Interrogatory responses
Answers to questions 19 thru 32
Files20
CAE-020 Attachment 1.xlsx
Excel · 1.6 MBText searchable
Download CAE-020 Attachment 1.xlsxRead the text of CAE-020 Attachment 1.xlsx
CAE-027 Attachment 2.pdf
PDF · 1.2 MB · 7 pagesText searchable
Download CAE-027 Attachment 2.pdfRead the text of CAE-027 Attachment 2.pdf
CAE-032 Attachment 1.pdf
PDF · 483 KB · 35 pagesText searchable
Download CAE-032 Attachment 1.pdfRead the text of CAE-032 Attachment 1.pdf
CAE-032 Attachment 2.pdf
PDF · 1.1 MB · 36 pagesText searchable
Download CAE-032 Attachment 2.pdfRead the text of CAE-032 Attachment 2.pdf
CAE-020 Attachment 1.pdf
PDF · 5.6 MB · 75 pagesText searchable
Download CAE-020 Attachment 1.pdfRead the text of CAE-020 Attachment 1.pdf
CAE-027 Attachment 1.pdf
PDF · 18 MB · 245 pagesText searchable
Download CAE-027 Attachment 1.pdfRead the text of CAE-027 Attachment 1.pdf
Text of CAE-021.pdf
Extracted from the file · 1 page · 567 characters
Text of CAE-022.pdf
Extracted from the file · 3 pages · 6,575 characters
Text of CAE-023.pdf
Extracted from the file · 1 page · 757 characters
Text of CAE-024.pdf
Extracted from the file · 1 page · 2,191 characters
Text of CAE-025.pdf
Extracted from the file · 1 page · 1,125 characters
Text of CAE-026.pdf
Extracted from the file · 1 page · 2,757 characters
Text of CAE-027.pdf
Extracted from the file · 1 page · 1,054 characters
Text of CAE-027 Attachment 2.pdf
Extracted from the file · 7 pages · 23,401 characters
Text of CAE-028.pdf
Extracted from the file · 1 page · 714 characters
Text of CAE-029.pdf
Extracted from the file · 1 page · 1,362 characters
Text of CAE-030.pdf
Extracted from the file · 1 page · 1,728 characters
Text of CAE-031.pdf
Extracted from the file · 1 page · 1,654 characters
Text of CAE-032.pdf
Extracted from the file · 1 page · 1,689 characters
Text of CAE-032 Attachment 1.pdf
Extracted from the file · 35 pages · 69,136 characters
Text of CAE-032 Attachment 2.pdf
Extracted from the file · 36 pages · 33,759 characters
Text of CAE-020 Attachment 1.pdf
Extracted from the file · 75 pages · 742,810 characters
Page 33 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 33 of 245 REDACTED PUBLIC VERSION The estimated prelimimuy development costs for these early-stage activities are shown in Tables GEN-11 and GEN-12 for the simple-cycle 2034 placeholder project. TABLE GEN-11 EARLY INVESTMENT FOR FUTURE 2034 THERMAL PROJECT ESTIMATED ESCALATED PRELIMINARY DEVELOPMENT COSTS EXCLUDING AFUDC In thousands Year Amount 2027 $12,025 2028 $1,016 Total (2028$) $13,041 TABLE GEN-12 EARLY INVESTMENT FOR FUTURE 2034 THERMAL PROJECT ESTIMATED ESCALATED PRELIMINARY DEVELOPMENT COSTS (EXCLUDING AFUDC) (REDACTED) Table GEN-13 shows a prelimina1y development schedule for early investment act1v1hes associated with the future placeholder 2034 the1mal projects. This schedule reflects the anticipated sequence of activities to advance preliminaiy engineering, obtain contractor input, and develop a more detailed basis for project cost and execution planning. The schedule is not strictly sequential, 29 Page 33 of 245Page 34 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 34 of 245 30 Page 34 of 245Page 35 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 35 of 245 Regional Haze Rule Since March 2024, 10 Sierra has worked with the NDEP to evaluate the Regional Haze Rule for the Second Decadal (Second Implementation) Planning Period (2018-2028) requirements applicable to Valmy Units 1 and 2 (following natural gas conversion) and Tracy 4/5. For Valmy Units 1 and 2, additional NOx reductions while firing natural gas were determined to be cost-effective through 2049, to a control level equivalent to SNCR performance. Sierra and the NDEP also preserved flexibility to meet these limits using either FGR or SCR. This approach also supports compliance with other federal requirements that may take effect, including the federal Good Neighbor Plan (see update below). For Tracy 4/5, SCR was determined to be cost-effective through 2049. The NDEP has worked with the EPA and federal land management agencies to revise Nevada’s Regional Haze SIP. This work included drafting state regulations to make Regional Haze requirements for Valmy Units 1 and 2 and Tracy 4/5 legally enforceable and conducting public outreach. 11 The state regulation sets the NOx emission levels, identifies control technologies, and establishes a compliance deadline. Under the state regulation, NOx controls must be installed within 36 months of EPA approval of Nevada’s Regional Haze SIP for these units. The NDEP submitted the SIP revision for North Valmy Units 1 and 2 and Tracy 4/5 to the EPA in May 2025 (“2025 Regional Haze SIP Revision”). As part of a separate July 2024 consent decree between the EPA and the Sierra Club, National Parks Conservation Association, and Environmental Integrity Project required the EPA to approve or deny Nevada’s Regional Haze SIP by December 15, 2025. 12 On October 23, 2025, the EPA published a proposed action and opened a 30-day public comment period that closed on November 24, 2025. The EPA issued its final action on February 6, 2026; this timing complied with the consent decree, with additional time allowed due to the government shutdown. In the final action, the EPA approved portions of the 2022 Nevada Regional Haze SIP, including the July 2023 withdrawal of proposed retirement determinations for Tracy 4/5 and Valmy Units 1 and 2, and portions of the 2025 Nevada Regional Haze SIP Revision. 13 The EPA did not act on the revised reasonable progress determinations or the proposed NOx emission controls for Tracy 4/5 and Valmy Units 1 and 2 included in the 2025 Regional Haze SIP Revision, because those revisions were submitted after the July 2024 consent decree. 10 Docket No. 23-08015, April 9, 2024, Order approved Sierra’s requests to proceed with the Valmy Units 1 and 2 coal-to-gas conversion and Tracy 4/5 projects. 11 NAC Chapter 445B, as amended by regulation adopted by the Nevada State Environmental Commission in 2024, establishing source-specific Regional Haze requirements for NV Energy’s North Valmy Generating Station (Units 1 and 2) and Tracy Generating Station (Units 4 and 5). 12 Sierra Club, et al. v. U.S. Environmental Protection Agency, No. 1:23-cv-01744-JDB (D.D.C.), Consent Decree entered July 12, 2024, establishing deadlines for EPA action on Regional Haze State Implementation Plans, including plans submitted by Nevada. 13 90 Fed. Reg. 48,481 (Oct. 23, 2025) (proposed rule) and 91 Fed. Reg. 5321 (Feb. 6, 2026), the EPA refers to the Nevada SIP filings as the “2022 Nevada Regional Haze Plan” and the “2025 SIP Supplement.” 31 Page 35 of 245Page 36 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 36 of 245 The EPA is expected to evaluate the proposed NOx controls for Valmy Units 1 and 2 and Tracy 4/5 included in the 2025 Regional Haze SIP Revision through a separate action. The EPA has not provided a schedule for that evaluation; however, for planning purposes, Sierra anticipates the EPA may act later in 2026. Under the state regulation, NOx controls must be installed within 36 months following EPA approval of the proposed NOx controls for Tracy 4/5 and Valmy Units 1 and 2. Good Neighbor Plan The federal “Good Neighbor Plan” for the 2015 Ozone National Ambient Air Quality Standards (“NAAQS”) became effective on August 4, 2023, and was intended to take effect for 22 states, including Nevada. 14 The rule has been subject to litigation since issuance and is currently stayed in effective states, including Nevada. If it were to take effect, the Good Neighbor Plan would require upwind states to reduce emissions of the ozone precursor NOx from electric generating units (“EGUs”) and certain stationary industrial sources. For EGUs, the program sets statewide ozone-season NOx emissions budgets and allocates emissions allowances to individual EGUs for May–September through a market-based trading program. On January 30, 2026, the EPA proposed Phase 1 of its reconsideration of the federal Good Neighbor Plan. 15 Under this reconsideration, the EPA intends to withdraw its February 12, 2023 disapproval and approve Nevada’s September 28, 2018 Good Neighbor SIP submission. The EPA acknowledges that Nevada applied the four-step interstate transport framework (the “Framework”) and determined that Nevada sources do not contribute more than 1% of the NAAQS to any nonattainment or maintenance receptor. If the EPA’s reconsideration is finalized as proposed, Nevada would not be required to adopt any new permanent, enforceable emission control measures under Nevada’s Good Neighbor SIP. If the federal Good Neighbor Plan were to ultimately take effect and Nevada was included, the program would have affected Valmy Units 1 and 2 while operating on coal. Emission allowances would have been constrained based on NOx emission rates achievable with SCR controls under coal-fired operation. Given uncertainty in the litigation outcome and potential applicability to Nevada, the 2025 Nevada Regional Haze SIP revision and related state regulation incorporated flexibility in the NOx control approach for Valmy. This flexibility allows consideration of SCR (if ultimately needed after conversion to natural gas) to support compliance and provide sufficient ozone-season allowances under the Good Neighbor Plan. No other EGUs would have been required to install NOx controls. Nevada’s annual EGU allowance budget would be set through a “dynamic” budgeting process based on recent operations and associated emissions, further limiting ozone-season NOx emissions. 14 15 88 Fed. Reg. 36,654 (June 5, 2023). 91 Fed. Reg. 4,026 (Jan. 30, 2026). 32 Page 36 of 245Page 37 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 37 of 245 Greenhouse Gas Emissions Standards On May 9, 2024, the EPA published a final rule for federal GHG Emissions Standards for fossil fuel-fired electric generating unit. 16 The GHG Emissions Standards became effective on July 8, 2024. Litigation commenced following publication. However, the GHG Emissions Standards remain in effect as published. On June 17, 2025, the EPA proposed repealing the GHG Emissions Standards in its entirety. 17 The EPA is also proposing, as an alternative, to repeal a narrower set of requirements that includes the emission guidelines for existing fossil fuel-fired steam generating units, the carbon capture and sequestration/storage (“CCS”)-based standards for coal-fired steam generating units undertaking a large modification, and the CCS-based standards for new baseload stationary combustion turbines. On February 27, 2026, the EPA submitted a status report to the U.S. Court of Appeals for the District of Columbia Circuit indicating that the proposed rulemaking process is ongoing and that the agency continues to analyze and gather information from a variety of sources. 18 In that report, the EPA stated it intended to send a draft final rule to the Office of Management and Budget in early spring 2026. The next EPA status report to the court is due on May 29, 2026. The GHG Emissions Standards currently in effect establishes the final best system of emissions reduction (“BSER”) and resulting performance standards for new gas-fired combustion turbines, existing coal-fired steam generating units, and existing oil- and gas-fired steam generating units. The final rule did not establish performance standards for existing gas-fired combustion turbines. For existing oil- or natural gas-fired steam generating units, the GHG Emissions Standards do not require installation of CCS if the unit maintains routine efficient operation and achieves a CO2 emission rate below 1,400 lb. CO2/MWh (if the capacity factor is 45 percent or greater) or below 1,600 lb. CO2/MWh (if the capacity factor is less than 45 percent), beginning January 1, 2030. For new gas units, the final standards use capacity factor thresholds to differentiate between baseload units (capacity factors greater than 40 percent), intermediate-load units (capacity factors between 20 and 40 percent), and low-utilization units (capacity factors of 20 percent or less). Capacity factors for these categories are measured on a 12-month rolling average. • For new baseload units, the BSER is achieved in two phases. Phase 1 requires highly efficient operation, achieving a performance standard of 800 lb. CO2/MWh through 2031. Phase 2 requires CCS at a 90 percent capture rate, or an emissions rate of 100 lb. CO2/MWh, starting in 2032. 16 New Source Performance Standards for Greenhouse Gas Emissions from New, Modified, and Reconstructed Fossil Fuel-Fired Electric Generating Units; Emission Guidelines for Greenhouse Gas Emissions from Existing Fossil FuelFired Electric Generating Units; and Repeal of the Affordable Clean Energy Rule, 89 Fed. Reg. 39,798 (May 9, 2024). 17 90 Fed. Reg. 25,752 (June 17, 2025). 18 U.S. Environmental Protection Agency, Status Report to the U.S. Court of Appeals for the District of Columbia Circuit (Feb. 27, 2026), Case No. 24-1120. 33 Page 37 of 245Page 38 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 38 of 245 • For new intermediate-load units, the BSER is efficient operation resulting in an emissions limitation of 1,170 lb. CO2/MWh, effective upon the start of operation. • For new low-utilization units, the BSER requires the use of clean fuels (i.e., natural gas, Nos. 1 and 2 fuel oil), with a resulting standard of 120–160 lb. CO2/MMBtu, depending on unit-specific characteristics. These GHG Emissions Standards, currently in effect, result in the following considerations for and the Companies fleet: • Valmy Units 1 and 2 (converted to natural gas operation), Fort Churchill units, and Tracy Unit 3 would be regulated as existing gas-fired steam units. These units would be required to maintain routine efficient operation and achieve CO2 emission rates between 1,400 and 1,600 lb. CO2/MWh depending on capacity factor. Valmy Units 1 and 2 operating on natural gas will also meet these CO2 emission rates. • The constructed Silverhawk Peaker Project, approved Valmy Simple-Cycle Plant, and proposed Fort Churchill 1, 2, and 3 additions (simple-cycle units that would likely be operated as low-utilization units (up to a 20 percent capacity factor)) with no CO2 emission rate requirement. If these units were capable of operating as intermediate-load units (20 to 40 percent capacity factor), they would need to meet a CO2 emission rate of 1,170 lb. CO2/MWh on a 12-month rolling average while operating on natural gas. • The remaining existing Companies units are not impacted by the current GHG Emissions Standards. Mercury and Air Toxics Standards On May 7, 2024, the EPA finalized amendments to the Mercury and Air Toxics Standards (“MATS”) to strengthen the National Emission Standards for Hazardous Air Pollutants for coaland oil-fired electric utility steam generating units. 19 The amendments would have applied to Valmy Units 1 and 2 only if they continued operating on coal. Historical emissions test data indicate the units generally would have met the revised limit; however, compliance would have required adding particulate matter (“PM”) continuous emissions monitoring system (“CEMS”) capability and integrating it into existing facility systems. On February 19, 2026, the EPA finalized the repeal of the 2024 amendments. 20 19 20 89 Fed. Reg. 38,508 (May 7, 2024). 91 Fed. Reg. 9,088 (Feb. 24, 2026). 34 Page 38 of 245Page 39 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 39 of 245 With Valmy Units 1 and 2 converted to natural gas, the 2012 MATS rule no longer applies to Nevada Power and Sierra generation operations. 6. Hydrogen Fuel and Carbon Capture The Companies continue to monitor the availability and commercial application of hydrogen as a fuel source for its generating units and carbon capture technologies for the capture and storage of CO2. These technologies are not included in the existing or proposed generating units in this filing. The Companies commissioned a review of the status of these technologies, Carbon Capture & Storage and Hydrogen Fuel Assessment by E3, which is included as Technical Appendix GEN-4 of this filing. At this time, these technologies are not commercially feasible for the Companies’ generating fleet, but the Companies will continue to monitor the commercial feasibility of these technologies for their current and future generating units. 35 Page 39 of 245Page 40 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 40 of 245 B. LONG-TERM POWER PURCHASE AGREEMENTS The Companies meet customer’s energy demand with company-owned and controlled generation, as well as with a combination of long-term power purchase agreements (“PPAs”) and short-term energy transactions. Similarly, the Companies meet the requirements of Nevada’s Renewable Portfolio Standard (“RPS”) through a combination of company-owned generation, Commission-approved long-term PPAs with renewable energy resources, and agreements for purchase of portfolio energy credits (“PCs”). Figure CON-1 lists all of Nevada Power’s renewable and non-renewable long-term PPAs, PC only, and sales agreements. Figure CON-2 lists all of Sierra’s renewable and non-renewable long-term PPAs, PC-only, and sales agreements. 36 Page 40 of 245Page 41 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 41 of 245 FIGURE CON-1 NEVADA POWER’S LONG-TERM POWER PURCHASE AGREEMENTS Contract Name Renewable Purchase Agreements PPAs (Commercial) ACE SearchlightQF APEX Landfill Docket Number Contract Type 09-08020 SolarS Methane 17.5 12/16/14 12.0 03/01/12 12/31/2032 SolarS Hydro 100.0 237.6 12/09/16 10/01/17 12/31/2036 09/30/2067 09-08020 QF Commercial Capacity Operation BESS Termination Date (MW) Date Termination Date 12/31/2034 Copper Mountain 5EWG 15-07003 18-06003 Desert Peak 2QF 02-11040 SolarS Geothermal 250.0 25.0 07/23/21 04/17/07 12/31/2046 12/31/2027 Eagle Shadow MountainEWG 18-06003 SolarS 300.0 FRV SpectrumQF 11-03014 SolarS 30.0 05/10/23 09/23/13 12/31/2048 12/31/2038 Gemini SolarEWG 19-06039 03/25/24 12/31/2049 06-10021 SolarS,X=380 (3.7 hrs) 3 Geothermal 690.0 Jersey ValleyQF 22.5 08/30/11 12/31/2031 McGinness HillsQF 10-02009 Geothermal 96.0 06/20/12 12/31/2032 Moapa (Arrow Canyon) SolarEWG 19-06039 SolarS,X=74 (5 hrs) 3 Mountain ViewEWG 11-03014 SolarS 200.0 20.0 12/08/23 01/05/14 12/31/2048 12/31/2039 Nevada Solar One (NPC)QF 02-11040 06/27/07 12/31/2027 06-10021 SolarT,X Geothermal 46.9 NGP Blue MountainQF 49.5 11/20/09 12/31/2029 RV Apex QF 10-02009 20.0 07/21/12 12/31/2037 Salt WellsQF 07-02015 SolarS Geothermal 23.6 09/18/09 12/31/2029 Silver State EWG 10-03022 52.0 04/25/12 12/31/2037 Spring ValleyEWG 10-02009 SolarF Wind 151.8 08/16/12 12/31/2032 Stillwater Geothermal 1,QF 07-02015 Geothermal 47.2 10/10/09 12/31/20294 07-02015 SolarF 22.0 03/05/12 Switch Station 1 15-07003 S 100.0 08/08/17 12/31/20294 12/31/2037 Switch Station 2 (NPC) EWG 15-11029 SolarS 0.0 10/11/17 12/31/2037 Techren IEWG 16-08026 SolarS 100.0 03/11/19 12/31/2044 Techren IIIQF 17-11004 SolarS 25.0 10/07/20 12/31/2045 Techren V EWG 18-06003 TuscaroraQF 10-03022 SolarS Geothermal 50.0 32.0 12/31/20 01/11/12 12/31/2045 12/31/2032 WM Renewable Energy-LockwoodQF 10-03022 Methane 3.2 2723.8 04/01/12 12/31/2032 Geothermal 2.3 10/30/09 12/31/2028 Solar Solar 13.2 3.0 18.5 12/15/07 04/20/06 12/31/2027 12/31/2026 Boulder Solar IEWG Colorado River Commission-Hoover Stillwater PV 1,QF EWG Solar Total PC Purchase Agreements Sierra Pacific Power QF Nellis I (Solar Star) SunPower (LVVWD) 09-08018 & 0908020 07-01035 04-11033 Total 24-05041 SolarS,X=200(4hrs) Libra Solar 24-05041 SolarS,X=700(4hrs) Total 12/31/2048 200.0 Estimated BESS Termination Termination Date COD Date 12/01/26 12/31/2051 12/31/2046 700.0 12/01/27 PPAs (Pre-Commercial)2 Dry Lake East 12/31/2049 12/31/2052 12/31/2047 900.0 Non-Renewable Purchase Agreements Renewable and Non-Renewable Sales Switch NGR (Switch Station 1) 15-08005 NGR Agreement (Sale of PCs) 100.0 08/08/17 12/31/2037 Switch NGR-NPC (Switch Station 2) 15-11028 NGR Agreement (Sale of PCs) 0.0 10/11/17 12/31/2037 Notes: 1. The geothermal and solar facilities are combined into one PPA. 2. Facilities are either under development or construction (the dates shown are expected dates). 3. Storage reflects current MW based on annual storage capacity test 4. NPC has an option to extend the Stillwater Geothermal/Solar PPA for a period of 3, 4 or 5 years upon the termination date. QF=Qualifying Facility, EWG=Exempt Wholesale Generator, S=Single Axis Tracking, T=Solar Thermal (Tracking), F=Fixed Tilt, X=Storage 37 Page 41 of 245Page 42 of 245
CL&P dba Eversource Energy Docket No. 26-06-0 Set PURA-02 Date Issued October 14, 2026 CAE-027, Attachment 1 Page 42 of 245 FIGURE CON-2 SIERRA’S LONG-TERM POWER PURCHASE AGREEMENTS Contract Name Capacity Commercial Termination BESS Termination (MW) Operation Date Date Date Docket Number Contract Type Battle MountainEWG 18-06003 SolarS,X=24.2MW (4 hrs) 6 101.0 6/23/2021 12/31/2046 Boulder Solar IIEWG 15-11029 50.0 1/27/2017 12/31/2037 Burdette QF 04-08004 SolarS Geothermal 26.0 2/28/2006 12/31/2026 Dodge FlatEWG 18-06003 SolarS,X=50MW (4 hrs) 6 200.0 3/2/2022 12/31/2047 12/31/2037 Fish Springs RanchEWG 18-06003 SolarS,X=24.91MW (4 hrs) 6 Geothermal 100.0 26.5 3/15/2022 2/21/2008 12/31/2047 12/31/2028 12/31/2037 Renewable Energy PPAs (Commercial) QF 06-05040 1,QF QF-Legacy Hydro 0.75 6/23/2016 12/31/2040 - Hydro 0.175 9/19/2011 12/31/2040 12/31/2040 Galena 3 Hooper Kingston1 - Hydro 0.037 9/1/2011 Nevada Solar One (SPPC)QF 02-12039 SolarT 22.1 6/27/2007 12/31/2027 QF 22-03024 25 20.0 4/26/2023 12/31/2048 22-11032 Geothermal Geothermal - Hydro Mill Creek 1 North Valley OWGP Beowawe QF RO Ranch1,2 Techren II 1/10/2025 12/31/2053 0 3/15/2011 12/31/2040 S 15-11029 Solar 79.0 10/11/2017 12/31/2037 EWG 17-02007 S Solar 200.0 10/4/2019 12/31/2044 QF 17-11003 07-01036 07-01036 07-01036 17-11003 11-08010 S 25.0 2.4 2.4 2.5 50.0 11.75 944.6 10/7/2020 5/16/2008 5/15/2009 7/25/2008 12/4/2020 5/25/2012 12/31/2045 6/1/2028 6/1/2029 6/1/2028 12/31/2045 12/31/2037 0.8 9/9/2005 9/1/2026 Switch Station 2 (SPPC) EWG Techren IV TMWA Fleish TMWA Verdi TMWA Washoe Turquoise EWG USG San EmidioQF Solar Hydro Hydro Hydro SolarF Geothermal Total PC Purchase Agreement TMWRF PPAs (Pre-Commercial) 06-04030 Methane 12/31/2031 Termination Estimated COD Date 3 Ormat Western Geothermal Portfolio (OWGP) 5 OWGP PintoQF OWGP Galena 1 QF QF OWGP Desert Peak 2 OWGP Lone Mountain QF QF OWGP Galena 3 OWGP TBD Corsac Generating Station 2 LLC 22-11032 Geothermal 15.0 1/1/2027 12/31/2053 22-11032 Geothermal 15.0 2/1/2027 12/31/2053 22-11032 Geothermal 10.0 2/1/2028 12/31/2053 22-11032 Geothermal 15.0 10/1/2028 12/31/2053 22-11032 22-11032 24-05041 Geothermal Geothermal Geothermal 1/1/2029 TBD 2/1/2030 12/31/2053 12/31/2053 12/31/2045 Total 15.0 30.0 115.0 215.0 Solar & Grid Tied BESS 150 MW (4 hrs) Total 0.0 0.0 7/1/2027 12.0 1/1/2011 Storage Only (Pre-Commercial)3 Dodge Flat Energy Storage Non-Renewable Purchase Agreements Liberty (CalPeco) EBSA7 25-10028 09-12002 & 1007003 Diesel Total Renewable & Non-Renewable Sales Agreements Liberty (CalPeco) NPC-SPPC 09-08018 & 0908020 13-07002 15-11025 15-11025 17-02008 17-11002 12/31/2047 12/31/2031 12.0 Full Requirements (Capacity/Energy/PCs) See Note 4 12/30/2020 5/31/2027 Sale of PCs (Geothermal) 2.3 10/30/2009 12/31/2028 Apple NGR (Fort Churchill Solar) NGR Agreement (Sale of PCs) 19.5 8/5/2015 8/4/2040 Apple NGR (Boulder Solar II) NGR Agreement (Sale of PCs) 50.0 1/27/2017 12/31/2037 Switch NGR-SPPC (Switch Station 2) NGR Agreement (Sale of PCs) 79.0 10/11/2017 12/31/2037 Apple NGR (Techren II) NGR Agreement (Sale of PCs) 200.0 10/4/2019 6/20/2044 Apple NGR (Turquoise) NGR Agreement (Sale of PCs) 50.0 12/4/2020 4/30/2045 Notes: 1. The illustrative termination date shown is subject to certain conditions, which may result in termination before or after December 31, 2040. 2. RO Ranch Hydro facility is shut down indefinitely (the PPA is still active). 3. Facilities are either under development or construction (the dates shown are expected dates). 4. The current monthly contract demand ranges from approximately 70 MW (June) to 140 MW (December). Contract extension pending FERC approval. 5. Portfolio consists of multiple facilites under one Power Purchase Agreement 6. Storage reflects current MW based on annual storage capacity test 7. Emergency backup service agreement for King's Beach Diesels QF=Qualifying Facility, EWG=Exempt Wholesale Generator, S=Single Axis Tracking, T=Solar Thermal (Tracking), F=Fixed Tilt, X=Storage 38 Page 42 of 245
As listed on the current system
Question(s) Answered 19 thru 32 (CL&P dba Eversource Energy) Date Filed: 10/28/2026