. 8 16 Page 20 of 245Page 21 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 21 of 245 Evaluated Technologies: Aeroderivative Combustion Turbines Aeroderivative CTGs were evaluated as smaller, modular thermal resources capable of providing flexible capacity support. These units were modeled as available beginning in 2030 and were typically represented in 200 MW aggregate blocks. Aeroderivative CTGs offer relatively short lead times, rapid start capability, and reduced execution risk compared to larger frame-based units, making them suitable for meeting near-term capacity needs and addressing uncertainty in load growth and resource timing. Additionally, simple-cycle aeroderivatives generally have low water requirements because, unlike combined-cycle units, simple-cycle operations do not require largescale condenser cooling. Water use is generally limited to optional performance enhancement. Frame Combustion Turbines Frame CTGs were evaluated as larger standalone simple-cycle thermal resources capable of providing significant incremental capacity through fewer, higher output units. These units offer higher nameplate capacity per installation relative to aeroderivative technologies and can be effective for meeting bulk capacity needs once constructed. Simple-cycle frame CTGs generally have low water requirements because, unlike combined-cycle units, they do not require large scale condenser cooling and rely primarily on ambient air, with water use generally limited to optional performance enhancement. Frame CTGs have longer procurement, manufacturing, and construction lead times than aeroderivative CTGs. During development of the IRP, information emerged indicating that, due to the increased demand for frame combustion turbines, these units are likely no longer available in time to achieve a 2031 commercial operation date. This development was a factor in the selection of the Preferred Plan, which includes aeroderivative CTGs in-service in 2031 rather than Frame CTGs, as described in the Economic Analysis Section of the narrative. Small Frame 2x1 Combined Cycle The small frame 2x1 combined-cycle configuration was evaluated as a thermal resource. This configuration consists of two frame F class CTGs paired with a single steam turbine nominally rated at roughly 760 MW. By recovering waste heat from CTGs through a steam cycle, combinedcycle resources offer significantly higher thermal efficiency than simple-cycle units. If configured with air-cooled condensers rather than wet cooling systems like a cooling tower, small frame 2x1 combined-cycle facilities can reduce water use by about 95% relative to wet-cooled designs. 9 U.S. Energy Information Administration, Some U.S. electricity generating plants use dry cooling, Aug. 29, 2018, available at https://www.eia.gov/todayinenergy/detail.php?id=36773. 9 17 Page 21 of 245Page 22 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 22 of 245 Large Frame 2x1 Combined Cycle Large frame 2x1 combined-cycle resources were evaluated as a thermal resource. These facilities consist of two large frame H or J class CTGs paired with a single steam turbine and represent the highest capacity thermal resources evaluated in the IRP. These facilities provide the highest efficiency and output among the thermal technologies evaluated and are well suited for sustained operation over extended periods and are nominally rated at roughly 1,250 MW. If configured with air-cooled condensers rather than wet cooling systems like a cooling tower, large frame 2x1 combined-cycle facilities can reduce water use by about 95% relative to wet-cooled designs.9 a. Fort Churchill Additions 1 Project Project Overview The Fort Churchill Additions 1 Project which is planned to be commercially operational in 2030 is made up of eight ~53.9 MW aeroderivative simple-cycle generating units, designed for peaking service in Sierra’s service territory. The aeroderivative generating units for the Fort Churchill Aeroderivative Additions Project are highly efficient, state-of the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not certain that these units will meet the Greenhouse Gas Emissions Standards (“GHG Emissions Standards”) carbon dioxide (“CO2”) emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. Each aeroderivative gas turbine can reliably produce approximately 50 MW within 5 minutes. The unit can also balance renewable resources by load-following at 50 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply The Fort Churchill Additions 1 Project is expected to rely on natural gas transportation service. As explained in [Title], Section C – Fuel Supply, Part 1 – Current Physical Gas Supply and Proposed Pipeline Expansion, the Companies requested proposals from three gas pipeline companies. After evaluating the proposals, the Companies selected the proposal provided by Great Basin Gas Transmission Company. The expansion provides sufficient capacity to supply the Forth Churchill Additions 1, 2 and 3 Projects. In addition, the expansion proposal provides sufficient pressure to support LM 6000 units. 18 Page 22 of 245Page 23 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 23 of 245 Project Costs The estimated cost of the Fort Churchill Additions 1 Project is approximately $2.007 billion (2030$) (without AFUDC). Table GEN-2 shows the construction costs by year, and Table GEN3 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Project and the Valmy Simple-Cycle Plant, and believes that the costs to construct the Fort Churchill aeroderivative simple-cycle additions project are reasonable. Sierra has placed the order on the CTGs and will be required to make down payments prior to Commission approval. TABLE GEN-2 FORT CHURCHILL ADDITIONS 1 PROJECT ESTIMATED ESCALATED ANNUAL CONSTRUCTION COSTS (EXCLUDING AFUDC) In thousands Year Amount 2026 $197,322 2027 $347,082 2028 $247,807 2029 $786,705 2030 $427,665 Total (2030$) $2,006,583 19 Page 23 of 245Page 24 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 24 of 245 REDACTED PUBLIC VERSION TABLE GEN-3 FORT CHURCHILL ADDITIONS 1 PROJECT ESTIMATED ESCALATED CONSTRUCTION COSTS BY MAJOR CATEGORY (EXCLUDING AFUDC) (REDACTED) To preserve the 2030 in-service date, Sierra committed million on the Fort Churchill Additions 1 Project to secure long-lead equipment such as the CTGs, generator step-up transformers, and high voltage circuit breakers. The company intends to limit other expenditures until the Commission approves a resource plan which includes the project. Project Schedule Table GEN-4 shows the preliminary project schedule for the Fort Churchill Additions 1 Project. 20 Page 24 of 245Page 25 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 25 of 245 21 Page 25 of 245Page 26 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 26 of 245 The aeroderivative generating units for the Fort Churchill Additions 2 Project are highly efficient, state-of the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not certain that these units will meet the GHG Emissions Standards CO2 emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. The aeroderivative gas turbine can reliably produce approximately 50 MW within 5 minutes. The unit can also balance renewable resources by load-following at 50 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply See the discussion of the Fort Churchill natural gas expansion above. Project Costs The total cost of the Fort Churchill Additions 2 Plant is approximately $2.048 billion (2031$) (without AFUDC). Table GEN-5 shows the construction costs by year, and Table GEN-6 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Plant and the Valmy Simple-Cycle Plant project, and believes that the costs to construct the Fort Churchill Additions 2 Project reasonable. Sierra has not yet made commitments for the turbines and generators but will be required to make down payments prior to Commission Approval. 22 Page 26 of 245Page 27 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 27 of 245 REDACTED PUBLIC VERSION TABLE GEN-5 FORT CHURCHILL ADDITIONS 2 PROJECT ESTIMATED ESCALATED ANNUAL CONSTRUCTION COSTS EXCLUDING AFUDC In thousands Year Amount 2026 $ 154,101 2027 $ 44,194 2028 $ 354,890 2029 $ 253,383 2030 $ 804,409 2031 $ 437,286 Total (2031$) $2,048,263 TABLE GEN-6 FORT CHURCHILL ADDITIONS 2 PROJECT ESTIMATED ESCALATED CONSTRUCTION COSTS BY MAJOR CATEGORY (EXCLUDING AFUDC) (REDACTED) 23 Page 27 of 245Page 28 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 28 of 245 24 Page 28 of 245Page 29 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 29 of 245 c. Fort Churchill Additions 3 Project Project Overview The Fort Churchill Additions 3 Project is planned to be commercially operational in 2032 and is made up of two ~200 MW simple-cycle frame generating units, designed for peaking service in Sierra’s service territory. The simple-cycle generating unit for the Fort Churchill Additions 3 Project is a highly efficient, state-of-the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not expected that these units will meet the GHG Emissions Standards CO2 emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. The simple-cycle frame gas turbine can reliably produce approximately 200 MW within 10 minutes and can reach full load in under 11 minutes. The unit can also balance renewable resources by load-following at 40 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply See the discussion of the Fort Churchill gas expansion above. Because frame units operate with lower gas pressure, the Companies will regulate pressure down to acceptable operating parameters through on-site equipment. Project Costs The total cost of the Fort Churchill Additions 3 Project is approximately $978 million (2032$) (without AFUDC). Table GEN-8 shows the construction costs by year, and Table GEN-9 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Project and the Valmy Simple-Cycle Plant, and believes that the costs to construct a Fort Churchill Additions 3 Project are reasonable. Sierra has not yet made commitments for the turbines and generators but will be required to make down payments prior to Commission approval. 25 Page 29 of 245
As listed on the current system
Question(s) Answered 19 thru 32 (CL&P dba Eversource Energy) Date Filed: 10/28/2026