Compliance Filing, Order No. 1
5. Annual Compliance Filings – Additional Filings (Program Materials)
Files13
2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
PDF · 221 KB · 3 pagesText searchable
Download 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdfRead the text of 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
PDF · 763 KB · 59 pagesText searchable
Download 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
PDF · 1.7 MB · 100 pagesText searchable
Download 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
PDF · 2.9 MB · 147 pagesText searchable
Download 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
PDF · 4.4 MB · 203 pagesText searchable
Download 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
PDF · 115 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
PDF · 159 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Excel · 100 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Excel · 272 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Excel · 3.5 MBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
PDF · 144 KB · 1 pageText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Excel · 71 KBText searchable
Download 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
PDF · 152 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
Extracted from the file · 147 pages · 342,741 characters
Page 62 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 62 of 203 *Applies equally to all customer types. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. Table 16: Active Dispatch Performance Incentive for Construct 5 Customers (Effective 4/1/26) Customer Class Years 1 – 5 Years 6 – 10 Small or Medium C&I $325/kW $175/kW Large C&I $275/kW $175/kW Standard Residential $300/kW Underserved Residential* $450/kW Low-Income Residential* $550/kW *Applies based on Customer Class at the time of application. Performance incentives are based on average kW-AC contribution during the season, determined by actual system performance during events as indicated by inverter data, not nameplate capacity. **For Construct 5 customers choosing the biannual payment option, the annual performance incentives will be allocated 11% to winter dispatch and 89% to summer dispatch Participating customers are eligible to receive performance incentives for the same BESS for up to 10 years. These 10 years of eligible performance incentives may be structured as one rate for 10 years, or split into an opening period (years 1 – 5) and a closing period (years 6 – 10). Customers may also be granted a construction hold commencing on the Reservation of Funds (ROF) date (if extensions are granted per Sec. 3.6). The construction hold will temporarily lock in the performance incentive rates at that cycle while the BESS is built. The extension hold requires certain milestones are met as described in Section 3. Systems built under the granted timeframe (if granted an extension per Sec. 3.6) may be immediately eligible to start their enrollment term upon successfully completing all required completion milestones. Systems that require longer than the granted timeframe of construction or those that do not meet the required milestones within the hold must reapply to Energy Storage Solutions and will be reviewed under the cycle rates current to that time. If a system’s opening period commenced mid-season, that system will receive 0 kW as performance for any missed events but will be allowed to earn performance on any remaining events of that season. 61Page 63 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 63 of 203 Table 17: Project Application and Approval Timeline Milestone Application to Program Duration - Application Approval 30 days (Max) from Application Construction Hold 36 Months (Max) from ROF Approval (Described in Section 4: Enrollment) Enrollment Start The sooner of: 36 Months from Application approval or System ready for dispatch Program Performance End 10 Years from Enrollment Start 6.6. Active Dispatch Incentive Rates and Average Performance Sec 6.6 applies to both Legacy Program customers and Construct 5 Customers. Performance is measured as the average discharge capacity from the BESS across all Active events during the given season. If the BESS is dispatched with less than 24 hours notice, the event will not be counted in the calculation of the seasonal performance incentive however, BESS that participate in such events will be compensated for their performance at the applicable rates. If a participant opts out of an event or has some communication or other issue that prevents them from discharging during an event, they will be given a 0 kW performance for that event. These will affect the participant’s average performance and incentive. The performance incentive rates refer to the average dispatch amount across all events of the dispatch season. Eligible BESS Aggregators, Operators, or OEMs must provide twenty-four hours a day, seven days a week service with 15-minute intervals (or more granular data) for the entire demand response season in order to receive fees or for their customers to receive performance incentives. Lapses in service that result in missing data during an event will result in performance being measured at 0 kW-AC for the duration of the missing data. Performance per event is equal to the average discharge rate of the BESS in kW-AC over the length of the event as described below. Active Dispatch does not require the customer to hold any reserve capacity. Events will dispatch assuming all capacity is available to the OEM minimum required reserve capacity. Therefore, participants may dispatch their full available capacity during Active Events to maximize performance incentives. This would yield an average dispatch of 1/3 of the usable energy capacity per hour during a 3-hour event for a fully charged battery. Using the previous example of a 15 kWh system, a participant with a fully charged system would be able to participate at up to 5 kWh per hour over a 3-hour Active Dispatch event, for an average of 5 kW for that event, provided there is no OEM minimum required reserve capacity set for the system. 62Page 64 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 64 of 203 Continuing with this example, a typical summer season may have 40 Active Dispatch events called. This participant did not participate in 5 events. This could be due to many reasons such as the BESS not being installed until mid-season, participant opt-outs, or the Operator was unable to provide data. In all cases of non-participation, the participant is given 0 kW across those event hours. However, for the remaining event hours the participant participated at an average hourly output of 5 kW. The average of 5 3-hour events at 0 kW and 35 3-hour events at 5 kW is an average summer seasonal performance of 4.375 kW. For Construct 5 customers, the summer performance rate is equal to 89% of the approved Performance Rate. The summer performance incentive will be calculated as $200/kW x 4.375 kW = $875 (Legacy customer) or $300/kW x 4.375 x 89% = $1,168 (Construct 5),. For Legacy customers or Construct 5 customers who elect for seasonal payments, the average season performance for winter events will be a separate incentive calculation using the same process, based on the winter performance rate. For Construct 5 customers, the winter performance rate is equal to 11% of the approved Performance Rate. If the participant in the example participates, as expected, at 5 kW for all winter events the Standard incentive would be calculated as: $25/kW x 5 kW = $125 (Legacy) or $300/kW x 5kW x 11% = $165 (Construct 5). Over the course of both seasons this participant was able to earn $875 + $125 = $1,000 (Legacy) or $1,168 + $165 = $1,333 (Construct 5) in Active Dispatch performance incentives for the year. The calculation of incentive benefit specified here is subject to change by the Program Administrators (with PURA’s approval) and will be indicated on the Program website, customer enrollment forms and other Program materials. 6.7. Incentive Payment Process Sec 6.7 applies to both Legacy Program customers and Construct 5 Customers. CGB will administer all upfront or enrollment payment following the approval of the Application, an inspection (if opted-in) or self-inspection of the system’s installation at the discretion of the Program Administrators, and the provision of proof of enrollment in both Active and Passive Dispatch (where applicable) portions of Energy Storage Solutions. The relevant EDC will administer the incentive payments for summer and winter performance, as calculated in the “Incentive Rates and Average Performance” section. For legacy Passive Dispatch customers, the relevant EDC will issue the seasonal Active Performance payment after Passive Claw Back amounts are finalized and subtracted from the Active Performance payment due. New Construct 5 Customers or Legacy Passive Dispatch whose clawback obligations have been fully met will typically be paid within 6-8 weeks of the conclusion of the dispatch season. Upfront and Enrollment Incentive Payments Upfront and Enrollment incentives are provided as upfront discounts reflected in the customer’s purchase or lease agreement with their Contractor or TPO. CGB will disburse upfront incentive reimbursements to eligible Contractors or TPOs as indicated on the Application. After incentive Reservation and once the system is installed and energized, Contractors and TPOs shall submit proof of project completion and interconnection through the Customer Enrollment Platform. Once verified by CGB that installation was performed in accordance with the original or 63Page 65 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 65 of 203 amended incentive application, all completion documentation has been submitted and approved, Passive Dispatch enrollment has been verified (where applicable), and all applicable Program requirements have been met, the project will be eligible to have the Upfront or Enrollment Incentive reimbursed to the Contractor or TPO. CGB will process incentive payments to Contractors and TPOs in monthly batches. If a battery system is not installed properly or in accordance with the proposed system specifications submitted to the Program Administrators, CGB reserves the right to withhold or recalculate Upfront or Enrollment incentive payments based on actual installed equipment and site conditions. Additionally, the Program Administrators may stop approving incentive applications and/or withhold payments for Contractors and TPOs that consistently have problems properly installing BESS and/or complying with the requirements of Energy Storage Solutions. Additional information regarding Upfront and Enrollment Incentive payments will be made available by the Program Administrators in a separate document on the Energy Storage Solutions website. Performance Incentive Data and Payments Performance incentives will be calculated in accordance with Section 6.3. and paid by the EDCs following the Summer and Winter seasons for all customers enrolled prior to April 1, 2026. The relevant EDC will administer the incentive payments for summer and winter performance, as calculated in the “Incentive Rates and Average Performance” section. For legacy Passive Dispatch customers, the relevant EDC will issue the seasonal payment after Passive Claw Back amounts are finalized and subtracted from the Active Performance payment due. New Construct 5 Customers or Legacy Passive Dispatch whose clawback obligations have been fully met will typically be paid within two months of the conclusion of the dispatch season Customers enrolling on or after April 1, 2026 will have the option to receive their performance incentive payments either annually or biannually at the point of program application. Customers who select the annual payment option will receive a single payment that combines both the winter and summer performance incentives. This payment will be issued within two months of the conclusion of the summer dispatch season. Customers who select the biannual payment option will receive two separate payments: one for the winter dispatch season and one for the summer dispatch season. Each payment will be issued within two months after the respective dispatch season concludes. The incentive rates are 11% ($33/kW for Residential standard) for the winter dispatch season, and 89% ($267/kW for Residential standard) for the summer dispatch season. To enhance data transparency and support Program enrollment, the Program Administrators must provide all available Active and Passive Dispatch performance data to ESS customers upon request, within 90 days after the end of a dispatch season after a data request is made. Direct Payments Battery storage owners will have access to direct payment options, which will support PURA’s key Program objectives, including facilitating deployment of battery storage in LMI and vulnerable communities, while at the same time reducing risk to homeowners and capital providers and lowering system financing costs. 64Page 66 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 66 of 203 Customers can designate a direct payment payee at the time of enrollment, and EDCs will assign performance incentive payments in part of in full to a TPO, vendor, financial institution, or other party as specified by the Customer. Customer must complete a Direct Payment Beneficiary Form, available in Appendix G or at energystorageCT.com/contractor-resources. 6.8. Days for Dispatch Events Sec 6.8 applies to both Legacy Program customers and Construct 5 Customers. Active discharge events are called on weekends, weekdays, or holidays – for both summer and winter. Passive discharge events are limited to non-holiday weekdays during the Summer season (June, July and August) only. Holidays excluded from Passive Dispatch events include: Table 18: Holidays for Passive Dispatch Events Dispatch Season Summer Holiday Independence Day Typical Date July 4 Summer Juneteenth June 19 6.9. No Demand Response Events Before Large Storms Sec 6.9 applies to both Legacy Program customers and Construct 5 Customers. Customers often purchase energy storage systems in part for backup power during power outages. Under non-storm operating scenarios, no more than 80 percent of available energy capacity will be used during Passive events, leaving 20 percent available for backup power. The EDCs will cancel events (Active or Passive) for the two (2) days preceding any predicted Emergency Restoration Plan level (level 1-5) outage events, leaving the customer to use the BESS as the customer deems appropriate. 6.10. Performance Testing Sec 6.10 applies to both Legacy Program customers and Construct 5 Customers. The Program Administrators may conduct performance tests of the BESS during installation or during periodic inspections (if opted-in). However, the Program Administrators may periodically elect to run communication tests to ensure all notification processes are functioning. A BESS Commissioning & Acceptance Testing program that will ensure that system perform as designed and that the system meets the Technical Requirements and performs as expected. Commissioning documentation typically includes but is not limited to: Electrical Design verification Certificates of Code Compliance Power/Energy Capability testing 65Page 67 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 67 of 203 Modes of Operation testing in Local/Remote Control Functional acceptance testing of fire detection and suppression Network Integration and SCADA point verification First Responder orientation record BESS OEMs, Operators, and Aggregators may work with CGB, the EDCs, and the Program’s DERMS providers, if necessary, to call up to two Passive Dispatch test events per year. Participation in these test events shall be optional and not affect the Upfront Incentive Claw Back provisions detailed in Section 6. Remainder of this page intentionally left blank 66Page 68 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 68 of 203 Section 7: Storage Configuration Considerations 7.1. Co-Participation in ISO-NE Market Programs Residential, commercial, and industrial customers and/or the corresponding TPO will be able retain capacity rights without the ability to monetize such rights (i.e., participation in the ISO-NE FCM) as the default Program arrangement. However, for projects that applied for enrollment in ESS prior to January 1, 2023 and met one of four criteria as a Priority Customer at the time of application, TPOs and C&I customers were permitted to request capacity rights in order to monetize storage assets into ISO-NE market programs. Customers who are participating in ISO-NE at the same facility but not through the storage assets supported by Energy Storage Solutions (traditional curtailment) will still retain the rights to that capacity. Energy storage system operators with capacity rights must adopt the Passive Dispatch settings established pursuant to the Authority’s final decision. However, they may operate outside the Passive Dispatch parameters to meet ISO-NE market obligations if they meet all requirements established by the operational control model. Projects that do not participate in an Active demand response event will not receive the corresponding performance incentive. 7.2. ISO-NE Market Participation Verification Process During the incentive application process, customers must inform Program Administrators of their intent to participate in the ISO-NE Forward Capacity Market (FCM) and/or ancillary services market. Customers wishing to participate in ISO-NE markets must apply for eligibility at the time of application. BESS participating in Energy Storage Solutions may participate in ISO-NE ancillary services market that allow participation by load reducers for the purposes of developing the load forecast used in calculating the Installed Capacity Requirement. Accordingly, such projects shall operate under the Passive Dispatch settings to the furthest possible extent but can override the baseline settings in order to satisfy any ISO-NE market requirements. Following each Passive and Active Dispatch season, individual battery owners or battery aggregators participating in FCM or ancillary services market, must submit a self-certification stating (1) whether they participated in ISO-NE markets, 2.) which market(s) they participated in, (3) the days and hours of such participation, (4) the compensation received for each event; and (5) whether the compensation is from a third-party aggregator or directly from the market net of administrative fees. Program Administrators will work with EM&V Provider to confirm ISO-NE market participation by these assets, and the level of their participation, in order to better understand how such participation impacts the expected Program benefit-cost ratios and any implications for the Program’s Active and Passive Dispatch settings. 7.3. Monetization of Capacity Rights Only project owners as specified in Section 7.1 can monetize capacity rights in the ISO-New England Forward Capacity Markets via Forward Capacity Auctions (FCA), Annual Reconfiguration Auctions (ARA) or Monthly Reconfiguration Auctions (MRA). 67Page 69 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 69 of 203 To ensure that the ratepayer benefits that the Authority is seeking are achieved (i.e., RIM≥1.4 for the Program), the Program Administrators will monitor FCM participation based on the total capacity of systems that qualify for ISO-NE market participation at the time of enrollment. If greater than 25% of systems eligible to participate in the FCM opt to monetize capacity rights, the Program Administrators will notify the Authority. The 25% benchmark will be calculated annually based on the total MW of systems eligible to participate in ISO-NE markets divided by the total MW deployed in Energy Storage Solutions. At the completion of the first year of the program, and every subsequent year, Program Administrators will evaluate customers participation in ISO-NE markets, its impact on the program RIM, and the suitability of this benchmark. Program Administrators will develop an ISO-NE market participation verification process to better understand how such participation impacts the expected Program benefit-cost ratios and any implications for the Program’s Active and Passive Dispatch settings, and its findings will be incorporated in Program annual reports. 7.4. Storage Configurations & Interconnection 7.4.1. Renewable Energy Plus Storage Customers with interconnected renewable energy systems, such as solar photovoltaics and wind turbines, may participate in Energy Storage Solutions. The investment tax credit (ITC), also known as the federal solar tax credit, may provide added incentives for energy storage systems charged by renewable energy systems. Consult a tax professional with any additional questions. The battery system’s performance will be limited by the terms and conditions established in the approved interconnection agreement. 7.4.2. Storage Only Systems Customers who do not have a renewable energy system but do have an energy storage system that charges from the grid may participate in Energy Storage Solutions. If the system will be running in parallel to the grid, it must go through the normal interconnection process with the relevant EDC. The battery system’s performance will be limited by the terms and conditions established in the approved interconnection agreement. Remainder of this page intentionally left blank 68Page 70 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 70 of 203 Section 8: System Disposal 8.1 Eligible Contractor and Third-Party Owner Responsibilities The decommissioning of any BESS participating in Energy Storage Solutions shall be completed by the Contractor, TPO, or another party as designed by the Contractor or TPO. The Contractor or TPO shall be held responsible by the Program Administrators for ensuring that all appropriate steps have been taken to dispose of and recycle all BESS components in such a manner that minimizes waste and environmental harm in compliance with all local, state, and federal regulations. Remainder of this page intentionally left blank 69Page 71 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 71 of 203 Appendix A: Eligible Equipment List The most current Eligible Equipment List is available at https://energystoragect.com/submitted_ess_system_status_list/. All new applicants must submit a New Technology Application (Appendix C) to be reviewed and approved by the Program Administrators to be added to the Eligible Equipment List. The BESS equipment will be approved once the New Technology Application has been reviewed and approved, and the equipment manufacturer and/or BESS Operator or Aggregator has signed a Scope of Work, including a plan of integration, with the respective Distributed Energy Resource Management System (DERMS) provider. Final Approval of equipment is contingent upon completing integration with the respective DERMS. 70
Text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
Extracted from the file · 2 pages · 6,256 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
Extracted from the file · 2 pages · 3,261 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
Extracted from the file · 1 page · 528 characters
Text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Extracted from the file · 2 pages · 4,800 characters
As listed on the current system
Compliance Filings, 11/16/2026 [26-08-01] Order No.1 / Avangrid / 5. Annual Compliance Filings – Additional Filings (Program Materials)