Page 44 of 63
ezSPAN® ADSS All-Dielectric Self-Supporting Loose Tube Cable NESC Heavy Loading ezSPAN Double Jacket 12-72 Fibers PLP Attachment Hardware Part # Span Distance (ft) Cable Outside Diameter (in) Maximum Rated Cable Load (MRCL) (lbs) up to 300 0.533 1031 1.5 F-ADED1031-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101 350 0.536 1161 1.5 F-ADED1161-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101 4450101 Initial Sag (%) *Cable Part Numbers Dead End Al Suspension w/o SSR (< 600 ft) Al Suspension with SSR Al Support Spans < 600 ft 400 0.539 1341 1.5 F-ADED1341-12-HB-XXX 2872005C1E1 4450201S 4470201S 450 0.542 1481 1.5 F-ADED1481-12-HB-XXX 2872005C1E1 4450201S 4470201S 4450101 500 0.545 1661 1.5 F-ADED1661-12-HB-XXX 2872006C1E1 4450201S 4470201S 4450101 550 0.548 1841 1.5 F-ADED1841-12-HB-XXX 2872006C1E1 4450201S 4470201S 4450101 600 0.552 2021 1.5 F-ADED2021-12-HB-XXX 2872006C1E1 4450201S 4470202S 4450101 650 0.555 2201 1.5 F-ADED2201-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101 700 0.558 2381 1.5 F-ADED2381-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101 750 0.560 2511 1.5 F-ADED2511-12-HB-XXX 2872102C1E1 4450201S 4470202S 4450101 Span Distance (ft) Cable Outside Diameter (in) Maximum Rated Cable Load (MRCL) (lbs) Initial Sag (%) *Cable Part Numbers up to 290 0.618 1031 1.5 F-ADED1031-12-HB-XXX 300 0.619 1071 1.5 F-ADED1071-12-HB-XXX 84-96 Fibers PLP Attachment Hardware Part # Dead End Al Suspension w/o SSR (< 600 ft) Al Suspension with SSR Al Support Spans < 600 ft 2872008C1E1 4450202S 4470202S 4450102 2872008C1E1 4450202S 4470202S 4450102 350 0.622 1251 1.5 F-ADED1251-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102 400 0.625 1431 1.5 F-ADED1431-12-HB-XXX 2872008C1E1 4450202S 4470202S 4450102 450 0.627 1611 1.5 F-ADED1611-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103 500 0.631 1841 1.5 F-ADED1841-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103 550 0.634 2021 1.5 F-ADED2021-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103 600 0.636 2201 1.5 F-ADED2201-12-HB-XXX 2872008C1E1 4450203S 4470203S 4450103 650 0.639 2381 1.5 F-ADED2381-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103 700 0.642 2561 1.5 F-ADED2561-12-HB-XXX 2872104C1E1 4450203S 4470203S 4450103 108-144 Fibers Span Distance (ft) Cable Outside Diameter (in) Maximum Rated Cable Load (MRCL) (lbs) Initial Sag (%) *Cable Part Numbers Dead End Al Suspension w/o SSR (< 600 ft) Al Suspension with SSR Al Support Spans < 600 ft up to 240 0.785 1031 1.5 F-ADED1031-12-HB-XXX 2872012C1E1 250 0.786 1071 1.5 4450205S 4470205S 4450105 F-ADED1071-12-HB-XXX 2872012C1E1 4450205S 4470205S 300 0.788 1301 4450105 1.5 F-ADED1301-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 350 0.791 1521 1.5 F-ADED1521-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 400 450 0.794 1751 1.5 F-ADED1751-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 0.796 1931 1.5 F-ADED1931-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 500 0.798 2157 1.5 F-ADED2157-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 550 0.801 2381 1.5 F-ADED2381-12-HB-XXX 2872012C1E1 4450205S 4470205S 4450105 600 0.804 2621 1.5 F-ADED2621-12-HB-XXX 2872108C1E1 4450205S 4470205S 4450105 Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS062 EZSPAN ADSS 05-18 PLP Attachment Hardware Part #Page 45 of 63
ezSPAN® ADSS All-Dielectric Self-Supporting Loose Tube Cable ORDERING CHECK LIST 1 Installation Location: City _____________________________ State ___________ 2 Cable Length Marking Feet Meters 3 # of Jackets: Single Jacket Dual Jacket 4 Number of Fibers: _______________ 5 Fiber Type & Grade: _______________ 6 Max. Span Length: (ft or m) _______________ 7 Installation Sag: 1.5% Other (Please Specify) _____________ 8 NESC Loading Condition: Light Medium Heavy Other (Define Ice & Wind Load) __________________ 9 Line Voltage: None Distribution Line Transmission Line ______ Phase to Phase (kV) ______ Phase to Ground _______ Fiber Strain: Safe Strain Zero Strain Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS062 EZSPAN ADSS 05-18 10Page 46 of 63
Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below Example: ezSpan™ ADSS | single jacket (12 fibers/tube) with 144 single-mode fibers (printed in feet) LENGTH MARKINGS 1 2 PRODUCT FAMILY F ADE 3 CONSTRUCTION S PART NUMBER CONSTRUCTION 1 LENGTH MARKINGS 4 LOAD RATING 5 FIBER GROUPING XXXX 6 12 FIBER TYPE 7 8 FIBER COUNT HB 144 FIBER GRADE E3 FIBER INFORMATION 6 FIBER TYPE SINGLE-MODE F = Feet or M = Meters HB = Single-Mode (ITU G.652 C & D) Low Water Peak 2 PRODUCT FAMILY ES = Enhanced Single-Mode (ITU G.652 C & D) ADE = ezSpan ADSS CE = Corning™ SMF28e+ Single-Mode ADS = Short Span ADSS B1 = Bend-Insenitive Single-Mode (ITU G.657.A1 & G.652.D) B2 = Bend-Insenitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) 3 4 5 CONSTRUCTION TU = TeraLight™ Ultra Single-Mode (ITU G.655 & G.656) S = Single Jacket LE = LEAF NZDSF (ITU G.655) D = Double Jacket MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) 10 GbE Dist (m) LOAD RATING G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ Max Rated Cable Load (lbs) G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ FIBER GROUPING G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ 12 = 12f per tube 7 FIBER COUNT 004 to 144 fibers 8 FIBER GRADE SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, or B2 NA = 0.40/0.25 N1 = 0.25 MULTIMODE Attenuation (dB/km) 1310/1550 1550 TeraLight™ Ultra Single-Mode LEAF Single-Mode Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2018 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued May 2018. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS062 EZSPAN ADSS 05-18 Other cable constructions and fiber performance grades available on request.Page 47 of 63
Prysmian Group Introduces New Ultra-Compact, Flexible Ribbon Technology at 2018 ISE Expo New FlexRibbon™ products can reach 3456 optical fiber to offer increased functionality to data centers nationwide Highland Heights, Kentucky – July 31, 2018 – Prysmian Group North America, a world leader in the energy and telecom cable systems industries, recently announced the rollout of two enhancements to its line of FlexRibbon™ products. This new line of products, which feature MassLink™ with FlexRibbon™ Technology and will support large-scale data centers operated by major companies across the U.S., will be debuted in North America at the upcoming 2018 ISE Expo in Denver, CO. “We are thrilled to rollout these new enhancements to our FlexRibbon™ line in anticipation of Prysmian expanding into new markets,” said Massimo Battaini, CEO for Prysmian Group North America. “As the demand for more powerful, higher-density cables continues to increase, this latest offering will be a key asset for large companies to navigate underground duct networks.” Designed to maximize fiber density and duct space utilization, Prysmian’s MassLink™ with FlexRibbon™ Technology products compact the maximum fiber count into the smallest cable possible by using extremely flexible fiber ribbons that can either be rolled up for high packing densities or laid flat for ribbon splicing. The new 1728 and 3456 fiber count FlexRibbon™ products feature an ultra-compact outside plant cable design that contains bend insensitive fibers, small enough to fit into a 1.25” and 1.50” duct, respectively. “We began development of our FlexRibbon™ Technology product line to meet the needs of customers here in North America with hyperscale and colocation data centers that require ultra-compact design and efficient installation,” said Stephen Szymanski, Vice President of Telecom for Prysmian Group North America. “We have continued to heavily invest in the R&D of FlexRibbon™ technology, employing the most advanced equipment, which has led to the development of these new FlexRibbon™ product offerings.” The significantly smaller diameter and lighter weight cables have superior kink resistance and increased flexibility, which allows for easier installation and the use of smaller ducts. In the case of the 1728 fiber design, there is a 21 percent smaller diameter (38 percent volume reduction) over traditional flat ribbon designs. And while the new FlexRibbon™ products provide high packing density, they also feature 200 and 250-micron fiber ribbons that still provide the advantages of mass fusion splicing. -more- Release No. 1067Page 48 of 63
With this latest product enhancement, Prysmian Group is reaffirming its commitment to investing in its optical fiber and cable capacities to respond to the evolving needs of the market and support its customers in developing new, reliable and efficient broadband networks. Join us for the introduction of these new products at the upcoming 2018 ISE Expo. Held from August 14-16 in Denver, CO, the ISE Expo is the ICT industry’s premier educational event for wireline and wireless network evolution. Come visit us at our booth (#827) and for more information about Prysmian Group, visit na.prysmiangroup.com. About Prysmian Group North America Prysmian Group serves both the telecom and energy cable markets in North America with over 5,800 employees at 23 plants across the continent and sales of over $1.5 billion in 2016. Headquartered in Highland Heights, Kentucky, Prysmian’s North American Telecom Solutions unit produces a range of high-quality copper and fiber optic cable and solutions for data, video and voice transmission applications. In the energy sector, the company offers end-to-end underground cables solutions for the transmission and distribution of low, medium, high and extra high voltage systems. Prysmian Group has two fiber optic manufacturing facilities in the United States, including the only co-located fiber and cable facility in North America. Prysmian Group is a public company, listed on the Italian Stock Exchange in the FTSE MIB index. Media Contacts Charlie Schicht External Communications Manager T: [phone removed] [email removed] Hannah Nuccio Lou Hammond Group T: [phone removed] [email removed] ### Release No. 1067Page 49 of 63
IN MA FACTURE D NU CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables Flame Retardant Jacket Flame Retardant Tape Central Strength Member Water Blocking Tape Dry Buffer Tube Containing up to 12 Fibers Ripcord Versatile indoor-outdoor flame rated fiber cables - ideal for interbuilding and building transition applications Overview Prysmian’s indoor-outdoor dry loose tube riser or plenum designs provide flame-rated network solutions for a diverse number of network applications. These cables combine flexible dry buffer tubes and swellable water blocking materials with Prysmian’s extensive portfolio of single-mode and multimode optical fibers. Incorporating proven outside plant design elements, this cable may be employed in outdoor aerial lashed, duct, and direct buried environments. Because of its application diversity, this advanced product eliminates the necessity and expense for traditional cable transition points once required in legacy systems. Cost savings and system long term reliability are achieved by enabling cable placement virtually anywhere in the network. Product Snapshot Applications Multi-purpose indoor/outdoor aerial, lashed, duct, and direct buried Constructions Dielectric (single & dual jacket), ezPREP® corrugated armor, interlock armor Features and Benefits - Fiber identification using TIA standardized color coding - Dry buffer tubes simplifies access and reduces prep time - Flame-retardant, black UV-resistant outer jacket - Available with bend-insensitive single-mode and multimode optical fibers - Interlock armor designs available for added durability - Will support all high performance networks including OM4/10 gigabit ethernet systems Flexible kink-resistant buffer tubes for routing and storage Fiber Count 2 to 288 (Riser) / 2-144 (Plenum) Fiber Types Single-mode (ESMF, bend-insensitive) multimode (62.5/125-OM1, 50/125-OM2+, OM3 & OM4) Standards TIA/EIA-568, ANSI/ICEA S-83-596, ANSI/ ICEA S-104-696, UL-1666, NFPA 262, CSA 22.2 No 230, Telcordia GR-409, Telcordia GR-20, CE RoHS Compliant Registered Supplier ISO 9001, ISO 14001, TL 9000, and OHSAS 18001 Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Flame Ratings Riser (OFNR / OFCR / FT4) / Plenum (OFNP/OFCP/FT6)Page 50 of 63
CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser Dielectric (Single Jacket - Dry) DRLDB Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) 2 to 60 5 12 0.40 (10.1) 63 (93) 8.0 (20.2) 4.0 (10.1) 62 to 72 6 12 0.43 (10.8) 69 (102) 8.6 (21.7) 4.3 (10.9) 74 to 84 7 12 0.47 (12.0) 85 (126) 9.5 (24.0) 4.8 (12.0) 86 to 96 8 12 0.50 (12.8) 96 (143) 10.1 (25.6) 5.1 (12.8) 5.5 (13.9) 98 to 108 9 12 0.55 (13.9) 114 (169) 11.0 (27.8) 110 to 120 10 12 0.57 (14.5) 123 (183) 11.4 (29.0) 5.7 (14.5) 122 to 132 11 12 0.60 (15.4) 139 (207) 12.1 (30.8) 6.1 (15.4) 6.5 (16.4) 134 to 144 12 12 0.64 (16.3) 158 (234) 12.9 (32.7) 146 to 216 12 / 6 12 0.67 (17.0) 153 (228) 13.5 (34.1) 6.8 (17.1) 218 to 264 14 / 8 12 0.73 (18.6) 184 (273) 14.7 (37.3) 7.4 (18.7) 266 to 288 15 / 9 12 0.78 (19.7) 205 (305) 15.6 (39.5) 7.8 (19.8) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) Note: the compression rating for counts of 60 and below is 100N/cm. CampusLink LT™ I/O Riser Dielectric (Double Jacket - Dry) DRLDC Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.52 (13.2) 114 (169) 10.4 (26.4) 5.2 (13.2) 62 to 72 6 12 0.55 (13.9) 123 (183) 11.0 (27.9) 5.5 (14.0) 74 to 84 7 12 0.59 (15.1) 144 (214) 11.9 (30.2) 6.0 (15.1) 86 to 96 8 12 0.63 (15.9) 159 (237) 12.6 (31.8) 6.3 (15.9) 98 to 108 9 12 0.67 (17.0) 181 (270) 13.4 (34.0) 6.7 (17.0) 110 to 120 10 12 0.69 (17.6) 194 (288) 13.9 (35.2) 7.0 (17.6) 122 to 132 11 12 0.73 (18.5) 214 (318) 14.6 (37.0) 7.3 (18.5) 134 to 144 12 12 0.76 (19.4) 237 (352) 15.3 (38.9) 7.7 (19.5) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.Page 51 of 63
CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser with Corrugated Armor (1A 2J - Dry) DRLDD Series | OFCR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 62 to 72 6 12 Cable Weight lb/kft (kg/km) Bend Radius Load inches (cm) 0.63 (16.0) 190 (283) 12.6 (32.0) 6.3 (16.0) 0.66 (16.8) 204 (304) 13.2 (33.6) 6.6 (16.8) Diameter inches (mm) Bend Radius No Load inches (cm) 74 to 84 7 12 0.71 (18.0) 231 (344) 14.2 (36.1) 7.1 (18.1) 86 to 96 8 12 0.74 (18.8) 250 (372) 14.8 (37.6) 7.4 (18.8) 98 to 108 9 12 0.78 (19.8) 278 (413) 15.6 (40.0) 7.8 (19.9) 110 to 120 10 12 0.80 (20.3) 294 (438) 16.0 (40.7) 8.0 (20.4) 122 to 132 11 12 0.84 (21.3) 320 (476) 16.8 (42.7) 8.4 (21.4) 134 to 144 12 12 0.88 (22.4) 347 (517) 17.6 (44.7) 8.8 (22.4) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) CampusLink LT™ I/O Plenum Dielectric (Single Jacket) DPLDB Series | OFNP/FT6 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.37 (9.3) 55 (82) 7.4 (18.8) 3.7 (9.4) 62 to 72 6 12 0.40 (10.2) 67 (99) 8.0 (20.4) 4.0 (10.2) 74 to 84 7 12 0.44 (11.1) 80 (119) 8.8 (22.4) 4.4 (11.2) 86 to 96 8 12 0.48 (12.2) 97 (145) 9.6 (24.4) 4.8 (12.2) 98 to 144 12 / 6 12 0.61 (15.6) 138 (206) 12.2 (31.0) 6.1 (15.5) Temperature Range Shipping and Storage: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Riser & Plenum Mechanical Specifications (-50o C to +70o C) (-40o C to +70o C) Installation: (Riser) +14o F to +140o F (-10o C to +60o C) (Plenum) +32o F to +140o F (0o C to +60o C) Operation: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Maximum installation load: 600 lbf (2670 N) Maximum operation load: 180 lbf (801 N) (-50o C to +70o C) (-40o C to +70o C) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommends storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.Page 52 of 63
Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below. Example: CampusLink LT™ loose tube | indoor-outdoor riser | dry buffer tubes | dielectric (single jacket) with aluminum interlock armor 12 -62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet) LENGTH MARKINGS 1 2 F PRODUCT FAMILY 3 CONSTRUCTION DRLDB 4 FIBER GROUPING AJ 5 12 FIBER TYPE 6 G6 FIBER GRADE 048 PART NUMBER CONSTRUCTION FIBER INFORMATION 1 LENGTH MARKINGS 5 FIBER TYPE F = Feet or M = Meters 7 FIBER COUNT M2 SINGLE-MODE HB = Single-Mode (ITU G.652 C & D) Low Water Peak 2 PRODUCT FAMILY Riser / FT4 | Dry Tubes | OFNR / FT4 ES = Enhanced Single-Mode (ITU G.652 C & D) CE = Corning™ SMF28e+ Single-Mode B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D) DRLDB = Indoor-Outdoor Riser All-Dielectric (single jacket) 2 to 288 DRLDC = Indoor-Outdoor Riser, All-Dielectric (double jacket) 2 to 144 B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ Riser / FT4 | Dry Tubes | OFCR / FT4 DRLDD = Indoor-Outdoor Riser, Armored (double jacket) 2 to 144 Plenum / FT6 | Dry Tubes | OFNP /FT6 DPLDB = Indoor-Outdoor Plenum, All-Dielectric (single jacket) 2 to 144 3 CONSTRUCTION (blank) = none AJ = Jacketed aluminum (use with DRLDB and DPLDB) 10 GbE Dist (m) G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ 6 FIBER COUNT 002 to 288 fibers 7 FIBER GRADE SJ = Jacketed steel (use with DRLDB and DPLDB) 4 FIBER GROUPING 12 = 12f per unit or tube SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, B1, B2 or CE MULTIMODE Attenuation (dB/km) Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Other cable constructions and fiber performance grades available on request.Page 53 of 63
IN MA FACTURE D NU ExpressLT™ Dry Dry loose tube cable (2.5 mm) MDPE Outer Jacket Water Blocking Tape MDPE Inner Jacket (Double Jacket Designs Only) Central Strength Member Outer Strength Members (where applicable) Dry Buffer Tube Containing up to 12 Fibers Ripcord ezPREP® Corrugated Steel Armor (Optional) A versatile, multi-purpose fiber cable designed for ease of use and buffer tube mid-span storage applications Overview Features and Benefits Prysmian’s popular ExpressLT™ cable combines buffer tubes with enhanced flexibility, a completely dry water-blocking system, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage. Easy Cable Entry and Preparation Applications Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored) Constructions Dielectric, armored, double armored, dual jacket Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode, multimode, bend-insensitive SM, NZDS Options Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped Jacket, factory-installed pulling eye Similar Alternatives Gel-filled buffer tubes / LT 2.0 / heavy duty / central / indoor-outdoor / indoor / self-support / microduct Performance Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11 RUS LISTED Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom Dry water-blocked core speeds cable access - Dry, water-blocked tubes reduce prep time by an average of 15 minutes per cable end - Available with ezPREP® armor to allow easy access to the core in mid-sheath entries - Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core - Ripcord speeds cable entry & outer jacket removal Available with ezPREP® Armor - The jacket can be easily separated from the armor without a heat gun or torch - Armored cable access, bonding and grounding are faster, easier and safer Flexible Routing and Termination - Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20' - 2.5mm buffer tubes with enhanced flexibility simplify routing and splice preparation Multi-Purpose Design - Suitable for aerial lashed, duct, and direct buried installation (when armored) - Small diameter and light weight, extends reel and installation lengths - Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance 500A DS016 EXPRESSLT DRY 02-16 Product Snapshot -
As listed on the current system