Compliance Filing, Order No. 1
5. Annual Compliance Filings – Additional Filings (Program Materials)
Files13
2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
PDF · 221 KB · 3 pagesText searchable
Download 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdfRead the text of 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
PDF · 763 KB · 59 pagesText searchable
Download 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
PDF · 1.7 MB · 100 pagesText searchable
Download 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
PDF · 2.9 MB · 147 pagesText searchable
Download 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
PDF · 4.4 MB · 203 pagesText searchable
Download 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
PDF · 115 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
PDF · 159 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Excel · 100 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Excel · 272 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Excel · 3.5 MBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
PDF · 144 KB · 1 pageText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Excel · 71 KBText searchable
Download 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
PDF · 152 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
Extracted from the file · 147 pages · 342,741 characters
Page 54 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 54 of 203 During severe weather events as determined by the relevant EDC or by the BESS Operator, Aggregator, or OEM where there is a high likelihood of a grid outage Approved BESS Operators, Aggregators, or OEMs participating in Passive Dispatch must report all Passive Dispatch event hours during which their batteries were unable to perform due to an OEMtriggered severe storm event occurring within an uncanceled Passive Dispatch period. Such reports shall be submitted to the Program Administrators after the end of the Program’s Passive Dispatch season by October 15 of each year. As supporting evidence, Approved BESS Operators, Aggregators or OEMs must provide clear rationale and relevant data (e.g., National Weather Service alerts for the specific dates when the battery did not perform) to justify the cancellation of the Passive Dispatch hour. During Passive Dispatch events, Passive Dispatch Participants are required to discharge down to 20% of the BESS rated capacity. The Passive Dispatch window is 3 hours in duration. For example: a fully-charged BESS with 15 kWh rated energy capacity will have a maximum of 12 kWh available for Passive Dispatch and 3 kWh for reserve. During Passive Dispatch, the BESS will discharge at an average rate of 4 kWh per hour for the 3-hour duration. This is illustrated in the chart below: Figure 1: 15 kWh Battery Passive Dispatch 6.2.1. Legacy Passive Dispatch Season Performance and Claw Back Passive Dispatch Participants will be required to participate in Passive Dispatch events for ten (10) full years beginning on the date their system is connected to its respective DERMS. Participants who enroll partway through a Passive Dispatch season will not be penalized for partial participation. Rather, they will participate in the remainder of the season for Year 1, and in the beginning of the season for Year 11, totaling 10 full seasons of participation. Exiting from Energy Storage Solutions before the end of this period, or non-performance in Passive events during this period, will result in 53Page 55 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 55 of 203 non-compliance with Program requirements and the system owner will be required to return a prorated portion of the un-earned incentive. The claw back evaluation process will commence at the end of each summer season. The evaluation will determine whether a participating BESS scored greater than 90% for the Passive Dispatch season.44 Passive Dispatch participants are expected to make all efforts to have their BESS perform in compliance with Passive Dispatch rules. Program Administrators may periodically audit BESS that consistently perform below expectations (whether or not they comply with the Passive Dispatch Season Performance calculation below) to ensure ratepayer benefits are maximized. Table 13 [continued on the next page] describes the formula that will be used to determine each Legacy Participant’s Passive Dispatch Season Performance. 44 Legacy Passive Dispatch Participants are expected to dispatch 80% of available energy over the 3-hour Passive Dispatch window as uniformly as possible in accordance with the Passive Dispatch Season Performance criteria. 54Page 56 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 56 of 203 Table 13: Legacy Passive Dispatch Season Performance Formula Purpose Formula Component To ensure participants still receive credit for dispatching less than the required amount and to relax the Program’s uniform dispatch requirements, values may be less than 1 but no greater than 2. These values will then be summed across all Passive Dispatch event hours. An optimal score would be 1 for each hour 45. Σ (the energy discharged during a Passive Dispatch called event hour) / ((1/3) * (system’s available capacity at the start of the respective Passive Dispatch event – 20% of nameplate capacity)) To fully incentivize peak reduction through Active Dispatch participation46. (all Active Dispatch event hours called to replace a cancelled Passive Dispatch event in which a BESS discharged at least some portion of its available energy) [The allowable range for each Passive Dispatch hour’s score is 0 to 2 and scores that calculate as greater than 2 will be capped at 2.] + + To ensure participants are not penalized for Passive events canceled by the Program Administrators. (all Passive Dispatch hours cancelled by the Program Administrators that were not replaced by an Active Dispatch event) + To prevent penalties for OEMtriggered storm events that are beyond the customer’s control, allowing system usage during power outages. (all Passive Dispatch event hours called, and all Active Dispatch event hours called to replace a Passive Dispatch event, in which a battery could not perform because it was responding to an OEMtriggered severe storm event, provided the dispatch hour was not also cancelled by the Program Administrators) / To include all possible Passive Dispatch hours, if no events were canceled. (total possible Passive Dispatch hours in a given season) 45 The total score for this component is the sum of all individual scores from all Passive event hours unaffected by other formula components. Energy storage systems enrolled in Passive Dispatch should discharge 1/3 of their available energy during each Passive Dispatch event hour. For example, the system should discharge approximately 26.67% of its energy per hour (80%/3), assuming the system is fully charged at the start of the Passive event and accounting for the Program’s 20% reserve requirement, in order to earn full credit (three points) for the event. However, if the same system only discharges 13.34% of its nameplate capacity during the first Passive Dispatch hour, it would receive a score of 0.5 for that hour instead of a score of one. 46 As long as a system contributes any amount of energy back to the grid during each Active Dispatch event hour that replaces a canceled Passive Dispatch event, the system will receive full participation credit for those hours under the Passive Dispatch event participation formula. 55Page 57 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 57 of 203 The first Formula Component is used to score each Passive Dispatch hour in each season and is expressed mathematically below: 1 ( 3∗ ℎ ℎ ℎℎ ℎ − (0.2 ∗ )) Note: If score calculated above is greater than 2, the score will be capped at 2. The entire calculation used to score Passive Dispatch Season Performance is: ℎ = + + + A = Sum of Passive event scores for season B = Passive Dispatch hours replaced by Active events C = All Passive Dispatch hours canceled by the Program Administrators that were not replaced by an Active Dispatch event D = All Passive Dispatch event hours called, and all Active Dispatch event hours called to replace a Passive Dispatch event in which a battery could not perform because it was responding to an OEM-Triggered Severe Storm event, provided the Dispatch hour was not also canceled by the Program Administrators E = Total potential Passive Dispatch hours for the season Passive Dispatch Season Performance values less than 90% will trigger a claw back. When the claw back is triggered, the system owner will be responsible for a Violation Fee47 as follows: 1 − ℎ 0.9 ∗ ( ∗ 0.1) For systems that are owned by the participant (i.e. not owned by a third party), the Program Administrators may first contact the BESS Operator or OEM to investigate the cause of noncompliance. The BESS Operator or OEM can opt to pay the Violation Fee on behalf of the participant, though it is not required. For systems that are owned by a third-party, the Program Administrators will contact the system owner directly. In the event that Violation Fees are not paid as described above, available performance incentive payouts will be swept by CGB until the cost of the Violation Fee is recovered. If a clawback fee cannot be fully offset in the same Program year, the remaining amount shall roll forward to the next Program year and be deducted from any applicable performance incentives until the obligation is satisfied. If no performance incentive payouts are available to be swept or if a project’s clawback fee remains unpaid after reasonable collection efforts through performance incentives over multiple Program years, the Authority may authorize direct collection from the system owner via outreach or legal means at a later date. 47 For legacy systems enrolled mid-season, the period between the beginning of the season and enrollment in the program will not be assessed as “non-compliance” in the first year. 56Page 58 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 58 of 203 If the system owner is able to demonstrate a valid reason for non-compliance (e.g. equipment or software failure beyond the system owner’s control), they may appeal the Violation Fees to CGB directly. The Program Administrators are prohibited from unilaterally waiving any upfront incentive clawback fees. All clawback fee waivers require review and approval from the Public Utilities Regulatory Authority (PURA). To facilitate this process, the Program Administrators must submit all recommended clawback fee waivers to PURA for approval annually by November 1. Detailed examples of Passive Dispatch Season Performance and Violation Fees are provided at www.energystorageCT.com/contractor-resources. Passive Dispatch Participants will also be automatically enrolled in Active Dispatch. If a pattern of consistent non-performance of a particular BESS OEM, Operator, or Aggregator is identified, the Program Administrators will work with that party to improve performance. In the event that the OEM, Operator, or Aggregator is unable to improve performance due to technical issues, the Program Administrators reserve the right to suspend the OEM, Operator, or Aggregator per the process outlined in Section 4. 6.3. Calculation of Upfront Incentive Sec 6.3 applies only to Legacy Program customers enrolling in Passive Dispatch. The calculation of the Upfront incentive is primarily based on the nameplate energy capacity (kWh) of the BESS, with some limiting factors. The upfront residential incentive is calculated based on the minimum of the following three formulas: Residential Formula 1: BESS rated energy capacity (kWh) * [Applicable $/kWh rate at time of incentive application]48 Residential Formula 2: 50% of BESS total installed cost Residential Formula 3: Maximum per-residential unit incentive of $16,00049 The upfront C&I incentive is calculated based on the minimum of the following two formulas: C&I Formula 1: BESS rated energy capacity (kWh) * [Rate applicable to demand tier]50. C&I Formula 2: 50% of BESS total installed cost C&I systems are limited in power (kW) eligible to receive an upfront incentive to 150% of the customer’s annual peak demand or 2 MW, whichever is greater. The following illustrative examples demonstrate how incentive calculations work. These examples assume Residential Step 1 incentive rates from Table 8 and Commercial & Industrial 0-50MW Capacity Block incentive rates from Table 10. For additional examples and a calculator tool, along with the latest incentive rates and schedule, please visit the Energy Storage Solutions website. Example 1 - In the case of a 5 kW, 13.5 kWh battery with an installed cost of $20,000, for a standard Residential Customer: 48 kWh level as determined depending on the project type and incentive level as provided in Table 8. Residential Formula 3 does not apply to Multifamily Affordable Housing installations 50 kWh level as determined depending on the project type and incentive level as provided in Table 10. 49 57Page 59 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 59 of 203 13.5 kWh * $250/kWh, or $3,375 50% of $20,000, or $10,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $3,375. Example 2 – In the case of two batteries that add up to 15.2 kW, 36 kWh with an installed cost of $30,000, for a grid-edge Residential Customer: 36 kWh * $250/kWh, or $9,000 + 50% adder = $13,500 50% of $30,000, or $15,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $13,500. Example 3 – In the case of two batteries that add up to 10 kW, 27 kWh with an installed cost of $30,000, for a low-income Residential Customer: 27 kWh * $600/kWh, or $16,200 50% of $30,000, or $15,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $15,000. Example 4 – In the case of a 250 kW, 675 kWh battery for a medium-sized Commercial customer with an annual peak demand of 240 kW and an installed cost of $378,000 (Tranche 3 Step 1) 675 kWh * $159.25/kWh, or $107,494 50% of $378,000, or $189,000 The customer would receive an upfront incentive of $107,494. Example 5 – In the case of a 3 MW, 10 MWh battery for a large-sized Commercial grid-edge customer with an annual peak demand of 2 MW and an installed cost of $2,500,000 (Tranche 3 Step 1) 10,000 kWh * $91/kWh, or $910,000 +25% grid-edge adder = $1,137,500 50% of $2,500,000, or $1,250,000 The customer would receive an upfront incentive of $1,137,500 Example 6 – In the case of a 1.4 MW, 5 MWh battery for a small-sized Commercial small business customer with an annual peak demand of 180 kW and an installed cost of $1,950,000 (Tranche 3 Step 1) System is > 150% of customer’s peak demand, but < 2 MW. Incentive cap not exceeded. Tiered incentive calculation51 + 25% small business adder = $741,406 50% of $1,950,000, or $975,000 51 Use current ESS Calculator available at www.energystorageCT.com/contractor-resources for a detailed breakdown of the tiered incentive calculation. 58Page 60 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 60 of 203 The customer would receive an upfront incentive of $741,406 Example 7 – In the case of a 3 MW, 15 MWh battery for a large-sized Commercial customer with an annual peak demand of 750 kW and an installed cost of $3,500,000 (Tranche 3 Step 1) System is not capable of dispatching 80% of its capacity in a 3-hour Passive Dispatch window System is > 150% of customer’s peak demand and > 2 MW, exceeding incentive cap 150% of peak demand = 1.125 MW. Capped system size is 2 MW The project must be redesigned and resubmitted. For Eligible BESS Equipment that was approved prior to the Passive Dispatch window changing from 5 hours to 3 hours, (“Legacy Eligible BESS Equipment”), customers may apply for a prorated upfront incentive that is calculated based on the portion of the BESS that can comply with the current Passive Dispatch rules. Example 8 – In the case of a 5 kW, 30 kWh battery for a residential customer, the battery is not capable of discharging 80% of its nameplate capacity in 3 hours for 90% seasonal participation due to the limitation of the inverter size. The customer may enroll up to 20.83 kWh of capacity: 5 kW * 3 hours / 80% discharge / 90% minimum participation = 20.83. This formula may also be stated as [Inverter Size] * 4.166 for the minimum threshold of participation, or [Inverter Size] * 3.75 to allow 10% buffer for missed Passive Dispatch events. 6.4. Calculation of Enrollment Incentive (Effective 4/1/26) Sec 6.4 applies only to Construct 5 customers enrolling on or after 4/1/26. The calculation of the Enrollment Incentive is based on the nameplate energy capacity (kWh) of the BESS. Both residential and commercial Enrollment Incentives are calculated based on the following rates: Customer Category Enrollment Incentive Rate* Residential (Non-Grid Edge) $30/kWh Residential (Grid Edge) $130/kWh Commercial (Non-Priority) Commercial (Priority) N/A $10/kWh *Enrollment incentives are defined based on rated energy capacity (kWh) For additional examples and a calculator tool, along with the latest incentive rates and schedule, please visit the Energy Storage Solutions website. Example 1 - In the case of a 5 kW, 13.5 kWh battery for a standard non-grid edge residential customer: 59Page 61 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 61 of 203 13.5 kWh * $30 The customer would receive an upfront incentive of $405. Example 2 - In the case of a 5 kW, 13.5 kWh battery for a grid edge residential customer: 13.5 kWh * $130 The customer would receive an upfront incentive of $1,755. Example 3 - In the case of a 7 MW, 15 MWh battery for a grid edge commercial customer: 15,000 kWh * $10 The customer would receive an upfront incentive of $150,000. 6.5. Active Dispatch Sec 6.1 applies to both Legacy Program customers and Construct 5 Customers. Sec 6.5 applies to all customers enrolling in Energy Storage Solutions, including those enrolled after April 1, 2026. Active Dispatch Participants will be enrolled and eligible to participate in Active events for ten (10) full years beginning on the date their system is connected to its respective DERMS. Customers can enroll at any time. A customer who enrolls part way through a season may participate in the remainder of the season for Year 1, and in the beginning of the season for Year 11, totaling 10 full seasons of participation. Exiting from Energy Storage Solutions Active Dispatch before the end of this period or declining events will not yield any violation. When an Active Dispatch event is called, the Passive Dispatch event for that day is cancelled. In the situation that an Active Dispatch event is called by the EDCs during the Passive Dispatch hours, the Active Dispatch shall take precedence over the Passive Dispatch event. Table 14: Summer and Winter Active Dispatch Parameters Season Dates Number of Events Event Duration Timing Summer June 1 – September 30 30-60 1 - 3 hours 12:00 PM to 9:00 PM Winter November 1 – March 31 1-5 (Legacy) 1-10 (Construct 5) 1 - 3 hours 12:00 PM to 9:00 PM The incentive rate tied to performance during Active Dispatch events for each option is shown in Table 15 and Table 16. Table 15: Active Dispatch Performance Incentive for Legacy Customers (1/1/22 – 3/31/26) BESS Performance Period Years 1 – 5 Years 6 – 10 Summer Performance Incentive ($/kW)* $200 $115 Winter Performance Incentive ($/kW)* $25 $15 60Page 62 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 62 of 203 *Applies equally to all customer types. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. Table 16: Active Dispatch Performance Incentive for Construct 5 Customers (Effective 4/1/26) Customer Class Years 1 – 5 Years 6 – 10 Small or Medium C&I $325/kW $175/kW Large C&I $275/kW $175/kW Standard Residential $300/kW Underserved Residential* $450/kW Low-Income Residential* $550/kW *Applies based on Customer Class at the time of application. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. **For Construct 5 customers choosing the biannual payment option, the annual performance incentives will be allocated 11% to winter dispatch and 89% to summer dispatch Participating customers are eligible to receive performance incentives for the same BESS for up to 10 years. These 10 years of eligible performance incentives may be structured as one rate for 10 years, or split into an opening period (years 1 – 5) and a closing period (years 6 – 10). Customers may also be granted a construction hold commencing on the Reservation of Funds (ROF) date (if extensions are granted per Sec. 3.6). The construction hold will temporarily lock in the performance incentive rates at that cycle while the BESS is built. The extension hold requires certain milestones are met as described in Section 3. Systems built under the granted timeframe (if granted an extension per Sec. 3.6) may be immediately eligible to start their enrollment term upon successfully completing all required completion milestones. Systems that require longer than the granted timeframe of construction or those that do not meet the required milestones within the hold must reapply to Energy Storage Solutions and will be reviewed under the cycle rates current to that time. If a system’s opening period commenced mid-season, that system will receive 0 kW as performance for any missed events but will be allowed to earn performance on any remaining events of that season. 61Page 63 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 63 of 203 Table 17: Project Application and Approval Timeline Milestone Application to Program Duration - Application Approval 30 days (Max) from Application Construction Hold 36 Months (Max) from ROF Approval (Described in Section 4: Enrollment) Enrollment Start The sooner of: 36 Months from Application approval or System ready for dispatch Program Performance End 10 Years from Enrollment Start 6.6. Active Dispatch Incentive Rates and Average Performance Sec 6.6 applies to both Legacy Program customers and Construct 5 Customers. Performance is measured as the average discharge capacity from the BESS across all Active events during the given season. If the BESS is dispatched with less than 24 hours notice, the event will not be counted in the calculation of the seasonal performance incentive however, BESS that participate in such events will be compensated for their performance at the applicable rates. If a participant opts out of an event or has some communication or other issue that prevents them from discharging during an event, they will be given a 0 kW performance for that event. These will affect the participant’s average performance and incentive. The performance incentive rates refer to the average dispatch amount across all events of the dispatch season. Eligible BESS Aggregators, Operators, or OEMs must provide twenty-four hours a day, seven days a week service with 15-minute intervals (or more granular data) for the entire demand response season in order to receive fees or for their customers to receive performance incentives. Lapses in service that result in missing data during an event will result in performance being measured at 0 kW-AC for the duration of the missing data. Performance per event is equal to the average discharge rate of the BESS in kW-AC over the length of the event as described below. Active Dispatch does not require the customer to hold any reserve capacity. Events will dispatch assuming all capacity is available to the OEM minimum required reserve capacity. Therefore, participants may dispatch their full available capacity during Active Events to maximize performance incentives. This would yield an average dispatch of 1/3 of the usable energy capacity per hour during a 3-hour event for a fully charged battery. Using the previous example of a 15 kWh system, a participant with a fully charged system would be able to participate at up to 5 kWh per hour over a 3-hour Active Dispatch event, for an average of 5 kW for that event, provided there is no OEM minimum required reserve capacity set for the system. 62
Text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
Extracted from the file · 2 pages · 6,256 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
Extracted from the file · 2 pages · 3,261 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
Extracted from the file · 1 page · 528 characters
Text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Extracted from the file · 2 pages · 4,800 characters
As listed on the current system
Compliance Filings, 11/16/2026 [26-08-01] Order No.1 / Avangrid / 5. Annual Compliance Filings – Additional Filings (Program Materials)