Interrogatory responses
Answers to questions 19 thru 32
Files20
CAE-020 Attachment 1.xlsx
Excel · 1.6 MBText searchable
Download CAE-020 Attachment 1.xlsxRead the text of CAE-020 Attachment 1.xlsx
CAE-027 Attachment 2.pdf
PDF · 1.2 MB · 7 pagesText searchable
Download CAE-027 Attachment 2.pdfRead the text of CAE-027 Attachment 2.pdf
CAE-032 Attachment 1.pdf
PDF · 483 KB · 35 pagesText searchable
Download CAE-032 Attachment 1.pdfRead the text of CAE-032 Attachment 1.pdf
CAE-032 Attachment 2.pdf
PDF · 1.1 MB · 36 pagesText searchable
Download CAE-032 Attachment 2.pdfRead the text of CAE-032 Attachment 2.pdf
CAE-020 Attachment 1.pdf
PDF · 5.6 MB · 75 pagesText searchable
Download CAE-020 Attachment 1.pdfRead the text of CAE-020 Attachment 1.pdf
CAE-027 Attachment 1.pdf
PDF · 18 MB · 245 pagesText searchable
Download CAE-027 Attachment 1.pdfRead the text of CAE-027 Attachment 1.pdf
Text of CAE-021.pdf
Extracted from the file · 1 page · 567 characters
Text of CAE-022.pdf
Extracted from the file · 3 pages · 6,575 characters
Text of CAE-023.pdf
Extracted from the file · 1 page · 757 characters
Text of CAE-024.pdf
Extracted from the file · 1 page · 2,191 characters
Text of CAE-025.pdf
Extracted from the file · 1 page · 1,125 characters
Text of CAE-026.pdf
Extracted from the file · 1 page · 2,757 characters
Text of CAE-027.pdf
Extracted from the file · 1 page · 1,054 characters
Text of CAE-027 Attachment 2.pdf
Extracted from the file · 7 pages · 23,401 characters
Text of CAE-028.pdf
Extracted from the file · 1 page · 714 characters
Text of CAE-029.pdf
Extracted from the file · 1 page · 1,362 characters
Text of CAE-030.pdf
Extracted from the file · 1 page · 1,728 characters
Text of CAE-031.pdf
Extracted from the file · 1 page · 1,654 characters
Text of CAE-032.pdf
Extracted from the file · 1 page · 1,689 characters
Text of CAE-032 Attachment 1.pdf
Extracted from the file · 35 pages · 69,136 characters
Text of CAE-032 Attachment 2.pdf
Extracted from the file · 36 pages · 33,759 characters
Text of CAE-020 Attachment 1.pdf
Extracted from the file · 75 pages · 742,810 characters
Page 22 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 22 of 245 Large Frame 2x1 Combined Cycle Large frame 2x1 combined-cycle resources were evaluated as a thermal resource. These facilities consist of two large frame H or J class CTGs paired with a single steam turbine and represent the highest capacity thermal resources evaluated in the IRP. These facilities provide the highest efficiency and output among the thermal technologies evaluated and are well suited for sustained operation over extended periods and are nominally rated at roughly 1,250 MW. If configured with air-cooled condensers rather than wet cooling systems like a cooling tower, large frame 2x1 combined-cycle facilities can reduce water use by about 95% relative to wet-cooled designs.9 a. Fort Churchill Additions 1 Project Project Overview The Fort Churchill Additions 1 Project which is planned to be commercially operational in 2030 is made up of eight ~53.9 MW aeroderivative simple-cycle generating units, designed for peaking service in Sierra’s service territory. The aeroderivative generating units for the Fort Churchill Aeroderivative Additions Project are highly efficient, state-of the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not certain that these units will meet the Greenhouse Gas Emissions Standards (“GHG Emissions Standards”) carbon dioxide (“CO2”) emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. Each aeroderivative gas turbine can reliably produce approximately 50 MW within 5 minutes. The unit can also balance renewable resources by load-following at 50 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply The Fort Churchill Additions 1 Project is expected to rely on natural gas transportation service. As explained in [Title], Section C – Fuel Supply, Part 1 – Current Physical Gas Supply and Proposed Pipeline Expansion, the Companies requested proposals from three gas pipeline companies. After evaluating the proposals, the Companies selected the proposal provided by Great Basin Gas Transmission Company. The expansion provides sufficient capacity to supply the Forth Churchill Additions 1, 2 and 3 Projects. In addition, the expansion proposal provides sufficient pressure to support LM 6000 units. 18 Page 22 of 245Page 23 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 23 of 245 Project Costs The estimated cost of the Fort Churchill Additions 1 Project is approximately $2.007 billion (2030$) (without AFUDC). Table GEN-2 shows the construction costs by year, and Table GEN3 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Project and the Valmy Simple-Cycle Plant, and believes that the costs to construct the Fort Churchill aeroderivative simple-cycle additions project are reasonable. Sierra has placed the order on the CTGs and will be required to make down payments prior to Commission approval. TABLE GEN-2 FORT CHURCHILL ADDITIONS 1 PROJECT ESTIMATED ESCALATED ANNUAL CONSTRUCTION COSTS (EXCLUDING AFUDC) In thousands Year Amount 2026 $197,322 2027 $347,082 2028 $247,807 2029 $786,705 2030 $427,665 Total (2030$) $2,006,583 19 Page 23 of 245Page 24 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 24 of 245 REDACTED PUBLIC VERSION TABLE GEN-3 FORT CHURCHILL ADDITIONS 1 PROJECT ESTIMATED ESCALATED CONSTRUCTION COSTS BY MAJOR CATEGORY (EXCLUDING AFUDC) (REDACTED) To preserve the 2030 in-service date, Sierra committed million on the Fort Churchill Additions 1 Project to secure long-lead equipment such as the CTGs, generator step-up transformers, and high voltage circuit breakers. The company intends to limit other expenditures until the Commission approves a resource plan which includes the project. Project Schedule Table GEN-4 shows the preliminary project schedule for the Fort Churchill Additions 1 Project. 20 Page 24 of 245Page 25 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 25 of 245 21 Page 25 of 245Page 26 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 26 of 245 The aeroderivative generating units for the Fort Churchill Additions 2 Project are highly efficient, state-of the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not certain that these units will meet the GHG Emissions Standards CO2 emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. The aeroderivative gas turbine can reliably produce approximately 50 MW within 5 minutes. The unit can also balance renewable resources by load-following at 50 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply See the discussion of the Fort Churchill natural gas expansion above. Project Costs The total cost of the Fort Churchill Additions 2 Plant is approximately $2.048 billion (2031$) (without AFUDC). Table GEN-5 shows the construction costs by year, and Table GEN-6 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Plant and the Valmy Simple-Cycle Plant project, and believes that the costs to construct the Fort Churchill Additions 2 Project reasonable. Sierra has not yet made commitments for the turbines and generators but will be required to make down payments prior to Commission Approval. 22 Page 26 of 245Page 27 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 27 of 245 REDACTED PUBLIC VERSION TABLE GEN-5 FORT CHURCHILL ADDITIONS 2 PROJECT ESTIMATED ESCALATED ANNUAL CONSTRUCTION COSTS EXCLUDING AFUDC In thousands Year Amount 2026 $ 154,101 2027 $ 44,194 2028 $ 354,890 2029 $ 253,383 2030 $ 804,409 2031 $ 437,286 Total (2031$) $2,048,263 TABLE GEN-6 FORT CHURCHILL ADDITIONS 2 PROJECT ESTIMATED ESCALATED CONSTRUCTION COSTS BY MAJOR CATEGORY (EXCLUDING AFUDC) (REDACTED) 23 Page 27 of 245Page 28 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 28 of 245 24 Page 28 of 245Page 29 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 29 of 245 c. Fort Churchill Additions 3 Project Project Overview The Fort Churchill Additions 3 Project is planned to be commercially operational in 2032 and is made up of two ~200 MW simple-cycle frame generating units, designed for peaking service in Sierra’s service territory. The simple-cycle generating unit for the Fort Churchill Additions 3 Project is a highly efficient, state-of-the-art, combustion turbines. To reduce emissions, a combination of dry low-NOx combustion systems, selective catalytic reduction and carbon monoxide catalyst will be incorporated into the design. It is not expected that these units will meet the GHG Emissions Standards CO2 emissions limit for intermediate-load operation (capacity factor between 20 and 40 percent) under all operating scenarios and are, therefore, were conservatively considered as low-utilization resources (capacity factor of up to 20 percent) for planning purposes. Section 5 - Environmental Regulation Updates - provides more information on the GHG Emissions Standards status. The simple-cycle frame gas turbine can reliably produce approximately 200 MW within 10 minutes and can reach full load in under 11 minutes. The unit can also balance renewable resources by load-following at 40 MW/min ramp rates while maintaining emissions compliance. Natural Gas Supply See the discussion of the Fort Churchill gas expansion above. Because frame units operate with lower gas pressure, the Companies will regulate pressure down to acceptable operating parameters through on-site equipment. Project Costs The total cost of the Fort Churchill Additions 3 Project is approximately $978 million (2032$) (without AFUDC). Table GEN-8 shows the construction costs by year, and Table GEN-9 shows the line-item detail of the project cost. There is always a risk that material, equipment, and labor costs can increase or decrease between the time of the cost estimates and the time of contract award and procurement. Increases in construction costs in the past few years have been dramatic; however, Sierra has developed estimated costs for major contracts, based on costs seen for the Silverhawk Peaker Project and the Valmy Simple-Cycle Plant, and believes that the costs to construct a Fort Churchill Additions 3 Project are reasonable. Sierra has not yet made commitments for the turbines and generators but will be required to make down payments prior to Commission approval. 25 Page 29 of 245Page 30 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 30 of 245 REDACTED PUBLIC VERSION TABLE GEN-8 FORT CHURCHILL ADDITIONS 3 PROJECT ESTIMATED ESCALATED ANNUAL CONSTRUCTION COSTS EXCLUDING AFUDC In thousands Year Amount 2026 $101,831 2027 $41,304 2028 $87,724 2029 $175,275 2030 $260,587 2031 $205,110 2032 $106,398 Total (2032$) $978,229 TABLE GEN-9 FORT CHURCHILL ADDITIONS 3 PROJECT ESTIMATED ESCALATED CONSTRUCTION COSTS BY MAJOR CATEGORY (EXCLUDING AFUDC) (REDACTED) 26 Page 30 of 245Page 31 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 31 of 245 27 Page 31 of 245
As listed on the current system
Question(s) Answered 19 thru 32 (CL&P dba Eversource Energy) Date Filed: 10/28/2026