Page 48 of 63
With this latest product enhancement, Prysmian Group is reaffirming its commitment to investing in its optical fiber and cable capacities to respond to the evolving needs of the market and support its customers in developing new, reliable and efficient broadband networks. Join us for the introduction of these new products at the upcoming 2018 ISE Expo. Held from August 14-16 in Denver, CO, the ISE Expo is the ICT industry’s premier educational event for wireline and wireless network evolution. Come visit us at our booth (#827) and for more information about Prysmian Group, visit na.prysmiangroup.com. About Prysmian Group North America Prysmian Group serves both the telecom and energy cable markets in North America with over 5,800 employees at 23 plants across the continent and sales of over $1.5 billion in 2016. Headquartered in Highland Heights, Kentucky, Prysmian’s North American Telecom Solutions unit produces a range of high-quality copper and fiber optic cable and solutions for data, video and voice transmission applications. In the energy sector, the company offers end-to-end underground cables solutions for the transmission and distribution of low, medium, high and extra high voltage systems. Prysmian Group has two fiber optic manufacturing facilities in the United States, including the only co-located fiber and cable facility in North America. Prysmian Group is a public company, listed on the Italian Stock Exchange in the FTSE MIB index. Media Contacts Charlie Schicht External Communications Manager T: [phone removed] [email removed] Hannah Nuccio Lou Hammond Group T: [phone removed] [email removed] ### Release No. 1067Page 49 of 63
IN MA FACTURE D NU CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables Flame Retardant Jacket Flame Retardant Tape Central Strength Member Water Blocking Tape Dry Buffer Tube Containing up to 12 Fibers Ripcord Versatile indoor-outdoor flame rated fiber cables - ideal for interbuilding and building transition applications Overview Prysmian’s indoor-outdoor dry loose tube riser or plenum designs provide flame-rated network solutions for a diverse number of network applications. These cables combine flexible dry buffer tubes and swellable water blocking materials with Prysmian’s extensive portfolio of single-mode and multimode optical fibers. Incorporating proven outside plant design elements, this cable may be employed in outdoor aerial lashed, duct, and direct buried environments. Because of its application diversity, this advanced product eliminates the necessity and expense for traditional cable transition points once required in legacy systems. Cost savings and system long term reliability are achieved by enabling cable placement virtually anywhere in the network. Product Snapshot Applications Multi-purpose indoor/outdoor aerial, lashed, duct, and direct buried Constructions Dielectric (single & dual jacket), ezPREP® corrugated armor, interlock armor Features and Benefits - Fiber identification using TIA standardized color coding - Dry buffer tubes simplifies access and reduces prep time - Flame-retardant, black UV-resistant outer jacket - Available with bend-insensitive single-mode and multimode optical fibers - Interlock armor designs available for added durability - Will support all high performance networks including OM4/10 gigabit ethernet systems Flexible kink-resistant buffer tubes for routing and storage Fiber Count 2 to 288 (Riser) / 2-144 (Plenum) Fiber Types Single-mode (ESMF, bend-insensitive) multimode (62.5/125-OM1, 50/125-OM2+, OM3 & OM4) Standards TIA/EIA-568, ANSI/ICEA S-83-596, ANSI/ ICEA S-104-696, UL-1666, NFPA 262, CSA 22.2 No 230, Telcordia GR-409, Telcordia GR-20, CE RoHS Compliant Registered Supplier ISO 9001, ISO 14001, TL 9000, and OHSAS 18001 Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Flame Ratings Riser (OFNR / OFCR / FT4) / Plenum (OFNP/OFCP/FT6)Page 50 of 63
CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser Dielectric (Single Jacket - Dry) DRLDB Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) 2 to 60 5 12 0.40 (10.1) 63 (93) 8.0 (20.2) 4.0 (10.1) 62 to 72 6 12 0.43 (10.8) 69 (102) 8.6 (21.7) 4.3 (10.9) 74 to 84 7 12 0.47 (12.0) 85 (126) 9.5 (24.0) 4.8 (12.0) 86 to 96 8 12 0.50 (12.8) 96 (143) 10.1 (25.6) 5.1 (12.8) 5.5 (13.9) 98 to 108 9 12 0.55 (13.9) 114 (169) 11.0 (27.8) 110 to 120 10 12 0.57 (14.5) 123 (183) 11.4 (29.0) 5.7 (14.5) 122 to 132 11 12 0.60 (15.4) 139 (207) 12.1 (30.8) 6.1 (15.4) 6.5 (16.4) 134 to 144 12 12 0.64 (16.3) 158 (234) 12.9 (32.7) 146 to 216 12 / 6 12 0.67 (17.0) 153 (228) 13.5 (34.1) 6.8 (17.1) 218 to 264 14 / 8 12 0.73 (18.6) 184 (273) 14.7 (37.3) 7.4 (18.7) 266 to 288 15 / 9 12 0.78 (19.7) 205 (305) 15.6 (39.5) 7.8 (19.8) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) Note: the compression rating for counts of 60 and below is 100N/cm. CampusLink LT™ I/O Riser Dielectric (Double Jacket - Dry) DRLDC Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.52 (13.2) 114 (169) 10.4 (26.4) 5.2 (13.2) 62 to 72 6 12 0.55 (13.9) 123 (183) 11.0 (27.9) 5.5 (14.0) 74 to 84 7 12 0.59 (15.1) 144 (214) 11.9 (30.2) 6.0 (15.1) 86 to 96 8 12 0.63 (15.9) 159 (237) 12.6 (31.8) 6.3 (15.9) 98 to 108 9 12 0.67 (17.0) 181 (270) 13.4 (34.0) 6.7 (17.0) 110 to 120 10 12 0.69 (17.6) 194 (288) 13.9 (35.2) 7.0 (17.6) 122 to 132 11 12 0.73 (18.5) 214 (318) 14.6 (37.0) 7.3 (18.5) 134 to 144 12 12 0.76 (19.4) 237 (352) 15.3 (38.9) 7.7 (19.5) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.Page 51 of 63
CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser with Corrugated Armor (1A 2J - Dry) DRLDD Series | OFCR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 62 to 72 6 12 Cable Weight lb/kft (kg/km) Bend Radius Load inches (cm) 0.63 (16.0) 190 (283) 12.6 (32.0) 6.3 (16.0) 0.66 (16.8) 204 (304) 13.2 (33.6) 6.6 (16.8) Diameter inches (mm) Bend Radius No Load inches (cm) 74 to 84 7 12 0.71 (18.0) 231 (344) 14.2 (36.1) 7.1 (18.1) 86 to 96 8 12 0.74 (18.8) 250 (372) 14.8 (37.6) 7.4 (18.8) 98 to 108 9 12 0.78 (19.8) 278 (413) 15.6 (40.0) 7.8 (19.9) 110 to 120 10 12 0.80 (20.3) 294 (438) 16.0 (40.7) 8.0 (20.4) 122 to 132 11 12 0.84 (21.3) 320 (476) 16.8 (42.7) 8.4 (21.4) 134 to 144 12 12 0.88 (22.4) 347 (517) 17.6 (44.7) 8.8 (22.4) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) CampusLink LT™ I/O Plenum Dielectric (Single Jacket) DPLDB Series | OFNP/FT6 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.37 (9.3) 55 (82) 7.4 (18.8) 3.7 (9.4) 62 to 72 6 12 0.40 (10.2) 67 (99) 8.0 (20.4) 4.0 (10.2) 74 to 84 7 12 0.44 (11.1) 80 (119) 8.8 (22.4) 4.4 (11.2) 86 to 96 8 12 0.48 (12.2) 97 (145) 9.6 (24.4) 4.8 (12.2) 98 to 144 12 / 6 12 0.61 (15.6) 138 (206) 12.2 (31.0) 6.1 (15.5) Temperature Range Shipping and Storage: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Riser & Plenum Mechanical Specifications (-50o C to +70o C) (-40o C to +70o C) Installation: (Riser) +14o F to +140o F (-10o C to +60o C) (Plenum) +32o F to +140o F (0o C to +60o C) Operation: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Maximum installation load: 600 lbf (2670 N) Maximum operation load: 180 lbf (801 N) (-50o C to +70o C) (-40o C to +70o C) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommends storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.Page 52 of 63
Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below. Example: CampusLink LT™ loose tube | indoor-outdoor riser | dry buffer tubes | dielectric (single jacket) with aluminum interlock armor 12 -62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet) LENGTH MARKINGS 1 2 F PRODUCT FAMILY 3 CONSTRUCTION DRLDB 4 FIBER GROUPING AJ 5 12 FIBER TYPE 6 G6 FIBER GRADE 048 PART NUMBER CONSTRUCTION FIBER INFORMATION 1 LENGTH MARKINGS 5 FIBER TYPE F = Feet or M = Meters 7 FIBER COUNT M2 SINGLE-MODE HB = Single-Mode (ITU G.652 C & D) Low Water Peak 2 PRODUCT FAMILY Riser / FT4 | Dry Tubes | OFNR / FT4 ES = Enhanced Single-Mode (ITU G.652 C & D) CE = Corning™ SMF28e+ Single-Mode B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D) DRLDB = Indoor-Outdoor Riser All-Dielectric (single jacket) 2 to 288 DRLDC = Indoor-Outdoor Riser, All-Dielectric (double jacket) 2 to 144 B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ Riser / FT4 | Dry Tubes | OFCR / FT4 DRLDD = Indoor-Outdoor Riser, Armored (double jacket) 2 to 144 Plenum / FT6 | Dry Tubes | OFNP /FT6 DPLDB = Indoor-Outdoor Plenum, All-Dielectric (single jacket) 2 to 144 3 CONSTRUCTION (blank) = none AJ = Jacketed aluminum (use with DRLDB and DPLDB) 10 GbE Dist (m) G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ 6 FIBER COUNT 002 to 288 fibers 7 FIBER GRADE SJ = Jacketed steel (use with DRLDB and DPLDB) 4 FIBER GROUPING 12 = 12f per unit or tube SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, B1, B2 or CE MULTIMODE Attenuation (dB/km) Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Other cable constructions and fiber performance grades available on request.Page 53 of 63
IN MA FACTURE D NU ExpressLT™ Dry Dry loose tube cable (2.5 mm) MDPE Outer Jacket Water Blocking Tape MDPE Inner Jacket (Double Jacket Designs Only) Central Strength Member Outer Strength Members (where applicable) Dry Buffer Tube Containing up to 12 Fibers Ripcord ezPREP® Corrugated Steel Armor (Optional) A versatile, multi-purpose fiber cable designed for ease of use and buffer tube mid-span storage applications Overview Features and Benefits Prysmian’s popular ExpressLT™ cable combines buffer tubes with enhanced flexibility, a completely dry water-blocking system, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage. Easy Cable Entry and Preparation Applications Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored) Constructions Dielectric, armored, double armored, dual jacket Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode, multimode, bend-insensitive SM, NZDS Options Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped Jacket, factory-installed pulling eye Similar Alternatives Gel-filled buffer tubes / LT 2.0 / heavy duty / central / indoor-outdoor / indoor / self-support / microduct Performance Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11 RUS LISTED Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom Dry water-blocked core speeds cable access - Dry, water-blocked tubes reduce prep time by an average of 15 minutes per cable end - Available with ezPREP® armor to allow easy access to the core in mid-sheath entries - Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core - Ripcord speeds cable entry & outer jacket removal Available with ezPREP® Armor - The jacket can be easily separated from the armor without a heat gun or torch - Armored cable access, bonding and grounding are faster, easier and safer Flexible Routing and Termination - Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20' - 2.5mm buffer tubes with enhanced flexibility simplify routing and splice preparation Multi-Purpose Design - Suitable for aerial lashed, duct, and direct buried installation (when armored) - Small diameter and light weight, extends reel and installation lengths - Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance 500A DS016 EXPRESSLT DRY 02-16 Product Snapshot -Page 54 of 63
ExpressLT™ Dry Dry loose tube cable (2.5 mm) Dielectric (Non-Armored) (EDH1JKT) Fiber Count # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 4 (10) 4 to 60 5 0.40 (10.1) 43 (64) 8 (20) 62 to 72 6 0.43 (10.9) 50 (75) 8 (22) 4 (11) 74 to 96 8 0.50 (12.6) 65 (97) 10 (25) 5 (13) 98 to 120 10 0.55 (14.1) 81 (121) 11 (28) 6 (14) 122 to 144 12 0.63 (15.9) 105 (156) 13 (32) 6 (16) 146 to 216 18 0.63 (15.9) 105 (156) 13 (32) 6 (16) 228 to 264 22 0.68 (17.3) 128 (190) 14 (35) 7 (17) 276 to 288 24 0.72 (18.3) 145 (216) 14 (37) 7 (18) 290 to 432 36 0.80 (20.4) 154 (229) 16 (41) 8 (21) Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 5 (12) Single Jacket Armored (SP) (EDH1A1J) Fiber Count # of Buffer Tubes 4 to 60 5 0.46 (11.8) 89 (132) 9 (24) 62 to 72 6 0.50 (12.6) 97 (145) 10 (25) 5 (13) 74 to 96 8 0.56 (14.3) 125 (186) 11 (29) 6 (14) 98 to 120 10 0.62 (15.8) 148 (220) 12 (32) 6 (16) 122 to 144 12 0.69 (17.6) 176 (262) 14 (35) 7 (18) 146 to 216 18 0.70 (17.9) 176 (262) 14 (36) 7 (18) 228 to 264 22 0.76 (19.4) 196 (291) 15 (39) 8 (19) 276 to 288 24 0.81 (20.7) 214 (319) 16 (42) 8 (21) 290 to 432 36 0.90 (23.0) 230 (342) 18 (46) 9 (23) Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) Fiber Count # of Buffer Tubes 4 to 60 5 0.53 (13.5) 107 (160) 11 (27) 5 (14) 62 to 72 6 0.55 (14.0) 122 (181) 11 (28) 5 (14) 6 (16) 74 to 96 8 0.61 (15.5) 137 (204) 12 (31) 98 to 120 10 0.67 (17.1) 167 (249) 13 (34) 7 (17) 122 to 144 12 0.74 (18.9) 198 (294) 15 (38) 7 (19) 146 to 216 18 0.76 (19.2) 198 (294) 15 (38) 8 (19) 228 to 264 22 0.80 (20.4) 220 (327) 16 (41) 8 (20) 276 to 288 24 0.86 (21.8) 239 (356) 17 (44) 9 (22) 290 to 432 36 0.94 (24.0) 257 (382) 19 (48) 9 (24) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS016 EXPRESSLT DRY 02-16 Double Jacket Single Armored (PSP) (EDH1A2J)Page 55 of 63
ExpressLT™ Dry Dry loose tube cable (2.5 mm) Dielectric Double Jacket (PDP) (EDHNA2J) Fiber Count # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 4 to 60 5 0.46 (11.7) 63 (96) 9 (23) 5 (12) 62 to 72 6 0.48 (12.2) 73 (108) 10 (25) 5 (12) 74 to 96 8 0.54 (13.8) 89 (133) 11 (28) 5 (14) 98 to 120 10 0.61 (15.4) 111 (165) 12 (31) 6 (15) 122 to 144 12 0.67 (17.1) 133 (198) 13 (34) 7 (17) 146 to 216 18 0.67 (17.1) 137 (204) 13 (34) 7 (17) 218 to 264 22 0.74 (18.7) 159 (237) 15 (37) 7 (19) 266 to 288 24 0.78 (19.8) 179 (266) 16 (40) 8 (20) # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 6 (16) Double Jacket Double Armored (SPSP) (EDH2A2J) Fiber Count 4 to 60 5 0.64 (16.3) 182 (272) 13 (33) 62 to 72 6 0.67 (17.1) 194 (289) 13 (34) 7 (17) 74 to 96 8 0.75 (19.1) 226 (336) 15 (38) 8 (19) 8 (20) 98 to 120 10 0.80 (20.4) 258 (384) 16 (41) 122 to 144 12 0.88 (22.4) 312 (465) 18 (45) 9 (22) 146 to 216 18 0.88 (22.4) 305 (454) 18 (45) 9 (22) 218 to 264 22 0.94 (23.9) 338 (503) 19 (48) 9 (24) 266 to 288 24 0.98 (24.9) 368 (547) 20 (50) 10 (25) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 7 (18) Triple Jacket Double Armored (PSPSP) (EDH2A3J) # of Buffer Tubes Diameter inches (mm) 4 to 60 5 0.70 (17.8) 215 (320) 14 (36) 62 to 72 6 0.73 (18.6) 228 (339) 15 (37) 7 (19) 74 to 96 8 0.78 (19.9) 265 (394) 16 (40) 8 (20) 98 to 120 10 0.86 (21.9) 313 (466) 17 (43) 9 (22) 122 to 144 12 0.93 (23.7) 367 (546) 19 (47) 9 (24) 146 to 216 18 0.93 (23.7) 367 (546) 19 (47) 9 (24) 218 to 264 22 0.98 (25.0) 402 (598) 20 (50) 10 (25) 266 to 288 24 1.02 (26.0) 429 (639) 20 (52) 10 (26) Installation Temperature Range Maximum installation load: 600 lbf (2700 N) Maximum operation load: 180 lbf (800 N) Shipping and Storage: -40o F to +167o F Installation: -22o F to +140o F Operation: -40o F to +158o F Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom (-40o C to +75o C) (-30o C to +60o C) (-40o C to +70o C) 500A DS016 EXPRESSLT DRY 02-16 Fiber CountPage 56 of 63
Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below Example: ExpressLT™ dry (gel-free) | single armor single jacket (12 fibers/tube) with 72 single-mode fibers (printed in feet) LENGTH MARKINGS 1 2 F PRODUCT FAMILY EDH 3 CONSTRUCTION 1A1J PART NUMBER CONSTRUCTION 1 LENGTH MARKINGS 4 FIBER GROUPING 5 12 5 FIBER GRADE 072 E3 FIBER TYPE SINGLE-MODE HB = Single-Mode (ITU G.652 C & D) Low Water Peak PRODUCT FAMILY ES = Enhanced Single-Mode (ITU G.652 C & D) CE = Corning™ SMF28e+ Single-Mode B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D) CONSTRUCTION B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) 1JKT = Single Jacket TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656) 1A1J = Single Armor, Single Jacket LA = NZDSF-LA Single-Mode (ITU G.655) 1A2J = Single Armor, Dual Jacket LE = LEAF NZDSF (ITU G.655) 2A2J = Double Armor, Dual Jacket MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ 2A3J = Double Armor, Triple Jacket NA2J = Non Armored, Dual Jacket 4 7 FIBER COUNT FIBER INFORMATION EDH = ExpressLT Dry 3 6 HB F = Feet or M = Meters 2 FIBER TYPE FIBER GROUPING 12 = 12f per tube 6 10 GbE Dist (m) G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ FIBER COUNT 004 to 432 fibers 7 FIBER GRADE SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 NA = 0.40/0.25 N1 = 0.25 MULTIMODE Attenuation (dB/km) 1310/1550 1550 HB, ES, CE, B1, or B2 TeraLight Ultra Single-Mode NZDSF-LA Single-Mode Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued February 2016. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS016 EXPRESSLT DRY 02-16 Other cable constructions and fiber performance grades available on request.Page 57 of 63
),%(5237,&&$%/( 3URGXFW6SHFLILFDWLRQV 3DUW1R0;;;;;;5;1223 ,VVXH'DWH 5HYLVLRQ 06HULHV0LFUR'LVWULEXWLRQ,2 3OHQXP5DWHG)LEHU2SWLF&DEOH &DEOH&URVV6HFWLRQ $SSOLFDWLRQV 2XWGRRUVLQ'XFW,QGRRUVLQWKH3OHQXP6SDFH7UD\,QVWDOODWLRQV $SSOLFDEOH'RFXPHQWV Ͳ7,$(,$)2736WDQGDUGV Ͳ&RORU&RGLQJRI)LEHU2SWLF&DEOHV7,$(,$ Ͳ8/ Ͳ*5&25( Ͳ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ƐƐƵĞĚLJ͗ŶŐŝŶĞĞƌŝŶŐ ĂƚĞ͗ƵŐϬϲ͕ϮϬϭϴ /ƐƐƵĞEŽ͗͘Ϭϱ
As listed on the current system
Motion No. 002 11/20/2026 (Fiber AssetCo, LLC dba Zayo) - Motion for Authorization to Install Additional Facilities Under and Over Certain PROW [26-09-20]