  • RRU-159 Attachment 06.pdf

    Interrogatory responsesPDF · 47 MB · 459 pages

    Page 18 of 459 · matches on 2 pages

    switchgear are required to improve reliability by increasing the contingency load carrying capability of the substation and feeders. Eversource’s “SYS PLAN-010 Bulk Distribution Substation Assessment Procedure … keep the substation loading below 75% of the existing transformer’s nameplate rating. DSCADA System Resiliency Ridgefield This work order is to purchase CT Technical Training Timpson Training

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 06.xlsx

    Interrogatory responsesExcel · 7.0 MB

    Part 26 of 77 · the words are on different parts Only the first part of this large file's text is searchable.

    create these displays in PI Vision, an existing visualization tool on the Eversource network. A new PI Asset Framework database will be developed. The structure of the dashboard … HARTFORD TRUCK RADION SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Fees + Payment - FP0 CT13D007 | MANCHESTER 3A LOWBAND REPEATER SYST | REPLACE BASE

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 07.pdf

    Interrogatory responsesPDF · 84 MB · 869 pages

    Page 157 of 869 · matches on 5 pages

    normal rating by 104%. Based on Eversource engineering standard, the 47N3 must remain at or below 100% of its normal rating under contingency. To address this issue, project … emergency rating by 118% and 100% respectively. For loss of the 4A7, the 47N3 also exceeds the normal rating by 104%. Based on Eversource engineering standard, the 47N3

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 07.xlsx

    Interrogatory responsesExcel · 12 MB

    Part 26 of 77 · the words are on different parts Only the first part of this large file's text is searchable.

    create these displays in PI Vision, an existing visualization tool on the Eversource network. A new PI Asset Framework database will be developed. The structure of the dashboard … HARTFORD TRUCK RADION SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Joint Line Billing-JL0 CT13D007 | MANCHESTER 3A LOWBAND REPEATER SYST | REPLACE

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 08.pdf

    Interrogatory responsesPDF · 86 MB · 867 pages

    Page 154 of 867 · matches on 4 pages

    normal rating by 104%. Based on Eversource engineering standard, the 47N3 must remain at or below 100% of its normal rating under contingency. To address this issue, project … emergency rating by 118% and 100% respectively. For loss of the 4A7, the 47N3 also exceeds the normal rating by 104%. Based on Eversource engineering standard, the 47N3

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 09.pdf

    Interrogatory responsesPDF · 46 MB · 449 pages

    Page 17 of 449 · matches on 2 pages

    switchgear are required to improve reliability by increasing the contingency load carrying capability of the substation and feeders. Eversource’s “SYS PLAN-010 Bulk Distribution Substation Assessment Procedure … keep the substation loading below 75% of the existing transformer’s nameplate rating. DSCADA System Resiliency Ridgefield This work order is to purchase CT Technical Training Timpson Training

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 09.xlsx

    Interrogatory responsesExcel · 7.1 MB

    Part 25 of 77 · the words are on different parts Only the first part of this large file's text is searchable.

    HARTFORD TRUCK RADION SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Material-M00 CT13D007 | MANCHESTER 3A LOWBAND REPEATER SYST | REPLACE BASE STATIONS … TRUCK RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | Material-M00 CT13D008 | ROCKY HILL 3R LOWBAND REPEATER SYST | REPLACE BASE STATIONS

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 11.pdf

    Interrogatory responsesPDF · 86 MB · 858 pages

    Page 165 of 858 · matches on 4 pages

    emergency rating by 118% and 100% respectively. For loss of the 4A7, the 47N3 also exceeds the normal rating by 104%. Based on Eversource engineering standard, the 47N3 … emergency rating by 118% and 100% respectively. For loss of the 4A7, the 47N3 also exceeds the normal rating by 104%. Based on Eversource engineering standard, the 47N3

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 11.xlsx

    Interrogatory responsesExcel · 12 MB

    Part 26 of 77 · the words are on different parts Only the first part of this large file's text is searchable.

    HARTFORD TRUCK RADION SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | OS Svc-Contr Env-OS1 CT13D007 | MANCHESTER 3A LOWBAND REPEATER SYST … TRUCK RADIO SYSTEM. THIS WILL REPLACE AGING BASE STATIONS AS WELL AS INCREASE FUNCTIONALITY. PROJECT IT1DWANA | OS Svc-Contr Env-OS1 CT13D008 | ROCKY HILL 3R LOWBAND REPEATER SYST

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules

  • RRU-159 Attachment 12.pdf

    Interrogatory responsesPDF · 82 MB · 802 pages

    Page 30 of 802 · matches on 3 pages

    switchgear are required to improve reliability by increasing the contingency load carrying capability of the substation and feeders. Eversource’s “SYS PLAN-010 Bulk Distribution Substation Assessment Procedure … switchgear are required to improve reliability by increasing the contingency load carrying capability of the substation and feeders. Eversource’s “SYS PLAN-010 Bulk Distribution Substation Assessment Procedure

    Docket 26-05-10Application of The Connecticut Light and Power Company d/b/a Eversource Energy to Amend its Rate Schedules