  1. Page 50 of 63

    CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser Dielectric (Single Jacket - Dry) DRLDB Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) 2 to 60 5 12 0.40 (10.1) 63 (93) 8.0 (20.2) 4.0 (10.1) 62 to 72 6 12 0.43 (10.8) 69 (102) 8.6 (21.7) 4.3 (10.9) 74 to 84 7 12 0.47 (12.0) 85 (126) 9.5 (24.0) 4.8 (12.0) 86 to 96 8 12 0.50 (12.8) 96 (143) 10.1 (25.6) 5.1 (12.8) 5.5 (13.9) 98 to 108 9 12 0.55 (13.9) 114 (169) 11.0 (27.8) 110 to 120 10 12 0.57 (14.5) 123 (183) 11.4 (29.0) 5.7 (14.5) 122 to 132 11 12 0.60 (15.4) 139 (207) 12.1 (30.8) 6.1 (15.4) 6.5 (16.4) 134 to 144 12 12 0.64 (16.3) 158 (234) 12.9 (32.7) 146 to 216 12 / 6 12 0.67 (17.0) 153 (228) 13.5 (34.1) 6.8 (17.1) 218 to 264 14 / 8 12 0.73 (18.6) 184 (273) 14.7 (37.3) 7.4 (18.7) 266 to 288 15 / 9 12 0.78 (19.7) 205 (305) 15.6 (39.5) 7.8 (19.8) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) Note: the compression rating for counts of 60 and below is 100N/cm. CampusLink LT™ I/O Riser Dielectric (Double Jacket - Dry) DRLDC Series | OFNR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.52 (13.2) 114 (169) 10.4 (26.4) 5.2 (13.2) 62 to 72 6 12 0.55 (13.9) 123 (183) 11.0 (27.9) 5.5 (14.0) 74 to 84 7 12 0.59 (15.1) 144 (214) 11.9 (30.2) 6.0 (15.1) 86 to 96 8 12 0.63 (15.9) 159 (237) 12.6 (31.8) 6.3 (15.9) 98 to 108 9 12 0.67 (17.0) 181 (270) 13.4 (34.0) 6.7 (17.0) 110 to 120 10 12 0.69 (17.6) 194 (288) 13.9 (35.2) 7.0 (17.6) 122 to 132 11 12 0.73 (18.5) 214 (318) 14.6 (37.0) 7.3 (18.5) 134 to 144 12 12 0.76 (19.4) 237 (352) 15.3 (38.9) 7.7 (19.5) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommend storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.
  2. Page 51 of 63

    CampusLink LT™ Dry Loose Tube | Indoor/Outdoor Indoor-outdoor riser and plenum cables CampusLink LT™ I/O Riser with Corrugated Armor (1A 2J - Dry) DRLDD Series | OFCR / FT4 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 62 to 72 6 12 Cable Weight lb/kft (kg/km) Bend Radius Load inches (cm) 0.63 (16.0) 190 (283) 12.6 (32.0) 6.3 (16.0) 0.66 (16.8) 204 (304) 13.2 (33.6) 6.6 (16.8) Diameter inches (mm) Bend Radius No Load inches (cm) 74 to 84 7 12 0.71 (18.0) 231 (344) 14.2 (36.1) 7.1 (18.1) 86 to 96 8 12 0.74 (18.8) 250 (372) 14.8 (37.6) 7.4 (18.8) 98 to 108 9 12 0.78 (19.8) 278 (413) 15.6 (40.0) 7.8 (19.9) 110 to 120 10 12 0.80 (20.3) 294 (438) 16.0 (40.7) 8.0 (20.4) 122 to 132 11 12 0.84 (21.3) 320 (476) 16.8 (42.7) 8.4 (21.4) 134 to 144 12 12 0.88 (22.4) 347 (517) 17.6 (44.7) 8.8 (22.4) Diameter Inches (mm) Cable Weight lb/kft (kg/km) Bend Radius Load Inches (cm) Bend Radius No Load Inches (cm) CampusLink LT™ I/O Plenum Dielectric (Single Jacket) DPLDB Series | OFNP/FT6 Fiber Count # Buffer Tubes Outer/Inner Layer Fibers per Unit or # of Units 2 to 60 5 12 0.37 (9.3) 55 (82) 7.4 (18.8) 3.7 (9.4) 62 to 72 6 12 0.40 (10.2) 67 (99) 8.0 (20.4) 4.0 (10.2) 74 to 84 7 12 0.44 (11.1) 80 (119) 8.8 (22.4) 4.4 (11.2) 86 to 96 8 12 0.48 (12.2) 97 (145) 9.6 (24.4) 4.8 (12.2) 98 to 144 12 / 6 12 0.61 (15.6) 138 (206) 12.2 (31.0) 6.1 (15.5) Temperature Range Shipping and Storage: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Riser & Plenum Mechanical Specifications (-50o C to +70o C) (-40o C to +70o C) Installation: (Riser) +14o F to +140o F (-10o C to +60o C) (Plenum) +32o F to +140o F (0o C to +60o C) Operation: (Riser) -58o F to +158o F (Plenum) -40o F to +158o F Maximum installation load: 600 lbf (2670 N) Maximum operation load: 180 lbf (801 N) (-50o C to +70o C) (-40o C to +70o C) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian Group recommends storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement.
  3. Page 52 of 63

    Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below. Example: CampusLink LT™ loose tube | indoor-outdoor riser | dry buffer tubes | dielectric (single jacket) with aluminum interlock armor 12 -62.5/125 multimode fibers per buffer tube | 48 fibers total (printed in feet) LENGTH MARKINGS 1 2 F PRODUCT FAMILY 3 CONSTRUCTION DRLDB 4 FIBER GROUPING AJ 5 12 FIBER TYPE 6 G6 FIBER GRADE 048 PART NUMBER CONSTRUCTION FIBER INFORMATION 1 LENGTH MARKINGS 5 FIBER TYPE F = Feet or M = Meters 7 FIBER COUNT M2 SINGLE-MODE HB = Single-Mode (ITU G.652 C & D) Low Water Peak 2 PRODUCT FAMILY Riser / FT4 | Dry Tubes | OFNR / FT4 ES = Enhanced Single-Mode (ITU G.652 C & D) CE = Corning™ SMF28e+ Single-Mode B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D) DRLDB = Indoor-Outdoor Riser All-Dielectric (single jacket) 2 to 288 DRLDC = Indoor-Outdoor Riser, All-Dielectric (double jacket) 2 to 144 B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ Riser / FT4 | Dry Tubes | OFCR / FT4 DRLDD = Indoor-Outdoor Riser, Armored (double jacket) 2 to 144 Plenum / FT6 | Dry Tubes | OFNP /FT6 DPLDB = Indoor-Outdoor Plenum, All-Dielectric (single jacket) 2 to 144 3 CONSTRUCTION (blank) = none AJ = Jacketed aluminum (use with DRLDB and DPLDB) 10 GbE Dist (m) G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ 6 FIBER COUNT 002 to 288 fibers 7 FIBER GRADE SJ = Jacketed steel (use with DRLDB and DPLDB) 4 FIBER GROUPING 12 = 12f per unit or tube SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, B1, B2 or CE MULTIMODE Attenuation (dB/km) Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued October 2016. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500B DS022 CAMPUSLINK LT DRY INDOOR OUTDOOR 10-16 Other cable constructions and fiber performance grades available on request.
  4. Page 53 of 63

    IN MA FACTURE D NU ExpressLT™ Dry Dry loose tube cable (2.5 mm) MDPE Outer Jacket Water Blocking Tape MDPE Inner Jacket (Double Jacket Designs Only) Central Strength Member Outer Strength Members (where applicable) Dry Buffer Tube Containing up to 12 Fibers Ripcord ezPREP® Corrugated Steel Armor (Optional) A versatile, multi-purpose fiber cable designed for ease of use and buffer tube mid-span storage applications Overview Features and Benefits Prysmian’s popular ExpressLT™ cable combines buffer tubes with enhanced flexibility, a completely dry water-blocking system, and optional ezPREP® armor. The buffer tubes are also rated for mid-span storage applications. This combination of features makes ExpressLT™ an ideal solution for applications requiring frequent sheath access and express tube storage. Easy Cable Entry and Preparation Applications Multi-purpose outdoor, aerial lashed, duct, direct buried (when armored) Constructions Dielectric, armored, double armored, dual jacket Count 4 to 432 fibers in color-coded buffer tubes Fiber Types Single-mode, multimode, bend-insensitive SM, NZDS Options Steel central member, 22 or 24 AWG copper pair(s), 16 AWG tonewire, striped Jacket, factory-installed pulling eye Similar Alternatives Gel-filled buffer tubes / LT 2.0 / heavy duty / central / indoor-outdoor / indoor / self-support / microduct Performance Tested in accordance with TIA 455 series FOTPs for fiber optic cables. Complies with ICEA 640, RUS 7 CFR 1755 (PE90 listed), Telcordia GR-20, and IEC 60794-3-11 RUS LISTED Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom Dry water-blocked core speeds cable access - Dry, water-blocked tubes reduce prep time by an average of 15 minutes per cable end - Available with ezPREP® armor to allow easy access to the core in mid-sheath entries - Reverse oscillating stranded core facilitates mid-span access of fibers. Tubes can easily be removed from the core - Ripcord speeds cable entry & outer jacket removal Available with ezPREP® Armor - The jacket can be easily separated from the armor without a heat gun or torch - Armored cable access, bonding and grounding are faster, easier and safer Flexible Routing and Termination - Buffer tubes can be stored in FTTx pedestals, closures and cabinets in lengths up to 20' - 2.5mm buffer tubes with enhanced flexibility simplify routing and splice preparation Multi-Purpose Design - Suitable for aerial lashed, duct, and direct buried installation (when armored) - Small diameter and light weight, extends reel and installation lengths - Optional ezPREP® corrugated steel tape armor provides mechanical protection and rodent resistance 500A DS016 EXPRESSLT DRY 02-16 Product Snapshot -
  5. Page 54 of 63

    ExpressLT™ Dry Dry loose tube cable (2.5 mm) Dielectric (Non-Armored) (EDH1JKT) Fiber Count # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 4 (10) 4 to 60 5 0.40 (10.1) 43 (64) 8 (20) 62 to 72 6 0.43 (10.9) 50 (75) 8 (22) 4 (11) 74 to 96 8 0.50 (12.6) 65 (97) 10 (25) 5 (13) 98 to 120 10 0.55 (14.1) 81 (121) 11 (28) 6 (14) 122 to 144 12 0.63 (15.9) 105 (156) 13 (32) 6 (16) 146 to 216 18 0.63 (15.9) 105 (156) 13 (32) 6 (16) 228 to 264 22 0.68 (17.3) 128 (190) 14 (35) 7 (17) 276 to 288 24 0.72 (18.3) 145 (216) 14 (37) 7 (18) 290 to 432 36 0.80 (20.4) 154 (229) 16 (41) 8 (21) Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 5 (12) Single Jacket Armored (SP) (EDH1A1J) Fiber Count # of Buffer Tubes 4 to 60 5 0.46 (11.8) 89 (132) 9 (24) 62 to 72 6 0.50 (12.6) 97 (145) 10 (25) 5 (13) 74 to 96 8 0.56 (14.3) 125 (186) 11 (29) 6 (14) 98 to 120 10 0.62 (15.8) 148 (220) 12 (32) 6 (16) 122 to 144 12 0.69 (17.6) 176 (262) 14 (35) 7 (18) 146 to 216 18 0.70 (17.9) 176 (262) 14 (36) 7 (18) 228 to 264 22 0.76 (19.4) 196 (291) 15 (39) 8 (19) 276 to 288 24 0.81 (20.7) 214 (319) 16 (42) 8 (21) 290 to 432 36 0.90 (23.0) 230 (342) 18 (46) 9 (23) Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) Fiber Count # of Buffer Tubes 4 to 60 5 0.53 (13.5) 107 (160) 11 (27) 5 (14) 62 to 72 6 0.55 (14.0) 122 (181) 11 (28) 5 (14) 6 (16) 74 to 96 8 0.61 (15.5) 137 (204) 12 (31) 98 to 120 10 0.67 (17.1) 167 (249) 13 (34) 7 (17) 122 to 144 12 0.74 (18.9) 198 (294) 15 (38) 7 (19) 146 to 216 18 0.76 (19.2) 198 (294) 15 (38) 8 (19) 228 to 264 22 0.80 (20.4) 220 (327) 16 (41) 8 (20) 276 to 288 24 0.86 (21.8) 239 (356) 17 (44) 9 (22) 290 to 432 36 0.94 (24.0) 257 (382) 19 (48) 9 (24) Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS016 EXPRESSLT DRY 02-16 Double Jacket Single Armored (PSP) (EDH1A2J)
  6. Page 55 of 63

    ExpressLT™ Dry Dry loose tube cable (2.5 mm) Dielectric Double Jacket (PDP) (EDHNA2J) Fiber Count # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 4 to 60 5 0.46 (11.7) 63 (96) 9 (23) 5 (12) 62 to 72 6 0.48 (12.2) 73 (108) 10 (25) 5 (12) 74 to 96 8 0.54 (13.8) 89 (133) 11 (28) 5 (14) 98 to 120 10 0.61 (15.4) 111 (165) 12 (31) 6 (15) 122 to 144 12 0.67 (17.1) 133 (198) 13 (34) 7 (17) 146 to 216 18 0.67 (17.1) 137 (204) 13 (34) 7 (17) 218 to 264 22 0.74 (18.7) 159 (237) 15 (37) 7 (19) 266 to 288 24 0.78 (19.8) 179 (266) 16 (40) 8 (20) # of Buffer Tubes Diameter inches (mm) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 6 (16) Double Jacket Double Armored (SPSP) (EDH2A2J) Fiber Count 4 to 60 5 0.64 (16.3) 182 (272) 13 (33) 62 to 72 6 0.67 (17.1) 194 (289) 13 (34) 7 (17) 74 to 96 8 0.75 (19.1) 226 (336) 15 (38) 8 (19) 8 (20) 98 to 120 10 0.80 (20.4) 258 (384) 16 (41) 122 to 144 12 0.88 (22.4) 312 (465) 18 (45) 9 (22) 146 to 216 18 0.88 (22.4) 305 (454) 18 (45) 9 (22) 218 to 264 22 0.94 (23.9) 338 (503) 19 (48) 9 (24) 266 to 288 24 0.98 (24.9) 368 (547) 20 (50) 10 (25) Approximate Cable Weight lb/kft (kg/km) Bend Radius | Load inches (cm) Bend Radius | No Load inches (cm) 7 (18) Triple Jacket Double Armored (PSPSP) (EDH2A3J) # of Buffer Tubes Diameter inches (mm) 4 to 60 5 0.70 (17.8) 215 (320) 14 (36) 62 to 72 6 0.73 (18.6) 228 (339) 15 (37) 7 (19) 74 to 96 8 0.78 (19.9) 265 (394) 16 (40) 8 (20) 98 to 120 10 0.86 (21.9) 313 (466) 17 (43) 9 (22) 122 to 144 12 0.93 (23.7) 367 (546) 19 (47) 9 (24) 146 to 216 18 0.93 (23.7) 367 (546) 19 (47) 9 (24) 218 to 264 22 0.98 (25.0) 402 (598) 20 (50) 10 (25) 266 to 288 24 1.02 (26.0) 429 (639) 20 (52) 10 (26) Installation Temperature Range Maximum installation load: 600 lbf (2700 N) Maximum operation load: 180 lbf (800 N) Shipping and Storage: -40o F to +167o F Installation: -22o F to +140o F Operation: -40o F to +158o F Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom (-40o C to +75o C) (-30o C to +60o C) (-40o C to +70o C) 500A DS016 EXPRESSLT DRY 02-16 Fiber Count
  7. Page 56 of 63

    Ordering Guide The Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below Example: ExpressLT™ dry (gel-free) | single armor single jacket (12 fibers/tube) with 72 single-mode fibers (printed in feet) LENGTH MARKINGS 1 2 F PRODUCT FAMILY EDH 3 CONSTRUCTION 1A1J PART NUMBER CONSTRUCTION 1 LENGTH MARKINGS 4 FIBER GROUPING 5 12 5 FIBER GRADE 072 E3 FIBER TYPE SINGLE-MODE HB = Single-Mode (ITU G.652 C & D) Low Water Peak PRODUCT FAMILY ES = Enhanced Single-Mode (ITU G.652 C & D) CE = Corning™ SMF28e+ Single-Mode B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D) CONSTRUCTION B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D) 1JKT = Single Jacket TU = TeraLight Ultra Single-Mode (ITU G.655 & G.656) 1A1J = Single Armor, Single Jacket LA = NZDSF-LA Single-Mode (ITU G.655) 1A2J = Single Armor, Dual Jacket LE = LEAF NZDSF (ITU G.655) 2A2J = Double Armor, Dual Jacket MULTIMODE Wavelength (nm) Bandwidth (MHz) 1 GbE Dist (m) G6 = OM1 (62.5μm) 850/1300 200/500 300/550 33/___ G5 = OM2+ BIF (50μm) 850/1300 700/500 800 150/___ 2A3J = Double Armor, Triple Jacket NA2J = Non Armored, Dual Jacket 4 7 FIBER COUNT FIBER INFORMATION EDH = ExpressLT Dry 3 6 HB F = Feet or M = Meters 2 FIBER TYPE FIBER GROUPING 12 = 12f per tube 6 10 GbE Dist (m) G3 = OM3 BIF (50μm) 850/1300 1500/500 1000 300/___ G4 = OM4 BIF (50μm) 850/1300 3500/500 1100 550/___ FIBER COUNT 004 to 432 fibers 7 FIBER GRADE SINGLE-MODE Attenuation (dB/km) Wavelength (nm) Fiber Type E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, or CE E3 = 0.35/0.35/0.25 1310/1383/1550 NA = 0.40/0.25 N1 = 0.25 MULTIMODE Attenuation (dB/km) 1310/1550 1550 HB, ES, CE, B1, or B2 TeraLight Ultra Single-Mode NZDSF-LA Single-Mode Wavelength (nm) M2 = 3.5/1.0 850/1300 M3 = 3.0/1.0 850/1300 © DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2016 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued February 2016. Prysmian Group 700 Industrial Drive | Lexington, SC 29072 [phone removed] | [phone removed] | website: na.prysmiangroup.com/telecom 500A DS016 EXPRESSLT DRY 02-16 Other cable constructions and fiber performance grades available on request.
  8. Page 57 of 63

    ),%(5237,&&$%/( 3URGXFW6SHFLILFDWLRQV 3DUW1R0;;;;;;5;1223 ,VVXH'DWH  5HYLVLRQ 06HULHV0LFUR'LVWULEXWLRQ,2 3OHQXP5DWHG)LEHU2SWLF&DEOH &DEOH&URVV6HFWLRQ $SSOLFDWLRQV 2XWGRRUVLQ'XFW,QGRRUVLQWKH3OHQXP6SDFH7UD\,QVWDOODWLRQV $SSOLFDEOH'RFXPHQWV Ͳ7,$(,$)2736WDQGDUGV Ͳ&RORU&RGLQJRI)LEHU2SWLF&DEOHV7,$(,$ Ͳ8/ Ͳ*5&25( Ͳ&RPSOLDQWZLWK$16,7,$&VWDQGDUG 5HSUHVHQWDWLRQRIDVWDQGDUGILEHUFRQVWUXFWLRQ  &DEOH&RQVWUXFWLRQ'HWDLOV ‡)LEHU 'LPHQVLRQ—P1RPLQDO ‡7LJKW%XIIHU&RORU&RGH $VSHU7,$(,$VWDQGDUGRUSHUFXVWRPHUUHTXLUHPHQW 6FRSH 7KLVGRFXPHQWHVWDEOLVKHVWKHVSHFLILFDWLRQUHTXLUHPHQWVIRUDQLQGRRURXWGRRU ‡&DEOH6WUHQJWK :DWHUVZHOODEOHDUDPLG\DUQVDUHSXOOHGLQZLWKWKHILEHUVXQGHU PLFURGLVWULEXWLRQILEHURSWLFFDEOH7KLVFDEOHFRQVWUXFWLRQFRQVLVWVRID WKHRXWHUMDFNHW —PILEHUVZLWKDUDPLG\DUQVDQGDSOHQXPUDWHGMDFNHW ‡2YHUDOO6KHDWK895HVLVWDQW5HPJXDUG3OHQXP5DWHG3RO\PHU  &RQWLQXHG /ƐƐƵĞĚLJ͗ŶŐŝŶĞĞƌŝŶŐ ĂƚĞ͗ƵŐϬϲ͕ϮϬϭϴ /ƐƐƵĞEŽ͗͘Ϭϱ
  9. Page 58 of 63

    -DFNHW&RORU 1RPLQDO&DEOH'LPHQVLRQV :HLJKWV 5HPHH3URGXFWV3DUW 1XPEHU &DEOH2' :HLJKW 1XPEHU RI)LEHUV LQ PP  OEIW NJNP  0;;;5;1223        0;;;5;1223        0;;;5;1223        0;;;5;1223        0;;;5;1223        'HVLJQDWLRQ &RORU % %ODFN < <HOORZ = 2UDQJH $ $TXD 0 9LROHW &DEOHVSULQWHGLQPHWHUVZLOOKDYHD³05´VXIIL[RQWKHSDUWQXPEHU 2YHUILOO/DXQFK0LQ *LJDELW(WKHUQHW0LQL %DQGZLGWK PXP/LQN'LVWDQFH (0%F 0+]NP  0HWHUV  0+]NP  *LJDELW(WKHUQHW 0LQLPXP/LQN 'LVWDQFH 0HWHUV  QP QP QP 0D[LPXP$WWHQXDWLRQG%NP )LEHU7\SH 31  QP QP QP QP QP QP QP ђŵ20*,* -    1$ 1$   1$     —P20*,* '    1$ 1$   1$     —P20*,* 1    1$ 1$        —P20*,* 9    1$ 1$        6026*' .  1$ 1$   1$ 1$ 1$ 1$  1$  6026*' .  1$ 1$   1$ 1$ 1$ 1$  1$  6026*'*$%,) 8  1$ 1$   1$ 1$ 1$ 1$  1$  1$ 1$   1$ 1$ 1$ 1$  1$  6026*'*$%%,) )   *$ 8 0DQGUHO5DGLXVRIPPWXUQDWQPZLWKDQLQGXFHGDWWHQXDWLRQRI”G%  *$% ) 0DQGUHO5DGLXVRIPPWXUQDWQPZLWKDQLQGXFHGDWWHQXDWLRQRI”G% 3OHDVHFDOOWKHIDFWRU\IRUDOORWKHUILEHUW\SHV &RQWLQXHG /ƐƐƵĞĚLJ͗ŶŐŝŶĞĞƌŝŶŐ ĂƚĞ͗ƵŐϬϲ͕ϮϬϭϴ /ƐƐƵĞEŽ͗͘Ϭϱ
  10. Page 59 of 63

    0HFKDQLFDO (QYLURQPHQWDO3HUIRUPDQFH ͻ0D[LPXP7HQVLOH/RDG ,QVWDOODWLRQ1OEI /RQJ7HUP1OEI  ͻ0LQLPXP%HQGLQJ5DGLXV /RDGHG['LDPHWHU 8QORDGHG['LDPHWHU  ͻ,PSDFW5HVLVWDQFH PLQ  ,PSDFWV  ͻ)OH[LQJ“ƒ PLQ  &\FOHV  ͻ7HPSHUDWXUH5DWLQJ 2SHUDWLRQΣ&WRΣ& ,QVWDOODWLRQΣ&WRΣ& 6WRUDJHΣ&WRΣ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ƐƐƵĞĚLJ͗ŶŐŝŶĞĞƌŝŶŐ ĂƚĞ͗ƵŐϬϲ͕ϮϬϭϴ /ƐƐƵĞEŽ͗͘Ϭϱ

As listed on the current system

Motion No. 002 11/20/2026 (Fiber AssetCo, LLC dba Zayo) - Motion for Authorization to Install Additional Facilities Under and Over Certain PROW [26-09-20]

This filing on the current system (opens in a new tab)