Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compliance Filing, Order No. 1

5. Annual Compliance Filings – Additional Filings (Program Materials)

Compliance filingFiled by Avangrid13 files
Part of docket 26-08-01Open
  • Electric
2026 Clean and Renewable Energy Program Data and Report

Files13

Search terms highlighted
Eversource rate increase is on 8 pages of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf

Extracted from the file · 147 pages · 342,741 characters

8 pages match
  1. Page 57 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 57 of 203 The first Formula Component is used to score each Passive Dispatch hour in each season and is expressed mathematically below: 1 ( 3∗ ℎ ℎ ℎℎ ℎ − (0.2 ∗ )) Note: If score calculated above is greater than 2, the score will be capped at 2. The entire calculation used to score Passive Dispatch Season Performance is: ℎ = + + + A = Sum of Passive event scores for season B = Passive Dispatch hours replaced by Active events C = All Passive Dispatch hours canceled by the Program Administrators that were not replaced by an Active Dispatch event D = All Passive Dispatch event hours called, and all Active Dispatch event hours called to replace a Passive Dispatch event in which a battery could not perform because it was responding to an OEM-Triggered Severe Storm event, provided the Dispatch hour was not also canceled by the Program Administrators E = Total potential Passive Dispatch hours for the season Passive Dispatch Season Performance values less than 90% will trigger a claw back. When the claw back is triggered, the system owner will be responsible for a Violation Fee47 as follows: 1 − ℎ 0.9 ∗ ( ∗ 0.1) For systems that are owned by the participant (i.e. not owned by a third party), the Program Administrators may first contact the BESS Operator or OEM to investigate the cause of noncompliance. The BESS Operator or OEM can opt to pay the Violation Fee on behalf of the participant, though it is not required. For systems that are owned by a third-party, the Program Administrators will contact the system owner directly. In the event that Violation Fees are not paid as described above, available performance incentive payouts will be swept by CGB until the cost of the Violation Fee is recovered. If a clawback fee cannot be fully offset in the same Program year, the remaining amount shall roll forward to the next Program year and be deducted from any applicable performance incentives until the obligation is satisfied. If no performance incentive payouts are available to be swept or if a project’s clawback fee remains unpaid after reasonable collection efforts through performance incentives over multiple Program years, the Authority may authorize direct collection from the system owner via outreach or legal means at a later date. 47 For legacy systems enrolled mid-season, the period between the beginning of the season and enrollment in the program will not be assessed as “non-compliance” in the first year. 56
  2. Page 58 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 58 of 203 If the system owner is able to demonstrate a valid reason for non-compliance (e.g. equipment or software failure beyond the system owner’s control), they may appeal the Violation Fees to CGB directly. The Program Administrators are prohibited from unilaterally waiving any upfront incentive clawback fees. All clawback fee waivers require review and approval from the Public Utilities Regulatory Authority (PURA). To facilitate this process, the Program Administrators must submit all recommended clawback fee waivers to PURA for approval annually by November 1. Detailed examples of Passive Dispatch Season Performance and Violation Fees are provided at www.energystorageCT.com/contractor-resources. Passive Dispatch Participants will also be automatically enrolled in Active Dispatch. If a pattern of consistent non-performance of a particular BESS OEM, Operator, or Aggregator is identified, the Program Administrators will work with that party to improve performance. In the event that the OEM, Operator, or Aggregator is unable to improve performance due to technical issues, the Program Administrators reserve the right to suspend the OEM, Operator, or Aggregator per the process outlined in Section 4. 6.3. Calculation of Upfront Incentive Sec 6.3 applies only to Legacy Program customers enrolling in Passive Dispatch. The calculation of the Upfront incentive is primarily based on the nameplate energy capacity (kWh) of the BESS, with some limiting factors. The upfront residential incentive is calculated based on the minimum of the following three formulas: Residential Formula 1: BESS rated energy capacity (kWh) * [Applicable $/kWh rate at time of incentive application]48 Residential Formula 2: 50% of BESS total installed cost Residential Formula 3: Maximum per-residential unit incentive of $16,00049 The upfront C&I incentive is calculated based on the minimum of the following two formulas: C&I Formula 1: BESS rated energy capacity (kWh) * [Rate applicable to demand tier]50. C&I Formula 2: 50% of BESS total installed cost C&I systems are limited in power (kW) eligible to receive an upfront incentive to 150% of the customer’s annual peak demand or 2 MW, whichever is greater. The following illustrative examples demonstrate how incentive calculations work. These examples assume Residential Step 1 incentive rates from Table 8 and Commercial & Industrial 0-50MW Capacity Block incentive rates from Table 10. For additional examples and a calculator tool, along with the latest incentive rates and schedule, please visit the Energy Storage Solutions website. Example 1 - In the case of a 5 kW, 13.5 kWh battery with an installed cost of $20,000, for a standard Residential Customer: 48 kWh level as determined depending on the project type and incentive level as provided in Table 8. Residential Formula 3 does not apply to Multifamily Affordable Housing installations 50 kWh level as determined depending on the project type and incentive level as provided in Table 10. 49 57
  3. Page 59 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 59 of 203 13.5 kWh * $250/kWh, or $3,375 50% of $20,000, or $10,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $3,375. Example 2 – In the case of two batteries that add up to 15.2 kW, 36 kWh with an installed cost of $30,000, for a grid-edge Residential Customer: 36 kWh * $250/kWh, or $9,000 + 50% adder = $13,500 50% of $30,000, or $15,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $13,500. Example 3 – In the case of two batteries that add up to 10 kW, 27 kWh with an installed cost of $30,000, for a low-income Residential Customer: 27 kWh * $600/kWh, or $16,200 50% of $30,000, or $15,000 Maximum incentive of $16,000 The customer would receive an upfront incentive of $15,000. Example 4 – In the case of a 250 kW, 675 kWh battery for a medium-sized Commercial customer with an annual peak demand of 240 kW and an installed cost of $378,000 (Tranche 3 Step 1) 675 kWh * $159.25/kWh, or $107,494 50% of $378,000, or $189,000 The customer would receive an upfront incentive of $107,494. Example 5 – In the case of a 3 MW, 10 MWh battery for a large-sized Commercial grid-edge customer with an annual peak demand of 2 MW and an installed cost of $2,500,000 (Tranche 3 Step 1) 10,000 kWh * $91/kWh, or $910,000 +25% grid-edge adder = $1,137,500 50% of $2,500,000, or $1,250,000 The customer would receive an upfront incentive of $1,137,500 Example 6 – In the case of a 1.4 MW, 5 MWh battery for a small-sized Commercial small business customer with an annual peak demand of 180 kW and an installed cost of $1,950,000 (Tranche 3 Step 1) System is > 150% of customer’s peak demand, but < 2 MW. Incentive cap not exceeded. Tiered incentive calculation51 + 25% small business adder = $741,406 50% of $1,950,000, or $975,000 51 Use current ESS Calculator available at www.energystorageCT.com/contractor-resources for a detailed breakdown of the tiered incentive calculation. 58
  4. Page 60 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 60 of 203 The customer would receive an upfront incentive of $741,406 Example 7 – In the case of a 3 MW, 15 MWh battery for a large-sized Commercial customer with an annual peak demand of 750 kW and an installed cost of $3,500,000 (Tranche 3 Step 1) System is not capable of dispatching 80% of its capacity in a 3-hour Passive Dispatch window System is > 150% of customer’s peak demand and > 2 MW, exceeding incentive cap 150% of peak demand = 1.125 MW. Capped system size is 2 MW The project must be redesigned and resubmitted. For Eligible BESS Equipment that was approved prior to the Passive Dispatch window changing from 5 hours to 3 hours, (“Legacy Eligible BESS Equipment”), customers may apply for a prorated upfront incentive that is calculated based on the portion of the BESS that can comply with the current Passive Dispatch rules. Example 8 – In the case of a 5 kW, 30 kWh battery for a residential customer, the battery is not capable of discharging 80% of its nameplate capacity in 3 hours for 90% seasonal participation due to the limitation of the inverter size. The customer may enroll up to 20.83 kWh of capacity: 5 kW * 3 hours / 80% discharge / 90% minimum participation = 20.83. This formula may also be stated as [Inverter Size] * 4.166 for the minimum threshold of participation, or [Inverter Size] * 3.75 to allow 10% buffer for missed Passive Dispatch events. 6.4. Calculation of Enrollment Incentive (Effective 4/1/26) Sec 6.4 applies only to Construct 5 customers enrolling on or after 4/1/26. The calculation of the Enrollment Incentive is based on the nameplate energy capacity (kWh) of the BESS. Both residential and commercial Enrollment Incentives are calculated based on the following rates: Customer Category Enrollment Incentive Rate* Residential (Non-Grid Edge) $30/kWh Residential (Grid Edge) $130/kWh Commercial (Non-Priority) Commercial (Priority) N/A $10/kWh *Enrollment incentives are defined based on rated energy capacity (kWh) For additional examples and a calculator tool, along with the latest incentive rates and schedule, please visit the Energy Storage Solutions website. Example 1 - In the case of a 5 kW, 13.5 kWh battery for a standard non-grid edge residential customer: 59
  5. Page 61 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 61 of 203 13.5 kWh * $30 The customer would receive an upfront incentive of $405. Example 2 - In the case of a 5 kW, 13.5 kWh battery for a grid edge residential customer: 13.5 kWh * $130 The customer would receive an upfront incentive of $1,755. Example 3 - In the case of a 7 MW, 15 MWh battery for a grid edge commercial customer: 15,000 kWh * $10 The customer would receive an upfront incentive of $150,000. 6.5. Active Dispatch Sec 6.1 applies to both Legacy Program customers and Construct 5 Customers. Sec 6.5 applies to all customers enrolling in Energy Storage Solutions, including those enrolled after April 1, 2026. Active Dispatch Participants will be enrolled and eligible to participate in Active events for ten (10) full years beginning on the date their system is connected to its respective DERMS. Customers can enroll at any time. A customer who enrolls part way through a season may participate in the remainder of the season for Year 1, and in the beginning of the season for Year 11, totaling 10 full seasons of participation. Exiting from Energy Storage Solutions Active Dispatch before the end of this period or declining events will not yield any violation. When an Active Dispatch event is called, the Passive Dispatch event for that day is cancelled. In the situation that an Active Dispatch event is called by the EDCs during the Passive Dispatch hours, the Active Dispatch shall take precedence over the Passive Dispatch event. Table 14: Summer and Winter Active Dispatch Parameters Season Dates Number of Events Event Duration Timing Summer June 1 – September 30 30-60 1 - 3 hours 12:00 PM to 9:00 PM Winter November 1 – March 31 1-5 (Legacy) 1-10 (Construct 5) 1 - 3 hours 12:00 PM to 9:00 PM The incentive rate tied to performance during Active Dispatch events for each option is shown in Table 15 and Table 16. Table 15: Active Dispatch Performance Incentive for Legacy Customers (1/1/22 – 3/31/26) BESS Performance Period Years 1 – 5 Years 6 – 10 Summer Performance Incentive ($/kW)* $200 $115 Winter Performance Incentive ($/kW)* $25 $15 60
  6. Page 62 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 62 of 203 *Applies equally to all customer types. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. Table 16: Active Dispatch Performance Incentive for Construct 5 Customers (Effective 4/1/26) Customer Class Years 1 – 5 Years 6 – 10 Small or Medium C&I $325/kW $175/kW Large C&I $275/kW $175/kW Standard Residential $300/kW Underserved Residential* $450/kW Low-Income Residential* $550/kW *Applies based on Customer Class at the time of application. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. **For Construct 5 customers choosing the biannual payment option, the annual performance incentives will be allocated 11% to winter dispatch and 89% to summer dispatch Participating customers are eligible to receive performance incentives for the same BESS for up to 10 years. These 10 years of eligible performance incentives may be structured as one rate for 10 years, or split into an opening period (years 1 – 5) and a closing period (years 6 – 10). Customers may also be granted a construction hold commencing on the Reservation of Funds (ROF) date (if extensions are granted per Sec. 3.6). The construction hold will temporarily lock in the performance incentive rates at that cycle while the BESS is built. The extension hold requires certain milestones are met as described in Section 3. Systems built under the granted timeframe (if granted an extension per Sec. 3.6) may be immediately eligible to start their enrollment term upon successfully completing all required completion milestones. Systems that require longer than the granted timeframe of construction or those that do not meet the required milestones within the hold must reapply to Energy Storage Solutions and will be reviewed under the cycle rates current to that time. If a system’s opening period commenced mid-season, that system will receive 0 kW as performance for any missed events but will be allowed to earn performance on any remaining events of that season. 61
  7. Page 63 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 63 of 203 Table 17: Project Application and Approval Timeline Milestone Application to Program Duration - Application Approval 30 days (Max) from Application Construction Hold 36 Months (Max) from ROF Approval (Described in Section 4: Enrollment) Enrollment Start The sooner of: 36 Months from Application approval or System ready for dispatch Program Performance End 10 Years from Enrollment Start 6.6. Active Dispatch Incentive Rates and Average Performance Sec 6.6 applies to both Legacy Program customers and Construct 5 Customers. Performance is measured as the average discharge capacity from the BESS across all Active events during the given season. If the BESS is dispatched with less than 24 hours notice, the event will not be counted in the calculation of the seasonal performance incentive however, BESS that participate in such events will be compensated for their performance at the applicable rates. If a participant opts out of an event or has some communication or other issue that prevents them from discharging during an event, they will be given a 0 kW performance for that event. These will affect the participant’s average performance and incentive. The performance incentive rates refer to the average dispatch amount across all events of the dispatch season. Eligible BESS Aggregators, Operators, or OEMs must provide twenty-four hours a day, seven days a week service with 15-minute intervals (or more granular data) for the entire demand response season in order to receive fees or for their customers to receive performance incentives. Lapses in service that result in missing data during an event will result in performance being measured at 0 kW-AC for the duration of the missing data. Performance per event is equal to the average discharge rate of the BESS in kW-AC over the length of the event as described below. Active Dispatch does not require the customer to hold any reserve capacity. Events will dispatch assuming all capacity is available to the OEM minimum required reserve capacity. Therefore, participants may dispatch their full available capacity during Active Events to maximize performance incentives. This would yield an average dispatch of 1/3 of the usable energy capacity per hour during a 3-hour event for a fully charged battery. Using the previous example of a 15 kWh system, a participant with a fully charged system would be able to participate at up to 5 kWh per hour over a 3-hour Active Dispatch event, for an average of 5 kW for that event, provided there is no OEM minimum required reserve capacity set for the system. 62
  8. Page 64 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 64 of 203 Continuing with this example, a typical summer season may have 40 Active Dispatch events called. This participant did not participate in 5 events. This could be due to many reasons such as the BESS not being installed until mid-season, participant opt-outs, or the Operator was unable to provide data. In all cases of non-participation, the participant is given 0 kW across those event hours. However, for the remaining event hours the participant participated at an average hourly output of 5 kW. The average of 5 3-hour events at 0 kW and 35 3-hour events at 5 kW is an average summer seasonal performance of 4.375 kW. For Construct 5 customers, the summer performance rate is equal to 89% of the approved Performance Rate. The summer performance incentive will be calculated as $200/kW x 4.375 kW = $875 (Legacy customer) or $300/kW x 4.375 x 89% = $1,168 (Construct 5),. For Legacy customers or Construct 5 customers who elect for seasonal payments, the average season performance for winter events will be a separate incentive calculation using the same process, based on the winter performance rate. For Construct 5 customers, the winter performance rate is equal to 11% of the approved Performance Rate. If the participant in the example participates, as expected, at 5 kW for all winter events the Standard incentive would be calculated as: $25/kW x 5 kW = $125 (Legacy) or $300/kW x 5kW x 11% = $165 (Construct 5). Over the course of both seasons this participant was able to earn $875 + $125 = $1,000 (Legacy) or $1,168 + $165 = $1,333 (Construct 5) in Active Dispatch performance incentives for the year. The calculation of incentive benefit specified here is subject to change by the Program Administrators (with PURA’s approval) and will be indicated on the Program website, customer enrollment forms and other Program materials. 6.7. Incentive Payment Process Sec 6.7 applies to both Legacy Program customers and Construct 5 Customers. CGB will administer all upfront or enrollment payment following the approval of the Application, an inspection (if opted-in) or self-inspection of the system’s installation at the discretion of the Program Administrators, and the provision of proof of enrollment in both Active and Passive Dispatch (where applicable) portions of Energy Storage Solutions. The relevant EDC will administer the incentive payments for summer and winter performance, as calculated in the “Incentive Rates and Average Performance” section. For legacy Passive Dispatch customers, the relevant EDC will issue the seasonal Active Performance payment after Passive Claw Back amounts are finalized and subtracted from the Active Performance payment due. New Construct 5 Customers or Legacy Passive Dispatch whose clawback obligations have been fully met will typically be paid within 6-8 weeks of the conclusion of the dispatch season. Upfront and Enrollment Incentive Payments Upfront and Enrollment incentives are provided as upfront discounts reflected in the customer’s purchase or lease agreement with their Contractor or TPO. CGB will disburse upfront incentive reimbursements to eligible Contractors or TPOs as indicated on the Application. After incentive Reservation and once the system is installed and energized, Contractors and TPOs shall submit proof of project completion and interconnection through the Customer Enrollment Platform. Once verified by CGB that installation was performed in accordance with the original or 63
  9. Page 65 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 65 of 203 amended incentive application, all completion documentation has been submitted and approved, Passive Dispatch enrollment has been verified (where applicable), and all applicable Program requirements have been met, the project will be eligible to have the Upfront or Enrollment Incentive reimbursed to the Contractor or TPO. CGB will process incentive payments to Contractors and TPOs in monthly batches. If a battery system is not installed properly or in accordance with the proposed system specifications submitted to the Program Administrators, CGB reserves the right to withhold or recalculate Upfront or Enrollment incentive payments based on actual installed equipment and site conditions. Additionally, the Program Administrators may stop approving incentive applications and/or withhold payments for Contractors and TPOs that consistently have problems properly installing BESS and/or complying with the requirements of Energy Storage Solutions. Additional information regarding Upfront and Enrollment Incentive payments will be made available by the Program Administrators in a separate document on the Energy Storage Solutions website. Performance Incentive Data and Payments Performance incentives will be calculated in accordance with Section 6.3. and paid by the EDCs following the Summer and Winter seasons for all customers enrolled prior to April 1, 2026. The relevant EDC will administer the incentive payments for summer and winter performance, as calculated in the “Incentive Rates and Average Performance” section. For legacy Passive Dispatch customers, the relevant EDC will issue the seasonal payment after Passive Claw Back amounts are finalized and subtracted from the Active Performance payment due. New Construct 5 Customers or Legacy Passive Dispatch whose clawback obligations have been fully met will typically be paid within two months of the conclusion of the dispatch season Customers enrolling on or after April 1, 2026 will have the option to receive their performance incentive payments either annually or biannually at the point of program application. Customers who select the annual payment option will receive a single payment that combines both the winter and summer performance incentives. This payment will be issued within two months of the conclusion of the summer dispatch season. Customers who select the biannual payment option will receive two separate payments: one for the winter dispatch season and one for the summer dispatch season. Each payment will be issued within two months after the respective dispatch season concludes. The incentive rates are 11% ($33/kW for Residential standard) for the winter dispatch season, and 89% ($267/kW for Residential standard) for the summer dispatch season. To enhance data transparency and support Program enrollment, the Program Administrators must provide all available Active and Passive Dispatch performance data to ESS customers upon request, within 90 days after the end of a dispatch season after a data request is made. Direct Payments Battery storage owners will have access to direct payment options, which will support PURA’s key Program objectives, including facilitating deployment of battery storage in LMI and vulnerable communities, while at the same time reducing risk to homeowners and capital providers and lowering system financing costs. 64
  10. Page 66 of 203

    The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 66 of 203 Customers can designate a direct payment payee at the time of enrollment, and EDCs will assign performance incentive payments in part of in full to a TPO, vendor, financial institution, or other party as specified by the Customer. Customer must complete a Direct Payment Beneficiary Form, available in Appendix G or at energystorageCT.com/contractor-resources. 6.8. Days for Dispatch Events Sec 6.8 applies to both Legacy Program customers and Construct 5 Customers. Active discharge events are called on weekends, weekdays, or holidays – for both summer and winter. Passive discharge events are limited to non-holiday weekdays during the Summer season (June, July and August) only. Holidays excluded from Passive Dispatch events include: Table 18: Holidays for Passive Dispatch Events Dispatch Season Summer Holiday Independence Day Typical Date July 4 Summer Juneteenth June 19 6.9. No Demand Response Events Before Large Storms Sec 6.9 applies to both Legacy Program customers and Construct 5 Customers. Customers often purchase energy storage systems in part for backup power during power outages. Under non-storm operating scenarios, no more than 80 percent of available energy capacity will be used during Passive events, leaving 20 percent available for backup power. The EDCs will cancel events (Active or Passive) for the two (2) days preceding any predicted Emergency Restoration Plan level (level 1-5) outage events, leaving the customer to use the BESS as the customer deems appropriate. 6.10. Performance Testing Sec 6.10 applies to both Legacy Program customers and Construct 5 Customers. The Program Administrators may conduct performance tests of the BESS during installation or during periodic inspections (if opted-in). However, the Program Administrators may periodically elect to run communication tests to ensure all notification processes are functioning. A BESS Commissioning & Acceptance Testing program that will ensure that system perform as designed and that the system meets the Technical Requirements and performs as expected. Commissioning documentation typically includes but is not limited to: Electrical Design verification Certificates of Code Compliance Power/Energy Capability testing 65

Text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf

Extracted from the file · 2 pages · 6,256 characters

Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf

Extracted from the file · 2 pages · 3,261 characters

Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx

Sheet names, column headings and text cells; numbers left out

Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx

Sheet names, column headings and text cells; numbers left out

Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf

Extracted from the file · 1 page · 528 characters

Text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx

Sheet names, column headings and text cells; numbers left out

Text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf

Extracted from the file · 2 pages · 4,800 characters

As listed on the current system

Compliance Filings, 11/16/2026 [26-08-01] Order No.1 / Avangrid / 5. Annual Compliance Filings – Additional Filings (Program Materials)

This filing on the current system (opens in a new tab)