  1. Page 29 of 63

    ALTOS® All-Dielectric Gel-Free Cables, 6-432 Fibers )LEHU&RXQW 1XPEHURI 7XEH3RVLWLRQV 1XPEHURI $FWLYH7XEHV :HLJKW 1RPLQDO2XWHU 0LQ%HQG 'LDPHWHU 5DGLXV,QVWDO ODWLRQ 0LQ%HQG 5DGLXV2SH UDWLRQ    NJNP OEIW PP LQ PP LQ PP LQ    NJNP OEIW PP LQ PP LQ PP LQ Chemical Characteristics )UHHRIKD]DUGRXVVXEVWDQFHVDFFRUGLQJWR5R+6(8 5R+6 7UDQVPLVVLRQ3HUIRUPDQFH Multimode )LEHU&RUH'LDPHWHU —P  )LEHU&DWHJRU\ )LEHU&RGH    20 20 20 20 . 7 7 7 3HUIRUPDQFH2SWLRQ&RGH     :DYHOHQJWKV QP     0D[LPXP$WWHQXDWLRQ G%NP     6HULDO*LJDELW(WKHUQHW P     6HULDO*LJDELW(WKHUQHW P     0LQ2YHUILOOHG/DXQFK 2)/  %DQGZLGWK 0+] NP     0LQLPXP(IIHFWLYH0RGDO %DQGZLGWK (0%  0+] NP     )DPLO\6SHF6KHHWB1$)7$B$(1 3DJH_5HYLVLRQGDWH
  2. Page 30 of 63

    ALTOS® All-Dielectric Gel-Free Cables, 6-432 Fibers Single-mode 60)HŠ// 60)Š8OWUD ILEHU )LEHU&DWHJRU\ *' )LEHU&RGH / 3HUIRUPDQFH2SWLRQ&RGH )LEHU1DPH 6LQJOHPRGH 26 6LQJOHPRGH 26 /($)ŠILEHU *'*$ *' *' * = ( ( )      :DYHOHQJWKV QP      0D[LPXP$WWHQXDWLRQ G%NP      7\SLFDO$WWHQXDWLRQ  G%NP      )LEHU1DPH 60)Š8// 7;)ŒILEHU )LEHU&DWHJRU\ * *( )LEHU&RGH 3 ' 3HUIRUPDQFH2SWLRQ&RGH   :DYHOHQJWKV QP   0D[LPXP$WWHQXDWLRQ G%NP   7\SLFDO$WWHQXDWLRQ  G%NP   For more information on typical attenuation please see the Corning whitepaper at http://csmedia.corning.com/opcomm//Resource_Documents/whitepapers_rl/ LAN-1863-AEN.pdf * SMF-28® Ultra fiber delivers up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better macrobend loss performance than the G.657.A1 standard for 10mm radii bends. )DPLO\6SHF6KHHWB1$)7$B$(1 3DJH_5HYLVLRQGDWH
  3. Page 31 of 63

    ALTOS® All-Dielectric Gel-Free Cables, 6-432 Fibers 2UGHULQJ,QIRUPDWLRQ_ Note: Contact Customer Care at [phone removed] for other options. 8       6HOHFW¿EHUFRXQW   60)Š8OWUD¿EHURQO\  6HOHFW¿EHUFRGH . —PPXOWLPRGH 20 7 —PPXOWLPRGH   202020 ( 6LQJOHPRGH *' / 6LQJOHPRGH *'    60)HŠ// = 6LQJOHPRGH *'   *$ 60)Š8OWUD¿EHU 3 6LQJOHPRGH *    60)Š8// ) 6LQJOHPRGH *    /($)Š ' 7;)Œ6LQJOHPRGH *(  '         'H¿QHVRXWHUMDFNHW  $OOGLHOHFWULF  6HOHFW¿EHUSODFHPHQW 7 ¿EHUVEXႇHUWXEH   VWDQGDUG  ¿EHUVEXႇHUWXEH 6HH1RWH  6HOHFWOHQJWKPDUNLQJV  0DUNLQJVLQPHWHUV  0DUNLQJVLQIHHW VWDQGDUG  'H¿QHVWHQVLOHVWUHQJWK  1OEI VWDQGDUG    6HOHFWSHUIRUPDQFH RSWLRQFRGH  —PPXOWLPRGH 20  —PPXOWLPRGH 20  —PPXOWLPRGH 20  —PPXOWLPRGH 20  6LQJOHPRGH 26   0D[DWWHQXDWLRQG%NP  6LQJOHPRGH 26   0D[DWWHQXDWLRQG%NP  6LQJOHPRGH 26   0D[DWWHQXDWLRQG%NP  6LQJOHPRGH 8OWUD/RZ/RVV   0D[DWWHQXDWLRQ±G%NP  6LQJOHPRGH 7;)   0D[DWWHQXDWLRQ±±G%NP  6LQJOHPRGH1='6)   0D[DWWHQXDWLRQ±±G%NP 1RQ=HUR'LVSHUVRQ6KLIWHG6LQJOHPRGH)LEHU  'H¿QHVFDEOHW\SH  'H¿QHVFDEOHW\SH 8 $/726Š/RRVH7XEH&DEOH   ZLWKPPEXႇHUWXEHV ' *HOIUHHFDEOH  'H¿QHVVSHFLDOUHTXLUHPHQWV  1RVSHFLDOUHTXLUHPHQWV 1) Cable outer diameter may change. Example: 48 F cable with 6 fibers per tube will require 8 active buffer and have an OD like a standard 96 F cable. Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA [phone removed] • FAX: [phone removed] • International: [phone removed] • www.corning.com/opcomm $FRPSOHWHOLVWLQJRIWKHWUDGHPDUNVRI&RUQLQJ2SWLFDO&RPPXQLFDWLRQVLVDYDLODEOHDWZZZFRUQLQJFRPRSFRPPWUDGHPDUNV $OORWKHUWUDGHPDUNVDUHWKHSURSHUWLHVRIWKHLUUHVSHFWLYHRZQHUV&RUQLQJ2SWLFDO&RPPXQLFDWLRQVLV,62FHUWLILHG ‹&RUQLQJ2SWLFDO&RPPXQLFDWLRQV$OOULJKWVUHVHUYHG )DPLO\6SHF6KHHWB1$)7$B$(1 3DJH_5HYLVLRQGDWH
  4. Page 32 of 63

    Product Description: AT-XXX17DT-144-CLGA - Maximum Span 455 ft  Loading Conditions NESC HEAVY PP LQ ,FH7KLFNQHVV 1PA NPKU  SVI 03+ :LQG3UHVVXUH & ) 7HPSHUDWXUH 1P OEIW 6DIHW\)DFWRU Tension @ Maximum Span for 1.5 % Installation Sag NJ OE 6KRUW7HUP NJ OE /RQJ7HUP Specifications: P IW 0D[LPXP6SDQ NJP OEIW &DEOH:HLJKW PP LQ &DEOH'LDPHWHU & ) ,QVWDOODWLRQ7HPS &DEOH0RGXOXV NJPPA NSVL /LQHDU([SDQVLRQ&RHIILFLHQW & ) (VWLPDWHG%UHDN/RDG NJ OE Maximum Cable Length: Dependent on construction and/or fiber type 6LQJOHPRGH  P  IW 0XOWLPRGH  P  IW No Loading @ Install Temperature 68 F All Loading Conditions @ Temperature 0 F 6SDQ 6DJ 7HQVLRQ 7HQVLRQ 9HUWLFDO6DJ +RUL]RQWDO6DJ ,QVWDOO6DJ 9HUWLFDO6DJ IW IW  OE RI6SDQ OE IW IW                                                                                                                                                         The recommended maximum space potential at ADSS attachment point is 12 kV Dead End Assembly: 026'25)(5'HDG(QG$6)'(60D[7HQVLRQOEV NJ 3/3'HDG(QG&(0D[7HQVLRQOEV NJ Slack Storage Devices: Not recommended for TR cables 3/3)LEHUOLJQŠ&/$66WRUDJH6\VWHPZFDEOHJXLGH8 Heliformed Suspension Units (Line angle changes<= 30 degrees): 3/3<&6SDQVIWWRIW PWRP 3/36$OXPLQXP6XVSHQVLRQZLWK655URGV0D[6SDQIW P Fixed Tangent Support (Line Angle Changes <= 20 deg & Spans <= 600 ft (183 m) 026'25)(56XSSRUW&ODPS)26& 3/3'LHOHFWULFEORFN 3/3$OXPLQXP6XSSRUW Vibration Dampers, see Application Note 812 for recommendations: 0256'25)(59LEUDWLRQ'DPSHUV69' 3/39LEUDWLRQ'DPSHUV Suspended Support (Line Angle Changes <= 20 deg & Spans <= 600 ft (183 m) 3/3$OXPLQXP6XVSHQVLRQ6 Down Lead Cushion & Abrasion Protector: 3/3$GG+:RRG$WWDFKPHQW.LW /7&/DWWLFH&ODPS.LW 3/3$EUDVLRQ3URWHFWRU37*/HQJWKIW Low Tension / Short Span Hardware: 026'25)(5/LJKW7HQVLRQ'()2/7&720D[7HQVLRQOEV NJ 3/3/LWH7HQVLRQ'(&10D[7HQVLRQOEV NJ 3/3/LWH6XSSRUW0D[6SDQIW P 3/33*77+'HDG(QG1RW$YDLODEOH Corona coils not required 3/36L]HGWRILWDSSURSULDWHKDUGZDUHSDUWQXPEHUVDYDLODEOHXSRQUHTXHVW ([FOXVLYH8VHRI2)6DQG&XVWRPHU'HILQHG$ERYH  $QJOH 'HJ                   
  5. Page 33 of 63

    Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ) AFL LE-Series Gel-Free Single Jacket fiber optic cables incorporate dry water-absorption technology within the fiber-containing buffer tubes. This results in user-friendly handling of fibers during routing and termination within the splice enclosures. Features Applications • Fiber counts up to 144 • Gel-free buffer tubes reduce fiber prep termination time • Reverse-oscillated (SZ stranded) to allow slack for mid-span access • UV-stabilized outer jacket for long-term performance in aerial applications • Distribution • Underground Duct • Long Haul Networking • Building Interconnections (Campus LAN) • Trunking Lines Direct to Telecommunications Closet • Local Loop Cable Components Typical Lengths FIBER COUNT 6 - 60 72 - 96 108 -120 132 - 144 MAXIMUM LENGTHS* SINGLE-MODE MULTIMODE FEET METERS FEET METERS 22,900 7,000 22,900 7,000 22,900 7,000 22,900 7,000 22,900 7,000 22,900 7,000 22,900 7,000 22,900 7,000 Polyethylene jacket Polyester tape Optical fiber FRP central member Rip cord Water-blocking system Gel-free loose buffer tube * Longer lengths may be available upon request. Fiber Specifications FIBER TYPE (6) 62.5/125 GIGA-Link™ 300 (5) 50/125 GIGA-Link™ 600 (L) 50/125 Laser-Link™ 300 (9) Single-mode (Q) Non-zero Dispersion-shifted Single-mode (K) AFL G.657.A1 Single-mode MAXIMUM ATTENUATION (DB/KM) 850 NM 1300 NM 1310 NM 1550 NM 3.5 1.2 N/A N/A 2.9 0.9 N/A N/A 2.9 N/A N/A 0.9 N/A N/A 0.35 0.25 N/A N/A N/A 0.25 N/A N/A 0.35 0.25 OVERFILL LAUNCH MIN. BANDWIDTH (MHZ•KM) 850 NM 1300 NM 200 600 500 500 GIGABIT ETHERNET MIN. LINK DISTANCE (METERS) 850 NM 1300 NM 300 550 600 600 1500 500 900 550 N/A N/A N/A N/A N/A N/A N/A N/A N/A 5000 N/A 5000 Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints. Actual link distances may be constrained by attenuation, depending on specific loss budget. continued AFLglobal.com | [phone removed] 1 © 2014, AFL, all rights reserved. PP-1-00101, Revision 3, 4.16.2020 Specifications are subject to change without notice. Fiber Optic Cable FIBER OPTIC CABLE
  6. Page 34 of 63

    FIBER OPTIC CABLE Fiber Optic Cable Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ) Mechanical Data AFL NO. LE012‘C5101N1D LE024‘C5101N1D LE036‘C5101N1D LE048‘C5101N1D LE060‘C5101N1D LE072‘C6101N1D LE096‘C8101N1D LE144‘CC101N1D NO. OF TUBES NOMINAL DIAMETER FIBER COUNT FIBERS/ TUBE 12 1/12 (4 fillers) 24 2/12 (3 fillers) 36 3/12 (2 fillers) 48 4/12 (1 filler) 60 5/12 (no fillers) 72 6/12 (no fillers) 96 8/12 (no fillers) 144 12/12 (no fillers) INCHES (MM) 0.39 (9.8) 0.39 (9.8) 0.39 (9.8) 0.39 (9.8) 0.39 (9.8) 0.42 (10.6) 0.48 (12.3) 0.62 (15.8) NOMINAL WEIGHT LBS/1,000FT (KG/KM) 49 (73) 49 (72) 48 (72) 48 (71) 48 (71) 55 (82) 75 (118) 119 (178) MAXIMUM TENSILE LOAD LBS (N) MINIMUM BEND RADIUS INCHES (CM) SHORT TERM LONG TERM SHORT TERM LONG TERM 600 (2670) 180 (800) 7.8 (20) 5.9 (15) 600 (2670) 180 (800) 7.8 (20) 5.9 (15) 600 (2670) 180 (800) 7.8 (20) 5.9 (15) 600 (2670) 180 (800) 7.8 (20) 5.9 (15) 600 (2670) 180 (800) 7.8 (20) 5.9 (15) 600 (2670) 180 (800) 8.4 (21) 6.3 (17) 600 (2670) 180 (800) 9.6 (25) 7.2 (19) 600 (2670) 180 (800) 12.4 (32) 9.3 (24) Note: Diameter and weight subject to change without notice ‘ Fiber Types – Replace asterisk (‘) in AFL number with number in the Fiber Specifications table on previous page. Reel Information ITEM Reel Height Reel Width Outside Reel Width Inside Drum Diameter Arbor Hole Diameter Reel Weight With Lagging REEL A INCHES CM 42 106.7 36 91.4 32 81.6 23 58.7 3 7.9 REEL B INCHES CM 58 147.3 38 96.5 32 81.3 28 71.1 3 7.9 REEL C INCHES CM 66 167.6 42 106.7 36 91.4 36 91.4 3 7.9 REEL D INCHES CM 72 182.8 42 106.7 36 91.4 36 91.4 3 7.9 REEL E INCHES CM 84 213.4 40 101.6 34 86.4 35 88.9 3 7.9 180 lbs 420 lbs 685 lbs 710 lbs 950 lbs 82 kg 191 kg 311 kg 320 kg 431 kg AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request. Larger reel sizes may be required to accomodate long cable lengths. Temperature Specifications Qualifications GOVERNING BODY STANDARD CODE COMPONENT Telcordia GR-20-CORE Cable ICEA TIA 640 598-D Cable Fiber TEMPERATURE RANGE Operation -40°C to +70°C Storage -40°C to +75°C Installation -30°C to +70°C Contact AFL for your customized cable solution. AFLglobal.com | [phone removed] 2 © 2014, AFL, all rights reserved. PP-1-00101, Revision 3, 4.16.2020 Specifications are subject to change without notice.
  7. Page 35 of 63

    7RWDOO\'U\'XDO3XUSRVH&DE 'XUDELOLW\IRU2XWVLGH3ODQWWR 3URGXFW'HVFULSWLRQ T he OFS PlenumXcel™ Indoor/Outdo Plenum Cable is a completely dry c that innovatively combines the Àame resistan and safety features of a plenum-rated cable with the durability critical to outside plant use. The result is a unique, dual-purpose cable that saves time and money by allowing outside plant applications to Àow seamles indoors, using a single plenum-rated cable a splices. The construction of this cable begins by placing 12 optical ¿bers within each dry, color-coded buffer tube. The buffer tubes are then stranded around a dielectric central member using the reverse oscillating lay (ROL) technique. In the ¿nal step, DryBlock™ water-blocking material, dielectric strength elements, and a UV and Àame-resistant jacket encase the core to complete the cable construction. :K\WKH3OHQXPXcel&DEOH" T he PlenumXcel Indoor/Outdoor Cable is speci¿cally designed for customers requiring a plenum-rated cable who also want to save on installation time and money by eliminating the use of multiple cables and splicing. With its totally dry design, this cable further streamlines cable handling and routing by eliminating messy gels and ¿lling compounds, while delivering excellent water penetration resistance. The PlenumXcel Cable also enhances system performance by avoiding the attenuation loss created by multiple splice points. By compartmentalizing the optical ¿bers within buffer tubes, PlenumXcel Cable makes it easy to locate speci¿c ¿bers for drop-off applications without disturbing other active ¿bers and tubes. ROL stranding of the buffer tubes enables easy mid-span access and cable entry. PlenumXcel Indoor/Outdoor Cable Cross-Section Features and Benefits: ‡6WUHDPOLQHGLQVWDOODWLRQZLWKGLUHFWRXWGRRUWRLQGRRUFDEOHWUDQVL WLRQV ‡7RWDOO\GU\FDEOHGHVLJQIRUIDVWHUDQGHDVLHUFDEOHKDQGOLQJDQG URXWLQJ ‡(QKDQFHVV\VWHPSHUIRUPDQFHE\DYRLGLQJDGGLWLRQDOVSOLFHSRLQW DWWHQXDWLRQORVV ‡6XLWDEOHIRULQVWDOODWLRQVLQFOXGLQJRXWVLGHSODQWWREXLOGLQJ WUDQVLWLRQVFDPSXVHQYLURQPHQWV/RFDO$UHD1HWZRUNV /$1V  SULYDWHQHWZRUNVDQGLQWHUEXLOGLQJLQVWDOODWLRQV ‡)LEHUFRXQWVIURPWRILEHUV ‡$OOGLHOHFWULFSOHQXPUDWHGFRQVWUXFWLRQZLWK2)13DSSURYDO >2)13&6$)7SHU1(& D DQG D @ ‡0HHWV8/ SOHQXPUDWHG DQG&6$)7IRUIODPHUHVLVWDQFH ‡)HDWXUHV2)6DSSOLFDWLRQVSHFLILFILEHUVLQFOXGLQJ$OO:DYHŠDQG 7UXH:DYHŠILEHUV
  8. Page 36 of 63

    Fiber Count: Cable Outside Diameter (mm): Cable Weight kg/km (lb/kft): Bend Radius: Compressive Load – N/cm (lbf/in): Maximum Rated Tension: Temperature (all ¿ber counts): Fiber counts from 2 to 144 .313 in.(7.9 mm) to .482 in. (12.2 mm) 68.5 kg/km (46 lb/kft) to 146 kg/km (98.1mm) 10 x cable diameter under static load (installed) 20 x cable diameter under dynamic load (during installation) 263N/cm (150 lb/in.) 1350N (300 lb) Installation: 0°C to 60°C (-22°F to 140°F) Operation: -20°C to 70°C (-4°F to 158°F) Storage: -20°C to 75°C (-4°F to 167°F) Cable Test Tensile Performance Crush Performance Bending Performance Temperature Cycle Position S1 S2 Description Fiber Transmission Performance Fiber Attenuation Speci¿cation 3 6 R Options AllWave Single-mode 1310/1550nm TrueWave RS Single-mode 1550nm Multimode 850/1300nm 4 B 2 Single-Mode Options 0.40/0.30 dB/km (AllWave) 0.35/0.25 dB/km (AllWave) 0.25 dB/km (TrueWave) Multimode Options U 3.4/1.0 dB/km & 200/500 MHz-km G 2.4/0.7 dB/km and 500/900 MHz-km E AllWave Single-mode 6 TrueWave RS Single-mode SF Fiber Type 9 62.5/125 ȝm Multimode 2 50/125 ȝm Multimode S3 Central Member 1 Dielectric Central Member S4 Tensile Load 3 300 lb. (1350N) S5 Core Type P Indoor/Outdoor Plenum Loose Tube S6 Fibers Per Tube T 12 ¿bers Example: AT-3BE13PT-024 = 24 Fiber Indoor/Outdoor Plenum Dielectric Central Member AllWave Fiber Test Method EIA/TIA-455-33 IEC 794-1-E1 EIA/TIA-455-41 ICEA S-104-696 IEC 794-1-E3 Requirement: Parameter Single-Mode: 0.4 dB max EIA/TIA-455-37 Parameter Multimode: 0.6 dB max IEC 794-1-E11 EIA/TIA-455-3 IEC 794-1-E1 or additional information please contact your sales representative. ou can also visit our website at http://www.ofsoptics.com or call -888-¿berhelp. For regional assistance, contact: Asia Paci¿c Telephone: +852 2506 5054 Fax: +852 2506 0166 E-mail: ¿[email removed] Caribbean, Latin America Telephone: [phone removed] ax: [phone removed] E-mail: ¿[email removed] Japan Telephone: +81-3-3286-3424 Fax: +81-3-3286-3708 or 3190 E-mail: ¿[email removed] China Telephone: +86 10 6505 3660 Fax: +86 10 65059515 E-mail: ¿[email removed] ryBlock and PlenumXcel are trademarks of Furukawa Electric North America, Inc. AllWave and TrueWave are registered trademarks of Furukawa lectric North America, Inc. FS reserves the right to make changes to the prices and product(s) described in this document in the interest of improving internal design, operational function, and/or reliability. OFS does not assume any liability that may occur due to the use or application of the product(s) and/or circuit layout(s) described herein. This document is for informational purposes only and is not intended to modify or supplement any OFS warranties or speci¿cations relating to any of its products or services. Copyright © 2005 Furukawa Electric North America, Inc. All rights reserved, printed in USA. OFS Marketing Communications osp-140-0105
  9. Page 37 of 63

    IN MA FACTURE D NU ezSPAN® ADSS All-dielectric self-supporting loose tube cable Aramid Strength Yarns Inner Jacket Polyethylene (optional) Central Strength Member Water Blocking Material Gel-Filled Buffer Tube Containing up to 12 Fibers Ripcord All-Dielectric Self-Support (ADSS) easy entry fiber cable for up to 1200' (365m) spans typical in distribution. Overview Features and Benefits Prysmian’s ezSPAN® ADSS provides reliable self-support performance for up to 1200 feet (365 meters). Each ezSPAN® ADSS cable is custom engineered for each application based on its full weather load, ensuring safe, reliable lifetime performance. Flexible buffer tubes enable ease of mid-entry, preparation and routing in splice closures. These cables uniquely combine flexible buffer tubes and swellable water-blocking to make ezSPAN the easiest ADSS cables to prep and access. Easy Cable Entry and Preparation - 12 fibers per tube construction up to 144 fiber designs allow easy termination and mid-span fiber access - Flexible buffer tubes and single jacket option enhance mid-entry - Ripcord speeds cable entry and outer jacket removal - Swellable binders speed cable preparation Flexible Routing and Termination Product Snapshot - Flexible buffer tubes simplify routing, storage and prep Applications Self-supporting aerial deployment for communications & power transmission - Available with G657.A1 and G657.A2 bend-insensitive single-mode fiber Constructions All-dielectric round - typical span lengths up to 1,200' (305m), single and dual jacket 12 to 144 fibers in color coded buffer tubes Fiber Types Single-mode / bend-insensitive / NZDSF / multimode / hybrid Standards IEEE 1222-2011, ANSI / ICEA 640, IEC, RUS 7 CFR 1755 (RUS LISTED), Telecordia GR-20 Registered Supplier ISO 9001, ISO 14001, TL 9000, and OHSAS 18001 Other Versions Long Span ADSS - Tailored designs span distances up to 1200’ (305m) without interrupting power - Easy mid-entry is ideal for FTTx distribution applications - Matching pole attachment hardware (dead-ends, suspension clamps) Reliable Lifetime Performance - RUS LISTED Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom Custom engineered for operation under full load Guaranteed standards-based performance 500A DS062 EZSPAN ADSS 05-18 Fiber Count Versatile Installation and Use
  10. Page 38 of 63

    ezSPAN® ADSS All-Dielectric Self-Supporting Loose Tube Cable PLP ATTACHMENT HARDWARE CONSIDERATIONS - Dead-ends indicated are Limited & Medium Tension dead-ends. The Limited Tension dead-end is designed for a maximum long-term tension of 1000 lbs and short-term tension of 2500 lbs. The Medium Tension dead-end is designed for 2000 lbs for long-term tensions and 4000 lbs for short-term loads. Semi-high or High Tension dead-ends should be used for higher tension ratings. - Limited Tension dead ends are limited to a maximum span length of 600 feet. - C1E1 designates thimble clevis and extension link (recommended). - Aluminum Suspension is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet. - Spans of > 600 to 1200 feet require reinforcing rods (SSR). - The “S” designates anchor shackle and eye-nut (recommended). - Vibration dampers may be required. - Aluminum support is designed for in-line support with a maximum angle change of 20° and a maximum span of 600 feet. INSTALLATION SPECIFICATIONS Minimum Bend Radius With load: 20x cable diameter No load: 10x cable diameter Temperature Range Shipping and Storage Installation Operation -40o F to +167o F -22o F to +140o F -40o F to +158o F (-40o C to +75o C) (-30o C to +60o C) (-40o C to +70o C) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS062 EZSPAN ADSS 05-18 Maximum Stringing Tension: 600 lbs