Compliance Filing, Order No. 1
5. Annual Compliance Filings – Additional Filings (Program Materials)
Files13
2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
PDF · 221 KB · 3 pagesText searchable
Download 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdfRead the text of 2026-11-16 UI Cover Letter 5. Annual Compliance Filings – Additional Filings (Program Materials) #26-08-01.pdf
2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
PDF · 763 KB · 59 pagesText searchable
Download 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 1 - Residential Renewable Energy Solutions Program Manual #26-08-01.pdf
2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
PDF · 1.7 MB · 100 pagesText searchable
Download 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 2 - Non-Residential Renewable Energy Solutions Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
PDF · 2.9 MB · 147 pagesText searchable
Download 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
PDF · 4.4 MB · 203 pagesText searchable
Download 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 4 - ESS Program Materials #26-08-01.pdf
2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
PDF · 115 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
PDF · 159 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Excel · 100 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Excel · 272 KBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Excel · 3.5 MBText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
PDF · 144 KB · 1 pageText searchable
Download 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Excel · 71 KBText searchable
Download 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsxRead the text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
PDF · 152 KB · 2 pagesText searchable
Download 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdfRead the text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Text of 2026-11-16 UI Attachment 3 - Shared Clean Energy Facility Program Program Materials #26-08-01.pdf
Extracted from the file · 147 pages · 342,741 characters
Page 97 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 97 of 203 Section 2 – Applicant (Required) APPLICANT COMPANY INFORMATION Applicant Company Name Applicant Contact Name Applicant Company Address Street, City, State, Zip Contact Phone Target Customer Class Contact Email ☐ Residential ☐ Commercial & Industrial (C&I) ☐ Both What is Applicant Company’s role in deploying BESS? (Select all that apply) ☐ BESS Aggregator ☐ BESS Operator ☐ BESS OEM ☐ Inverter OEM ☐ Battery OEM ☐ Other (describe) Other role: Applicant Company Description 96Page 98 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 98 of 203 Section 3 – BESS Equipment (not required for BESS Aggregators) Note: If you are applying for a BESS with multiple size or inverter configurations, all configurations must be included under the same UL 9540 listing. If any configuration is part of another UL 9540 listing, you must submit separate applications for those configurations. Complete the section below for the battery portion of the BESS. BATTERY INFORMATION Battery Manufacturer Company Name Contact Name Contact Email Contact Phone Battery Model(s) Battery Nameplate Power (kW) Battery Nameplate Energy Capacity (kWh) Battery Maximum Continuous Discharge Rate (kW) Battery Nominal Voltage (VAC) Battery Round Trip Efficiency (%) Battery Warranty Term (Years) Battery model(s) certified to UL 1973? ☐ Yes ☐ No If no, expected date: Battery model(s) commercially available? ☐ Yes ☐ No If no, expected date Additional notes (if applicable) 97Page 99 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 99 of 203 Complete the section below for the inverter portion of the BESS. INVERTER INFORMATION Inverter and Battery are integrated as a single model Inverter Manufacturer Company Name Contact Name Contact Email Contact Phone Inverter Model(s) ☐ Yes ☐ No Inverter Nameplate Power (kW) Inverter Phase ☐ Single Phase Inverter Output Voltage (V) Inverter Maximum Continuous Current (A) Inverter Maximum Continuous Power (VA) Inverter Warranty Term (Years) Inverter model(s) received UL ☐ Yes ☐ 1741 SA? No Inverter model(s) commercially ☐ Yes ☐ available? No If no, expected date: If no, expected date: ☐ Multi Phase Additional notes (if applicable) 98Page 100 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 100 of 203 Complete the section below for the BESS. The BESS is defined as the combination of the above Battery(s) and Inverter(s). UL 9540 Certification is required for any BESS being installed after the CT Department of Administrative Services adopted the 2021 International Fire Code.55 BESS INFORMATION ☐ Yes BESS is certified to UL 9540? ☐ No If no, please explain reason and estimated timeline for UL 9540 certification: Section 4 – BESS Operator or Aggregator and DERMS Communication (Required) Provide information about the BESS Operator or Aggregator by completing the section below. The BESS Operator is the entity responsible for connecting the BESS equipment to the relevant DERMS provider. The BESS Aggregator is the entity responsible for the coordination of BESS participating in Active Dispatch events within the Program, working as an intermediary between the DERMS and the BESS Operator. The BESS Operator is often the inverter manufacturer but can also be a third-party integrator such as a developer or owner-operator. If the Applicant Company only manufactures batteries and the BESS utilizes an inverter made by a different company, you may need to coordinate with the inverter manufacturer to complete this section. This section will determine if the BESS: 1. Is capable of transmitting data to its respective DERMS platform, 2. Can meet Passive Dispatch requirements, and 3. Meets UL 9540 safety certification requirements. BESS OPERATOR INFORMATION BESS Operator or Aggregator Company Name Contact Name Contact Email Please list all complete DERMS integrations Communication Protocol Ex: EnergyHub Ex: OpenADR Battery Energy Storage Systems which passed all inspection requirements prior to the adoption of the 2021 International Fire Code do not require UL 9540 Certification. 55 99Page 101 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Does BESS Operator, Aggregator, or other party charge a Vendor Fee56? ☐ Yes Page 101 of 203 ☐ No If yes, describe fee and structure: COMMUNICATION CRITERIA 1. Can the BESS Operator or Aggregator receive a control signal from a DERMS and pass that control signal to the BESS at the customer site? 2. Can the BESS Operator or Aggregator communicate customer name, site address, utility account number, battery OEM, device universal unique identifier (UUID), and BESS kW and kWh capacities? 3. As part of the control signal, can the BESS Operator or Aggregator communicate start time, end time, and magnitude of discharge on a per-event basis for each BESS? 4. Does BESS Operator or Aggregator offer an outage protection mode? (i.e., mode that prevents the battery from discharging in anticipation of a severe weather event or outage possibility?) 5. 56 ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No If you answered Yes to 4 above, describe outage protection mode: See definition in Section 6 – Glossary of Terms 100Page 102 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 102 of 203 6. If you answered Yes to 4 above, can the BESS Operator or Aggregator communicate information about individual instances of BESSs entering an outage protection mode to the DERMS? If yes, describe: 7. Can the system dispatch and cancel/override an event if it receives notification from a DERMS provider? ☐ Yes ☐ No ☐ Yes ☐ No 8. Is the BESS Operator or Aggregator willing to commit to developing and maintaining 9. a communication pathway at their own expense to the DERMS platform through an API integration? Is the BESS Operator or Aggregator capable of integrating using Open ADR Protocol? ☐ Yes ☐ No ☐ N/A 10. If you answered No to 9 above, describe the resources you have available to commit to integration with the applicable DERMS, along with estimated timeline for integration: 101Page 103 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 103 of 203 TELEMETRY REQUIREMENTS 1. Does the BESS Operator or Aggregator maintain cloud storage of telemetry data? ☐ Yes ☐ No If so, describe: 2. 3. At what interval does the BESS Operator or Aggregator maintain telemetry data? (i.e. 15 minutes, 1 hour, 1 day, etc.). The Program requires a 15minute interval. At what latency does the BESS Operator or Aggregator communicate telemetry data with the DERMS? (i.e. 15 minutes, 1 hour, 1 day, etc.). The Program requires a one-month latency, at most. Additional notes on telemetry (if applicable): 102Page 104 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 104 of 203 Passive Dispatch is a requirement of the Program for customers receiving upfront incentives. The BESS Operator will be responsible for meeting the Passive Dispatch criteria. Note that Passive Dispatch and the associated upfront incentives will no longer be available after April 1st, 2026. SCHEDULING REQUIREMENTS - PASSIVE DISPATCH 1. BESS can be pre-programmed by BESS Operator to discharge to 20% rated capacity Monday through Friday (except holidays) during the months of June, July, and August uniformly between the hours of 5PM and 8PM. ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No If no, describe: 2. The BESS Operator will ensure BESS discharge is regulated to an even discharge over those 3 Passive Dispatch hours (Available capacity – 20% of nameplate capacity)/3. If no, describe: 3. BESS Operator can override Passive Dispatch events for BESS when Active Dispatch events are requested for those scheduled days or when requested by DERMS due to forecasted severe weather. If no, describe: Section 5 – Application Submission WHAT HAPPENS NEXT? 1. After the Application and supporting documents (UL Certifications and Product Specification Sheets) are submitted, you will receive an email confirmation including an application number (NTA-####). 2. The Program Administrators will request additional information, if necessary, and/or inform you of the decision, along with comments, to approve or deny the BESS in the Program. 3. Application resubmittal guidelines are stated in the Program Guidelines for Energy Storage Solutions. Contact [email removed] with any questions or concerns. 103Page 105 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 105 of 203 104Page 106 of 203
The United Illuminating Company Docket No. 26-08-01 UI Attachment 5 ESS Program Manual and Additional Information Page 106 of 203 Section 6 – Glossary of Terms TERM DEFINITION Active Dispatch Events where a BESS dispatches energy to reduce demand during summer and winter peak periods as determined by the EDCs based on anticipated grid demand. Active Dispatch events are typically scheduled day-ahead. API Application Programming Interface, which is a software intermediary that allows two applications to talk to each other Eligible Equipment List The Eligible Equipment List includes equipment that has been submitted to be included in the Energy Storage Solutions program. Final approval requires the equipment to be fully of integrated with the respective DERMS platform (residential and/or commercial) BESS Battery Energy Storage System: electrical, electrochemical, mechanical and other types of energy storage technologies for systems intended to supply electrical energy. Includes battery and inverter for the purposes of this Program. BESS Aggregator Entity responsible for the coordination of BESS participating in Active Dispatch events within the Program, working as an intermediary between the DERMS and the BESS Operator. Eligible BESS Aggregators will aggregate and enroll Eligible BESS into the Active Dispatch portion of the Program for qualified customers. BESS Operator Entity responsible for the coordination of the BESS participating in dispatch events within the Program DERMS The “Distributed Resource Energy Management System” is the platform utilized by the Electric Distribution Companies to notify the Battery Operators of scheduled events requiring Battery Energy Storage System actions. EDCs Electric Distribution Companies (Eversource Energy and The United Illuminating) OpenADR Open Automated Demand Response, provides a non-proprietary, open standardized demand response interface that allows electricity providers to communicate demand response signals directly to existing customers using a common language and existing communications Passive Dispatch Events where a BESS dispatches energy to reduce demand during summer peak periods. Passive Dispatch events are pre-scheduled by the Program Administrators and BESS Operators must program this event schedule into the BESS. See energystorageCT.com for complete schedule. Program Energy Storage Solutions is a program offered through the Program Administrators Program Administrators Collectively the Connecticut Green Bank, Eversource Energy, and The United Illuminating Company 105
Text of 2026-11-16 UI Attachment 5 - EV Program Materials and Additional Information #26-08-01.pdf
Extracted from the file · 2 pages · 6,256 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report - Cover Ltr #26-08-01.pdf
Extracted from the file · 2 pages · 3,261 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit A #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit B C and D #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit E #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out · first 300,000 characters
Text of 2026-11-16 UI Attachment 6 - Annual RPS Compliance Report RPS Template Exhibit F #26-08-01.pdf
Extracted from the file · 1 page · 528 characters
Text of 2026-11-16 UI Attachment 7 - Exhibit Y Ten Year Cost History - BETP-001 #26-08-01.xlsx
Sheet names, column headings and text cells; numbers left out
Text of 2026-11-16 UI Attachment 8 - CEOP-VRO Program Materials #26-08-01.pdf
Extracted from the file · 2 pages · 4,800 characters
As listed on the current system
Compliance Filings, 11/16/2026 [26-08-01] Order No.1 / Avangrid / 5. Annual Compliance Filings – Additional Filings (Program Materials)