Skip to main content

A prototype public docket site for the Connecticut Public Utilities Regulatory Authority

Utility Dockets and Filings

Compliance Filing

ES Annual Compliance Filing Orders 1 and 2

Compliance filingFiled by Eversource Energy47 files
Part of docket 26-08-01Open
  • Electric
2026 Clean and Renewable Energy Program Data and Report

Files47

Search terms highlighted
Eversource rate increase is on 33 pages across 8 files of the text below, highlighted. Go to the first matchClear highlighting
Words on different pages
Words on different pages
Words on different pages

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 2.pdf

Extracted from the file · 1 page · 8,665 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 1.pdf

Extracted from the file · 6 pages · 27,557 characters

4 pages match
  1. Page 41 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 41 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Table 4-1 Program Evaluation Metrics by Active Event Date – Summer Season Event Date1 Maximum Expected Average Battery Power based Energy Battery Average on Energy Average Energy Power per Availability Power per Number of Active Event Availability Eligible Participation (kWh/ Availability Event (kW/ (kW/ Event (kW/ Participants (%)2 Participant) (kWh/Event) Program) Participant)3 Participant) % of Maximum Expected Power per Event (%)4 9/16/2022 9/22/2022 9/28/2022 1 1 1 100% 100% 100% 17 17 17 17 17 17 3.9 4.0 3.9 5.7 5.7 5.7 3.9 4.0 3.9 69% 70% 69% Summer 2022 Average 1.0 100% 17 17 3.9 5.7 3.9 69% 7/3/2023 7/5/2023 7/6/2023 7/7/2023 7/8/2023 7/11/2023 7/12/2023 7/13/2023 7/14/2023 7/15/2023 7/17/2023 7/18/2023 7/19/2023 7/20/2023 7/24/2023 7/25/2023 7/26/2023 7/27/2023 7/28/2023 7/29/2023 8/8/2023 8/9/2023 8/10/2023 8/14/2023 8/21/2023 8/22/2023 8/30/2023 9/5/2023 9/6/2023 9/7/2023 32 37 37 37 37 37 37 36 36 36 32 37 37 37 31 36 37 32 37 32 50 50 49 54 55 6 64 6 64 64 78% 78% 81% 78% 76% 65% 70% 61% 67% 67% 66% 62% 70% 76% 90% 67% 62% 62% 59% 62% 82% 84% 78% 81% 73% 50% 89% 67% 66% 67% 17 16 16 15 16 16 15 16 16 16 17 16 15 17 17 17 17 16 16 17 15 16 16 14 16 14 15 12 16 15 529 589 598 571 581 599 569 570 569 591 538 601 571 615 514 601 618 517 604 551 757 794 760 759 863 82 956 73 1004 969 87 88 119 95 88 83 96 89 93 116 108 119 113 134 105 124 122 76 101 104 162 174 161 195 195 15 242 17 201 153 5.7 5.3 5.3 5.0 5.3 5.3 5.0 5.3 4.0 8.0 8.5 8.0 7.5 8.5 5.7 8.5 8.5 5.3 8.0 8.5 7.5 8.0 8.0 7.0 8.0 7.0 7.5 6.0 8.0 5.0 2.7 2.4 3.2 2.6 2.4 2.2 2.6 2.5 2.6 3.2 3.4 3.2 3.1 3.6 3.4 3.5 3.3 2.4 2.7 3.3 3.3 3.5 3.3 3.6 3.5 2.6 3.8 2.8 3.1 2.4 48% 45% 60% 51% 44% 42% 52% 46% 65% 40% 40% 40% 41% 43% 60% 41% 39% 45% 34% 38% 43% 44% 41% 52% 44% 37% 50% 47% 39% 48% Summer 2023 Average 39 71% 16 617 119 6.8 3.0 45% Overall Average 36 74% 16 563 109 6.7 3.1 47% Information for the sole benefit and use of Connecticut Green Bank Page 37
  2. Page 42 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 42 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report 1. All rows given for the summer season represent averages across each active event within the 2022-2023 seasons. Summer season events are July through September. Events are EDC-specific and may or may not overlap. This difference in event schedule results in some events with a lower number of participants due to not all Program batteries being called. 2. Participation (%) is defined as the share of devices with an average dispatch less than zero (dispatching energy more than charging energy) during the event window divided by the count of devices enrolled at the time of the event. 3. Calculated as Battery Energy Availability per participant divided by the length of the event, which was three hours for every event evaluated. Note that the listed values may exceed the maximum achievable power of participating energy storage systems. 4. Calculated as Average Power per Event divided by Maximum Expected Average Power based on Energy Availability. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-2. Program Evaluation Metrics by Active Event Date – Winter Season Event Date1 Battery Energy Battery Energy Number of Active Event Availability Eligible Participation (kWh/ Availability Participants (%)2 Participant) (kWh/event) Maximum Expected Average Power based Average on Energy Average Power per Availability Power per Event (kW/ (kW/ Event (kW/ Program) Participant)3 Participant) % of Maximum Expected Power per Event (%)4 2/4/20235 3/7/20235 3/24/20235 4 5 6 75% 80% 83% 25 23 21 99 117 126 13.8 14.8 15.8 8.3 7.7 7.0 3.4 3.0 2.6 41% 38% 37% Winter 2023 Average 5 79% 23 114 15 7.7 3.0 39% 1/17/2024 1/19/2024 3/21/2024 104 96 125 79% 65% 94% 13 9 15 1380 888 1829 212 94 334 4.3 3.0 5.0 2.0 1.0 2.7 47% 32% 53% Winter 2024 Average 108 79% 12 1366 213 4.1 1.9 44% Overall Average 57 79% 18 740 114 5.9 2.4 41% 1. All rows given for the winter season represent averages across each active event within the 2023-2024 season. Winter season events are November through March. Events are EDC-specific and may or may not overlap. This difference in event schedule results in some events with a lower number of participants due to not all Program batteries being called. 2. Participation (%) is defined as the share of devices with an average dispatch less than zero (dispatching energy more than charging energy) during the event window divided by the count of devices enrolled at the time of the event. 3. Calculated as Battery Energy Availability per participant divided by the length of the event, which was three hours for every event evaluated. Note that the listed values may exceed the maximum achievable power of participating energy storage systems. 4. Calculated as Average Power per Event divided by Maximum Expected Average Power based on Energy Availability. 5. A subset of OEM-specific batteries were enrolled during the 2023 winter season, but not called for events, and were enrolled as a small test group. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-3 displays the same performance metrics for active events exclusively for the single C&I system for which data was available. The C&I device enrolled late in the summer 2023 season, with only the opportunity to participate in two events, which it did not to any significant degree. However, the device did participate more significantly for the three winter events, dispatching 40% of its maximum expected power as opposed to the 2% dispatched in summer 2023. Information for the sole benefit and use of Connecticut Green Bank Page 38
  3. Page 43 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 43 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Table 4-3. Program Evaluation Metrics by Active Event Date – C&I Event Date1 Battery Energy Battery Energy Number of Active Event Availability Eligible Participation (kWh/ Availability 2 Participants (%) Participant) (kWh/Event) Maximum Expected Average Power based Average on Energy Average Power per Availability Power per Event (kW/ (kW/ Event (kW/ Program) Participant)2 Participant) % of Maximum Expected Power per Event (%)3 9/6/2023 9/7/2023 1 1 100% 100% 660 660 660 660 2.92 3.92 125 125 2.92 3.92 1% 2% Summer2023 Average 1 100% 660 660 3.4 125 3.4 2% 1/17/2024 1/19/2024 3/21/2024 1 1 1 100% 100% 100% 660 660 660 660 660 660 102.64 30.97 77.86 125 125 125 103 31 78 58% 18% 44% Winter2024 Average 1 100% 660 660 70.49 125 70 40% Overall Average 1 100% 660 660 43.662 125 44 25% 1. All rows given for the winter season represent averages across each active event within the 2023-2024 season. Winter season events are November through March. Events are EDC-specific and may or may not overlap. This difference in event schedule results in some events with a lower number of participants due to not all Program batteries being called. 2. Calculated as Battery Energy Availability per participant divided by the length of the event, which was three hours for every event evaluated. Note that the listed values may exceed the maximum achievable power of participating energy storage systems. Due to data availability, availability is given as the nameplate capacity (kWh) as opposed to the energy stored at the start of the event. 3. Calculated as Average Power per Event divided by Maximum Expected Average Power based on Energy Availability. Due to the single device’s nameplate capacity (kW) being less than 1/3 of the nameplate kWh, the maximum expected average power is based on nameplate capacity (kW). Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-4 displays performance metrics for all passive events. Participation fluctuated significantly during the summer season, reaching as high as 95% and as low as 40% around an average of 75%. Power dispatched was similarly fluid, with an average of 53% of maximum power dispatched per event, slightly higher than the average power dispatched during active events. Information for the sole benefit and use of Connecticut Green Bank Page 39
  4. Page 44 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 44 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Table 4-4 Program Evaluation Metrics by Passive Event Date – Summer Season Battery Energy Number of Passive Event Availability Eligible Participation (kWh/ (%)2 Participant) Event Date1 Participants 6/1/2023 6/2/2023 6/5/2023 6/6/2023 6/7/2023 6/8/2023 6/9/2023 6/12/2023 6/13/2023 6/14/2023 6/15/2023 6/16/2023 6/19/2023 6/20/2023 6/21/2023 6/22/2023 6/23/2023 6/26/2023 6/27/2023 6/28/2023 6/29/2023 6/30/2023 7/3/2023 7/10/2023 7/17/2023 7/21/2023 7/24/2023 7/27/2023 7/31/2023 8/1/2023 8/2/2023 8/3/2023 8/4/2023 8/7/2023 8/11/2023 8/14/2023 8/15/2023 8/16/2023 8/17/2023 8/18/2023 8/21/2023 8/22/2023 20 20 22 22 26 26 26 26 29 29 29 29 28 29 29 29 33 32 33 33 33 33 5 37 5 36 5 5 37 49 50 50 50 50 60 6 60 61 61 61 6 55 75% 85% 91% 95% 85% 85% 92% 88% 86% 90% 79% 93% 50% 93% 83% 86% 91% 91% 91% 88% 82% 91% 80% 76% 60% 86% 80% 40% 95% 61% 70% 74% 74% 70% 50% 50% 58% 56% 72% 59% 50% 64% 18 18 16 17 16 16 16 16 15 15 16 16 16 16 16 16 16 15 14 14 16 16 14 15 12 15 14 12 16 17 16 15 13 13 16 14 12 13 12 16 13 16 Battery Energy Availability (kWh/Event) Maximum Expected Average Average Power Power based per on Energy Event % of Maximum (kW/ Expected Average Power Availability per Event (kW/ (kW/ Particip Power per 3 Program) Participant) ant) Event (%)4 363 364 357 370 418 424 420 423 444 444 457 466 458 464 463 453 523 492 455 475 516 518 68 568 60 558 68 62 587 812 809 755 674 646 938 82 708 771 762 957 79 890 Information for the sole benefit and use of Connecticut Green Bank 34.8 41.6 42.1 42.0 50.9 47.2 47.4 50.0 50.8 57.3 51.7 56.6 9.2 62.0 57.1 55.2 69.0 65.4 62.2 54.1 58.3 62.7 8.3 56.6 7.3 73.2 8.6 4.3 95.0 54.2 88.1 92.6 68.4 59.8 30.6 6.9 34.5 44.6 71.3 72.0 6.3 83.3 3.6 3.6 3.2 3.4 3.2 3.2 3.2 3.2 3.0 3.0 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.0 2.8 2.8 3.2 3.2 2.8 3.0 2.4 3.0 2.8 2.4 3.2 3.4 3.2 3.0 2.6 2.6 3.2 2.8 2.4 2.6 2.4 3.2 2.6 3.2 1.74 2.08 1.92 1.91 1.96 1.81 1.82 1.92 1.75 1.98 1.78 1.95 0.33 2.14 1.97 1.90 2.09 2.04 1.89 1.64 1.77 1.90 1.65 1.53 1.46 2.03 1.71 0.85 2.57 1.11 1.76 1.85 1.37 1.20 0.51 1.14 0.57 0.73 1.17 1.18 1.05 1.51 48% 58% 60% 56% 61% 57% 57% 60% 58% 66% 56% 61% 10% 67% 62% 59% 65% 68% 68% 59% 55% 59% 59% 51% 61% 68% 61% 35% 80% 33% 55% 62% 53% 46% 16% 41% 24% 28% 49% 37% 40% 47% Page 40
  5. Page 45 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 45 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Battery Energy Number of Passive Event Availability Eligible Participation (kWh/ (%)2 Participant) Event Date1 Participants Battery Energy Availability (kWh/Event) Maximum Expected Average Average Power Power based per on Energy Event % of Maximum (kW/ Expected Average Power Availability per Event (kW/ (kW/ Particip Power per Program) Participant)3 ant) Event (%)4 8/23/2023 8/24/2023 8/25/2023 8/28/2023 8/29/2023 8/31/2023 61 62 64 64 64 64 62% 61% 83% 83% 86% 69% 14 13 11 14 13 16 826 825 696 885 837 1006 95.0 64.9 59.6 128.1 113.0 74.8 2.8 2.6 2.2 2.8 2.6 3.2 1.56 1.05 0.93 2.00 1.77 1.17 56% 40% 42% 71% 68% 37% Overall Average 36 76% 15 535 55 3.0 1.6 53% 1. All rows given for the passive season represent averages across each passive event within the 2023 summer season. Summer passive season events are June through August. Events are EDC-specific and may or may not overlap. This difference in event schedule results in some events with a lower number of participants due to not all program batteries being called. 2. Participation (%) is defined as the share of devices with an average dispatch less than zero (dispatching energy more than charging energy) during the event window divided by the count of devices enrolled at the time of the event. 3.. Calculated as Battery Energy Availability per participant divided by the length of the event, which was three hours for every event evaluated. Note that the listed values may exceed the maximum achievable power of participating energy storage systems. 4.. Calculated as Average Power per Event divided by Maximum Expected Average Power based on Energy Availability. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-5 displays the program evaluation metrics by the seasonal peak event, as well as both summer and winter peak hours. The single seasonal (and annual) peak in 2022 occurred before the first ESS active event was called; however, in 2023, an active event was called during the 2023 ISO-NE Peak Hour, resulting in 186 kW of peak reduction. Two active events in summer 2023 were called during the summer peak period, while two active events in winter 2024 were called during the winter peak period (with peak period as defined in Table 4-5). In both cases, average power per event was less than the program-wide average power per event. Table 4-5 also shows that the passive dispatch window was able to generate an average reduction of 1.6 kW per participant during times in which an active event was not called, resulting in overall program peak reduction of 1.7 kW during active or passive events called during the summer peak period. Additionally, the passive and active windows combined to overlap with 61 days’ peak hours, resulting in an average program dispatch of 55 kW across all June-August peak hours, irrespective of if a passive or active event was concurrent with each peak hour. Dispatch during the winter period was roughly commensurate with summer Information for the sole benefit and use of Connecticut Green Bank Page 41
  6. Page 46 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 46 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report performance; however, total winter dispatch (i.e., not filtered to only event windows) was very limited due to fewer active events called and no passive dispatch. Table 4-5. Evaluation Metrics by Seasonal Peak Event Average Power per Participant (kW) Average Power per Program (kW) Dates (#) 2022 ISO-NE Peak Hour (August 8, 2022, 3 p.m.-4 p.m. ET) N/A N/A 1 2023 ISO-NE Peak Hour (September 7, 2023, 5 p.m.-6 p.m. ET) 2.9 186 1 Active Dispatch during Summer Peak Period (non-holiday weekdays 1 p.m.-5 p.m. ET, June-August) 2.5 83 2 Passive Dispatch during Summer Peak Period (non-holiday weekdays 1 p.m.-5 p.m. ET, June-August) 1.6 118 48 Active or Passive Dispatch during Summer Peak Period (non-holiday weekdays 1 p.m.-5 p.m. ET, June-August) 1.7 119 49 Active Dispatch during Summer ISO-NE Peak Hours (June-August) 2.8 101 20 Passive Dispatch during Summer ISO-NE Peak Hours (June-August) 1.6 57 47 Active or Passive Dispatch during Summer ISO-NE Peak Hours (June-August) 2.0 77 61 Total Dispatch during Summer Peak Period (non-holiday weekdays 1 p.m.-5 p.m. ET, June-August)1 0.3 39 65 Total Dispatch during Summer ISO-NE Peak Hours (June-August)1 1.4 55 92 Active Dispatch During Winter Peak Period (non-holiday weekdays 5 p.m.-7 p.m. ET, December-January) 1.4 292 2 Active Dispatch During Winter ISO-NE Peak Hours (December-January) 1.6 163 2 Total Dispatch During Winter Peak Period (non-holiday weekdays 5 p.m.-7 p.m. ET, DecemberJanuary)1 0.1 24 85 Total Dispatch During Winter ISO-NE Peak Hours (December-January)1 0.1 9 124 Evaluation Metric 1. “Total Dispatch...” metrics presented above are provided as averages calculated without filtering to only active or passive dispatch windows. Other rows for active, passive, or active or passive dispatch are averages over only the event window range. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-6 displays the percentage of active events aligned with the daily, seasonal, and annual peaks. No seasonal or annual peak events occurred prior to summer 2023 within the time period covered in the interval energy data. Notably, Eversource categorized the dispatch events called prior to summer 2023 as “test events” due to the limited number of systems available at that time. All events prior to summer 2023 occurred during the same 3-hour afternoon period (47pm), which was identified as most likely to include the daily peak. For the other two events presummer 2023 that missed the peak, the daily peak occurred in the late morning. Notably, for Information for the sole benefit and use of Connecticut Green Bank Page 42
  7. Page 47 of 106Match

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 47 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report each of these morning events, ISO-NE’s day-ahead forecast had projected peak demand to occur in the afternoon rather than in the morning. Due to the requirement that events be called 24 hours in advance, Eversource may not have known to call a morning event on those days. In addition, because the program manual stipulates that active dispatch events may only be called during 12-9pm, events likely could not have been called that would have aligned with the morning peak, regardless. As more devices enrolled into the ESS program, and dispatch events were no longer considered “test events,” peak coincidence improved from 50% in the year two annual evaluation to 67% for the collective summer 2023 and winter 2023/24 seasons. In aggregate, 63% of active events called by either EDC aligned with the ISO-NE daily peak. Table 4-6. Peak Targeting Percentages Percentage of Active Events Aligned w/ Daily Peak Percentage of Active Events Aligned w/ Seasonal Peak Percentage of Active Events Aligned w/ Annual Peak Eversource 68% 67% 100% UI 60% 67% 100% Utility Note: Aligned events refer to active events that are called during the time window of each peak (e.g., daily, seasonal, or annual) from the period of winter 2022-2023 through winter 2023-2024. Guidehouse excludes the ISO-NE annual peaks for 2022 and 2024 for the calculation of “Percentage of Active Events Aligned w/ Annual Peak,” as the first ESS event in 2022 was after the 2022 annual peak, and the annual peak for 2024 has likely not yet occurred. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. Table 4-7 displays battery performance metrics for the whole of the event season. These include battery availability (uptime) as a percentage of energy storage systems available at the start of events, solar energy used to recharge energy storage systems after dispatching vs. grid charging, and estimated bill savings. The number of systems analyzed is not uniform throughout the evaluation season due to factors such as systems enrolling into ESS and/or unenrolling. During events called between September 2022 and March 2024, nearly all batteries were available at the start of events, as demonstrated by the 99% Battery Availability (Uptime). Energy storage systems charged primarily from PV with a 71% share of average total device energy (kWh) charged from PV for “Solar Energy Used.” However, this share of PV charging is well below the nearly 100% PV charging expected from participating systems. The calculation for estimated bill savings is done in aggregate across the whole period with which telemetry data is available. Given that nearly all enrolled energy storage systems were charging with standard flat electricity rates (i.e., not Time-of-Use (TOU) rates that change throughout the day), there was no opportunity for bill savings from load shifting, and thus estimated bill savings are estimated to be negative due to energy storage performance loss. Given the relative infrequency of energy storage cycling and the relatively high round-trip efficiency of the energy storage systems, this increase in bills was minor for participants. Information for the sole benefit and use of Connecticut Green Bank Page 43
  8. Page 48 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 48 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Table 4-7. Battery Performance Metrics Performance Metric Value Battery Availability (Uptime)1 (%) 99% 2 Solar Energy Used (%) 71% Estimated Bill Savings3 ($) -$6,865.05 USD Estimated Bill Savings3 ($/participant) -$54.48 USD 1. Uptime is calculated as the percentage of energy storage systems with any available energy stored at the start of each active event, averaged over the course of the event season. 2. Solar Energy Used is calculated as the percentage of charging done from PV throughout the whole of the event season. 3. Estimated Bill Savings are calculated over the whole of the evaluation period, summed across all systems. In order to isolate bill savings from energy storage alone, calculations assume that, in the absence of a battery, paired PV would otherwise meet home load at the same price as customers are charged for normal energy consumption. Negative values indicate that the system costs more to charge than it earns through bill savings from discharging onsite. Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all events called since the program’s inception. Table 4-8 displays emissions evaluation metrics for Carbon Dioxide (CO2), Nitrogen Oxide (NOX), and Sulfur Oxide (SOX). Avoided emissions are calculated both using the EPA AVERT model and the AESC estimates of marginal emissions for CO2 and NOx. Given the limited number of energy storage systems enrolled at the time of evaluation, emission reductions are presented in pounds (lbs.) as opposed to tons. Table 4-8. Emissions Evaluation Metrics Avoided Emissions, per EPA AVERT Avoided Emissions, per 2021 AESC Avoided CO2 Emissions (lbs.) 45,089 42,378 Avoided NOX Emissions (lbs.) 0.90 3.17 Avoided SOX Emissions (lbs.) 0.30 N/A Emissions Metric Note: Given the reduced amount of energy storage, energy storage dispatch was scaled up by 100 in the case of CO2 & NOx, and SOx, to generate AVERT metrics, at which point, outputs were then scaled down by 100. 2021 AESC marginal emissions data does not include marginal SOx, so an estimate of avoided SOx emissions is not available with that method. Sources: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all active events called since the program’s inception. AVERT Model is available at: https://www.epa.gov/AVERT. 2021 AESC is available at: https://www.synapse-energy.com/project/aesc-2021-materials. Table 4-9 displays evaluation metrics by outage type, stratified by outages over or under 5 minutes in duration and with greater than or less than 10 participants in order to highlight the magnitude of each outage and its effects on program participants. From September 2022 through March 2024, 26 outage events occurred for more than 5 minutes for storage participants, with energy storage systems responding to 23 of them. Two outage events lasted for less than five minutes, and no storage systems dispatched during these quick outages. Information for the sole benefit and use of Connecticut Green Bank Page 44
  9. Page 49 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 49 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Table 4-9. Evaluation Metrics by Outage Type Number of Instances Energy Discharged During Outage (kWh/Outage) Instances Battery Provided Backup Power (#) Total kWh Dispatched Less than 10 participants 2 0 0 0 Less than 5 min Greater than 10 participants 0 0 0 0 More than 5 min Less than 10 participants 26 -2.4 23 -65 More than 5 min Greater than 10 0 0 0 0 Outage Duration Participants Affected per Outage Less than 5 min Source: Guidehouse analysis of interval energy data from September 15, 2022, through March 31, 2024, inclusive of all outage events identified since the program’s inception. 4.2 Findings and Recommendations Table 4-10. Evaluation Metrics Findings and Recommendations Finding Recommendation The share of energy storage system manufacturers in active events fluctuated throughout 2022-2024, with an overall average of 75% of devices participating in each active event. Additionally, these devices did not dispatch optimally, with a 3-year average dispatch around 50% of the energy expected during each event. Guidehouse recommends that the Program Administrators continue discussions with manufacturers about uniform dispatch capabilities and backup reserve settings to maximize active dispatch event performance. The timing of active events called during the analysis period was concurrent with the daily peak load for 65% of Eversource events and 61% of UI events. While this was an improvement from the year 2 peak concurrence of 50%, often when the timing did not align, the events were only off by an average of 1 hour from the daily ISO-NE peak. Importantly, rather than utilizing the full 3-hour active event window, EDCs often only called 2hour events resulting in missing the peak hour for that day. Guidehouse recommends that Eversource and UI consider expanding the active event window while considering the tradeoffs for longer dispatch periods (greater chance of hitting peak) vs. battery discharge available at time of peak, especially considering most missed peak concurrences were by one hour either before or after the event. Energy storage systems connected to DERMS charged from their co-located solar PV systems 71% of charging time, which represents a decrease from the year 2 evaluation that reported 99.4% charging from PV, though with a smaller sample size. Guidehouse recommends that the Program Administrators investigate what barriers, if any, are preventing participating systems from recharging with solar PV systems, including the timing of active and passive event windows and any battery settings that may cause a battery system to recharge at night from the grid after an event rather than from solar the next day. Average active event participation across the evaluation period was 74% for the summer season and 79% for the winter season. Event participation decreased as more devices enrolled in the program, and the summer 2023 season in particular experienced sporadic participation, some of which may be due to battery manufacturer settings preventing certain systems from responding to events due to weather conditions. Guidehouse recommends that the Program Administrators continue conversations with battery manufacturers around settings that may prevent battery systems from responding to active events when called. More frequent reviews of battery interval data (i.e., midseason or monthly) could also reveal issues with participation that may be addressed before the season is over. Information for the sole benefit and use of Connecticut Green Bank Page 45
  10. Page 50 of 106

    CL&P dba Eversource Energy Docket No. 26-08-01 November 15, 2026 Order No.2, Cross Posted Compliance 17-12-03RE03, ESS Order No. 25 Page 50 of 106 Connecticut Energy Storage Solutions – Final Evaluation Report Finding Recommendation No active events were called in June during either summer season, and the majority of active events for the summer 2023 season were called in July. The ISONE peaks for 2022 and 2023 also occurred in August and September, respectively. Guidehouse recommends that the Program Administrators consider extending and aligning the passive program season with the active season to better coincide with seasonal peaks (i.e., extending passive dispatch through September). Average passive event participation varied greatly in the summer 2023 season, ranging from 40% to 95% of systems participating per event with an average of 75% participation for the season. Average power dispatched during these events was similarly varied with a slightly higher average than active events at 53% of available maximum power dispatched. This figure is well below the program target of 80% of available power dispatched. No systems met the program’s 90% dispatch requirement in the first passive dispatch season. Guidehouse recommends that the Program Administrators further investigate barriers to passive event participation and confirm with battery manufacturers whether systems enrolled in the program can comply with the 90% passive dispatch requirement. Program Administrators should also consider modifying or suspending the claw back provision until the issues with passive event compliance are better understood. The Program Administrators could consider a grace period in which participants are not subject to claw back until their second or third summer in the program, which would allow time for adjusting battery settings to meet the passive dispatch requirements and ease the concerns of potential participants, as noted by the research in Section 6. Estimated bill savings were marginally negative (i.e., customers’ bills were higher than they would have been without energy storage) due to round-trip efficiency losses and lack of participation in TOU rates. Guidehouse recommends that Program Administrators consider requiring residential customer participation in TOU rates or provide education on potential benefits of TOU rates with battery storage. Both Eversource and UI called the same events for residential and C&I participants. While the utilities retain the ability to call events independently, the active events called by both utilities in the summer 2023 season largely aligned. N/A Source: Guidehouse analysis Information for the sole benefit and use of Connecticut Green Bank Page 46

Text of ES Order 2 - ESS Order 22 from 17-12-03RE03 Attachment 3.pdf

Extracted from the file · 8 pages · 20,187 characters

Text of ES Order 2 - ESS Order 22 from 17-12-03RE03 Attachment 2.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES Order 2 - ESS Order 22 from 17-12-03RE03 Attachment 1.pdf

Extracted from the file · 78 pages · 214,494 characters

Text of ES Order 1 - Table 1 DN 26-08-01 Compliance Filings.xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 8.pdf

Extracted from the file · 69 pages · 162,167 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 7.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 7.pdf

Extracted from the file · 1 page · 4,407 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 6.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 6.pdf

Extracted from the file · 21 pages · 73,536 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 5.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 5.pdf

Extracted from the file · 3 pages · 8,426 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 4.pdf

Extracted from the file · 4 pages · 1,020 characters

Text of ES Order 2 - EV Order 14 from 17-12-03RE04 Attachment 3.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - EV Order 16 from 17-12-03RE04.pdf

Extracted from the file · 1 page · 1,297 characters

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 4.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 4.pdf

Extracted from the file · 8 pages · 14,158 characters

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 3.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 3.pdf

Extracted from the file · 28 pages · 215,422 characters

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 2.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 2.pdf

Extracted from the file · 6 pages · 39,871 characters

Text of ES Order 2 - RRES Order 22 from 20-07-01 Attachment 1 (REDACTED).xlsx

Sheet names, column headings and text cells; numbers left out · first 300,000 characters

Text of ES Order 2 - NRES Order 20 from 20-07-01.pdf

Extracted from the file · 1 page · 1,427 characters

Text of ES Order 2 - NRES Order 19 from 20-07-01.pdf

Extracted from the file · 1 page · 1,354 characters

Text of ES Order 2 - NRES Order 18 from 20-07-01.pdf

Extracted from the file · 1 page · 1,557 characters

Text of ES Order 2, CEOP-VRO_Items 2 -4.pdf

Extracted from the file · 1 page · 485 characters

Text of ES Order 2, BETP-01.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2, BETP-01.pdf

Extracted from the file · 6 pages · 19,114 characters

Text of ES Order 2 - SCEF Order 9 from 19-07-01.pdf

Extracted from the file · 2 pages · 3,439 characters

Text of ES Order 2 - SCEF Order 6 from 19-07-01RE02 Attachment 1.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - SCEF Order 6 from 19-07-01RE02 Attachment 1.pdf

Extracted from the file · 2 pages · 73,616 characters

Text of ES Order 2 - SCEF Order 5 from 19-07-01RE02 Attachment 2.xlsx

Sheet names, column headings and text cells; numbers left out

Text of ES Order 2 - SCEF Order 5 from 19-07-01RE02 Attachment 2.pdf

Extracted from the file · 1 page · 5,854 characters

Text of ES Order 2 - SCEF Order 5 from 19-07-01RE02 Attachment 1.pdf

Extracted from the file · 4 pages · 6,318 characters

Text of ES Order 2, ESS_Items 1-4.pdf

Extracted from the file · 117 pages · 290,953 characters

Text of ES Order 2, VNM_Items 2-4.pdf

Extracted from the file · 3 pages · 1,101 characters

Text of ES Order 2, SCEF_Items 1-4.pdf

Extracted from the file · 49 pages · 109,450 characters

Text of ES Order 2, RRES_Items 1-4.pdf

Extracted from the file · 65 pages · 149,171 characters

Text of ES Order 2, RPS_Items 2-4.pdf

Extracted from the file · 1 page · 1,158 characters

Text of ES Order 2, NRES_Items 1-4.pdf

Extracted from the file · 51 pages · 132,948 characters

Text of ES Order 2, EV_Items 1-4.pdf

Extracted from the file · 118 pages · 178,717 characters

As listed on the current system

Compliance Filings, 11/16/2026 [26-08-01] Order No.Nos 1 and 2 Section IIA.1 / Eversource Energy / ES Annual Compliance Filing Orders 1 and 2

This filing on the current system (opens in a new tab)